Abstract

Purpose

To develop a new regression formula based on the Gaussian thick lens formula and to verify the accuracy of the regression formula.

Methods

In this prospective study, 207 eyes of 207 myopic subjects and 133 eyes of 67 postoperative subjects were included. For the 133 postoperative eyes, 127 eyes underwent laser-assisted in situ keratomileusis, and 6 eyes underwent photorefractive keratectomy. Subjective refraction and Pentacam HR were performed preoperatively and postoperatively, and IOLMaster was performed in the postoperative group. SimK, keratometry based on the Gaussian optic formula (KGOF), KCHM obtained using the clinical history method, and the regression formulas KRF1 and KRF2 were calculated.

Results

(1) A statistically significant difference (t = 155.164, P = 0.000) between SimK and KGOF of 1.24 ± 0.12 D was observed, and there was a good correlation between SimK and KGOF (r = 0.996, P = 0.000). The first regression formula (KRF1 = 0.351 + 1.021 × KGOF) was obtained using linear regression. (2) Statistically significant differences (t = 19.114, − 25.184, 4.702, and all P = 0.000) between SimK and KCHM, KGOF and KCHM and KRF1 and KCHM of 0.75 ± 0.45 D, 0.96 ± 0.44 D and 0.18 ± 0.43 D, respectively, were obtained. Good correlations between SimK and KCHM, KGOF and KCHM and KRF1 and KCHM (all r ≧ 0.977, all Ps = 0.000) were also observed. The regression formula (KRF2 = − 1.204 + 1.027 × KRF1) was obtained using linear regression. (3) Six methods were used for the prediction of IOL power in the postoperative group. The highest results were obtained from the Shammas formula (without preoperative data) combining Km (obtained by IOLMaster) followed by the KCHM and KRF2 combining Haigis formula. The third was obtained from the KCHM and KRF2 combining Hoffer Q formula; and the smallest was the Km combining Haigis formula.

