25-06-2022 | Scientific Article

Image quality improvement and motion degradation reduction in shoulder MR imaging: comparison of BLADE and rectilinear techniques at 3-Tesla scanning

Authors: Ajay Kohli, David T. Pilkinton, Yin Xi, Gina Cho, Daniel Moore, Daniel Mohammadi, Avneesh Chhabra

Published in: Skeletal Radiology | Issue 12/2022

Login to get access

Abstract

Objective

MR imaging of joints, particularly shoulder, requires a high degree of spatial resolution to ascertain anatomy and pathology. Unfortunately, motion artifacts can reduce the clinical quality of the examinations. BLADE sequence reduces motion degradation improving overall diagnostic imaging quality. The objective was to compare standard, rectilinear k-space coverage turbo spin echo (TSE), and BLADE sequences.

Material and methods

Over a 4-month period, fifty-seven consecutive patients (22 males, 35 females; mean age: 48.5 years, range: 23–64 years) were scanned using traditional intermediate-weighted spin echo and BLADE sequences. Qualitative evaluation was performed by three musculoskeletal fellowship trained radiologists, each with more than 5 years of experience. Image sequences were evaluated using a Likert scale for each of the following five categories: motion degradation, ghosting/phase misregistration artifacts, star/radial encoding artifacts, fat suppression quality, and overall diagnostic quality. Additionally, image sequences were evaluated for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) using manually drawn regions of interest (ROI) analysis.

Results

Ghosting and phase artifacts were lower within BLADE sequence while streak artifacts were higher (p < 0.001). Image fat suppression, tendon and labral appearances, and the overall SNR and CNR were comparable on both sequences (p > 0.05).

Conclusion

Addition of BLADE reduces motion degradation and improves overall diagnostic imaging quality. Application of BLADE in patient scans suspected of motion artifacts can reduce the frequency of repeat imaging in patients with claustrophobia or those where motion is a concern. By reducing overall imaging time and call backs, it could reduce the cost burden to patients and healthcare system.
Literature
1.
go back to reference Östör AJK, Richards CA, Prevost AT, Speed CA, Hazleman BL. Diagnosis and relation to general health of shoulder disorders presenting to primary care. Rheumatology (Oxford). 2005;44(6):800–5.CrossRef Östör AJK, Richards CA, Prevost AT, Speed CA, Hazleman BL. Diagnosis and relation to general health of shoulder disorders presenting to primary care. Rheumatology (Oxford). 2005;44(6):800–5.CrossRef
2.
go back to reference Iannotti JP, Zlatkin MB, Esterhai JL, Kressel HY, Dalinka MK, Spindler KP. Magnetic resonance imaging of the shoulder. Sensitivity, specificity, and predictive value. Journal of Bone. 1991 Jan;73(1):17–29. Iannotti JP, Zlatkin MB, Esterhai JL, Kressel HY, Dalinka MK, Spindler KP. Magnetic resonance imaging of the shoulder. Sensitivity, specificity, and predictive value. Journal of Bone. 1991 Jan;73(1):17–29.
4.
go back to reference Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42(5):963–9.CrossRef Pipe JG. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med. 1999;42(5):963–9.CrossRef
5.
go back to reference Nyberg E, Sandhu GS, Jesberger J, Blackham KA, Hsu DP, Griswold MA, et al. Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition. AJNR Am J Neuroradiol. 2012 Jan;33(1):77–82. Nyberg E, Sandhu GS, Jesberger J, Blackham KA, Hsu DP, Griswold MA, et al. Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition. AJNR Am J Neuroradiol. 2012 Jan;33(1):77–82.
6.
go back to reference Forbes KP, Pipe JG, Karis JP, Farthing V, Heiserman JE. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. 2003;5. Forbes KP, Pipe JG, Karis JP, Farthing V, Heiserman JE. Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences. 2003;5.
7.
go back to reference Lane BF, Vandermeer FQ, Oz RC, Irwin EW, McMillan AB, Wong-You-Cheong JJ. Comparison of sagittal T2-weighted BLADE and fast spin-echo MRI of the female pelvis for motion artifact and lesion detection. Am J Roentgenol. 2011;197(2):W307–13.CrossRef Lane BF, Vandermeer FQ, Oz RC, Irwin EW, McMillan AB, Wong-You-Cheong JJ. Comparison of sagittal T2-weighted BLADE and fast spin-echo MRI of the female pelvis for motion artifact and lesion detection. Am J Roentgenol. 2011;197(2):W307–13.CrossRef
8.
go back to reference Nagatomo K, Yabuuchi H, Yamasaki Y, Narita H, Kumazawa S, Kojima T, et al. Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging. Eur J Radiol. 2016;85(10):1735–43.CrossRef Nagatomo K, Yabuuchi H, Yamasaki Y, Narita H, Kumazawa S, Kojima T, et al. Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging. Eur J Radiol. 2016;85(10):1735–43.CrossRef
9.
go back to reference Lavdas E, Mavroidis P, Hatzigeorgiou V, Roka V, Arikidis N, Oikonomou G, et al. Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging. Magn Reson Imaging. 2012;30(8):1099–110.CrossRef Lavdas E, Mavroidis P, Hatzigeorgiou V, Roka V, Arikidis N, Oikonomou G, et al. Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging. Magn Reson Imaging. 2012;30(8):1099–110.CrossRef
10.
go back to reference Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging. 2008;28(4):957–62.CrossRef Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K. Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging. 2008;28(4):957–62.CrossRef
11.
go back to reference Ohgiya Y, Suyama J, Seino N, Takaya S, Kawahara M, Saiki M, et al. MRI of the neck at 3 Tesla using the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) sequence compared with T2-weighted fast spin-echo sequence. J Magn Reson Imaging. 2010;32(5):1061–7.CrossRef Ohgiya Y, Suyama J, Seino N, Takaya S, Kawahara M, Saiki M, et al. MRI of the neck at 3 Tesla using the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) sequence compared with T2-weighted fast spin-echo sequence. J Magn Reson Imaging. 2010;32(5):1061–7.CrossRef
13.
go back to reference Westermann R W, Schick C, Graves C M, Duchman K R, & Weinstein S L. What does a shoulder MRI cost the consumer? Clinical Orthopaedics and Related Research®. 2016 475(3), 580–584. Westermann R W, Schick C, Graves C M, Duchman K R, & Weinstein S L. What does a shoulder MRI cost the consumer? Clinical Orthopaedics and Related Research®. 2016  475(3), 580–584.
Metadata
Title
Image quality improvement and motion degradation reduction in shoulder MR imaging: comparison of BLADE and rectilinear techniques at 3-Tesla scanning
Authors
Ajay Kohli
David T. Pilkinton
Yin Xi
Gina Cho
Daniel Moore
Daniel Mohammadi
Avneesh Chhabra
Publication date
25-06-2022
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 12/2022
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-022-04085-7

Other articles of this Issue 12/2022

Skeletal Radiology 12/2022 Go to the issue

Test Yourself: Question

Left wrist pain in a teenager