Abstract

Purpose

The purpose of this study was to analyze fracture patterns and the magnitude of displacement in the distal radioulnar joint (DRUJ), by three-dimensional (3D) computed tomography (CT), for distal radius fractures with intra-articular displacement of the radiocarpal joint.

Methods

We reconstructed 3D images for 72 consecutive patients with displaced intra-articular distal radius fracture on the basis of fine-cut axial CT data. The fracture patterns involving the DRUJ were classified on the basis of the location and direction of fracture lines, and the extent of fracture comminution. We measured the maximum spatial distance of the gap and the step between the fragments in each 3D image, and the magnitudes of displacement between the groups were compared by analysis of variance followed by post-hoc analysis by use of Tukey’s test.

Results

Sixty wrists had a fracture involving the DRUJ. We classified the 60 wrists into 3 types of fracture pattern. Type 1 was a transverse fracture with minimum displacement. Type 2, in which fracture lines extended into the distal margin of the sigmoid notch, was the most common longitudinal fracture. Type 3 was a fracture with multiple fragments. The step and gap in Type 3 was significantly larger than that in the other types.

Conclusions

Eighty-three percent of intra-articular distal radius fractures had DRUJ involvement, and 28 % of the wrists had multiple fragments. For Type 3 fractures with dorsal or proximal comminution displacement was significantly larger than for simple Type 1 and 2 fractures. Surgical intervention for the DRUJ fragment may be beneficial when there is remarkable intra-articular displacement.
Literature
1.
go back to reference Geissler WB, Fernandez DL, Lamey DM. Distal radioulnar joint injuries associated with fractures of the distal radius. Clin Orthop Relat Res. 1996;327:135–46.PubMedCrossRef Geissler WB, Fernandez DL, Lamey DM. Distal radioulnar joint injuries associated with fractures of the distal radius. Clin Orthop Relat Res. 1996;327:135–46.PubMedCrossRef
2.
go back to reference Cheng HS, Hung LK, Ho PC, Wong J. An analysis of causes and treatment outcome of chronic wrist pain after distal radial fractures. Hand Surg. 2008;13:1–10.PubMedCrossRef Cheng HS, Hung LK, Ho PC, Wong J. An analysis of causes and treatment outcome of chronic wrist pain after distal radial fractures. Hand Surg. 2008;13:1–10.PubMedCrossRef
3.
go back to reference Rozental TD, Beredjiklain PK, Bozentka DJ. Longitudinal radioulnar dissociation. J Am Acad Orthop Surg. 2003;11:68–73.PubMed Rozental TD, Beredjiklain PK, Bozentka DJ. Longitudinal radioulnar dissociation. J Am Acad Orthop Surg. 2003;11:68–73.PubMed
4.
go back to reference Kleinman WB. Distal radius instability and stiffness: common complications of distal radius fractures. Hand Clin. 2010;26:245–64.PubMedCrossRef Kleinman WB. Distal radius instability and stiffness: common complications of distal radius fractures. Hand Clin. 2010;26:245–64.PubMedCrossRef
5.
go back to reference Kihara H, Palmer AK, Werner FW, Short WH, Fortino MD. The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. J Hand Surg. 1996;21:40–7.CrossRef Kihara H, Palmer AK, Werner FW, Short WH, Fortino MD. The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. J Hand Surg. 1996;21:40–7.CrossRef
6.
go back to reference Doi K, Hattori Y, Otsuka K, Abe Y, Yamamoto H. Intra-articular fractures of the distal aspect of the radius: arthroscopically assisted reduction compared with open reduction and internal fixation. J Bone Jt Surg. 1999;81:1093–110. Doi K, Hattori Y, Otsuka K, Abe Y, Yamamoto H. Intra-articular fractures of the distal aspect of the radius: arthroscopically assisted reduction compared with open reduction and internal fixation. J Bone Jt Surg. 1999;81:1093–110.
7.
go back to reference Hunt TR, Hastings H 2nd, Graham TJ. A systemic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin. 1998;14:239–49.PubMed Hunt TR, Hastings H 2nd, Graham TJ. A systemic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin. 1998;14:239–49.PubMed
8.
go back to reference Cheng CY, Chang CH. Corrective osteotomy for intra-articular malunion of the sigmoid notch of the distal part of the radius: a case report. Hand Surg. 2008;13:93–7.PubMedCrossRef Cheng CY, Chang CH. Corrective osteotomy for intra-articular malunion of the sigmoid notch of the distal part of the radius: a case report. Hand Surg. 2008;13:93–7.PubMedCrossRef
9.
go back to reference Frykman G. Fracture of the distal radius including sequelae—shoulder–hand–finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function: a clinical and experimental study. Acta Orthop Scand. 1967;3(suppl 108):1–153. Frykman G. Fracture of the distal radius including sequelae—shoulder–hand–finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function: a clinical and experimental study. Acta Orthop Scand. 1967;3(suppl 108):1–153.
10.
go back to reference Pruitt LP, Gilula LA, Manske PR, Vannier MW. Computed tomography scanning with image reconstruction in evaluation of distal radius fractures. J Hand Surg. 1994;19:720–7.CrossRef Pruitt LP, Gilula LA, Manske PR, Vannier MW. Computed tomography scanning with image reconstruction in evaluation of distal radius fractures. J Hand Surg. 1994;19:720–7.CrossRef
