Abstract

Dynamic stabilisation system for the spine (Dynesys) relies on titanium screw purchase within the pedicle. Decision on osseointegration is important especially when the patient becomes symptomatic following initial good outcome. Loose screws make the construct non-functional especially in symptomatic patients. Removal of Dynesys may become necessary to control patient’s symptoms. In this study, we report interobserver reliability of X-ray for the interpretation of Dynesys pedicle screw osseointegration based on the diagnosis of “halo zone” and “Double halo zones” surrounding loose screw. Lumbar spine X-ray images of 50 patients in two views (AP and lateral) were selected from a random sample of 420 Dynesys patients. The total number of pedicle screws reviewed in this study was 260. The investigators (observers) were asked to state whether or not each pedicle screw is loose using “radiolucent zone sign”. Observers were two expert orthopaedic spine consultant surgeons and one expert consultant radiologist and four specialist registrars (SpR) in orthopaedics and radiology. SpR assessments were repeated after 4 months with instructions to use “double-halo sign” for loose screws. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. Using “radiolucent zone sign”, Kappa Index (KI) among three consultants was 0.2198 at 95% CI (0.0520, 0.4916) while for all of the seven assessors (3 consultants and 4 SpR), KI was 0.1462 at 95% CI (0.0332, 0.2592). The use of “double-halo sign” was associated with KI of 0.666 at 95% CI (SE 0.83) among all of the 4 SpR. Based on plain X-ray “radiolucent zone sign”, the inter-observer reliability of detecting loose Dynesys pedicle screw was poor (Kappa index of 0.2). On the other hand, using plain X-ray “double-halo sign” was associated with improved inter-observer reliability and validity.
Literature
2.
go back to reference Bordes-Monmeneu M, Bordes-Garcia V, Rodrigo-Baeza F, Saez D (2005) A dynamic neutralisation system for the spine. DYNESYS SYSTEM. Experience in 94 cases. Neurosurgery 16:499–506 Bordes-Monmeneu M, Bordes-Garcia V, Rodrigo-Baeza F, Saez D (2005) A dynamic neutralisation system for the spine. DYNESYS SYSTEM. Experience in 94 cases. Neurosurgery 16:499–506
3.
go back to reference Clokie CML, Warshawky H (1995) Morphologic and radioauto-graphic studies of bone formation in relation to titanium implants using rat tibia as a model. Int J Oral Maxillofac Implants 10:155–165PubMed Clokie CML, Warshawky H (1995) Morphologic and radioauto-graphic studies of bone formation in relation to titanium implants using rat tibia as a model. Int J Oral Maxillofac Implants 10:155–165PubMed
5.
go back to reference Dakhil-Jerew F, Shepperd J (2008) Outcome following posterior vs. Wiltse approaches to Dynesys. Abstract, Japanese Orthopaedic Association Congress, Sapporo, Japan. May 2008 Dakhil-Jerew F, Shepperd J (2008) Outcome following posterior vs. Wiltse approaches to Dynesys. Abstract, Japanese Orthopaedic Association Congress, Sapporo, Japan. May 2008
6.
go back to reference Dakhil-Jerew F, Shepperd J (2007) Outcome following Dynesys for the treatment of degenerative disc disease. Abstract. European Association of Neurosurgical Societies (EANS) Conference, Glasgow. 4th September 2007. Acta Neurochiurgica: PLIV Dakhil-Jerew F, Shepperd J (2007) Outcome following Dynesys for the treatment of degenerative disc disease. Abstract. European Association of Neurosurgical Societies (EANS) Conference, Glasgow. 4th September 2007. Acta Neurochiurgica: PLIV
7.
go back to reference Dakhil-Jerew F, Shepperd J (2007) Refinement of the clinical indications for the Dynamic Neutralisation System for the Spine. Abstract, British Orthopaedic Research Society. Manchester, 2008 Dakhil-Jerew F, Shepperd J (2007) Refinement of the clinical indications for the Dynamic Neutralisation System for the Spine. Abstract, British Orthopaedic Research Society. Manchester, 2008
8.
go back to reference Dakhil-Jerew F, Shepperd J. (2007) Functional outcome following removal of Dynnesys. British Orthopaedic Research Society meeting, Dundee 2nd July 2007 Dakhil-Jerew F, Shepperd J. (2007) Functional outcome following removal of Dynnesys. British Orthopaedic Research Society meeting, Dundee 2nd July 2007
10.
