Skip to main content
Top
Published in: Journal of Digital Imaging 4/2009

01-08-2009

Implementation of a Semi-automated Post-processing System for Parametric MRI Mapping of Human Breast Cancer

Authors: Robert E. Lee, E. Brian Welch, Jared G. Cobb, Tuhin Sinha, John C. Gore, Thomas E. Yankeelov

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2009

Login to get access

Abstract

Magnetic resonance imaging (MRI) investigations of breast cancer incorporate computationally intense techniques to develop parametric maps of pathophysiological tissue characteristics. Common approaches employ, for example, quantitative measurements of T 1, the apparent diffusion coefficient, and kinetic modeling based on dynamic contrast-enhanced MRI (DCE-MRI). In this paper, an integrated medical image post-processing and archive system (MIPAS) is presented. MIPAS demonstrates how image post-processing and user interface programs, written in the interactive data language (IDL) programming language with data storage provided by a Microsoft Access database, and the file system can reduce turnaround time for creating MRI parametric maps and provide additional organization for clinical trials. The results of developing the MIPAS are discussed including potential limitations of the use of IDL for the application framework and how the MIPAS design supports extension to other programming languages and imaging modalities. We also show that network storage of images and metadata has a significant (p < 0.05) increase in data retrieval time compared to collocated storage. The system shows promise for becoming both a robust research picture archival and communications system working with the standard hospital PACS and an image post-processing environment that extends to other medical image modalities.
Literature
3.
go back to reference Bollet MA, Thibault F, Bouillon K, Meunier M, Sigal-Zafrani B, Savignoni A, Diéras V, Nos C, Salmon R, Fourquet A, Institut Curie Breast Cancer Study Group: Role of dynamic magnetic resonance imaging in the evaluation of tumor response to preoperative concurrent radiochemotherapy for large breast cancers: a prospective phase II study. Int J Radiat Oncol Biol Phys 69:13–18, 2007PubMed Bollet MA, Thibault F, Bouillon K, Meunier M, Sigal-Zafrani B, Savignoni A, Diéras V, Nos C, Salmon R, Fourquet A, Institut Curie Breast Cancer Study Group: Role of dynamic magnetic resonance imaging in the evaluation of tumor response to preoperative concurrent radiochemotherapy for large breast cancers: a prospective phase II study. Int J Radiat Oncol Biol Phys 69:13–18, 2007PubMed
4.
go back to reference Chou CP, Wu MT, Chang HT, Lo YS, Pan HB, Degani H, Furman-Haran E: Monitoring breast cancer response to neoadjuvant systemic chemotherapy using parametric contrast-enhanced MRI: a pilot study. Acad Radiol 14(5):561–73, 2007PubMedCrossRef Chou CP, Wu MT, Chang HT, Lo YS, Pan HB, Degani H, Furman-Haran E: Monitoring breast cancer response to neoadjuvant systemic chemotherapy using parametric contrast-enhanced MRI: a pilot study. Acad Radiol 14(5):561–73, 2007PubMedCrossRef
5.
go back to reference Furman-Haran E, Degani H: Parametric analysis of breast MRI. J Comput Assist Tomogr 26(3):376–386, 2002PubMedCrossRef Furman-Haran E, Degani H: Parametric analysis of breast MRI. J Comput Assist Tomogr 26(3):376–386, 2002PubMedCrossRef
6.
go back to reference Gillies RJ, Raghunand N, Karczmar GS, Bhujwalla ZM: MRI of the tumor microenvironment. J Magn Reson Imaging 16:430–450, 2002PubMedCrossRef Gillies RJ, Raghunand N, Karczmar GS, Bhujwalla ZM: MRI of the tumor microenvironment. J Magn Reson Imaging 16:430–450, 2002PubMedCrossRef
7.
go back to reference Pickles MD, Gibbs P, Lowry M, Turnbull LW: Diffusion changes precede size reduction in neoadjuvant treatment of breast cancer. Magn Reson Imaging 24(7):843–847, 2006PubMedCrossRef Pickles MD, Gibbs P, Lowry M, Turnbull LW: Diffusion changes precede size reduction in neoadjuvant treatment of breast cancer. Magn Reson Imaging 24(7):843–847, 2006PubMedCrossRef
8.
