Skip to main content
Top
Published in: International Orthopaedics 6/2017

01-06-2017 | Original Paper

Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial

Authors: Caroline Scemama, Philippe Anract, Valérie Dumaine, Antoine Babinet, Jean Pierre Courpied, Moussa Hamadouche

Published in: International Orthopaedics | Issue 6/2017

Login to get access

Abstract

Purpose

Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE).

Methods

One hundred patients were randomised to receive hybrid total hip arthroplasty (THA) using a monoblock cementless acetabular component made either of UHMWPE or vitamin E-blended HXLPE. All other parameters were identical in both groups. Complete follow-up was available for 74 of these patients. Femoral head penetration was measured using a validated computer-assisted method.

Results

The median creep measured 0.111 mm (range, −0.576 – +0.444 mm) in the vitamin E-blended group versus 0.170 mm (range, −0.861 – +0.884 mm) in the UHMWPE group (difference of medians, 0.059; p = 0.046). The median steady state penetration rate was −0.008 mm/year (range, −0.88 – +0.64 mm/year) in the vitamin E-blended group versus 0.133 mm/year (range, −0.84 – +0.85 mm/year) in the UHMWPE group (difference of medians 0.141, p = 0.043).

Conclusions

This study demonstrated that femoral head penetration was lower when using vitamin E-blended HXLPE when compared with UHMWPE, with a steady-state penetration rate far below the osteolysis threshold. Longer-term follow-up is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening.
Literature
1.
go back to reference Warth LC, Callaghan JJ, Liu SS et al (2014) Thirty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old. A concise follow-up of previous reports. J Bone Joint Surg Am 96:1814–1819. doi:10.2106/JBJS.M.01573 CrossRefPubMed Warth LC, Callaghan JJ, Liu SS et al (2014) Thirty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old. A concise follow-up of previous reports. J Bone Joint Surg Am 96:1814–1819. doi:10.​2106/​JBJS.​M.​01573 CrossRefPubMed
2.
go back to reference Berry DJ, Harmsen WS, Cabanela ME, Morrey BF (2002) Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 84-A:171–177CrossRefPubMed Berry DJ, Harmsen WS, Cabanela ME, Morrey BF (2002) Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 84-A:171–177CrossRefPubMed
3.
go back to reference Muratoglu OK, Bragdon CR, O’Connor DO et al (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 16:149–160. doi:10.1054/arth.2001.20540 CrossRefPubMed Muratoglu OK, Bragdon CR, O’Connor DO et al (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty 16:149–160. doi:10.​1054/​arth.​2001.​20540 CrossRefPubMed
5.
go back to reference Glyn-Jones S, Thomas GER, Garfjeld-Roberts P et al (2014) The John Charnley award: highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. Clin Orthop Relat Res 473:432–438. doi:10.1007/s11999-014-3735-2 CrossRefPubMedCentral Glyn-Jones S, Thomas GER, Garfjeld-Roberts P et al (2014) The John Charnley award: highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. Clin Orthop Relat Res 473:432–438. doi:10.​1007/​s11999-014-3735-2 CrossRefPubMedCentral
6.
go back to reference Langlois J, Atlan F, Scemama C et al (2015) A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components. Bone Joint J 97-B:1458–1462. doi:10.1302/0301-620X.97B11.36219 CrossRefPubMed Langlois J, Atlan F, Scemama C et al (2015) A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components. Bone Joint J 97-B:1458–1462. doi:10.​1302/​0301-620X.​97B11.​36219 CrossRefPubMed
7.
go back to reference Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed Dumbleton JH, Manley MT, Edidin AA (2002) A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 17:649–661CrossRefPubMed
11.
go back to reference Rowell SL, Muratoglu OK (2016) Investigation of surgically retrieved, vitamin E-stabilized, crosslinked UHMWPE implants after short-term in vivo service. J Biomed Mater Res B Appl Biomater 104:1132-1140. doi:10.1002/jbm.b.33465 CrossRefPubMed Rowell SL, Muratoglu OK (2016) Investigation of surgically retrieved, vitamin E-stabilized, crosslinked UHMWPE implants after short-term in vivo service. J Biomed Mater Res B Appl Biomater 104:1132-1140. doi:10.​1002/​jbm.​b.​33465 CrossRefPubMed
12.
go back to reference Salemyr M, Muren O, Ahl T et al (2015) Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial. Int Orthop 39:1499–1505. doi:10.1007/s00264-015-2680-3 CrossRefPubMed Salemyr M, Muren O, Ahl T et al (2015) Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial. Int Orthop 39:1499–1505. doi:10.​1007/​s00264-015-2680-3 CrossRefPubMed
13.
go back to reference Shareghi B, Johanson P-E, Kärrholm J (2015) Femoral head penetration of vitamin E-infused highly cross-linked polyethylene liners: a randomized radiostereometric study of seventy hips followed for two years. J Bone Joint Surg Am 97:1366–1371. doi:10.2106/JBJS.N.00595 CrossRefPubMed Shareghi B, Johanson P-E, Kärrholm J (2015) Femoral head penetration of vitamin E-infused highly cross-linked polyethylene liners: a randomized radiostereometric study of seventy hips followed for two years. J Bone Joint Surg Am 97:1366–1371. doi:10.​2106/​JBJS.​N.​00595 CrossRefPubMed
14.
go back to reference Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641CrossRefPubMed Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 79:1635–1641CrossRefPubMed
16.
go back to reference Merle D’Augibné R (1970) Numerical evaluation of hip function. Rev Chir Orthop Reparatrice Appar Mot 56:481–486PubMed Merle D’Augibné R (1970) Numerical evaluation of hip function. Rev Chir Orthop Reparatrice Appar Mot 56:481–486PubMed
17.
go back to reference Yan Y, Chen H, Feng J et al (2016) Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. Int Orthop. doi:10.1007/s00264-016-3217-0 Yan Y, Chen H, Feng J et al (2016) Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. Int Orthop. doi:10.​1007/​s00264-016-3217-0
19.
20.
go back to reference Martell JM, Berkson E, Berger R, Jacobs J (2003) Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 85-A:1111–1117CrossRefPubMed Martell JM, Berkson E, Berger R, Jacobs J (2003) Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am 85-A:1111–1117CrossRefPubMed
21.
go back to reference Ihle M, Mai S, Pfluger D, Siebert W (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br) 90:1284–1290. doi:10.1302/0301-620X.90B10.20274 CrossRef Ihle M, Mai S, Pfluger D, Siebert W (2008) The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement. J Bone Joint Surg (Br) 90:1284–1290. doi:10.​1302/​0301-620X.​90B10.​20274 CrossRef
22.
go back to reference Triclot P, Grosjean G, El Masri F et al (2007) A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg (Br) 89:1439–1445. doi:10.1302/0301-620X.89B11.19543 CrossRef Triclot P, Grosjean G, El Masri F et al (2007) A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg (Br) 89:1439–1445. doi:10.​1302/​0301-620X.​89B11.​19543 CrossRef
23.
go back to reference Digas G, Kärrholm J, Thanner J et al (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16 Digas G, Kärrholm J, Thanner J et al (2004) The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res (429):6–16
24.
Metadata
Title
Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial
Authors
Caroline Scemama
Philippe Anract
Valérie Dumaine
Antoine Babinet
Jean Pierre Courpied
Moussa Hamadouche
Publication date
01-06-2017
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 6/2017
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3320-2

Other articles of this Issue 6/2017

International Orthopaedics 6/2017 Go to the issue