go back to reference De Lange G, de Putter C (1993) Structure of the bone interface to dental implants in vivo. J Oral Implantol 19:123–135PubMed De Lange G, de Putter C (1993) Structure of the bone interface to dental implants in vivo. J Oral Implantol 19:123–135PubMed
12.
go back to reference Dubois B, de Germay B, Schaerer NS, Fennema P (1999) Dynamic neutralization: a new concept for restabilization of the spine. Lippincott Williams & Wilkins, Philadephia Dubois B, de Germay B, Schaerer NS, Fennema P (1999) Dynamic neutralization: a new concept for restabilization of the spine. Lippincott Williams & Wilkins, Philadephia
13.
go back to reference Fini M, Giavaresi G, Greggi T, Martini L, Aldini NN, Parisini P, Giardino R (2003) Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep. J Biomed Mater Res A 66(1):176–183PubMedCrossRef Fini M, Giavaresi G, Greggi T, Martini L, Aldini NN, Parisini P, Giardino R (2003) Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep. J Biomed Mater Res A 66(1):176–183PubMedCrossRef
14.
go back to reference Gila FJ, Padrosb A, Maneroa JM et al (2001) Growth of bioactive surfaces on titanium and its alloys for orthopaedic and dental implants. Universidad Politecnica de Cataluna, Barcelona, Spain Gila FJ, Padrosb A, Maneroa JM et al (2001) Growth of bioactive surfaces on titanium and its alloys for orthopaedic and dental implants. Universidad Politecnica de Cataluna, Barcelona, Spain
15.
go back to reference Grob D, Benini A, Junge A, Mannion AF (2005) Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine 30(3):324–331PubMedCrossRef Grob D, Benini A, Junge A, Mannion AF (2005) Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine 30(3):324–331PubMedCrossRef
16.
17.
go back to reference Kawaguchi H, McKee MD, Okamoto H, Nanci A (1993) Immunocytochemical and lectin-gold characterization of the interface between alveolar bone and implanted hydroxyapetite in the rate. Cells Mater 3:337–358 Kawaguchi H, McKee MD, Okamoto H, Nanci A (1993) Immunocytochemical and lectin-gold characterization of the interface between alveolar bone and implanted hydroxyapetite in the rate. Cells Mater 3:337–358
18.
go back to reference Krag MH, Beynnon BD, Pope MH et al (1986) An internal fixator for posterior application to short segments of the thoracic, lumbar or lumbosacral spine: design and testing. Clin Orthop Relat Res 203:75–98PubMed Krag MH, Beynnon BD, Pope MH et al (1986) An internal fixator for posterior application to short segments of the thoracic, lumbar or lumbosacral spine: design and testing. Clin Orthop Relat Res 203:75–98PubMed
21.
go back to reference Lapresle P, Missenard G (1995) Hydroxyapatite-coated Diapason screws: first clinical report. J Spinal Disord 8:31–39 Lapresle P, Missenard G (1995) Hydroxyapatite-coated Diapason screws: first clinical report. J Spinal Disord 8:31–39
22.
go back to reference Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. JBJS 81(11):1519–1528 Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. JBJS 81(11):1519–1528
23.
go back to reference Louis R (1986) Fusion of the lumbar and sacral spine by internal fixation with screw plates. Clin Orthop Relat Res 203:18–33PubMed Louis R (1986) Fusion of the lumbar and sacral spine by internal fixation with screw plates. Clin Orthop Relat Res 203:18–33PubMed
24.
go back to reference Lu WW, Luk KD, Cheung KC, Gui-Xing Q, Shen JX, Yuen L, Ouyang J, Leong JC (2004) Microfracture and changes in energy absorption to fracture of young vertebral cancellous bone following physiological fatigue loading. Spine 29(11):1196–1201. doi:10.1097/00007632-200406010-00007 PubMedCrossRef Lu WW, Luk KD, Cheung KC, Gui-Xing Q, Shen JX, Yuen L, Ouyang J, Leong JC (2004) Microfracture and changes in energy absorption to fracture of young vertebral cancellous bone following physiological fatigue loading. Spine 29(11):1196–1201. doi:10.​1097/​00007632-200406010-00007 PubMedCrossRef
25.