go back to reference Yankeelov TE, Lepage M, Chakravarthy A, Broome EE, Niermann KJ, Kelley MC, Meszoely I, Mayer IA, Herman CR, McManus K, Price RR, Gore JC: Integration of quantitative DCE-MRI and ADC mapping to monitor treatment response in human breast cancer: initial results. Magn Reson Imaging 25(1):1–13, 2007PubMedCrossRef Yankeelov TE, Lepage M, Chakravarthy A, Broome EE, Niermann KJ, Kelley MC, Meszoely I, Mayer IA, Herman CR, McManus K, Price RR, Gore JC: Integration of quantitative DCE-MRI and ADC mapping to monitor treatment response in human breast cancer: initial results. Magn Reson Imaging 25(1):1–13, 2007PubMedCrossRef
9.
go back to reference Sotak CH: Nuclear magnetic resonance (NMR) measurement of the apparent diffusion coefficient (ADC) of tissue water and its relationship to cell volume changes in pathological states. Neurochem Int 45:569–582, 2004PubMedCrossRef Sotak CH: Nuclear magnetic resonance (NMR) measurement of the apparent diffusion coefficient (ADC) of tissue water and its relationship to cell volume changes in pathological states. Neurochem Int 45:569–582, 2004PubMedCrossRef
10.
go back to reference Murase K: Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging. Magn Reson Med 51:858–862, 2004PubMedCrossRef Murase K: Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging. Magn Reson Med 51:858–862, 2004PubMedCrossRef
11.
go back to reference Roberts C, Issa B, Stone A, Jackson A, Waterton JC, Parker GJ: Comparative study into the robustness of compartmental modeling and model-free analysis in DCE-MRI studies. J Magn Reson Imaging 23(4):554–563, 2006PubMedCrossRef Roberts C, Issa B, Stone A, Jackson A, Waterton JC, Parker GJ: Comparative study into the robustness of compartmental modeling and model-free analysis in DCE-MRI studies. J Magn Reson Imaging 23(4):554–563, 2006PubMedCrossRef
12.
go back to reference Horsfield MA, Morgan B: Algorithms for calculation of kinetic parameters from T1-weighted dynamic contrast-enhanced magnetic imaging. J Magn Reson Imaging 20:723–729, 2004PubMedCrossRef Horsfield MA, Morgan B: Algorithms for calculation of kinetic parameters from T1-weighted dynamic contrast-enhanced magnetic imaging. J Magn Reson Imaging 20:723–729, 2004PubMedCrossRef
13.
go back to reference Jacobs MA, Barker PB, Argani P, Ouwerkerk R, Bhujwalla ZM, Bluemke DA: Combined dynamic contrast enhanced breast MR and proton spectroscopic imaging: a feasibility study. J Magn Reson Imaging 21:23–28, 2005PubMedCrossRef Jacobs MA, Barker PB, Argani P, Ouwerkerk R, Bhujwalla ZM, Bluemke DA: Combined dynamic contrast enhanced breast MR and proton spectroscopic imaging: a feasibility study. J Magn Reson Imaging 21:23–28, 2005PubMedCrossRef
14.
go back to reference Port RE, Knopp MV, Hoffmann U, Milker-Zabel S, Brix G: Multicompartment analysis of gadolinium chelate kinetics: blood-tissue exchange in mammary tumors as monitored by dynamic MR imaging. J Magn Reson Imaging 10:233–241, 1999PubMedCrossRef Port RE, Knopp MV, Hoffmann U, Milker-Zabel S, Brix G: Multicompartment analysis of gadolinium chelate kinetics: blood-tissue exchange in mammary tumors as monitored by dynamic MR imaging. J Magn Reson Imaging 10:233–241, 1999PubMedCrossRef
15.
go back to reference Neff T, Kiessling F, Brix G, Baudendistel K, Zechmann C, Giesel FL, Bendl R: An optimized workflow for the integration of biological information into the radiotherapy planning: experiences with T1w DCE-MRI. Phys Med Biol 50:4209–4223, 2005PubMedCrossRef Neff T, Kiessling F, Brix G, Baudendistel K, Zechmann C, Giesel FL, Bendl R: An optimized workflow for the integration of biological information into the radiotherapy planning: experiences with T1w DCE-MRI. Phys Med Biol 50:4209–4223, 2005PubMedCrossRef
17.
go back to reference Lowe HJ, Buchanan BG, Cooper GF, Vries JK: Building a medical multimedia database system to integrate clinical information: an application of high-performance computing and communications technology. Bull Med Libr Assoc 83(1):57–64, 1995PubMed Lowe HJ, Buchanan BG, Cooper GF, Vries JK: Building a medical multimedia database system to integrate clinical information: an application of high-performance computing and communications technology. Bull Med Libr Assoc 83(1):57–64, 1995PubMed
18.
go back to reference Wong TC, Huang HK: Design methods and architectural issues of integrated medical image data base systems. Comput Med Imaging Graph 20(4):285–299, 1996PubMedCrossRef Wong TC, Huang HK: Design methods and architectural issues of integrated medical image data base systems. Comput Med Imaging Graph 20(4):285–299, 1996PubMedCrossRef
