In vivo change of elastic property in polyethylene acetabular components

Authors: Atsushi Kusaba, Saiji Kondo, Yujiro Mori, Yoshikatsu Kuroki

Published in: Modern Rheumatology | Issue 2/2008

Login to get access

Abstract

Polyethylene is an elastic material. It is known that oxidative degradation of polyethylene occurs after sterilization by means of gamma irradiation. However, there have been few detailed reports with regard to the effects of this degradation on the mechanical property, especially in total hip prostheses. The purpose of this study was to examine the change in mechanical property of irradiated and non-irradiated polyethylene cups after implantation. Fifty-six ultra-high molecular-weight polyethylene (UHMWPE) cups retrieved at revision surgery were evaluated. Thirty-two cups were sterilized by gamma irradiation in air and 24 by ethylene oxide gas (EtO). To evaluate the mechanical property of the cup and its regional distribution, Vickers hardness was measured at nine points at the cross-section of the cups. In the irradiated cups, the hardness increased in proportion to the time from sterilization. This phenomenon was not found in the cups sterilized by EtO. Less change of hardness was observed in the cups sterilized by EtO than in those sterilized by irradiation. The gamma-irradiation in air actually affected the elastic property of cup polyethylene in vivo, although any difference in the wear rate was not detected between two sterilization methods. In cases with accelerated wear of the acetabular cup, other factors affecting wear should also be considered.
Literature
1.
go back to reference Schmalzried TP, Clarke IC, McKellop HA. Bearing Surface. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, editors. Philadelphia, New York: Lippincott-Raven; 1998. pp. 247–65. Schmalzried TP, Clarke IC, McKellop HA. Bearing Surface. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, editors. Philadelphia, New York: Lippincott-Raven; 1998. pp. 247–65.
2.
go back to reference Li S. Polyethylene. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, eds. Philadelphia, New York: Lippincott-Raven; 1998. pp. 105–22. Li S. Polyethylene. In: The Adult Hip. Callaghan JJ, Rosenberg AG, Rubash HE, eds. Philadelphia, New York: Lippincott-Raven; 1998. pp. 105–22.
3.
go back to reference Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, et al. Significance of in vivo degradation for polyethylene in total hip arthroplasty. Clin Orthop. 2006;453:47–57.PubMedCrossRef Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, et al. Significance of in vivo degradation for polyethylene in total hip arthroplasty. Clin Orthop. 2006;453:47–57.PubMedCrossRef
4.
go back to reference Eyerer P, Ke YC. Property changes of UHMW polyethylene hip cup endoprostheses during implantation. J Biomed Mater Res. 1984;18:1137–51.PubMedCrossRef Eyerer P, Ke YC. Property changes of UHMW polyethylene hip cup endoprostheses during implantation. J Biomed Mater Res. 1984;18:1137–51.PubMedCrossRef
5.
go back to reference Kurtz SM, Rimnac CM, Hozack WJ, Turner J, Marcolongo M, Goldberg VM, et al. In vivo degradation of polyethylene liners after gamma sterilization in air. J Bone Joint Surg. 2005;87-A:815–23.CrossRef Kurtz SM, Rimnac CM, Hozack WJ, Turner J, Marcolongo M, Goldberg VM, et al. In vivo degradation of polyethylene liners after gamma sterilization in air. J Bone Joint Surg. 2005;87-A:815–23.CrossRef
6.
go back to reference Kurz SM, Bartel DL, Rimnac CM. Postirradiation aging affects stress and strain in polyethylene components. Clin Orthop. 1998;350:209–20. Kurz SM, Bartel DL, Rimnac CM. Postirradiation aging affects stress and strain in polyethylene components. Clin Orthop. 1998;350:209–20.
7.
go back to reference Li S, Burstein AH. Ultra-high molecular weight polyethylene. The material, its use in total joint implants. J Bone, Joint Surg. 1994;76-A:1080–90. Li S, Burstein AH. Ultra-high molecular weight polyethylene. The material, its use in total joint implants. J Bone, Joint Surg. 1994;76-A:1080–90.
8.
go back to reference Ries MD, Weaver K, Beals N. Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin Orthop. 1996;331:159–63.PubMedCrossRef Ries MD, Weaver K, Beals N. Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin Orthop. 1996;331:159–63.PubMedCrossRef
9.
go back to reference Wannomae KK, Bhattacharyya S, Freiberg A, Estok D, Harris WH, Muratoglu O. In vivo oxidation of retrieved cross-linked ultra-high molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty. 2006;21:1005–11.PubMedCrossRef Wannomae KK, Bhattacharyya S, Freiberg A, Estok D, Harris WH, Muratoglu O. In vivo oxidation of retrieved cross-linked ultra-high molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty. 2006;21:1005–11.PubMedCrossRef
10.
