Abstract

Background

The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses.

Methods

This prospective study investigated 101 primary total hip arthroplasty (THA) cases in 96 patients treated at a single institution. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) and pain and satisfication on a visual analogue scale (VAS) were assessed at a mean follow-up of 79.0 months. Migration and wear were assessed using Einzel-Bild-Roentgen-Analyse (EBRA) software. Radiological acetabular bone alterations and complications were documented.

Results

At mid-term follow-up (mean 79.0 months, range: 51.8–101.7), 81 cases with complete clinical and radiological data were analyzed. Utilisable EBRA measurements were obtained for 42 hips. The mean HHS was 91.1 (range 38.0–100.0), VAS satisfaction was 9.6 (range 6.0–10.0), VAS rest pain was 0.2 (range 0.0–4.0), and VAS load pain was 0.6 (range 0.0–9.0). Mean migration was 0.86 mm (range: 0.0–2.56) at 24 months and 1.34 mm (range: 0.09–3.14) at 5 years, and the mean annual migration rate was 0.22 (range: − 0.24–1.34). The mean total wear was 0.4 mm (range: 0.03–1.0), corresponding to a mean annual wear rate of 0.06 mm per year (range: 0.0–0.17). Radiographic analysis did not reveal any cases of osteolysis, and no revision surgeries had to be performed.

Conclusions

After using vitamin-E blended HXLPE in cementless isoelastic monoblock cups, there were no obvious signs of osteolysis or aseptic loosening occurred. No patients required revision surgery after mid-term follow-up. Cup migration and wear values were well below the benchmarks considered predictive for potential future failure.

