Skip to main content
Top
Published in: Calcified Tissue International 3/2021

01-03-2021 | Original Research

High-Resolution Cone-Beam Computed Tomography is a Fast and Promising Technique to Quantify Bone Microstructure and Mechanics of the Distal Radius

Authors: Karen Mys, Peter Varga, Filip Stockmans, Boyko Gueorguiev, Verena Neumann, Olivier Vanovermeire, Caroline E. Wyers, Joop P. W. van den Bergh, G. Harry van Lenthe

Published in: Calcified Tissue International | Issue 3/2021

Login to get access

Abstract

Obtaining high-resolution scans of bones and joints for clinical applications is challenging. HR-pQCT is considered the best technology to acquire high-resolution images of the peripheral skeleton in vivo, but a breakthrough for widespread clinical applications is still lacking. Recently, we showed on trapezia that CBCT is a promising alternative providing a larger FOV at a shorter scanning time. The goals of this study were to evaluate the accuracy of CBCT in quantifying trabecular bone microstructural and predicted mechanical parameters of the distal radius, the most often investigated skeletal site with HR-pQCT, and to compare it with HR-pQCT. Nineteen radii were scanned with four scanners: (1) HR-pQCT (XtremeCT, Scanco Medical AG, @ (voxel size) 82 μm), (2) HR-pQCT (XtremeCT-II, Scanco, @60.7 μm), (3) CBCT (NewTom 5G, Cefla, @75 μm) reconstructed and segmented using in-house developed software and (4) microCT (VivaCT40, Scanco, @19 μm—gold standard). The following parameters were evaluated: predicted stiffness, strength, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N). The overall accuracy of CBCT with in-house optimized algorithms in quantifying bone microstructural parameters was comparable (R2 = 0.79) to XtremeCT (R2 = 0.76) and slightly worse than XtremeCT-II (R2 = 0.86) which were both processed with the standard manufacturer’s technique. CBCT had higher accuracy for BV/TV and Tb.Th but lower for Tb.Sp and Tb.N compared to XtremeCT. Regarding the mechanical parameters, all scanners had high accuracy (R2 \(\ge\) 0.96). While HR-pQCT is optimized for research, the fast scanning time and good accuracy renders CBCT a promising technique for high-resolution clinical scanning.
Literature
10.
go back to reference Mys K, Varga P, Gueorguiev B et al (2018) A comparative analysis between cone-beam computed tomography and high-resolution peripheral computed tomography for the quantification of bone microstructure in the wrist. J Bone Miner Res 34(5):867–874CrossRef Mys K, Varga P, Gueorguiev B et al (2018) A comparative analysis between cone-beam computed tomography and high-resolution peripheral computed tomography for the quantification of bone microstructure in the wrist. J Bone Miner Res 34(5):867–874CrossRef
15.
go back to reference Flaig C (2012) A highly scalable memory efficient multigrid solver for micro-finite element analyses. ETH Zurich Flaig C (2012) A highly scalable memory efficient multigrid solver for micro-finite element analyses. ETH Zurich
16.
go back to reference Pistoia W, van Rietbergen B, Lochmüller E-M et al (2002) Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. Bone 30:842–848CrossRef Pistoia W, van Rietbergen B, Lochmüller E-M et al (2002) Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. Bone 30:842–848CrossRef
23.
Metadata
Title
High-Resolution Cone-Beam Computed Tomography is a Fast and Promising Technique to Quantify Bone Microstructure and Mechanics of the Distal Radius
Authors
Karen Mys
Peter Varga
Filip Stockmans
Boyko Gueorguiev
Verena Neumann
Olivier Vanovermeire
Caroline E. Wyers
Joop P. W. van den Bergh
G. Harry van Lenthe
Publication date
01-03-2021
Publisher
Springer US
Published in
Calcified Tissue International / Issue 3/2021
Print ISSN: 0171-967X
Electronic ISSN: 1432-0827
DOI
https://doi.org/10.1007/s00223-020-00773-5

Other articles of this Issue 3/2021

Calcified Tissue International 3/2021 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.