Skip to main content
Top
Published in: International Journal of Hematology 5/2016

01-05-2016 | Original Article

In vitro alteration of hematological parameters and blood viscosity by the perfluorocarbon: Oxycyte

Authors: Françoise Arnaud, Katherine Sanders, Donna Sieckmann, Paula Moon-Massat

Published in: International Journal of Hematology | Issue 5/2016

Login to get access

Abstract

While perfluorocarbons (PFCs) may be useful in some clinical situations, previous studies have shown that interferences with chemistry analytes can occur with blood samples containing PFCs. This in vitro study focused on how the PFC Oxycyte may affect hematology measurements in blood samples. Swine blood diluted with Oxycyte or saline (Controls) were analyzed for Hemoglobin (Hb), Mean Corpuscular Volume (MCV),Hematocrit (Hct) and Fluorocrit (Fct) using a HemaVet, ABL-735 (ABL), or microhematocrit. Ancillary tests (blood viscosity, electrolytes, cell counts, and red blood cell morphology) were performed secondarily. Increasing Oxycyte resulted in increases in MCV, Hct, and visible cell shape change and morphology vs. Controls. Effects correlated with lower sodium in Oxycyte samples vs. Controls. With increasing Oxycyte, Hb became higher than Controls or became unpredictable depending on the instrument (HemaVet or ABL, respectively). Fct was smaller than predicted and likely represented the heaviest components of Oxycyte. At ≥50 % Oxycyte, RBC hemolysis rendered further measurements impractical. Viscosity first increased then decreased with increasing Oxycyte, peaking at ~40 % Oxycyte. Hct, MCV, Hb, and RBC morphology may be affected by Oxycyte. These observations correlated with lower sodium and increasing Oxycyte, causing hemolysis at high Oxycyte concentrations. These changes were due to alterations in the blood samples in vitro and this should be considered when interpreting hematology parameters from in vivo studies.
Literature
1.
go back to reference Remy B, Deby-Dupont G, Lamy M. Red blood cell substitutes: fluorocarbon emulsions and haemoglobin solutions. Br Med Bull. 1999;55(1):277–98.CrossRefPubMed Remy B, Deby-Dupont G, Lamy M. Red blood cell substitutes: fluorocarbon emulsions and haemoglobin solutions. Br Med Bull. 1999;55(1):277–98.CrossRefPubMed
2.
go back to reference Cabrales P, Carlos Briceno j. Delaying blood transfusion in experimental acute anemia with a perfluorocarbon emulsion. Anesthesiology. 2011;114(4):901–11.CrossRefPubMedPubMedCentral Cabrales P, Carlos Briceno j. Delaying blood transfusion in experimental acute anemia with a perfluorocarbon emulsion. Anesthesiology. 2011;114(4):901–11.CrossRefPubMedPubMedCentral
3.
go back to reference Cuignet OY, Wood BL, Chandler WL, Spiess BD. A second-generation blood substitute (Perfluorodichlorooctane emulsion) generates spurious elevations in platelet counts from automated hematology analyzers. Anesth Analg. 2000;90(3):517–22.CrossRefPubMed Cuignet OY, Wood BL, Chandler WL, Spiess BD. A second-generation blood substitute (Perfluorodichlorooctane emulsion) generates spurious elevations in platelet counts from automated hematology analyzers. Anesth Analg. 2000;90(3):517–22.CrossRefPubMed
4.
go back to reference Spiess BD. Perfluorocarbon emulsions as a promising technology: a review of tissue and vascular gas dynamics. J Appl Physiol. 2009;106(4):1444–52.CrossRefPubMed Spiess BD. Perfluorocarbon emulsions as a promising technology: a review of tissue and vascular gas dynamics. J Appl Physiol. 2009;106(4):1444–52.CrossRefPubMed
5.
