Abstract

Purpose

Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only.

Methods

A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs.

Results

Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17 and 34 % of the knees in group 1 and group 2, respectively (p = 0.04). A malalignment of the tibial component >3° was found in 34 % of knees in group 1 compared with 4 % of those in group 2 (p = 0.0001).

Conclusions

Coronal alignment of the tibial component may improve by setting the extramedullary rod in line with anatomical references in the proximal tibia only. This technique appears to bypass the influence of tibial torsion on the alignment of the extramedullary guide at the distal tibia. The clinical relevance of the study is that using this technique, the rate of malalignment of the tibial component may be reduced compared to a standard technique in which a fixed reference is used at the ankle joint.
Literature
1.
go back to reference Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755PubMedCentralCrossRefPubMed Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751–2755PubMedCentralCrossRefPubMed
2.
go back to reference Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRefPubMed Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C (2004) An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 420:213–219CrossRefPubMed
3.
go back to reference Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRefPubMed Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRefPubMed
4.
go back to reference Benjamin J (2006) Component alignment in total knee arthroplasty. Am Acad Orthop Surg Instr Course Lect 55:405–412 Benjamin J (2006) Component alignment in total knee arthroplasty. Am Acad Orthop Surg Instr Course Lect 55:405–412
5.
go back to reference Chiu KY, Yau WP, Ng TP, Tang WM (2008) The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty. Int Orthop 32:467–471PubMedCentralCrossRefPubMed Chiu KY, Yau WP, Ng TP, Tang WM (2008) The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty. Int Orthop 32:467–471PubMedCentralCrossRefPubMed
6.
go back to reference Cinotti G, Sessa P, Rocca AD, Ripani FR, Giannicola G (2013) Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty. Acta Orthop 84:275–279PubMedCentralCrossRefPubMed Cinotti G, Sessa P, Rocca AD, Ripani FR, Giannicola G (2013) Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty. Acta Orthop 84:275–279PubMedCentralCrossRefPubMed
7.
go back to reference Cobb JP, Dixon H, Dandachli W, Iranpour F (2008) The anatomical tibial axis: reliable rotational orientation in knee replacement. J Bone Joint Surg (Br) 90:1032–1038CrossRef Cobb JP, Dixon H, Dandachli W, Iranpour F (2008) The anatomical tibial axis: reliable rotational orientation in knee replacement. J Bone Joint Surg (Br) 90:1032–1038CrossRef
8.
go back to reference Dennis DA, Channer M, Susman MH, Stringer EA (1993) Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. J Arthroplasty 8:43–47CrossRefPubMed Dennis DA, Channer M, Susman MH, Stringer EA (1993) Intramedullary versus extramedullary tibial alignment systems in total knee arthroplasty. J Arthroplasty 8:43–47CrossRefPubMed
9.
go back to reference Dexel J, Kirschner S, Klaus-Günther K-P, Lützner J (2013) Agreement between radiological and computer navigation measurement of lower limb alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2599-4 Dexel J, Kirschner S, Klaus-Günther K-P, Lützner J (2013) Agreement between radiological and computer navigation measurement of lower limb alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2599-4
10.
go back to reference Eckhoff DG, Johnson KK (1994) Three-dimensional computed tomography reconstruction of tibial torsion. Clin Orthop Relat Res 302:42–46PubMed Eckhoff DG, Johnson KK (1994) Three-dimensional computed tomography reconstruction of tibial torsion. Clin Orthop Relat Res 302:42–46PubMed
11.
go back to reference Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
12.
go back to reference Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: Just how important is it? J Arthroplasty 24(Suppl 6):39–43CrossRefPubMed Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: Just how important is it? J Arthroplasty 24(Suppl 6):39–43CrossRefPubMed
13.
go back to reference Green GV, Berend KR, Berend ME, Glisson RR, Vail TP (2002) The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty 17:1033–1039CrossRefPubMed Green GV, Berend KR, Berend ME, Glisson RR, Vail TP (2002) The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty 17:1033–1039CrossRefPubMed
14.