go back to reference Nanci A, McCarthy GF, Zalzal S, Clokie CML, Warshawsky H, McKee MD (1994) Tissue response to titanium implants in the rat tibia: ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface. Cells Mater 4:1–30 Nanci A, McCarthy GF, Zalzal S, Clokie CML, Warshawsky H, McKee MD (1994) Tissue response to titanium implants in the rat tibia: ultrastructural, immunocytochemical and lectin-cytochemical characterization of the bone-titanium interface. Cells Mater 4:1–30
26.
go back to reference Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR (2006) Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J 15:913–922. doi:10.1007/s00586-005-0948-9 PubMedCrossRef Niosi CA, Zhu QA, Wilson DC, Keynan O, Wilson DR, Oxland TR (2006) Biomechanical characterization of the three-dimensional kinematic behaviour of the Dynesys dynamic stabilization system: an in vitro study. Eur Spine J 15:913–922. doi:10.​1007/​s00586-005-0948-9 PubMedCrossRef
29.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7PubMed Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7PubMed
30.
go back to reference Steffee AD, Biscup RS, Sitkowski DJ (1986) Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Relat Res 203:45PubMed Steffee AD, Biscup RS, Sitkowski DJ (1986) Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Relat Res 203:45PubMed
31.
go back to reference Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB (2004) Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 29(11):E212–E216PubMedCrossRef Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB (2004) Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 29(11):E212–E216PubMedCrossRef
32.
go back to reference Sandén B, Olerud C, Larsson S (2001) Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep. Eur Spine J 10(4):334–339PubMedCrossRef Sandén B, Olerud C, Larsson S (2001) Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep. Eur Spine J 10(4):334–339PubMedCrossRef
33.
go back to reference Sandén B, Olerud C, Petrén-Mallmin M, Johansson C, Larsson S (2004) The significance of radiolucent zones surrounding pedicle screws. Definition of screw loosening in spinal instrumentation. J Bone Joint Surg Br 86(3):457–461PubMedCrossRef Sandén B, Olerud C, Petrén-Mallmin M, Johansson C, Larsson S (2004) The significance of radiolucent zones surrounding pedicle screws. Definition of screw loosening in spinal instrumentation. J Bone Joint Surg Br 86(3):457–461PubMedCrossRef
34.
go back to reference Sandén B, Olerud C, Petrén-Mallmin M, Larsson S (2002) Hydroxyapatite coating improves fixation of pedicle screws. A clinical study. J Bone Joint Surg Br 84(3):387–391PubMedCrossRef Sandén B, Olerud C, Petrén-Mallmin M, Larsson S (2002) Hydroxyapatite coating improves fixation of pedicle screws. A clinical study. J Bone Joint Surg Br 84(3):387–391PubMedCrossRef
35.
go back to reference Schatzker J, Horne JG, Sumner-Smith G (1975) The effect of movement on the holding power of screws in bone. Clin Orthop Relat Res 111:257–262PubMedCrossRef Schatzker J, Horne JG, Sumner-Smith G (1975) The effect of movement on the holding power of screws in bone. Clin Orthop Relat Res 111:257–262PubMedCrossRef
36.
go back to reference Schmoelz HuberJ, Nydegger T, Claes L, Wilke H (2006) Influence of a dynamic stabilization system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 15(8):1276–1285. doi:10.1007/s00586-005-0032-5 PubMedCrossRef Schmoelz HuberJ, Nydegger T, Claes L, Wilke H (2006) Influence of a dynamic stabilization system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 15(8):1276–1285. doi:10.​1007/​s00586-005-0032-5 PubMedCrossRef
39.
go back to reference Shepard MF, Wang JC, Oshtory R, Yoo J, Kabo JM (2002) Enhancement of pedicle screw fixation through washers. Clin Orthop Relat Res (395):249–254PubMedCrossRef Shepard MF, Wang JC, Oshtory R, Yoo J, Kabo JM (2002) Enhancement of pedicle screw fixation through washers. Clin Orthop Relat Res (395):249–254PubMedCrossRef
40.
