Skip to main content
Top
Published in: BMC Nephrology 1/2014

Open Access 01-12-2014 | Case report

Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report

Authors: Julio C Chirinos, Javier A Neyra, Jiten Patel, Aylin R Rodan

Published in: BMC Nephrology | Issue 1/2014

Login to get access

Abstract

Background

Ultrasound-guided Central Venous Catheterization (CVC) for temporary vascular access, preferably using the right internal jugular vein, is widely accepted by nephrologists. However CVC is associated with numerous potential complications, including death. We describe the finding of a rare left-sided partial anomalous pulmonary vein connection during central venous catheterization for continuous renal replacement therapy (CRRT).

Case presentation

Ultrasound-guided cannulation of a large bore temporary dual-lumen Quinton-Mahurkar catheter into the left internal jugular vein was performed for CRRT initiation in a 66 year old African-American with sepsis-related oliguric acute kidney injury. The post-procedure chest X-ray suggested inadvertent left carotid artery cannulation. Blood gases obtained from the catheter showed high partial pressure of oxygen (PO2) of 140 mmHg and low partial pressure of carbon dioxide (PCO2) of 22 mmHg, suggestive of arterial cannulation. However, the pressure-transduced wave forms appeared venous and Computed Tomography Angiography located the catheter in the left internal jugular vein, but demonstrated that the tip of the catheter was lying over a left pulmonary vein which was abnormally draining into the left brachiocephalic (innominate) vein rather than into the left atrium.

Conclusion

Although several mechanical complications of dialysis catheters have been described, ours is one of the few cases of malposition into an anomalous pulmonary vein, and highlights a sequential approach to properly identify the catheter location in this uncommon clinical scenario.
Appendix
Available only for authorised users
Literature
1.
go back to reference Choi JI, Cho SG, Yi JH, Han SW, Kim HJ: Unintended cannulation of the subclavian artery in a 65-year-old-female for temporary hemodialysis vascular access: management and prevention. J Korean Med Sci. 2012, 27 (10): 1265-1268. 10.3346/jkms.2012.27.10.1265.CrossRefPubMedPubMedCentral Choi JI, Cho SG, Yi JH, Han SW, Kim HJ: Unintended cannulation of the subclavian artery in a 65-year-old-female for temporary hemodialysis vascular access: management and prevention. J Korean Med Sci. 2012, 27 (10): 1265-1268. 10.3346/jkms.2012.27.10.1265.CrossRefPubMedPubMedCentral
2.
go back to reference Choi YS, Park JY, Kwak YL, Lee JW: Inadvertent arterial insertion of a central venous catheter: delayed recognition with abrupt changes in pressure waveform during surgery -A case report. Korean J Anesthesiol. 2011, 60 (1): 47-51. 10.4097/kjae.2011.60.1.47.CrossRefPubMedPubMedCentral Choi YS, Park JY, Kwak YL, Lee JW: Inadvertent arterial insertion of a central venous catheter: delayed recognition with abrupt changes in pressure waveform during surgery -A case report. Korean J Anesthesiol. 2011, 60 (1): 47-51. 10.4097/kjae.2011.60.1.47.CrossRefPubMedPubMedCentral
3.
go back to reference Schummer W, Schummer C, Rose N, Niesen WD, Sakka SG: Mechanical complications and malpositions of central venous cannulations by experienced operators. A prospective study of 1794 catheterizations in critically ill patients. Intensive Care Med. 2007, 33 (6): 1055-1059. 10.1007/s00134-007-0560-z.CrossRefPubMed Schummer W, Schummer C, Rose N, Niesen WD, Sakka SG: Mechanical complications and malpositions of central venous cannulations by experienced operators. A prospective study of 1794 catheterizations in critically ill patients. Intensive Care Med. 2007, 33 (6): 1055-1059. 10.1007/s00134-007-0560-z.CrossRefPubMed
4.
go back to reference Pikwer A, Acosta S, Kolbel T, Malina M, Sonesson B, Akeson J: Management of inadvertent arterial catheterisation associated with central venous access procedures. Eur J Vasc Endovasc Surg. 2009, 38 (6): 707-714. 10.1016/j.ejvs.2009.08.009.CrossRefPubMed Pikwer A, Acosta S, Kolbel T, Malina M, Sonesson B, Akeson J: Management of inadvertent arterial catheterisation associated with central venous access procedures. Eur J Vasc Endovasc Surg. 2009, 38 (6): 707-714. 10.1016/j.ejvs.2009.08.009.CrossRefPubMed
5.
go back to reference Seldinger SI: Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol. 1953, 39 (5): 368-376. 10.3109/00016925309136722.CrossRefPubMed Seldinger SI: Catheter replacement of the needle in percutaneous arteriography; a new technique. Acta Radiol. 1953, 39 (5): 368-376. 10.3109/00016925309136722.CrossRefPubMed
6.
go back to reference Wadhwa R, Toms J, Nanda A, Abreo K, Cuellar H: Angioplasty and stenting of a jugular-carotid fistula resulting from the inadvertent placement of a hemodialysis catheter: case report and review of literature. Semin Dial. 2012, 25 (4): 460-463. 10.1111/j.1525-139X.2011.01005.x.CrossRefPubMed Wadhwa R, Toms J, Nanda A, Abreo K, Cuellar H: Angioplasty and stenting of a jugular-carotid fistula resulting from the inadvertent placement of a hemodialysis catheter: case report and review of literature. Semin Dial. 2012, 25 (4): 460-463. 10.1111/j.1525-139X.2011.01005.x.CrossRefPubMed
7.
go back to reference Gilbert TB, Seneff MG, Becker RB: Facilitation of internal jugular venous cannulation using an audio-guided Doppler ultrasound vascular access device: results from a prospective, dual-center, randomized, crossover clinical study. Crit Care Med. 1995, 23 (1): 60-65.CrossRefPubMed Gilbert TB, Seneff MG, Becker RB: Facilitation of internal jugular venous cannulation using an audio-guided Doppler ultrasound vascular access device: results from a prospective, dual-center, randomized, crossover clinical study. Crit Care Med. 1995, 23 (1): 60-65.CrossRefPubMed
8.
go back to reference Milling TJ, Rose J, Briggs WM, Birkhahn R, Gaeta TJ, Bove JJ, Melniker LA: Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial. Crit Care Med. 2005, 33 (8): 1764-1769.CrossRefPubMed Milling TJ, Rose J, Briggs WM, Birkhahn R, Gaeta TJ, Bove JJ, Melniker LA: Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial. Crit Care Med. 2005, 33 (8): 1764-1769.CrossRefPubMed
9.