go back to reference Heyse TJ, Decking R, Davis J, Boettner F, Laskin RS (2009) Varus gonarthrosis predisposes to varus malalignment in TKA. HSSJ 5:143–148CrossRef Heyse TJ, Decking R, Davis J, Boettner F, Laskin RS (2009) Varus gonarthrosis predisposes to varus malalignment in TKA. HSSJ 5:143–148CrossRef
15.
go back to reference Hovinga KR, Lerner AL (2009) Anatomic variations between Japanese and Caucasian populations in the healthy young adult knee joint. J Orthop Res 27:1191–1196CrossRefPubMed Hovinga KR, Lerner AL (2009) Anatomic variations between Japanese and Caucasian populations in the healthy young adult knee joint. J Orthop Res 27:1191–1196CrossRefPubMed
16.
go back to reference Hsu HP, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res 248:135–144PubMed Hsu HP, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res 248:135–144PubMed
17.
go back to reference Huddleston JL, Scott RD, Wimberley DW (2005) Determination of neutral tibial rotational alignment in rotating platform TKA. Clin Orthop Relat Res 440:101–106CrossRefPubMed Huddleston JL, Scott RD, Wimberley DW (2005) Determination of neutral tibial rotational alignment in rotating platform TKA. Clin Orthop Relat Res 440:101–106CrossRefPubMed
18.
go back to reference Ishii Y, Ohmori G, Bechtold JE, Gustilo RB (1995) Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res 318:167–175PubMed Ishii Y, Ohmori G, Bechtold JE, Gustilo RB (1995) Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res 318:167–175PubMed
19.
go back to reference Jakob RP, Haertel M, Stussi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurement. J Bone Joint Surg 62-B:238–242 Jakob RP, Haertel M, Stussi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurement. J Bone Joint Surg 62-B:238–242
20.
go back to reference Ko PS, Tio MK, Ban CM, Mak YK, Ip FK, Lam JJ (2001) Radiologic analysis of the tibial intramedullary canal in Chinese varus knees. Implications in total knee arthroplasty. J Arthroplasty 16:212–215CrossRefPubMed Ko PS, Tio MK, Ban CM, Mak YK, Ip FK, Lam JJ (2001) Radiologic analysis of the tibial intramedullary canal in Chinese varus knees. Implications in total knee arthroplasty. J Arthroplasty 16:212–215CrossRefPubMed
21.
go back to reference Kim D, Seong SC, Lee MC, Lee S (2012) Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:337–345CrossRefPubMed Kim D, Seong SC, Lee MC, Lee S (2012) Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:337–345CrossRefPubMed
22.
go back to reference Lützner J, Krummenauer F, Günther KP, Kirschner S (2010) Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 11:57PubMedCentralCrossRefPubMed Lützner J, Krummenauer F, Günther KP, Kirschner S (2010) Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border. BMC Musculoskelet Disord 11:57PubMedCentralCrossRefPubMed
23.
go back to reference Maestro A, Harwin SF, Sandoval MG, Vaguero DH, Murcia A (1998) Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty 13(5):552–558CrossRefPubMed Maestro A, Harwin SF, Sandoval MG, Vaguero DH, Murcia A (1998) Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. J Arthroplasty 13(5):552–558CrossRefPubMed
24.
go back to reference Mihalko WM, Krackow KA (2006) Differences between extramedullary, intramedullary and computer-aided surgery tibial alignment techniques for total knee arthroplasty. J Knee Surg 19:33–36PubMed Mihalko WM, Krackow KA (2006) Differences between extramedullary, intramedullary and computer-aided surgery tibial alignment techniques for total knee arthroplasty. J Knee Surg 19:33–36PubMed
25.
go back to reference Mizu-uchi H, Matsuda S, Miura H, Hikagi H, Okazaki K, Iwamoto Y (2006) The effect of ankle rotation on cutting of the tibia in total knee arthroplasty. J Bone Joint Surg 88-A:2632–2636CrossRef Mizu-uchi H, Matsuda S, Miura H, Hikagi H, Okazaki K, Iwamoto Y (2006) The effect of ankle rotation on cutting of the tibia in total knee arthroplasty. J Bone Joint Surg 88-A:2632–2636CrossRef
26.
go back to reference Mowlavi A, Whiteman J, Wilhelmi BJ, Neumeister MW, McLafferty R (2002) Dorsalis pedis arterial pulse: palpation using a bony landmark. Postgrad Med J 78:746–747PubMedCentralCrossRefPubMed Mowlavi A, Whiteman J, Wilhelmi BJ, Neumeister MW, McLafferty R (2002) Dorsalis pedis arterial pulse: palpation using a bony landmark. Postgrad Med J 78:746–747PubMedCentralCrossRefPubMed
27.
go back to reference Nagamine R, Miura H, Bravo C, Urabe K, Matsuda S, Miyanishi K, Hirata G, Iwamoto Y (2000) Anatomic variation should be considered in total knee arthroplasty. J Orthop Sci 5:232–237CrossRefPubMed Nagamine R, Miura H, Bravo C, Urabe K, Matsuda S, Miyanishi K, Hirata G, Iwamoto Y (2000) Anatomic variation should be considered in total knee arthroplasty. J Orthop Sci 5:232–237CrossRefPubMed
28.