go back to reference Mahon RT, Hall A, Bodo M, Auker C. The intravenous perfluorocarbon emulsion Oxycyte does not increase hyperbaric oxygen-related seizures in a non-sedated swine model. Eur J Appl Physiol. 2013;113(11):2795–802.CrossRefPubMed Mahon RT, Hall A, Bodo M, Auker C. The intravenous perfluorocarbon emulsion Oxycyte does not increase hyperbaric oxygen-related seizures in a non-sedated swine model. Eur J Appl Physiol. 2013;113(11):2795–802.CrossRefPubMed
6.
go back to reference Spiess BD. The potential role of perfluorocarbon emulsions in decompression illness. Diving Hyperbaric Med J South Pacific Underwater Med Soc. 2010;40(1):28–33. Spiess BD. The potential role of perfluorocarbon emulsions in decompression illness. Diving Hyperbaric Med J South Pacific Underwater Med Soc. 2010;40(1):28–33.
7.
go back to reference Scultetus AHA, Arnaud F, McNamee G, Dickson L, Auker C, McCarron R, Mahon R. Editor IV perfluorocarbons increased O2 delivery/consumption in ARDS in swine. Crit Care. 2014;2014:17. Scultetus AHA, Arnaud F, McNamee G, Dickson L, Auker C, McCarron R, Mahon R. Editor IV perfluorocarbons increased O2 delivery/consumption in ARDS in swine. Crit Care. 2014;2014:17.
8.
go back to reference Jouan-Hureaux V, Audonnet-Blaise S, Lacatusu D, Krafft MP, Dewachter P, Cauchois G, et al. Effects of a new perfluorocarbon emulsion on human plasma and whole-blood viscosity in the presence of albumin, hydroxyethyl starch, or modified fluid gelatin: an in vitro rheologic approach. Transfusion. 2006;46(11):1892–8.CrossRefPubMed Jouan-Hureaux V, Audonnet-Blaise S, Lacatusu D, Krafft MP, Dewachter P, Cauchois G, et al. Effects of a new perfluorocarbon emulsion on human plasma and whole-blood viscosity in the presence of albumin, hydroxyethyl starch, or modified fluid gelatin: an in vitro rheologic approach. Transfusion. 2006;46(11):1892–8.CrossRefPubMed
9.
go back to reference Rand PW, Barker N, Lacombe E. Effects of plasma viscosity and aggregation on whole-blood viscosity. Am J Physiol. 1970;218(3):681–8.PubMed Rand PW, Barker N, Lacombe E. Effects of plasma viscosity and aggregation on whole-blood viscosity. Am J Physiol. 1970;218(3):681–8.PubMed
10.
go back to reference Shrinivasan S, Eggleton CD. Viscosity of animal erythrocyte suspensions mixed with a perflurocarbon emulsion. Artif Cells Blood Substit Immobil Biotechnol. 2004;32(3):387–400.CrossRefPubMed Shrinivasan S, Eggleton CD. Viscosity of animal erythrocyte suspensions mixed with a perflurocarbon emulsion. Artif Cells Blood Substit Immobil Biotechnol. 2004;32(3):387–400.CrossRefPubMed
11.
go back to reference Lacatusu D, Baican M, Crivoi F. Effects of perfluorocarbon emulsion in rheology. Rev Med Chir Soc Med Nat Iasi. 2014;118(1):232–8.PubMed Lacatusu D, Baican M, Crivoi F. Effects of perfluorocarbon emulsion in rheology. Rev Med Chir Soc Med Nat Iasi. 2014;118(1):232–8.PubMed
12.
go back to reference Ponder E. Relation between red blood cell density and corpuscular hemoglobin concentration. J Biol Chem. 1942; 144. Ponder E. Relation between red blood cell density and corpuscular hemoglobin concentration. J Biol Chem. 1942; 144.
13.
go back to reference Dimeski G. Interference testing. The Clinical biochemist Reviews/Australian Association of Clinical Biochemists. 2008;29(Suppl 1):S43–8.PubMedPubMedCentral Dimeski G. Interference testing. The Clinical biochemist Reviews/Australian Association of Clinical Biochemists. 2008;29(Suppl 1):S43–8.PubMedPubMedCentral
14.
go back to reference Kroll MH, Elin RJ. Interference with clinical laboratory analyses. Clin Chem. 1994;40(11 Pt 1):1996–2005.PubMed Kroll MH, Elin RJ. Interference with clinical laboratory analyses. Clin Chem. 1994;40(11 Pt 1):1996–2005.PubMed
15.