Conclusion

The IOL power predicted by KRF2 in eyes after myopic CRS may be accurate.
Literature
1.
go back to reference Feiz V (2010) Intraocular lens power calculation after corneal refractive surgery. Middle East Afr J Ophthalmol 17:63–68PubMedPubMedCentral Feiz V (2010) Intraocular lens power calculation after corneal refractive surgery. Middle East Afr J Ophthalmol 17:63–68PubMedPubMedCentral
2.
go back to reference Kalyani SD, Kim A, Ladas JG (2008) Intraocular lens power calculation after corneal refractive surgery. Curr Opin Ophthalmol 19:357–362CrossRef Kalyani SD, Kim A, Ladas JG (2008) Intraocular lens power calculation after corneal refractive surgery. Curr Opin Ophthalmol 19:357–362CrossRef
3.
go back to reference Hoffer KJ (2009) Intraocular lens power calculation after previous laser refractive surgery. J Cataract Refract Surg 35:759–765CrossRef Hoffer KJ (2009) Intraocular lens power calculation after previous laser refractive surgery. J Cataract Refract Surg 35:759–765CrossRef
4.
go back to reference Patel S, Alio JL, Artola A (2008) Changes in the refractive index of the human corneal stroma during laser in situ keratomileusis. Effects of exposure time and method used to create the flap. J Cataract Refract Surg 34:1077–1082CrossRef Patel S, Alio JL, Artola A (2008) Changes in the refractive index of the human corneal stroma during laser in situ keratomileusis. Effects of exposure time and method used to create the flap. J Cataract Refract Surg 34:1077–1082CrossRef
5.
go back to reference Leyland M (2004) Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation. Eye (Lond) 18:357CrossRef Leyland M (2004) Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation. Eye (Lond) 18:357CrossRef
6.
go back to reference Tang M, Chen A, Li Y, Huang D (2010) Corneal power measurement with Fourier-domain optical coherence tomography. J Cataract Refract Surg 36:2115–2122CrossRef Tang M, Chen A, Li Y, Huang D (2010) Corneal power measurement with Fourier-domain optical coherence tomography. J Cataract Refract Surg 36:2115–2122CrossRef
7.
go back to reference Goss DA, West RW (2002) Introduction to the optics of the Eye. Butterworth-Heinemann, Oxford, pp 113–135 Goss DA, West RW (2002) Introduction to the optics of the Eye. Butterworth-Heinemann, Oxford, pp 113–135
8.
go back to reference Mandell KJ, Jurkunas UV, Pineda R 2nd (2010) Intraocular lens calculations after corneal refractive surgery. Int Ophthalmol Clin 50:181–189CrossRef Mandell KJ, Jurkunas UV, Pineda R 2nd (2010) Intraocular lens calculations after corneal refractive surgery. Int Ophthalmol Clin 50:181–189CrossRef
9.
go back to reference Fam HB, Lim KL (2007) Validity of the keratometric index: large population-based study. J Cataract Refract Surg 33:686–691CrossRef Fam HB, Lim KL (2007) Validity of the keratometric index: large population-based study. J Cataract Refract Surg 33:686–691CrossRef
10.
go back to reference Ho JD et al (2008) Validity of the keratometric index: evaluation by the Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 34:137–145CrossRef Ho JD et al (2008) Validity of the keratometric index: evaluation by the Pentacam rotating Scheimpflug camera. J Cataract Refract Surg 34:137–145CrossRef
11.
go back to reference Crawford AZ, Patel DV, McGhee CN (2013) Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems. Am J Ophthalmol 156:53–60CrossRef Crawford AZ, Patel DV, McGhee CN (2013) Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems. Am J Ophthalmol 156:53–60CrossRef
12.
go back to reference Arce CG et al (2009) Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery. J Refract Surg 25:1061–1074CrossRef Arce CG et al (2009) Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery. J Refract Surg 25:1061–1074CrossRef
13.
go back to reference Jonuscheit S, Doughty MJ (2009) Repeatability of central corneal thickness measures by Orbscan pachymetry for right and left eyes. Eye Contact Lens 35:20–25CrossRef Jonuscheit S, Doughty MJ (2009) Repeatability of central corneal thickness measures by Orbscan pachymetry for right and left eyes. Eye Contact Lens 35:20–25CrossRef
14.
go back to reference Kawana K et al (2005) Central corneal thickness measurements using Orbscan II scanning slit topography, noncontact specular microscopy, and ultrasonic pachymetry in eyes with keratoconus. Cornea 24:967–971CrossRef Kawana K et al (2005) Central corneal thickness measurements using Orbscan II scanning slit topography, noncontact specular microscopy, and ultrasonic pachymetry in eyes with keratoconus. Cornea 24:967–971CrossRef
15.
go back to reference Falavarjani KG et al (2010) Determining corneal power using Pentacam after myopic photorefractive keratectomy. Clin Exp Ophthalmol 38:341–345CrossRef Falavarjani KG et al (2010) Determining corneal power using Pentacam after myopic photorefractive keratectomy. Clin Exp Ophthalmol 38:341–345CrossRef
16.