19.
go back to reference Minati L, Ghielmetti F, Ciobanu V, D’Incerti L, Maccagnano C, Bizzi A, Bruzzone MG: Bio-Image Warehouse System: concept and implementation of a diagnosis-based data warehouse for advanced imaging modalities in neuroradiology. J Digit Imaging 20(1):32–41, 2007PubMedCrossRef Minati L, Ghielmetti F, Ciobanu V, D’Incerti L, Maccagnano C, Bizzi A, Bruzzone MG: Bio-Image Warehouse System: concept and implementation of a diagnosis-based data warehouse for advanced imaging modalities in neuroradiology. J Digit Imaging 20(1):32–41, 2007PubMedCrossRef
20.
go back to reference Hsiao CH, Hsu TC, Chang JN, Yang SJH, Young ST, Chu WC: Developing a medical image content repository for e-learning. J Digit Imaging 19(3):207–215, 2006PubMedCrossRef Hsiao CH, Hsu TC, Chang JN, Yang SJH, Young ST, Chu WC: Developing a medical image content repository for e-learning. J Digit Imaging 19(3):207–215, 2006PubMedCrossRef
21.
go back to reference Hur W, Lee J, Kim CY: Web-based diagnostic imaging service using XML forms. J Digit Imaging 19(4):328–335, 2006PubMedCrossRef Hur W, Lee J, Kim CY: Web-based diagnostic imaging service using XML forms. J Digit Imaging 19(4):328–335, 2006PubMedCrossRef
22.
go back to reference Clark KW, Gierada DS, Moore SM, Maffitt DR, Koppel P, Phillips SR, Prior FW: Creation of a CT Image Library for the Lung Screening Study of the National Lung Screening Trial. J Digit Imaging 20(1):23–31, 2007PubMedCrossRef Clark KW, Gierada DS, Moore SM, Maffitt DR, Koppel P, Phillips SR, Prior FW: Creation of a CT Image Library for the Lung Screening Study of the National Lung Screening Trial. J Digit Imaging 20(1):23–31, 2007PubMedCrossRef
23.
go back to reference Mangasarian OL, Street WN, Wolberg WH: Breast cancer diagnosis and prognosis via linear programming. Oper Res 43(4):570–577, 1995CrossRef Mangasarian OL, Street WN, Wolberg WH: Breast cancer diagnosis and prognosis via linear programming. Oper Res 43(4):570–577, 1995CrossRef
24.
go back to reference Murase K: Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging. Magn Reson Med 51(4):858–62, 2004PubMedCrossRef Murase K: Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging. Magn Reson Med 51(4):858–62, 2004PubMedCrossRef
25.
go back to reference Orton MR, Collins DJ, Walker-Samuel S, d’Arcy JA, Hawkes DJ, Atkinson D, Leach MO: Bayesian estimation of pharmacokinetic parameters for DCE-MRI with a robust treatment of enhancement onset time. Phys Med Biol 52:2393–2408, 2007PubMedCrossRef Orton MR, Collins DJ, Walker-Samuel S, d’Arcy JA, Hawkes DJ, Atkinson D, Leach MO: Bayesian estimation of pharmacokinetic parameters for DCE-MRI with a robust treatment of enhancement onset time. Phys Med Biol 52:2393–2408, 2007PubMedCrossRef
26.
go back to reference Schmid VJ, Whitcher B, Padhani AR, Taylor NJ, Yang GZ: Bayesian methods for pharmacokinetic models in dynamic contrast-enhanced magnetic resonance imaging. IEEE Trans Med Imaging 25(12):1627–36, 2006PubMedCrossRef Schmid VJ, Whitcher B, Padhani AR, Taylor NJ, Yang GZ: Bayesian methods for pharmacokinetic models in dynamic contrast-enhanced magnetic resonance imaging. IEEE Trans Med Imaging 25(12):1627–36, 2006PubMedCrossRef
27.
go back to reference Buonaccorsi GA, Roberts C, Cheung S, Watson Y, O’Connor JP, Davies K, Jackson A, Jayson GC, Parker GJ: Comparison of the performance of tracer kinetic model-driven registration for dynamic contrast enhanced MRI using different models of contrast enhancement. Acad Radiol 13(9):1112–23, 2006PubMedCrossRef Buonaccorsi GA, Roberts C, Cheung S, Watson Y, O’Connor JP, Davies K, Jackson A, Jayson GC, Parker GJ: Comparison of the performance of tracer kinetic model-driven registration for dynamic contrast enhanced MRI using different models of contrast enhancement. Acad Radiol 13(9):1112–23, 2006PubMedCrossRef
Metadata
Title
Implementation of a Semi-automated Post-processing System for Parametric MRI Mapping of Human Breast Cancer
Authors
Robert E. Lee
E. Brian Welch
Jared G. Cobb
Tuhin Sinha
John C. Gore
Thomas E. Yankeelov
Publication date
01-08-2009
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2009
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-008-9123-2

Other articles of this Issue 4/2009

Journal of Digital Imaging 4/2009 Go to the issue