Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 7/2015

01-07-2015 | Knee

High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci’s method

Authors: D. W. Elson, T. G. Petheram, M. J. Dawson

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 7/2015

Login to get access

Abstract

Purpose

Pre-operative planning is essential in high tibial osteotomy (HTO). Miniaci’s method employs Mikulicz’s weight-bearing line and is advantageous because the point of mechanical loading is related to the known degenerative condition of the knee. Miniaci’s geometrical method has been modified for an opening wedge and described for use with a digital picture archiving and communications system viewer. Reliability for this method was hypothesised to be equivalent to published reliability for landmark-based commercial software and independent of observer experience.

Methods

Twenty-four patients awaiting HTO had standardised long-leg radiographs. Mikulicz’s weight-bearing line was projected through the lateral compartment of the knee at Fujisawa’s point. The correction angle was generated at the hinge point subtending the current and proposed ankle centres. The opening wedge was plotted to measure an opening distance. Observations were recorded twice by three observers. Agreement was reported as intraclass correlation coefficients with 95 % confidence intervals.

Results

Intra-rater agreement was excellent for the correction angle (0.965–0.985) and opening distance (0.928–0.980). If no set hinge point was used, then the inter-rater reliability was 0.986 for the correction angle and 0.984 for the opening distance. There was no discernible pattern demonstrating improved reliability from the experienced observer.

Conclusions

Reliability is comparable to commercially based landmark software and independent of observer experience. This makes such geometrical pre-operative planning accessible to surgeons who perform HTO with insufficient frequency to justify the investment in commercial software.