go back to reference Ries MD, Weaver K, Rose RM, Gunther J, Sauer W, Beals N. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide. Clin Orthop. 1996;333:87–95.PubMed Ries MD, Weaver K, Rose RM, Gunther J, Sauer W, Beals N. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide. Clin Orthop. 1996;333:87–95.PubMed
11.
go back to reference Watanabe E, Suzuki M, Nagata K, Kaneeda T, Harada Y, Utsumi M, et al. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components. J Biomed Mater Res. 2002;62:540–9.PubMedCrossRef Watanabe E, Suzuki M, Nagata K, Kaneeda T, Harada Y, Utsumi M, et al. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components. J Biomed Mater Res. 2002;62:540–9.PubMedCrossRef
12.
go back to reference Bloebaum RD, Nelson K, Dorr LD, Hofmann AA, Lyman DJ. Investigation of early surface delamination observed in retrieved heat-pressed tibial inserts. Clin Orthop. 1991;269:120–7.PubMed Bloebaum RD, Nelson K, Dorr LD, Hofmann AA, Lyman DJ. Investigation of early surface delamination observed in retrieved heat-pressed tibial inserts. Clin Orthop. 1991;269:120–7.PubMed
13.
go back to reference Mckellop H, Shen FW, Lu B, Campbell P, Salovey R. Effect of sterilization method, other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg. 2000;82-A:1708–25.PubMed Mckellop H, Shen FW, Lu B, Campbell P, Salovey R. Effect of sterilization method, other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg. 2000;82-A:1708–25.PubMed
14.
go back to reference Williams IR, Mayor MB, Collier JP. The impact of sterilization method on wear in knee arthroplasty. Clin Orthop. 1998;356:170–80.PubMedCrossRef Williams IR, Mayor MB, Collier JP. The impact of sterilization method on wear in knee arthroplasty. Clin Orthop. 1998;356:170–80.PubMedCrossRef
15.
go back to reference Wroblewski BM. Direction, rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg. 1985;67-B:757–61. Wroblewski BM. Direction, rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg. 1985;67-B:757–61.
16.
go back to reference Kurtz SM, Rimnac CM, Santner TJ, Bartel DL. Exponential model for the tensile true stress-strain behavior of as-irradiated and oxidatively degraded ultra high molecular weight polyethylene. J Orthop Res. 1996;14:755–61.PubMedCrossRef Kurtz SM, Rimnac CM, Santner TJ, Bartel DL. Exponential model for the tensile true stress-strain behavior of as-irradiated and oxidatively degraded ultra high molecular weight polyethylene. J Orthop Res. 1996;14:755–61.PubMedCrossRef
17.
go back to reference Kurtz SM, Rimnac CM, Bartel DL. Degradation rate of ultra-high molecular weight polyethylene. J Orthop Res. 1997;15:57–61.PubMedCrossRef Kurtz SM, Rimnac CM, Bartel DL. Degradation rate of ultra-high molecular weight polyethylene. J Orthop Res. 1997;15:57–61.PubMedCrossRef
18.
go back to reference Kurtz SM, Hozack W, Marcolongo M, Turner J, Rimnac C, Edidin A. Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplasty. 2003;18(Suppl 1):68–78.PubMedCrossRef Kurtz SM, Hozack W, Marcolongo M, Turner J, Rimnac C, Edidin A. Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplasty. 2003;18(Suppl 1):68–78.PubMedCrossRef
19.
go back to reference Digas G, Thanner J, Nivbrant B, Röhrl S, Ström H, Kärrholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003;74:531–41.PubMedCrossRef Digas G, Thanner J, Nivbrant B, Röhrl S, Ström H, Kärrholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003;74:531–41.PubMedCrossRef
20.
go back to reference Röhrl SM, Nivbrant B, Ström H, Nilsson KG. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty. 2004;19:962–71.PubMed Röhrl SM, Nivbrant B, Ström H, Nilsson KG. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow-up of total hip arthroplasty with RSA. J Arthroplasty. 2004;19:962–71.PubMed
21.
go back to reference Sychterz CJ, Orishimo KF, Engh CA. Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am. 2004;86-A(5):1017–22.PubMed Sychterz CJ, Orishimo KF, Engh CA. Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am. 2004;86-A(5):1017–22.PubMed
22.
go back to reference Oonishi H, Tsuji E, Kim YY. Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear. J Mater Sci Mater Med. 1998;9:393–401.PubMedCrossRef Oonishi H, Tsuji E, Kim YY. Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear. J Mater Sci Mater Med. 1998;9:393–401.PubMedCrossRef
Metadata
Title
In vivo change of elastic property in polyethylene acetabular components
Authors
Atsushi Kusaba
Saiji Kondo
Yujiro Mori
Yoshikatsu Kuroki
Publication date
01-04-2008
Publisher
Springer Japan
Published in
Modern Rheumatology / Issue 2/2008
Print ISSN: 1439-7595
Electronic ISSN: 1439-7609
DOI
https://doi.org/10.1007/s10165-008-0025-4

Other articles of this Issue 2/2008

Modern Rheumatology 2/2008 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.