Abstract

Background

All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease.

Methods

Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups.

Results

There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197).

Conclusions

The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging.
Literature
1.
go back to reference Khatri S, Varma SK, Khatri P, Kumar RS. 64-slice multidetector-row computed tomographic angiography for evaluating congenital heart disease. Pediatr Cardiol. 2008;29:755–62.CrossRefPubMed Khatri S, Varma SK, Khatri P, Kumar RS. 64-slice multidetector-row computed tomographic angiography for evaluating congenital heart disease. Pediatr Cardiol. 2008;29:755–62.CrossRefPubMed
2.
go back to reference Schroeder S, Achenbach S, Bengel F, Burgstahler C, Cademartiri F, de Feyter P, George R, Kaufmann P, Kopp AF, Knuuti J, Ropers D, Schuijf J, Tops LF, Bax JJ; Working Group Nuclear Cardiology and Cardiac CT; European Society of Cardiology; European Council of Nuclear Cardiology. Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology. Eur Heart J. 2008;29:531–56. Schroeder S, Achenbach S, Bengel F, Burgstahler C, Cademartiri F, de Feyter P, George R, Kaufmann P, Kopp AF, Knuuti J, Ropers D, Schuijf J, Tops LF, Bax JJ; Working Group Nuclear Cardiology and Cardiac CT; European Society of Cardiology; European Council of Nuclear Cardiology. Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology. Eur Heart J. 2008;29:531–56.
3.
go back to reference Herzog C, Mulvihill DM, Nguyen SA, Savino G, Schmidt B, Costello P, Vogl TJ, Schoepf UJ. Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. AJR Am J Roentgenol. 2008;190:1232–40.CrossRefPubMed Herzog C, Mulvihill DM, Nguyen SA, Savino G, Schmidt B, Costello P, Vogl TJ, Schoepf UJ. Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation. AJR Am J Roentgenol. 2008;190:1232–40.CrossRefPubMed
4.
go back to reference Mori Y, Takahashi K, Nakanishi T. Complications of cardiac catheterization in adults and children with congenital heart disease in the current era. Heart Vessels. 2013;28:352–59. Mori Y, Takahashi K, Nakanishi T. Complications of cardiac catheterization in adults and children with congenital heart disease in the current era. Heart Vessels. 2013;28:352–59.
5.
go back to reference Paul JF, Rohnean A, Sigal-Cinqualbre A. Multidetector CT for congenital heart patients: what a paediatric radiologist should know. Pediatr Radiol. 2010;40:869–75.CrossRefPubMed Paul JF, Rohnean A, Sigal-Cinqualbre A. Multidetector CT for congenital heart patients: what a paediatric radiologist should know. Pediatr Radiol. 2010;40:869–75.CrossRefPubMed
6.
go back to reference Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol. 2007;37:818–25.CrossRefPubMed Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol. 2007;37:818–25.CrossRefPubMed
7.
go back to reference Goo HW, Suh DS. Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation. Pediatr Radiol. 2006;36:344–51.CrossRefPubMed Goo HW, Suh DS. Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation. Pediatr Radiol. 2006;36:344–51.CrossRefPubMed
8.
go back to reference Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol. 2005;35:792–8.CrossRefPubMed Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol. 2005;35:792–8.CrossRefPubMed
9.
go back to reference Shiraishi I, Kajiyama Y, Yamagishi M, Hamaoka K, Yagihara T. The applications of non-ECG-gated MSCT angiography in children with congenital heart disease. Int J Cardiol. 2012;156:309–14.CrossRefPubMed Shiraishi I, Kajiyama Y, Yamagishi M, Hamaoka K, Yagihara T. The applications of non-ECG-gated MSCT angiography in children with congenital heart disease. Int J Cardiol. 2012;156:309–14.CrossRefPubMed
10.
go back to reference Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys. 2006;33:4236–48.CrossRefPubMed Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys. 2006;33:4236–48.CrossRefPubMed
11.
go back to reference Gopal A, Mao SS, Karlsberg D, Young E, Waggoner J, Ahmadi N, Pal RS, Leal J, Karlsberg RP, Budoff MJ. Radiation reduction with prospective ECG-triggering acquisition using 64-multidetector Computed Tomographic angiography. Int J Cardiovasc Imaging. 2009;25:405–16.CrossRefPubMed Gopal A, Mao SS, Karlsberg D, Young E, Waggoner J, Ahmadi N, Pal RS, Leal J, Karlsberg RP, Budoff MJ. Radiation reduction with prospective ECG-triggering acquisition using 64-multidetector Computed Tomographic angiography. Int J Cardiovasc Imaging. 2009;25:405–16.CrossRefPubMed
