Background

Correct rotational alignment of the femoral and tibial component is an important factor for successful TKA. The transepicondylar axis is widely accepted as a reference for the femoral component. There is not a standard reference for the tibial component. CT scans were used in this study to measure which of 2 tibial landmarks most reliably reproduces a correct femoro-tibial rotational alignment in TKA.

Methods

80 patients received a cemented, unconstrained, cruciate-retaining TKA with a rotating platform. CT scans were performed 5-7 days postoperatively but before discharge. The rotational mismatch between the femoral and tibial components was measured. Furthermore, the rotational variance between the transepicondylar line, as a reference for the orientation of the femoral component and different tibial landmarks, was measured.

Results

There was notable rotational mismatch between the femoral and tibial components. The median mismatch was 0° (range: 16.2 degrees relative external to 14.4 degrees relative internal rotation of the femoral component).
Using the transepicondylar line as a reference for femoral rotational alignment and the medial third of the tuberosity as a reference for tibial rotational alignment, 67.5% of all TKA had a femoro-tibial variance within ± 5 degrees, 85% within ± 10 degrees and 97.5% within ± 20 degrees. Using the medial border of the tibial tubercle as a reference this variance was greater, only 3.8% had a femoro-tibial variance within ± 5 degrees, 15% within ± 10 degrees and 68.8% within ± 20 degrees.

Conclusion

Using fixed bone landmarks for rotational alignment leads to a notable variance between femoral and tibial components. Referencing the tibial rotation on a line from the medial third of the tibial tubercle to the center of the tibial tray resulted in a better femoro-tibial rotational alignment than using the medial border of tibial tubercle as a landmark. Surgeons using fixed bearings with a high rotational constraint between the inlay and the femoral component should be aware of this effect to avoid premature polyethylene wear.