go back to reference Sidhu KS, Herkowitz HN (1997) Spinal instrumentation in the management of degenerative disorders of the lumbar spine. Clin Orthop Relat Res 355:39–53 Sidhu KS, Herkowitz HN (1997) Spinal instrumentation in the management of degenerative disorders of the lumbar spine. Clin Orthop Relat Res 355:39–53
41.
go back to reference Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed Stoll TM, Dubois G, Schwarzenbach O (2002) The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Eur Spine J 11(Suppl 2):S170–S178PubMed
42.
go back to reference Taniwaki Y, Takemasa R, Tani T, Mizobuchi H, Yamamoto H (2003) Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study. J Orthop Sci 8(3):408–414. doi:10.1007/s10776-003-0639-6 PubMedCrossRef Taniwaki Y, Takemasa R, Tani T, Mizobuchi H, Yamamoto H (2003) Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study. J Orthop Sci 8(3):408–414. doi:10.​1007/​s10776-003-0639-6 PubMedCrossRef
43.
go back to reference Thomas KA, Kay JF, Cook SD et al (1987) Effect of surface microstructure and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implantmaterials. J Biomed Mater Res 21(12):1395–1414PubMedCrossRef Thomas KA, Kay JF, Cook SD et al (1987) Effect of surface microstructure and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implantmaterials. J Biomed Mater Res 21(12):1395–1414PubMedCrossRef
44.
go back to reference Tokuhashi Y, Matsuzaki H, Oda H, Uei H (2008) Clinical course and significance of the clear zone around the pedicle screws in the lumbar degenerative disease. Spine 33(8):903–908PubMedCrossRef Tokuhashi Y, Matsuzaki H, Oda H, Uei H (2008) Clinical course and significance of the clear zone around the pedicle screws in the lumbar degenerative disease. Spine 33(8):903–908PubMedCrossRef
45.
go back to reference Turner AW, Gillies RM, Svehla MJ, Saito M, Walsh WR (2003) Hydroxyapatite composite resin cement augmentation of pedicle screw fixation. Clin Orthop Relat Res 406:253–261PubMedCrossRef Turner AW, Gillies RM, Svehla MJ, Saito M, Walsh WR (2003) Hydroxyapatite composite resin cement augmentation of pedicle screw fixation. Clin Orthop Relat Res 406:253–261PubMedCrossRef
46.
go back to reference Weinstein JN, Rydevik BL, Rauschning W (1992) Anatomic and technical considerations of pedicle screw fixation. Clin Orthop Relat Res 284:34–46PubMed Weinstein JN, Rydevik BL, Rauschning W (1992) Anatomic and technical considerations of pedicle screw fixation. Clin Orthop Relat Res 284:34–46PubMed
47.
go back to reference Welch WC, Cheng BC, Awad TE, Davis R, Maxwell JH, Delamarter R, Wingate JK, Sherman J, Macenski MM (2007) Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results. Neurosurg Focus 22(1):E8PubMedCrossRef Welch WC, Cheng BC, Awad TE, Davis R, Maxwell JH, Delamarter R, Wingate JK, Sherman J, Macenski MM (2007) Clinical outcomes of the Dynesys dynamic neutralization system: 1-year preliminary results. Neurosurg Focus 22(1):E8PubMedCrossRef
48.
49.
go back to reference Yildirim OS, Aksakal B, Hanyaloglu SC, Erdogan F, Okur A (2006) Hydroxyapatite dip coated and uncoated titanium poly-axial pedicle screws: an in vivo bovine model. Spine 31(8):E215–E220PubMedCrossRef Yildirim OS, Aksakal B, Hanyaloglu SC, Erdogan F, Okur A (2006) Hydroxyapatite dip coated and uncoated titanium poly-axial pedicle screws: an in vivo bovine model. Spine 31(8):E215–E220PubMedCrossRef
50.
go back to reference Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12(2):160–166PubMedCrossRef Zindrick MR, Wiltse LL, Doornik A, Widell EH, Knight GW, Patwardhan AG, Thomas JC, Rothman SL, Fields BT (1987) Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12(2):160–166PubMedCrossRef
Metadata
Title
Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients
Authors
Fras Dakhil-Jerew
H. Jadeja
A. Cohen
J. A. N. Shepperd
Publication date
01-10-2009
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 10/2009
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-1071-0

Other articles of this Issue 10/2009

European Spine Journal 10/2009 Go to the issue