12.
go back to reference Alkadhi H. The revival of step-and-shoot computed tomography coronary angiography: benefits and open questions. J Cardiovasc Comput Tomogr. 2008;2:91–2.CrossRefPubMed Alkadhi H. The revival of step-and-shoot computed tomography coronary angiography: benefits and open questions. J Cardiovasc Comput Tomogr. 2008;2:91–2.CrossRefPubMed
13.
go back to reference Scheffel H, Alkadhi H, Leschka S, Plass A, Desbiolles L, Guber I, Krauss T, Gruenenfelder J, Genoni M, Luescher TF, Marincek B, Stolzmann P. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart. 2008;94:1132–7.CrossRefPubMed Scheffel H, Alkadhi H, Leschka S, Plass A, Desbiolles L, Guber I, Krauss T, Gruenenfelder J, Genoni M, Luescher TF, Marincek B, Stolzmann P. Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart. 2008;94:1132–7.CrossRefPubMed
14.
go back to reference Alkadhi H, Stolzmann P, Scheffel H, Desbiolles L, Baumüller S, Plass A, Genoni M, Marincek B, Leschka S. Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters. Eur J Radiol. 2008;68:385–91.CrossRefPubMed Alkadhi H, Stolzmann P, Scheffel H, Desbiolles L, Baumüller S, Plass A, Genoni M, Marincek B, Leschka S. Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters. Eur J Radiol. 2008;68:385–91.CrossRefPubMed
15.
go back to reference Huang MP, Liang CH, Zhao ZJ, Liu H, Li JL, Zhang JE, Cui YH, Yang L, Liu QS, Ivanc TB, Vembar M. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease. Pediatr Radiol. 2011;41:858–66.CrossRefPubMed Huang MP, Liang CH, Zhao ZJ, Liu H, Li JL, Zhang JE, Cui YH, Yang L, Liu QS, Ivanc TB, Vembar M. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease. Pediatr Radiol. 2011;41:858–66.CrossRefPubMed
16.
go back to reference Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF. Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol. 2009;39:668–76.CrossRefPubMed Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF. Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol. 2009;39:668–76.CrossRefPubMed
17.
go back to reference Jin KN, Park EA, Shin CI, Lee W, Chung JW, Park JH. Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Cardiovasc Imaging. 2010;26 Suppl 1:63–73.CrossRefPubMed Jin KN, Park EA, Shin CI, Lee W, Chung JW, Park JH. Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose. Int J Cardiovasc Imaging. 2010;26 Suppl 1:63–73.CrossRefPubMed
18.
go back to reference Fuchs TA, Stehli J, Bull S, Dougoud S, Clerc OF, Herzog BA, Buechel RR, Gaemperli O, Kaufmann PA. Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination. Eur Heart J. 2014;35:1131–6.CrossRefPubMedPubMedCentral Fuchs TA, Stehli J, Bull S, Dougoud S, Clerc OF, Herzog BA, Buechel RR, Gaemperli O, Kaufmann PA. Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination. Eur Heart J. 2014;35:1131–6.CrossRefPubMedPubMedCentral
19.
go back to reference Hollingsworth CL, Yoshizumi TT, Frush DP, Chan FP, Toncheva G, Nguyen G, Lowry CR, Hurwitz LM. Pediatric cardiac-gated CT angiography: assessment of radiation dose. AJR Am J Roentgenol. 2007;189:12–8.CrossRefPubMed Hollingsworth CL, Yoshizumi TT, Frush DP, Chan FP, Toncheva G, Nguyen G, Lowry CR, Hurwitz LM. Pediatric cardiac-gated CT angiography: assessment of radiation dose. AJR Am J Roentgenol. 2007;189:12–8.CrossRefPubMed
20.
go back to reference Milkovic D, Garaj-Vrhovac V, Ranogajec-Komor M, Miljanic S, Gajski G, Knezevic Z, Beck N. Primary DNA damage assessed with the comet assay and comparison to the absorbed dose of diagnostic X-rays in children. Int J Toxicol. 2009;28:405–16.CrossRefPubMed Milkovic D, Garaj-Vrhovac V, Ranogajec-Komor M, Miljanic S, Gajski G, Knezevic Z, Beck N. Primary DNA damage assessed with the comet assay and comparison to the absorbed dose of diagnostic X-rays in children. Int J Toxicol. 2009;28:405–16.CrossRefPubMed
21.