Trial registration

The trial registration number on ClinicalTrials.​gov: NCT04322916 (retrospectively registered at 26.03.2020).
Appendix
Available only for authorised users
Literature
1.
go back to reference Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007;370:1508–19.CrossRef Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007;370:1508–19.CrossRef
2.
go back to reference Rochcongar G, Buia G, Bourroux E, Dunet J, Chapus V, Hulet C. Creep and Wear in vitamin E-infused highly cross-linked polyethylene cups for Total hip Arthroplasty: a prospective randomized controlled trial. J Bone Joint Surg Am. 2018;100(2):107–14.CrossRef Rochcongar G, Buia G, Bourroux E, Dunet J, Chapus V, Hulet C. Creep and Wear in vitamin E-infused highly cross-linked polyethylene cups for Total hip Arthroplasty: a prospective randomized controlled trial. J Bone Joint Surg Am. 2018;100(2):107–14.CrossRef
3.
go back to reference Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, et al. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Joint Surg Am. 2008;90:299–306.CrossRef Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, et al. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Joint Surg Am. 2008;90:299–306.CrossRef
4.
go back to reference Ihle M, Mai S, Pfluger D, Siebert W. The results of the titanium-coated RM acetabular component at 20 years: a term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br). 2008;90(1):1284–90.CrossRef Ihle M, Mai S, Pfluger D, Siebert W. The results of the titanium-coated RM acetabular component at 20 years: a term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br). 2008;90(1):1284–90.CrossRef
5.
go back to reference Wyatt M, Weidner J, Pfluger D, Beck M. The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups. Hip Int. 2017;27:368–72.CrossRef Wyatt M, Weidner J, Pfluger D, Beck M. The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups. Hip Int. 2017;27:368–72.CrossRef
7.
go back to reference Lafon L, Moubarak H, Druon J, Rosset P. Cementless RM Pressfit® cup. A clinical and radiological study of 91 cases with at least four years follow-up. Orthop Traumatol Surg Res. 2014;100:S225–9.CrossRef Lafon L, Moubarak H, Druon J, Rosset P. Cementless RM Pressfit® cup. A clinical and radiological study of 91 cases with at least four years follow-up. Orthop Traumatol Surg Res. 2014;100:S225–9.CrossRef
8.
go back to reference Pakvis D, Biemond L, van Hellemondt G, Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop. 2011;35:1445–51.CrossRef Pakvis D, Biemond L, van Hellemondt G, Spruit M. A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up. Int Orthop. 2011;35:1445–51.CrossRef
10.
go back to reference Erivan R, Eymond G, Villatte G, Mulliez A, Myriam G, Descamps S, et al. RM Pressfit® cup: good preliminary results at 5 to 8 years follow-up for 189 patients. Hip Int. 2016;26:386–91.CrossRef Erivan R, Eymond G, Villatte G, Mulliez A, Myriam G, Descamps S, et al. RM Pressfit® cup: good preliminary results at 5 to 8 years follow-up for 189 patients. Hip Int. 2016;26:386–91.CrossRef
11.
go back to reference Beck M, Delfosse D, Lerf R, Becker R, French G. Oxidation prevention with vitamin E in a HXLPE isoelastic monoblock pressfit cup: preliminary results. In: Knahr K, editor. Total hip arthroplasty. Heidelberg: Springer; 2012. p. 21–31.CrossRef Beck M, Delfosse D, Lerf R, Becker R, French G. Oxidation prevention with vitamin E in a HXLPE isoelastic monoblock pressfit cup: preliminary results. In: Knahr K, editor. Total hip arthroplasty. Heidelberg: Springer; 2012. p. 21–31.CrossRef
12.
go back to reference Oral E, Muratoglu OK. Vitamin E diffused, highly crosslinked UHMWPE: a review. Int Orthop. 2011;35:215–23.CrossRef Oral E, Muratoglu OK. Vitamin E diffused, highly crosslinked UHMWPE: a review. Int Orthop. 2011;35:215–23.CrossRef
13.
go back to reference Oral E, Wannomae KK, Hawkins N, Harris WH, Muratoglu OK. α-Tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials. 2004;25:5515–22.CrossRef Oral E, Wannomae KK, Hawkins N, Harris WH, Muratoglu OK. α-Tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials. 2004;25:5515–22.CrossRef
14.
go back to reference Scemama C, Anract P, Dumaine V, Babinet A, Courpied JP, Hamadouche M. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial. Int Orthop. 2017;41:1113–8.CrossRef Scemama C, Anract P, Dumaine V, Babinet A, Courpied JP, Hamadouche M. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial. Int Orthop. 2017;41:1113–8.CrossRef
15.
go back to reference Lerf R, Zurbrügg D, Delfosse D. Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials. 2010;31:3643–8.CrossRef Lerf R, Zurbrügg D, Delfosse D. Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials. 2010;31:3643–8.CrossRef
16.
go back to reference Bracco P, Oral E. Vitamin E-stabilized UHMWPE for total joint implants: a review. Clin Orthop Relat Res. 2011;469:2286–93.CrossRef Bracco P, Oral E. Vitamin E-stabilized UHMWPE for total joint implants: a review. Clin Orthop Relat Res. 2011;469:2286–93.CrossRef
17.
go back to reference Halma J, Senaris J, Delfosse D, Lerf R, Oberbach T, van Gaalen S, et al. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations. J Biomed Mater Res B Appl Biomater. 2014;102:1627–38.CrossRef Halma J, Senaris J, Delfosse D, Lerf R, Oberbach T, van Gaalen S, et al. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations. J Biomed Mater Res B Appl Biomater. 2014;102:1627–38.CrossRef
18.
go back to reference Halma J, Eshuis R, Vogely HC, van Gaalen S, de Gast A. An uncemented iso-elastic monoblock acetabular component: preliminary results. J Arthroplast. 2015;30:615–21.CrossRef Halma J, Eshuis R, Vogely HC, van Gaalen S, de Gast A. An uncemented iso-elastic monoblock acetabular component: preliminary results. J Arthroplast. 2015;30:615–21.CrossRef
19.
go back to reference Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplast. 2002;17:649–61.CrossRef Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplast. 2002;17:649–61.CrossRef