Trial Registration

Clinical trials registry NCT01022099
Appendix
Available only for authorised users
Literature
1.
go back to reference Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L: Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res. 2001, 46-10.1097/00003086-200111000-00006. 392 Barrack RL, Schrader T, Bertot AJ, Wolfe MW, Myers L: Component rotation and anterior knee pain after total knee arthroplasty. Clin Orthop Relat Res. 2001, 46-10.1097/00003086-200111000-00006. 392
2.
go back to reference Berger RA, Crossett LS, Jacobs JJ, Rubash HE: Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop. 1998, 144-356 Berger RA, Crossett LS, Jacobs JJ, Rubash HE: Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop. 1998, 144-356
3.
go back to reference Hofmann S, Romero J, Roth-Schiffl E, Albrecht T: [Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty]. Orthopade. 2003, 32 (6): 469-PubMed Hofmann S, Romero J, Roth-Schiffl E, Albrecht T: [Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty]. Orthopade. 2003, 32 (6): 469-PubMed
4.
go back to reference Insall JN, Scuderi GR, Komistek RD, Math K, Dennis DA, Anderson DT: Correlation between condylar lift-off and femoral component alignment. Clin Orthop Relat Res. 2002, 143-10.1097/00003086-200210000-00022. 403 Insall JN, Scuderi GR, Komistek RD, Math K, Dennis DA, Anderson DT: Correlation between condylar lift-off and femoral component alignment. Clin Orthop Relat Res. 2002, 143-10.1097/00003086-200210000-00022. 403
5.
go back to reference Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994, 31-299 Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG: Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994, 31-299
6.
go back to reference Romero J, Stahelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O: The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplasty. 2007, 22 (2): 235-10.1016/j.arth.2006.04.024.CrossRefPubMed Romero J, Stahelin T, Binkert C, Pfirrmann C, Hodler J, Kessler O: The clinical consequences of flexion gap asymmetry in total knee arthroplasty. J Arthroplasty. 2007, 22 (2): 235-10.1016/j.arth.2006.04.024.CrossRefPubMed
7.
go back to reference Incavo SJ, Wild JJ, Coughlin KM, Beynnon BD: Early Revision for Component Malrotation in Total Knee Arthroplasty. Clin Orthop Relat Res. 2007, 458: 131-6.PubMed Incavo SJ, Wild JJ, Coughlin KM, Beynnon BD: Early Revision for Component Malrotation in Total Knee Arthroplasty. Clin Orthop Relat Res. 2007, 458: 131-6.PubMed
8.
go back to reference Kessler O, Lacatusu E, Sommers MB, Mayr E, Bottlang M: Malrotation in total knee arthroplasty: Effect on tibial cortex strain captured by laser-based strain acquisition. Clin Biomech (Bristol, Avon). 2006, 21 (6): 603-9. 10.1016/j.clinbiomech.2006.01.011.CrossRef Kessler O, Lacatusu E, Sommers MB, Mayr E, Bottlang M: Malrotation in total knee arthroplasty: Effect on tibial cortex strain captured by laser-based strain acquisition. Clin Biomech (Bristol, Avon). 2006, 21 (6): 603-9. 10.1016/j.clinbiomech.2006.01.011.CrossRef
9.
go back to reference Asano T, Akagi M, Nakamura T: The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty. 2005, 20 (8): 1060-10.1016/j.arth.2004.08.005.CrossRefPubMed Asano T, Akagi M, Nakamura T: The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique. J Arthroplasty. 2005, 20 (8): 1060-10.1016/j.arth.2004.08.005.CrossRefPubMed
10.
go back to reference Churchill DL, Incavo SJ, Johnson CC, Beynnon BD: The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998, 111-10.1097/00003086-199811000-00016. 356 Churchill DL, Incavo SJ, Johnson CC, Beynnon BD: The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res. 1998, 111-10.1097/00003086-199811000-00016. 356
11.
go back to reference Miller MC, Berger RA, Petrella AJ, Karmas A, Rubash HE: Optimizing femoral component rotation in total knee arthroplasty. Clin Orthop. 2001, 38-392 Miller MC, Berger RA, Petrella AJ, Karmas A, Rubash HE: Optimizing femoral component rotation in total knee arthroplasty. Clin Orthop. 2001, 38-392
12.
go back to reference Olcott CW, Scott RD: The Ranawat Award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res. 1999, 39-367 Olcott CW, Scott RD: The Ranawat Award. Femoral component rotation during total knee arthroplasty. Clin Orthop Relat Res. 1999, 39-367
13.
go back to reference Olcott CW, Scott RD: A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplasty. 2000, 15 (1): 22-10.1016/S0883-5403(00)91051-9.CrossRefPubMed Olcott CW, Scott RD: A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty. J Arthroplasty. 2000, 15 (1): 22-10.1016/S0883-5403(00)91051-9.CrossRefPubMed
14.