go back to reference Ketelsen D, Thomas C, Werner M, Luetkhoff MH, Buchgeister M, Tsiflikas I, Reimann A, Burgstahler C, Brodoefel H, Kopp AF, Claussen CD, Heuschmid M. Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography. Eur J Radiol. 2010;73:274–9.CrossRefPubMed Ketelsen D, Thomas C, Werner M, Luetkhoff MH, Buchgeister M, Tsiflikas I, Reimann A, Burgstahler C, Brodoefel H, Kopp AF, Claussen CD, Heuschmid M. Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography. Eur J Radiol. 2010;73:274–9.CrossRefPubMed
22.
go back to reference Klass O, Jeltsch M, Feuerlein S, Brunner H, Nagel HD, Walker MJ, Brambs HJ, Hoffmann MH. Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol. 2009;19:829–36.CrossRefPubMed Klass O, Jeltsch M, Feuerlein S, Brunner H, Nagel HD, Walker MJ, Brambs HJ, Hoffmann MH. Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol. 2009;19:829–36.CrossRefPubMed
23.
go back to reference Earls JP, Berman EL, Urban BA, Curry CA, Lane JL, Jennings RS, McCulloch CC, Hsieh J, Londt JH. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and decreased radiation dose. Radiology. 2008;246:742–53.CrossRefPubMed Earls JP, Berman EL, Urban BA, Curry CA, Lane JL, Jennings RS, McCulloch CC, Hsieh J, Londt JH. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and decreased radiation dose. Radiology. 2008;246:742–53.CrossRefPubMed
24.
go back to reference Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Schömig A, Achenbach S. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009;301:500–7.CrossRefPubMed Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Schömig A, Achenbach S. Estimated radiation dose associated with cardiac CT angiography. JAMA. 2009;301:500–7.CrossRefPubMed
25.
go back to reference Schoenhagen P. Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J. 2008;29:153–4.CrossRefPubMed Schoenhagen P. Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J. 2008;29:153–4.CrossRefPubMed
26.
go back to reference Matt D, Scheffel H, Leschka S, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H. Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol. 2007;189:567–73.CrossRefPubMed Matt D, Scheffel H, Leschka S, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H. Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol. 2007;189:567–73.CrossRefPubMed
27.
go back to reference Leschka S, Wildermuth S, Boehm T, Desbiolles L, Husmann L, Plass A, Koepfli P, Schepis T, Marincek B, Kaufmann PA, Alkadhi H. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology. 2006;241:378–85.CrossRefPubMed Leschka S, Wildermuth S, Boehm T, Desbiolles L, Husmann L, Plass A, Koepfli P, Schepis T, Marincek B, Kaufmann PA, Alkadhi H. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology. 2006;241:378–85.CrossRefPubMed
28.
go back to reference Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A, Brüning R, Reiser MF. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology. 2001;220:712–7.CrossRefPubMed Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A, Brüning R, Reiser MF. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology. 2001;220:712–7.CrossRefPubMed
29.
go back to reference Koifman B, Egdell R, Somerville J. Prevalence of asymptomatic coronary arterial abnormalities detected by angiography in grown-up patients with congenital heart disease. Cardiol Young. 2001;11:614–8.CrossRefPubMed Koifman B, Egdell R, Somerville J. Prevalence of asymptomatic coronary arterial abnormalities detected by angiography in grown-up patients with congenital heart disease. Cardiol Young. 2001;11:614–8.CrossRefPubMed
30.
go back to reference Chen SJ, Lin MT, Lee WJ, Liu KL, Wang JK, Chang CI, Li YW, Chiu IS. Coronary artery anatomy in children with congenital heart disease by computed tomography. Int J Cardiol. 2007;120:363–70.CrossRefPubMed Chen SJ, Lin MT, Lee WJ, Liu KL, Wang JK, Chang CI, Li YW, Chiu IS. Coronary artery anatomy in children with congenital heart disease by computed tomography. Int J Cardiol. 2007;120:363–70.CrossRefPubMed
Metadata
Title
Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease
Authors
Ying Liu
Jian Li
Hongliang Zhao
Yan Jia
Jing Ren
Jian Xu
Yuewen Hao
Minwen Zheng
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2016
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-016-0460-9

Other articles of this Issue 1/2016

Journal of Cardiothoracic Surgery 1/2016 Go to the issue