11.
go back to reference Rozental TD, Bozentka DJ, Katz MA, Steinberg DR, Beredjiklian PK. Evaluation of the sigmoid notch with computed tomography following intra-articular distal radius fracture. J Hand Surg. 2001;26A:244–51. Rozental TD, Bozentka DJ, Katz MA, Steinberg DR, Beredjiklian PK. Evaluation of the sigmoid notch with computed tomography following intra-articular distal radius fracture. J Hand Surg. 2001;26A:244–51.
12.
go back to reference Harness NG, Ring D, Zurakowski D, Harris GJ, Jupiter JB. The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures. J Bone Jt Surg Am. 2006;88:1315–23.CrossRef Harness NG, Ring D, Zurakowski D, Harris GJ, Jupiter JB. The influence of three-dimensional computed tomography reconstructions on the characterization and treatment of distal radial fractures. J Bone Jt Surg Am. 2006;88:1315–23.CrossRef
13.
go back to reference Heo YM, Roh JY, Kim SB, Yi JW, Kim KK, Oh BH. Evaluation of the sigmoid notch in the intra-articular distal radius fractures: the efficacy of computed tomography compared with plain X-ray. Clin Orthop Surg. 2012;4:83–90.PubMedCrossRef Heo YM, Roh JY, Kim SB, Yi JW, Kim KK, Oh BH. Evaluation of the sigmoid notch in the intra-articular distal radius fractures: the efficacy of computed tomography compared with plain X-ray. Clin Orthop Surg. 2012;4:83–90.PubMedCrossRef
14.
go back to reference Johnston GH, Friedman L, Kriegler JC. Computed tomographic evaluation of acute distal radial fractures. J Hand Surg. 1992;17:738–44.CrossRef Johnston GH, Friedman L, Kriegler JC. Computed tomographic evaluation of acute distal radial fractures. J Hand Surg. 1992;17:738–44.CrossRef
15.
go back to reference Cole RJ, Bindra RR, Evanoff BA, Gilula LA, Yamaguchi K, Gelberman RH. Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliability of plain radiography versus computed tomography. J Hand Surg. 1997;22:792–800.CrossRef Cole RJ, Bindra RR, Evanoff BA, Gilula LA, Yamaguchi K, Gelberman RH. Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliability of plain radiography versus computed tomography. J Hand Surg. 1997;22:792–800.CrossRef
16.
go back to reference Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg. 1994;19:325–40.CrossRef Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg. 1994;19:325–40.CrossRef
17.
go back to reference Katz MA, Beredjiklian PK, Bozentka DJ, Steinberg DR. Computed tomography scanning of intra-articular distal radius fractures: does it influence treatment? J Hand Surg. 2001;26:415–21.CrossRef Katz MA, Beredjiklian PK, Bozentka DJ, Steinberg DR. Computed tomography scanning of intra-articular distal radius fractures: does it influence treatment? J Hand Surg. 2001;26:415–21.CrossRef
18.
go back to reference Mandziak DG, Watts AC, Bain GI. Ligament contribution to patterns of articular fractures of the distal radius. J Hand Surg. 2011;36:1621–5.CrossRef Mandziak DG, Watts AC, Bain GI. Ligament contribution to patterns of articular fractures of the distal radius. J Hand Surg. 2011;36:1621–5.CrossRef
19.
go back to reference Nakamura T, Takayama S, Horiuchi Y, Yabe Y. Origins and insertions of the triangular fibrocartilage complex: a histological study. J Hand Surg. 2001;26:446–54. Nakamura T, Takayama S, Horiuchi Y, Yabe Y. Origins and insertions of the triangular fibrocartilage complex: a histological study. J Hand Surg. 2001;26:446–54.
20.
go back to reference Ishii S, Palmer AK, Werner FW, Short WH, Fortino MD. An anatomic study of the ligamentous structure of the triangular fibrocartilage complex. J Hand Surg. 1998;23:977–85.CrossRef Ishii S, Palmer AK, Werner FW, Short WH, Fortino MD. An anatomic study of the ligamentous structure of the triangular fibrocartilage complex. J Hand Surg. 1998;23:977–85.CrossRef
21.
go back to reference Morisawa Y, Nakamura T, Tazaki K. Dorsoradial avulsion of the triangular fibrocartilage complex with an avulsion fracture of the sigmoid notch of the radius. J Hand Surg Eur. 2007;32:705–8. Morisawa Y, Nakamura T, Tazaki K. Dorsoradial avulsion of the triangular fibrocartilage complex with an avulsion fracture of the sigmoid notch of the radius. J Hand Surg Eur. 2007;32:705–8.
22.
go back to reference Collins ED, Vossoughi F. A three-dimensional analysis of the sigmoid notch. Orthop Rev. 2011;3:75–7.CrossRef Collins ED, Vossoughi F. A three-dimensional analysis of the sigmoid notch. Orthop Rev. 2011;3:75–7.CrossRef
Metadata
Title
Intra-articular distal radius fractures involving the distal radioulnar joint (DRUJ): three dimensional computed tomography-based classification
Authors
Yasuaki Nakanishi
Shohei Omokawa
Takamasa Shimizu
Kenichi Nakano
Tsutomu Kira
Yasuhito Tanaka
Publication date
01-09-2013
Publisher
Springer Japan
Published in
Journal of Orthopaedic Science / Issue 5/2013
Print ISSN: 0949-2658
Electronic ISSN: 1436-2023
DOI
https://doi.org/10.1007/s00776-013-0407-0

Other articles of this Issue 5/2013

Journal of Orthopaedic Science 5/2013 Go to the issue