go back to reference Mullins RE, Hutton PS, Conn RB. Effects of Fluosol-DA (artificial blood) on clinical chemistry tests and instruments. Am J Clin Pathol. 1983;80(4):478–83.CrossRefPubMed Mullins RE, Hutton PS, Conn RB. Effects of Fluosol-DA (artificial blood) on clinical chemistry tests and instruments. Am J Clin Pathol. 1983;80(4):478–83.CrossRefPubMed
16.
go back to reference Ma Z, Monk TG, Goodnough LT, McClellan A, Gawryl M, Clark T, et al. Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests. Clin Chem. 1997;43(9):1732–7.PubMed Ma Z, Monk TG, Goodnough LT, McClellan A, Gawryl M, Clark T, et al. Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests. Clin Chem. 1997;43(9):1732–7.PubMed
17.
go back to reference Shepherd AP, Steinke JM. CO-oximetry interference by perflubron emulsion: comparison of hemolyzing and nonhemolyzing instruments. Clin Chem. 1998;44(10):2183–90.PubMed Shepherd AP, Steinke JM. CO-oximetry interference by perflubron emulsion: comparison of hemolyzing and nonhemolyzing instruments. Clin Chem. 1998;44(10):2183–90.PubMed
18.
go back to reference Corliss HPPC. The theory of ORE flotation. J Ind Eng Chem. 1917;9(5):481–8.CrossRef Corliss HPPC. The theory of ORE flotation. J Ind Eng Chem. 1917;9(5):481–8.CrossRef
19.
go back to reference Cabrales P, Tsai AG, Frangos JA, Briceno JC, Intaglietta M. Oxygen delivery and consumption in the microcirculation after extreme hemodilution with perfluorocarbons. Am J Physiol Heart Circ Physiol. 2004;287(1):H320–30.CrossRefPubMed Cabrales P, Tsai AG, Frangos JA, Briceno JC, Intaglietta M. Oxygen delivery and consumption in the microcirculation after extreme hemodilution with perfluorocarbons. Am J Physiol Heart Circ Physiol. 2004;287(1):H320–30.CrossRefPubMed
20.
go back to reference Davidson A. The Penguin Companion to Food 2002. Davidson A. The Penguin Companion to Food 2002.
21.
go back to reference Hoffmann EK, Lambert IH, Pedersen SF. Physiology of cell volume regulation in vertebrates. Physiol Rev. 2009;89(1):193–277.CrossRefPubMed Hoffmann EK, Lambert IH, Pedersen SF. Physiology of cell volume regulation in vertebrates. Physiol Rev. 2009;89(1):193–277.CrossRefPubMed
22.
go back to reference Vasquez DM, Ortiz D, Alvarez OA, Briceno JC, Cabrales P. Hemorheological implications of perfluorocarbon based oxygen carrier interaction with colloid plasma expanders and blood. Biotechnol Prog. 2013;29(3):796–807.CrossRefPubMedPubMedCentral Vasquez DM, Ortiz D, Alvarez OA, Briceno JC, Cabrales P. Hemorheological implications of perfluorocarbon based oxygen carrier interaction with colloid plasma expanders and blood. Biotechnol Prog. 2013;29(3):796–807.CrossRefPubMedPubMedCentral
23.
go back to reference Gregersen MI, Chien S, Peric B, Taylor H. Investigations of viscosity at low rates of shear: effects of variations in the concentration and character of the red cells and in the composition of the suspending medium. Bibliotheca Anatomica. 1965;7:383–4.PubMed Gregersen MI, Chien S, Peric B, Taylor H. Investigations of viscosity at low rates of shear: effects of variations in the concentration and character of the red cells and in the composition of the suspending medium. Bibliotheca Anatomica. 1965;7:383–4.PubMed
Metadata
Title
In vitro alteration of hematological parameters and blood viscosity by the perfluorocarbon: Oxycyte
Authors
Françoise Arnaud
Katherine Sanders
Donna Sieckmann
Paula Moon-Massat
Publication date
01-05-2016
Publisher
Springer Japan
Published in
International Journal of Hematology / Issue 5/2016
Print ISSN: 0925-5710
Electronic ISSN: 1865-3774
DOI
https://doi.org/10.1007/s12185-016-1955-9

Other articles of this Issue 5/2016

International Journal of Hematology 5/2016 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine