Purpose

To characterize the geometry at the corneo-scleral transition for a normal population and its correlation with other anatomic parameters of the eyeball.

Methods

Transversal epidemiologic study on a sample of 100 individuals (right eye) in different ethnic groups (Africans and Caucasians). All of them were examined with Fourier domain optical coherence tomography, auto-refractometer, topographer, and biometer to obtain the corneo-scleral angle (CSA) and additional clinical parameters. The dataset was analyzed to determine correlations between different anatomical parameters and nasal (CSAn) and temporal CSA (CSAt) values.

Results

The CSAt presents a significant but low correlation with the anterior chamber depth—ACD (r = 0.25; p = 0.024), the white-to-white (W–W) distance (r = 0.27; p = 0.022), and the anterior chamber volume (r = 0.25; p = 0.016). CSAn did not correlate significantly with any clinical variable, with all values being lower than 179° (concave). Ethic groups presented significant differences for pachymetry (Pac) and corneal volume (p = 0.033 and p = 0.014), being greater for Caucasians, and temporal corneo-iridial angle (p = 0.006), being greater for Africans. CSA presented and inverse correlation with age.

Conclusions

The CSAn presents a more concave profile for the normal population, whereas the CSAt presents a planar-convex profile with a great influence of age. In particular, the older the patient, the more convex the CSAt is. This age-related evolution of the CSAt and the concavity on the nasal direction must be considered when prescribing scleral contact lenses or when performing limbal incisions during refractive interventions.
Literature
1.
go back to reference Van der Worp E, Bornman D, Ferreira DL, Faria-Ribeiro M, Garcia-Porta N, González-Meijome JM (2014) Modern scleral contact lenses: a review. Cont Lens Anterior Eye 37:240–250CrossRef Van der Worp E, Bornman D, Ferreira DL, Faria-Ribeiro M, Garcia-Porta N, González-Meijome JM (2014) Modern scleral contact lenses: a review. Cont Lens Anterior Eye 37:240–250CrossRef
2.
go back to reference Meier D (1992) Das cornea-skleral-profil—ein kriterium individueller kontaktlinsenanpassung. Die Kontaktlinse 10:4–11 Meier D (1992) Das cornea-skleral-profil—ein kriterium individueller kontaktlinsenanpassung. Die Kontaktlinse 10:4–11
3.
go back to reference van der Worp E (2010) A Guide to Scleral Lens Fitting [monograph online]. Scleral Lens Education Society. Pacific University Libraries van der Worp E (2010) A Guide to Scleral Lens Fitting [monograph online]. Scleral Lens Education Society. Pacific University Libraries
4.
go back to reference Hall LA, Hunt C, Young G, Wolffsohn J (2013) Factors affecting corneoscleral topography. Invest Ophthalmol Vis Sci 54:3691–3701CrossRef Hall LA, Hunt C, Young G, Wolffsohn J (2013) Factors affecting corneoscleral topography. Invest Ophthalmol Vis Sci 54:3691–3701CrossRef
5.
go back to reference Wang C, Xia X, Tian B, Zhou S (2015) Comparison of Fourier-domain and time-domain optical coherence tomography in the measurement of thinnest corneal thickness in keratoconus. J Ophthalmol 2015:402925PubMedPubMedCentral Wang C, Xia X, Tian B, Zhou S (2015) Comparison of Fourier-domain and time-domain optical coherence tomography in the measurement of thinnest corneal thickness in keratoconus. J Ophthalmol 2015:402925PubMedPubMedCentral
6.
go back to reference Prakash G, Agarwal A, Jacob S, Kumar DA, Agarwal A, Banerjee R (2009) Comparison of Fourier-domain and time-domain optical coherence tomography for assessment of corneal thickness and intersession repeatability. Am J Ophthalmol 148:282–290CrossRef Prakash G, Agarwal A, Jacob S, Kumar DA, Agarwal A, Banerjee R (2009) Comparison of Fourier-domain and time-domain optical coherence tomography for assessment of corneal thickness and intersession repeatability. Am J Ophthalmol 148:282–290CrossRef
7.
go back to reference Wylegała E, Teper S, Nowińska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414CrossRef Wylegała E, Teper S, Nowińska AK, Milka M, Dobrowolski D (2009) Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg 35:1410–1414CrossRef
8.
go back to reference Lilliefors HW (1969) On the Kolmogorov–Smirnov test for the exponential distribution with mean unknown. J Am Stat Assoc 64:387–389CrossRef Lilliefors HW (1969) On the Kolmogorov–Smirnov test for the exponential distribution with mean unknown. J Am Stat Assoc 64:387–389CrossRef
9.
go back to reference Hall LA, Young G, Wolffsohn JS, Riley C (2011) The influence of corneoscleral topography on soft contact lens fit. Invest Ophthalmol Vis Sci 52:6801–6806CrossRef Hall LA, Young G, Wolffsohn JS, Riley C (2011) The influence of corneoscleral topography on soft contact lens fit. Invest Ophthalmol Vis Sci 52:6801–6806CrossRef
10.
go back to reference Consejo A, Llorens-Quintana C, Radhakrishnan H, Iskander DR (2017) Mean shape of the human limbus. J Cataract Refract Surg 43:667–672CrossRef Consejo A, Llorens-Quintana C, Radhakrishnan H, Iskander DR (2017) Mean shape of the human limbus. J Cataract Refract Surg 43:667–672CrossRef
12.
go back to reference Behndig A, Montan P, Lundström M, Zetterström C, Kugelberg M (2014) Gender differences in biometry prediction error and intra-ocular lens power calculation formula. Acta Ophthalmol 92:759–763CrossRef Behndig A, Montan P, Lundström M, Zetterström C, Kugelberg M (2014) Gender differences in biometry prediction error and intra-ocular lens power calculation formula. Acta Ophthalmol 92:759–763CrossRef
13.
go back to reference Tan B, Graham AD, Tsechpenakis G, Lin MC (2014) A novel analytical method using OCT to describe the corneoscleral junction. Optom Vis Sci 91:650–657CrossRef Tan B, Graham AD, Tsechpenakis G, Lin MC (2014) A novel analytical method using OCT to describe the corneoscleral junction. Optom Vis Sci 91:650–657CrossRef
14.
go back to reference Iskander DR, Wachel P, Simpson PN, Consejo A, Jesus DA (2016) Principles of operation, accuracy and precision of an Eye Surface Profiler. Ophthalmic Physiol Opt 36:266–278CrossRef Iskander DR, Wachel P, Simpson PN, Consejo A, Jesus DA (2016) Principles of operation, accuracy and precision of an Eye Surface Profiler. Ophthalmic Physiol Opt 36:266–278CrossRef
15.
go back to reference DeNaeyer G, Sanders DR (2018) sMap3D corneo-scleral topographer repeatability in scleral lens patients. Eye Contact Lens 44(Suppl 1):S259–S264CrossRef DeNaeyer G, Sanders DR (2018) sMap3D corneo-scleral topographer repeatability in scleral lens patients. Eye Contact Lens 44(Suppl 1):S259–S264CrossRef
Metadata
Title
Geometrical characterization of the corneo-scleral transition in normal patients with Fourier domain optical coherence tomography
Authors
Mar Seguí-Crespo
Miguel Ángel Ariza-Gracia
Nelva de Luisa David Sixpene
David P. Piñero
Publication date
01-11-2019
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 11/2019
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-019-01109-5

Other articles of this Issue 11/2019

International Ophthalmology 11/2019 Go to the issue