20.
go back to reference Krismer M, Bauer R, Tschupik J, Mayrhofer P. EBRA: a method to measure migration of acetabular components. J Biomech. 1995;28:1225–36.CrossRef Krismer M, Bauer R, Tschupik J, Mayrhofer P. EBRA: a method to measure migration of acetabular components. J Biomech. 1995;28:1225–36.CrossRef
21.
go back to reference Ilchmann T, Markovic L, Joshi A, Hardinge K, Murphy J, Wingstrand H. Migration and wear of long-term successful Charnley total hip replacements. J Bone Joint Surg (Br). 1998;80:377–81.CrossRef Ilchmann T, Markovic L, Joshi A, Hardinge K, Murphy J, Wingstrand H. Migration and wear of long-term successful Charnley total hip replacements. J Bone Joint Surg (Br). 1998;80:377–81.CrossRef
22.
go back to reference Kostakos AT, Macheras GA, Frangakis CE, Stafilas KS, Baltas D, Xenakis TA. Migration of the trabecular metal monoblock acetabular cup system. J Arthroplast. 2010;25:35–40.CrossRef Kostakos AT, Macheras GA, Frangakis CE, Stafilas KS, Baltas D, Xenakis TA. Migration of the trabecular metal monoblock acetabular cup system. J Arthroplast. 2010;25:35–40.CrossRef
23.
go back to reference Stocks G, Freeman M, Evans S. Acetabular cup migration. Prediction of aseptic loosening. Bone Joint Surg Br. 1995;77:853–61.CrossRef Stocks G, Freeman M, Evans S. Acetabular cup migration. Prediction of aseptic loosening. Bone Joint Surg Br. 1995;77:853–61.CrossRef
24.
go back to reference Wilkinson J, Gordon A, Stockley I. Experiences with the Plasmacup--early stability, wear, remodelling, and outcome. Int Orthop. 2003;27:S16–9.PubMed Wilkinson J, Gordon A, Stockley I. Experiences with the Plasmacup--early stability, wear, remodelling, and outcome. Int Orthop. 2003;27:S16–9.PubMed
25.
go back to reference Wroblewski B, Siney P, Fleming P. The principle of low frictional torque in the Charnley total hip replacement. Bone Joint Surg Br. 2009;91:855–8.CrossRef Wroblewski B, Siney P, Fleming P. The principle of low frictional torque in the Charnley total hip replacement. Bone Joint Surg Br. 2009;91:855–8.CrossRef
26.
go back to reference Pfeil J, Siebert W, editors. Minimally invasive surgery in Total hip Arthroplasty. Heidelberg: Springer Verlag; 2010. Pfeil J, Siebert W, editors. Minimally invasive surgery in Total hip Arthroplasty. Heidelberg: Springer Verlag; 2010.
27.
go back to reference Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res (1976–2007). 2001;393:137–46.CrossRef Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res (1976–2007). 2001;393:137–46.CrossRef
28.
go back to reference DeLee J, Charnley J. Radiological demarcation of cemented sockets in hip arthroplasty. Clin Orthop Relat Res. 1976;121:20–32. DeLee J, Charnley J. Radiological demarcation of cemented sockets in hip arthroplasty. Clin Orthop Relat Res. 1976;121:20–32.
29.
go back to reference Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am. 1973;55:1629–32.CrossRef Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip replacement: incidence and a method of classification. J Bone Joint Surg Am. 1973;55:1629–32.CrossRef
30.
go back to reference Wilkinson J, Hamer A, Elson R, Stockley I, Eastell R. Precision of EBRA-digital software for monitoring implant migration after total hip arthroplasty. J Arthroplast. 2002;17:910–6.CrossRef Wilkinson J, Hamer A, Elson R, Stockley I, Eastell R. Precision of EBRA-digital software for monitoring implant migration after total hip arthroplasty. J Arthroplast. 2002;17:910–6.CrossRef
31.
go back to reference Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R. Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop. 2005;29:14–7.CrossRef Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R. Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop. 2005;29:14–7.CrossRef
32.
go back to reference Ilchmann T, Mjöberg B, Wingstrand H. Measurement accuracy in acetabular cup wear: three retrospective methods compared with roentgen stereophotogrammetry. J Arthroplast. 1995;10:636–42.CrossRef Ilchmann T, Mjöberg B, Wingstrand H. Measurement accuracy in acetabular cup wear: three retrospective methods compared with roentgen stereophotogrammetry. J Arthroplast. 1995;10:636–42.CrossRef
33.
go back to reference McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–34.PubMed McCalden RW, Naudie DD, Yuan X, Bourne RB. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2323–34.PubMed
34.
go back to reference Krismer M, Stöckl B, Fischer M, Bauer R, Mayrhofer P, Ogon M. Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg (Br). 1996;78:422–6.CrossRef Krismer M, Stöckl B, Fischer M, Bauer R, Mayrhofer P, Ogon M. Early migration predicts late aseptic failure of hip sockets. J Bone Joint Surg (Br). 1996;78:422–6.CrossRef
35.
go back to reference Kurtz S, Dumbleton J, Siskey R, Wang J, Manley M. Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation. J Biomed Mater Res A. 2009;90:549–63.CrossRef Kurtz S, Dumbleton J, Siskey R, Wang J, Manley M. Trace concentrations of vitamin E protect radiation crosslinked UHMWPE from oxidative degradation. J Biomed Mater Res A. 2009;90:549–63.CrossRef
36.
go back to reference van Erp JHJ, Massier JRA, Halma JJ, Snijders TE, de Gast A. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene. Acta Orthop. 2020;91:254–9.CrossRef van Erp JHJ, Massier JRA, Halma JJ, Snijders TE, de Gast A. 2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene. Acta Orthop. 2020;91:254–9.CrossRef
Metadata
Title
The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up
Authors
Yama Afghanyar
Sebastian Joser
Jonas Tecle
Philipp Drees
Jens Dargel
Philipp Rehbein
Karl Philipp Kutzner
Publication date
01-12-2021
Publisher
BioMed Central
Keywords
Hip-TEP
Hip-TEP
Published in
BMC Musculoskeletal Disorders / Issue 1/2021
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-021-03981-8

Other articles of this Issue 1/2021

BMC Musculoskeletal Disorders 1/2021 Go to the issue