go back to reference Sobrinho G, Salcher J: Partial anomalous pulmonary vein drainage of the left lower lobe: incidental diagnostic after central venous cannulation. Crit Care Med. 2003, 31 (4): 1271-1272.CrossRefPubMed Sobrinho G, Salcher J: Partial anomalous pulmonary vein drainage of the left lower lobe: incidental diagnostic after central venous cannulation. Crit Care Med. 2003, 31 (4): 1271-1272.CrossRefPubMed
10.
go back to reference Jobes DR, Schwartz AJ, Greenhow DE, Stephenson LW, Ellison N: Safer jugular vein cannulation: recognition of arterial puncture and preferential use of the external jugular route. Anesthesiology. 1983, 59 (4): 353-355. 10.1097/00000542-198310000-00017.CrossRefPubMed Jobes DR, Schwartz AJ, Greenhow DE, Stephenson LW, Ellison N: Safer jugular vein cannulation: recognition of arterial puncture and preferential use of the external jugular route. Anesthesiology. 1983, 59 (4): 353-355. 10.1097/00000542-198310000-00017.CrossRefPubMed
11.
go back to reference Aghdami A, Ellis R: High oxygen saturation does not always indicate arterial placement of catheter during internal jugular venous cannulation. Anesthesiology. 1985, 62 (3): 372-373. 10.1097/00000542-198503000-00036.CrossRefPubMed Aghdami A, Ellis R: High oxygen saturation does not always indicate arterial placement of catheter during internal jugular venous cannulation. Anesthesiology. 1985, 62 (3): 372-373. 10.1097/00000542-198503000-00036.CrossRefPubMed
12.
go back to reference Chintu MR, Chinnappa S, Bhandari S: Aberrant positioning of a central venous dialysis catheter to reveal a left-sided partial anomalous pulmonary venous connection. Vasc Health Risk Manag. 2008, 4 (5): 1141-1143.PubMedPubMedCentral Chintu MR, Chinnappa S, Bhandari S: Aberrant positioning of a central venous dialysis catheter to reveal a left-sided partial anomalous pulmonary venous connection. Vasc Health Risk Manag. 2008, 4 (5): 1141-1143.PubMedPubMedCentral
13.
go back to reference Boardman P, Hughes JP: Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol. 1998, 53 (1): 10-16. 10.1016/S0009-9260(98)80027-5.CrossRefPubMed Boardman P, Hughes JP: Radiological evaluation and management of malfunctioning central venous catheters. Clin Radiol. 1998, 53 (1): 10-16. 10.1016/S0009-9260(98)80027-5.CrossRefPubMed
14.
go back to reference Patel RY, Friedman A, Shams JN, Silberzweig JE: Central venous catheter tip malposition. J Med Imag Radiat Oncol. 2010, 54 (1): 35-42. 10.1111/j.1754-9485.2010.02143.x.CrossRef Patel RY, Friedman A, Shams JN, Silberzweig JE: Central venous catheter tip malposition. J Med Imag Radiat Oncol. 2010, 54 (1): 35-42. 10.1111/j.1754-9485.2010.02143.x.CrossRef
15.
go back to reference Gibson F, Bodenham A: Misplaced central venous catheters: applied anatomy and practical management. Br J Anaesth. 2013, 110 (3): 333-346. 10.1093/bja/aes497.CrossRefPubMed Gibson F, Bodenham A: Misplaced central venous catheters: applied anatomy and practical management. Br J Anaesth. 2013, 110 (3): 333-346. 10.1093/bja/aes497.CrossRefPubMed
16.
go back to reference Guilbert MC, Elkouri S, Bracco D, Corriveau MM, Beaudoin N, Dubois MJ, Bruneau L, Blair JF: Arterial trauma during central venous catheter insertion: Case series, review and proposed algorithm. J Vasc Surg. 2008, 48 (4): 918-925. 10.1016/j.jvs.2008.04.046. discussion 925CrossRefPubMed Guilbert MC, Elkouri S, Bracco D, Corriveau MM, Beaudoin N, Dubois MJ, Bruneau L, Blair JF: Arterial trauma during central venous catheter insertion: Case series, review and proposed algorithm. J Vasc Surg. 2008, 48 (4): 918-925. 10.1016/j.jvs.2008.04.046. discussion 925CrossRefPubMed
17.
go back to reference Sasikumar N, Ramanan S, Chidambaram S, Rema KM, Cherian KM: Bilateral anomalous pulmonary venous connection to bilateral superior caval veins. World J Pediatr Congenit Heart Surg. 2014, 5 (1): 124-127. 10.1177/2150135113498784.CrossRefPubMed Sasikumar N, Ramanan S, Chidambaram S, Rema KM, Cherian KM: Bilateral anomalous pulmonary venous connection to bilateral superior caval veins. World J Pediatr Congenit Heart Surg. 2014, 5 (1): 124-127. 10.1177/2150135113498784.CrossRefPubMed
18.
go back to reference ElBardissi AW, Dearani JA, Suri RM, Danielson GK: Left-sided partial anomalous pulmonary venous connections. Ann Thorac Surg. 2008, 85 (3): 1007-1014. 10.1016/j.athoracsur.2007.11.038.CrossRefPubMed ElBardissi AW, Dearani JA, Suri RM, Danielson GK: Left-sided partial anomalous pulmonary venous connections. Ann Thorac Surg. 2008, 85 (3): 1007-1014. 10.1016/j.athoracsur.2007.11.038.CrossRefPubMed
Metadata
Title
Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report
Authors
Julio C Chirinos
Javier A Neyra
Jiten Patel
Aylin R Rodan
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Nephrology / Issue 1/2014
Electronic ISSN: 1471-2369
DOI
https://doi.org/10.1186/1471-2369-15-127

Other articles of this Issue 1/2014

BMC Nephrology 1/2014 Go to the issue
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.