Level of evidence

Diagnostic study, Level II.
Literature
1.
go back to reference Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593PubMedCrossRef Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2012) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593PubMedCrossRef
2.
go back to reference Akizuki S, Shibakawa A, Takizawa T, Yamazaki I, Horiuchi H (2008) The long-term outcome of high tibial osteotomy: a 10–20-year follow-up. J Bone Jt Surg Br 90:592–596CrossRef Akizuki S, Shibakawa A, Takizawa T, Yamazaki I, Horiuchi H (2008) The long-term outcome of high tibial osteotomy: a 10–20-year follow-up. J Bone Jt Surg Br 90:592–596CrossRef
3.
go back to reference Boesecke R, Bruckner T, Ende G (2000) Landmark based correlation of medical images. Phys Med Biol 35:121–126CrossRef Boesecke R, Bruckner T, Ende G (2000) Landmark based correlation of medical images. Phys Med Biol 35:121–126CrossRef
4.
go back to reference Brown GA, Amendola A (2000) Radiographic evaluation and preoperative planning for high tibial osteotomies. Oper Tech Sports Med 8:2–14CrossRef Brown GA, Amendola A (2000) Radiographic evaluation and preoperative planning for high tibial osteotomies. Oper Tech Sports Med 8:2–14CrossRef
5.
go back to reference Coventry MB (1985) Upper tibial osteotomy for osteoarthritis. J Bone Jt Surg Am 67:1136–1140 Coventry MB (1985) Upper tibial osteotomy for osteoarthritis. J Bone Jt Surg Am 67:1136–1140
6.
go back to reference Demange MK, Camanho GL, Pécora JR, Gobbi RG, Tirico LEP, da Mota E, Albuquerque RF (2011) Simultaneous anterior cruciate ligament reconstruction and computer-assisted open-wedge high tibial osteotomy: a report of eight cases. Knee 18:387–391PubMedCrossRef Demange MK, Camanho GL, Pécora JR, Gobbi RG, Tirico LEP, da Mota E, Albuquerque RF (2011) Simultaneous anterior cruciate ligament reconstruction and computer-assisted open-wedge high tibial osteotomy: a report of eight cases. Knee 18:387–391PubMedCrossRef
7.
go back to reference Engel GM, Lippert FG (1981) Valgus tibial osteotomy: avoiding the pitfalls. Clin Orthop Rel Res 160:137–143 Engel GM, Lippert FG (1981) Valgus tibial osteotomy: avoiding the pitfalls. Clin Orthop Rel Res 160:137–143
8.
go back to reference Flecher X, Parratte S, Aubaniac J-M, Argenson J-NA (2006) A 12–28-year followup study of closing wedge high tibial osteotomy. Clin Orthop Rel Res 452:91–96CrossRef Flecher X, Parratte S, Aubaniac J-M, Argenson J-NA (2006) A 12–28-year followup study of closing wedge high tibial osteotomy. Clin Orthop Rel Res 452:91–96CrossRef
9.
go back to reference Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
10.
go back to reference Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21:90–95PubMedCrossRef Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21:90–95PubMedCrossRef
11.
go back to reference Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Comput Aided Surg 11:81–86PubMedCrossRef Hankemeier S, Gosling T, Richter M, Hufner T, Hochhausen C, Krettek C (2006) Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method. Comput Aided Surg 11:81–86PubMedCrossRef
12.
go back to reference Harris WR, Kostuik JP (1970) High tibial osteotomy for osteo-arthritis of the knee. J Bone Jt Surg Am 52:330–336 Harris WR, Kostuik JP (1970) High tibial osteotomy for osteo-arthritis of the knee. J Bone Jt Surg Am 52:330–336
13.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity: a 10–13-year follow-up study. J Bone Jt Surg Am 69:332–354 Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity: a 10–13-year follow-up study. J Bone Jt Surg Am 69:332–354
14.
go back to reference Insall J, Shoji H, Mayer V (1974) High tibial osteotomy: a 5-year evaluation. J Bone Jt Surg Am 56:1397–1405 Insall J, Shoji H, Mayer V (1974) High tibial osteotomy: a 5-year evaluation. J Bone Jt Surg Am 56:1397–1405
15.
go back to reference Iorio R, Pagnottelli M, Vadalà A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21:113–119PubMedCrossRef Iorio R, Pagnottelli M, Vadalà A, Giannetti S, Di Sette P, Papandrea P, Conteduca F, Ferretti A (2013) Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques. Knee Surg Sports Traumatol Arthrosc 21:113–119PubMedCrossRef
16.
go back to reference Ivarsson I, Myrnerts R, Gillquist J (1990) High tibial osteotomy for medial osteoarthritis of the knee: A 5–7 and 11 year follow-up. J Bone Jt Surg Br 72:238–244 Ivarsson I, Myrnerts R, Gillquist J (1990) High tibial osteotomy for medial osteoarthritis of the knee: A 5–7 and 11 year follow-up. J Bone Jt Surg Br 72:238–244
17.
go back to reference Jackson JP, Waugh W (1961) Tibial osteotomy for osteoarthritis of the knee. J Bone Jt Surg Br 43-B:746–751 Jackson JP, Waugh W (1961) Tibial osteotomy for osteoarthritis of the knee. J Bone Jt Surg Br 43-B:746–751
18.
go back to reference Kettelkamp DB, Chao EY (1972) A method for quantitative analysis of medial and lateral compression forces at the knee during standing. Clin Orthop Relat Res 83:202–213PubMedCrossRef Kettelkamp DB, Chao EY (1972) A method for quantitative analysis of medial and lateral compression forces at the knee during standing. Clin Orthop Relat Res 83:202–213PubMedCrossRef
19.