go back to reference Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C: Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res. 2005, 172-10.1097/01.blo.0000160027.52481.32. 436 Akagi M, Mori S, Nishimura S, Nishimura A, Asano T, Hamanishi C: Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res. 2005, 172-10.1097/01.blo.0000160027.52481.32. 436
15.
go back to reference Romero J, Stahelin T, Wyss T, Hofmann S: [Significance of axial rotation alignment of components of knee prostheses]. Orthopade. 2003, 32 (6): 461-PubMed Romero J, Stahelin T, Wyss T, Hofmann S: [Significance of axial rotation alignment of components of knee prostheses]. Orthopade. 2003, 32 (6): 461-PubMed
16.
go back to reference Eckhoff DG, Metzger RG, Vandewalle MV: Malrotation associated with implant alignment technique in total knee arthroplasty. Clin Orthop Relat Res. 1995, 28-321 Eckhoff DG, Metzger RG, Vandewalle MV: Malrotation associated with implant alignment technique in total knee arthroplasty. Clin Orthop Relat Res. 1995, 28-321
17.
go back to reference Huddleston JI, Scott RD, Wimberley DW: Determination of neutral tibial rotational alignment in rotating platform TKA. Clin Orthop Relat Res. 2005, 440: 101-10.1097/01.blo.0000185448.43622.77.CrossRefPubMed Huddleston JI, Scott RD, Wimberley DW: Determination of neutral tibial rotational alignment in rotating platform TKA. Clin Orthop Relat Res. 2005, 440: 101-10.1097/01.blo.0000185448.43622.77.CrossRefPubMed
18.
go back to reference Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y: Bone anatomy and rotational alignment in total knee arthroplasty. Clin Orthop. 2002, 196-402 Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y: Bone anatomy and rotational alignment in total knee arthroplasty. Clin Orthop. 2002, 196-402
19.
go back to reference Lützner J, Krummenauer F, Wolf C, Günther K-P, Kirschner S: Computer-assisted and conventional total knee arthroplasty - A prospective, randomized study with radiographic and CT evaluations. J Bone Joint Surg Br. 2008, 90-B (8): 1039-10.1302/0301-620X.90B8.20553.CrossRef Lützner J, Krummenauer F, Wolf C, Günther K-P, Kirschner S: Computer-assisted and conventional total knee arthroplasty - A prospective, randomized study with radiographic and CT evaluations. J Bone Joint Surg Br. 2008, 90-B (8): 1039-10.1302/0301-620X.90B8.20553.CrossRef
20.
go back to reference Bindelglass DF, Cohen JL, Dorr LD: Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design. Clin Orthop Relat Res. 1993, 103-286 Bindelglass DF, Cohen JL, Dorr LD: Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design. Clin Orthop Relat Res. 1993, 103-286
21.
go back to reference Bindelglass DF: Rotational alignment of the tibial component in total knee arthroplasty. Orthopedics. 2001, 24 (11): 1049-PubMed Bindelglass DF: Rotational alignment of the tibial component in total knee arthroplasty. Orthopedics. 2001, 24 (11): 1049-PubMed
22.
go back to reference Incavo SJ, Coughlin KM, Pappas C, Beynnon BD: Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty. J Arthroplasty. 2003, 18 (5): 643-10.1016/S0883-5403(03)00197-9.CrossRefPubMed Incavo SJ, Coughlin KM, Pappas C, Beynnon BD: Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty. J Arthroplasty. 2003, 18 (5): 643-10.1016/S0883-5403(03)00197-9.CrossRefPubMed
23.
go back to reference Cobb JP, Dixon H, Dandachli W, Iranpour F: The anatomical tibial axis - reliable rotational orientation in knee replacement. J Bone Joint Surg Br. 2008, 90 (8): 1032-10.1302/0301-620X.90B8.19905.CrossRefPubMed Cobb JP, Dixon H, Dandachli W, Iranpour F: The anatomical tibial axis - reliable rotational orientation in knee replacement. J Bone Joint Surg Br. 2008, 90 (8): 1032-10.1302/0301-620X.90B8.19905.CrossRefPubMed
24.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C: A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007, 89 (2): 236-10.2106/JBJS.F.00386.CrossRefPubMed Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C: A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am. 2007, 89 (2): 236-10.2106/JBJS.F.00386.CrossRefPubMed
25.
go back to reference Chauhan SK, Scott RG, Breidahl W, Beaver RJ: Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br. 2004, 86 (3): 372-10.1302/0301-620X.86B3.14643.CrossRefPubMed Chauhan SK, Scott RG, Breidahl W, Beaver RJ: Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br. 2004, 86 (3): 372-10.1302/0301-620X.86B3.14643.CrossRefPubMed
Metadata
Title
Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
Authors
Jörg Lützner
Frank Krummenauer
Klaus-Peter Günther
Stephan Kirschner
Publication date
01-12-2010
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2010
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-11-57

Other articles of this Issue 1/2010

BMC Musculoskeletal Disorders 1/2010 Go to the issue