go back to reference Nagamine R, Miyanishi K, Miura H, Urabe K, Matsuda S, Iwamoto Y (2003) Medial torsion of the tibia in Japanese patients with osteoarthritis of the knee. Clin Orthop Relat Res 408:218–224CrossRefPubMed Nagamine R, Miyanishi K, Miura H, Urabe K, Matsuda S, Iwamoto Y (2003) Medial torsion of the tibia in Japanese patients with osteoarthritis of the knee. Clin Orthop Relat Res 408:218–224CrossRefPubMed
29.
go back to reference Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895–902PubMedCentralCrossRefPubMed Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895–902PubMedCentralCrossRefPubMed
30.
go back to reference Parker Vail T, Lang JE (2006) Surgical techniques and instrumentation in total knee arthroplasty. In: Scott WN (ed) Insall and scott surgery of the knee, vol 1. Churchill Livingstone, Elsevier, Philadelphia, pp 1455–1521 Parker Vail T, Lang JE (2006) Surgical techniques and instrumentation in total knee arthroplasty. In: Scott WN (ed) Insall and scott surgery of the knee, vol 1. Churchill Livingstone, Elsevier, Philadelphia, pp 1455–1521
31.
go back to reference Patil S, D’Lima DD, Fait JM, Colwell CW Jr (2007) Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device. J Bone Joint Surg 89-A:381–387CrossRefPubMed Patil S, D’Lima DD, Fait JM, Colwell CW Jr (2007) Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device. J Bone Joint Surg 89-A:381–387CrossRefPubMed
32.
go back to reference Perillo-Mercone A, Taylor M (2007) Effect of varus/valgus malalignment on bone strains in the proximal tibia after an explicit finite element study. J Biomech Eng 129:1–11CrossRef Perillo-Mercone A, Taylor M (2007) Effect of varus/valgus malalignment on bone strains in the proximal tibia after an explicit finite element study. J Biomech Eng 129:1–11CrossRef
33.
go back to reference Reed MR, Bliss W, Sher JL, Emmerson KP, Jones SM, Partington PF (2002) Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. J Bone Joint Surg 84-B:858–860CrossRef Reed MR, Bliss W, Sher JL, Emmerson KP, Jones SM, Partington PF (2002) Extramedullary or intramedullary tibial alignment guides: a randomised, prospective trial of radiological alignment. J Bone Joint Surg 84-B:858–860CrossRef
34.
go back to reference Sasanuma H, Hitoshi Sekiya H, Takatoku K, Ajiki T, Hagiwara H (2014) Accuracy of a proximal tibial cutting method using the anterior tibial border in TKA. Eur J Orthop Surg Traumatol. doi:10.1007/s00590-014-1415-2 PubMed Sasanuma H, Hitoshi Sekiya H, Takatoku K, Ajiki T, Hagiwara H (2014) Accuracy of a proximal tibial cutting method using the anterior tibial border in TKA. Eur J Orthop Surg Traumatol. doi:10.​1007/​s00590-014-1415-2 PubMed
35.
go back to reference Schneider M, Heisel C, Aldinger PR, Breusch SJ (2007) Use of palpable tendons for extramedullary tibial alignment in total knee arthroplasty. J Arthroplasty 22:219–226CrossRefPubMed Schneider M, Heisel C, Aldinger PR, Breusch SJ (2007) Use of palpable tendons for extramedullary tibial alignment in total knee arthroplasty. J Arthroplasty 22:219–226CrossRefPubMed
36.
go back to reference Strecker W, Keppler P, Gebhard F, Kinzl L (1997) Length and torsion of the lower limb. J Bone Joint Surg 79-B:1019–1023CrossRef Strecker W, Keppler P, Gebhard F, Kinzl L (1997) Length and torsion of the lower limb. J Bone Joint Surg 79-B:1019–1023CrossRef
37.
go back to reference Sugimura N, Ikeuchi M, Izumi M, Aso K, Ushida T, Tani T (2013) The dorsal pedis artery as a new distal landmark for extramedullary tibial alignment in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2461-8 Sugimura N, Ikeuchi M, Izumi M, Aso K, Ushida T, Tani T (2013) The dorsal pedis artery as a new distal landmark for extramedullary tibial alignment in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2461-8
38.
go back to reference Takai S, Sakakida K, Yamashita F, Suzu F, Izuta F (1985) Rotational alignment of the lower limb in osteoarthritis of the knee. Int Orthop 9:209–215CrossRefPubMed Takai S, Sakakida K, Yamashita F, Suzu F, Izuta F (1985) Rotational alignment of the lower limb in osteoarthritis of the knee. Int Orthop 9:209–215CrossRefPubMed
39.
go back to reference Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop Relat Res 321:106–110PubMed Teter KE, Bregman D, Colwell CW Jr (1995) Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop Relat Res 321:106–110PubMed
Metadata
Title
Improving tibial component alignment in total knee arthroplasty
Authors
G. Cinotti
P. Sessa
A. D’Arino
F. R. Ripani
G. Giannicola
Publication date
01-12-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 12/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3236-6

Other articles of this Issue 12/2015

Knee Surgery, Sports Traumatology, Arthroscopy 12/2015 Go to the issue