go back to reference Koshino T, Morii T, Wada J, Saito H, Ozawa N, Noyori K (1989) High tibial osteotomy with fixation by a blade plate for medial compartment osteoarthritis of the knee. Orthop Clin North Am 20:227–243PubMed Koshino T, Morii T, Wada J, Saito H, Ozawa N, Noyori K (1989) High tibial osteotomy with fixation by a blade plate for medial compartment osteoarthritis of the knee. Orthop Clin North Am 20:227–243PubMed
20.
go back to reference Koshino T, Yoshida T, Ara Y, Saito I, Saito T (2004) Fifteen to twenty-eight years’ follow-up results of high tibial valgus osteotomy for osteoarthritic knee. Knee 11:439–444PubMedCrossRef Koshino T, Yoshida T, Ara Y, Saito I, Saito T (2004) Fifteen to twenty-eight years’ follow-up results of high tibial valgus osteotomy for osteoarthritic knee. Knee 11:439–444PubMedCrossRef
21.
22.
go back to reference Macewen W (1879) Antiseptic osteotomy in genu valgum and anterior tibial curves: with a few remarks on the pathology of knock-knee. Br Med J 2:607–609PubMedCentralPubMedCrossRef Macewen W (1879) Antiseptic osteotomy in genu valgum and anterior tibial curves: with a few remarks on the pathology of knock-knee. Br Med J 2:607–609PubMedCentralPubMedCrossRef
23.
go back to reference McGraw KO, Wong SP (1996) Forming inferences about some intraclass correlation coefficients. Psychol Method 1:30–46CrossRef McGraw KO, Wong SP (1996) Forming inferences about some intraclass correlation coefficients. Psychol Method 1:30–46CrossRef
24.
go back to reference Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy: a new fixation device. Clin Orthop Relat Res 246:250–259PubMed Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy: a new fixation device. Clin Orthop Relat Res 246:250–259PubMed
25.
go back to reference Myrnerts R (1980) Failure of the correction of varus deformity obtained by high tibial osteotomy. Acta Orthop Scand 51:569–573PubMedCrossRef Myrnerts R (1980) Failure of the correction of varus deformity obtained by high tibial osteotomy. Acta Orthop Scand 51:569–573PubMedCrossRef
26.
go back to reference Pape D, Lobenhoffer P, Galla M (2009) Detailed planning algorithm for high tibial osteotomy. In: Lobenhoffer P, Heerwaarden RJ, Staubli AE, Jakob RP (eds) Osteotomies around the knee, 1st edn. Thieme, New York, p 43 Pape D, Lobenhoffer P, Galla M (2009) Detailed planning algorithm for high tibial osteotomy. In: Lobenhoffer P, Heerwaarden RJ, Staubli AE, Jakob RP (eds) Osteotomies around the knee, 1st edn. Thieme, New York, p 43
27.
go back to reference Riddle DL, Jiranek WA, Hull JR (2013) Validity and reliability of radiographic knee osteoarthritis measures by arthroplasty surgeons. Orthopedics 36:e25–e32PubMedCrossRef Riddle DL, Jiranek WA, Hull JR (2013) Validity and reliability of radiographic knee osteoarthritis measures by arthroplasty surgeons. Orthopedics 36:e25–e32PubMedCrossRef
28.
go back to reference Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A (2012) The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36:1767–1772PubMedCentralPubMedCrossRef Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A (2012) The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36:1767–1772PubMedCentralPubMedCrossRef
29.
go back to reference Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy: interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196PubMedCrossRef Schröter S, Ihle C, Mueller J, Lobenhoffer P, Stöckle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy: interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196PubMedCrossRef
30.
go back to reference Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428PubMedCrossRef Shrout PE, Fleiss JL (1979) Intraclass correlations: uses in assessing rater reliability. Psychol Bull 86:420–428PubMedCrossRef
31.
go back to reference Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TDV (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77PubMedCentralPubMedCrossRef Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TDV (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77PubMedCentralPubMedCrossRef
32.
go back to reference Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21:3–22PubMedCrossRef Smith JO, Wilson AJ, Thomas NP (2013) Osteotomy around the knee: evolution, principles and results. Knee Surg Sports Traumatol Arthrosc 21:3–22PubMedCrossRef
33.
go back to reference Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed
34.
go back to reference Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthritis: survival and failure analysis to 22 years. J Bone Jt Surg Am 85-A:469–474 Sprenger TR, Doerzbacher JF (2003) Tibial osteotomy for the treatment of varus gonarthritis: survival and failure analysis to 22 years. J Bone Jt Surg Am 85-A:469–474
35.
go back to reference Wiig O, Terjesen T, Svenningsen S (2002) Inter-observer reliability of radiographic classifications and measurements in the assessment of Perthes’ disease. Acta Orthop Scand 73:523–530PubMedCrossRef Wiig O, Terjesen T, Svenningsen S (2002) Inter-observer reliability of radiographic classifications and measurements in the assessment of Perthes’ disease. Acta Orthop Scand 73:523–530PubMedCrossRef
Metadata
Title
High reliability in digital planning of medial opening wedge high tibial osteotomy, using Miniaci’s method
Authors
D. W. Elson
T. G. Petheram
M. J. Dawson
Publication date
01-07-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 7/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-2920-x

Other articles of this Issue 7/2015

Knee Surgery, Sports Traumatology, Arthroscopy 7/2015 Go to the issue