go back to reference Savini G, Barboni P, Carbonelli M, Hoffer KJ (2009) Agreement between Pentacam and videokeratography in corneal power assessment. J Refract Surg 25:534–538CrossRef Savini G, Barboni P, Carbonelli M, Hoffer KJ (2009) Agreement between Pentacam and videokeratography in corneal power assessment. J Refract Surg 25:534–538CrossRef
17.
go back to reference Kim SW, Kim EK, Cho BJ, Song KY, Kim TI (2009) Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery. J Refract Surg 25:285–289CrossRef Kim SW, Kim EK, Cho BJ, Song KY, Kim TI (2009) Use of the pentacam true net corneal power for intraocular lens calculation in eyes after refractive corneal surgery. J Refract Surg 25:285–289CrossRef
18.
go back to reference Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ (2008) Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery. J Cataract Refract Surg 34:809–813CrossRef Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ (2008) Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery. J Cataract Refract Surg 34:809–813CrossRef
19.
20.
go back to reference Wang X, Dong J, Wu Q (2014) Mean central corneal thickness and corneal power measurements in pigmented and white rabbits using Visante optical coherence tomography and ATLAS corneal topography. Vet Ophthalmol 17:87–90CrossRef Wang X, Dong J, Wu Q (2014) Mean central corneal thickness and corneal power measurements in pigmented and white rabbits using Visante optical coherence tomography and ATLAS corneal topography. Vet Ophthalmol 17:87–90CrossRef
21.
go back to reference Hua Y, Huang J, Pan C, Wang Q (2012) Assessment of total corneal power and intraocular lens power in post-LASIK eyes. Natl Med J China 92:2339–2344 Hua Y, Huang J, Pan C, Wang Q (2012) Assessment of total corneal power and intraocular lens power in post-LASIK eyes. Natl Med J China 92:2339–2344
22.
go back to reference Wang L, Mahmoud AM, Anderson BL, Koch DD, Roberts CJ (2011) Total corneal power estimation: ray tracing method versus gaussian optics formula. Invest Ophthalmol Vis Sci 52:1716–1722CrossRef Wang L, Mahmoud AM, Anderson BL, Koch DD, Roberts CJ (2011) Total corneal power estimation: ray tracing method versus gaussian optics formula. Invest Ophthalmol Vis Sci 52:1716–1722CrossRef
23.
go back to reference Holladay JT, Van Gent S, Ting AC, Portney V, Willis TR (1989) Silicone intraocular lens power vs temperature. Am J Ophthalmol 107:428–429CrossRef Holladay JT, Van Gent S, Ting AC, Portney V, Willis TR (1989) Silicone intraocular lens power vs temperature. Am J Ophthalmol 107:428–429CrossRef
24.
go back to reference Borasio E, Stevens J, Smith GT (2006) Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg 32:2004–2014CrossRef Borasio E, Stevens J, Smith GT (2006) Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg 32:2004–2014CrossRef
25.
go back to reference Shammas HJ et al (2003) Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol 136:426–432CrossRef Shammas HJ et al (2003) Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol 136:426–432CrossRef
26.
go back to reference Jin H, Auffarth GU, Guo H, Zhao P (2012) Corneal power estimation for intraocular lens power calculation after corneal laser refractive surgery in Chinese eyes. J Cataract Refract Surg 38:1749–1757CrossRef Jin H, Auffarth GU, Guo H, Zhao P (2012) Corneal power estimation for intraocular lens power calculation after corneal laser refractive surgery in Chinese eyes. J Cataract Refract Surg 38:1749–1757CrossRef
27.
go back to reference Sharma R, Maharajan P, Kotta S, Maharajan S (2014) Prediction of refractive outcome after cataract surgery using partial coherence interferometry: comparison of SRK/T and Haigis formulae. Int Ophthalmol 34:451–455CrossRef Sharma R, Maharajan P, Kotta S, Maharajan S (2014) Prediction of refractive outcome after cataract surgery using partial coherence interferometry: comparison of SRK/T and Haigis formulae. Int Ophthalmol 34:451–455CrossRef
28.
go back to reference Eom Y, Kang SY, Song JS, Kim HM (2013) Use of corneal power-specific constants to improve the accuracy of the SRK/T formula. Ophthalmology 120:477–481CrossRef Eom Y, Kang SY, Song JS, Kim HM (2013) Use of corneal power-specific constants to improve the accuracy of the SRK/T formula. Ophthalmology 120:477–481CrossRef
29.
go back to reference Langenbucher A et al (2012) Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula. Ophthalmologe 109:468–473CrossRef Langenbucher A et al (2012) Individualization of IOL constants for two hydrophobic intraocular lenses. SRK II, SRK/T, Hoffer-Q, Holladay 1 and Haigis formula. Ophthalmologe 109:468–473CrossRef
30.
go back to reference Holladay JT, Hill WE, Steinmueller A (2009) Corneal power measurements using Scheimpflug imaging in eyes with prior corneal refractive surgery. J Refract Surg 25:862–868CrossRef Holladay JT, Hill WE, Steinmueller A (2009) Corneal power measurements using Scheimpflug imaging in eyes with prior corneal refractive surgery. J Refract Surg 25:862–868CrossRef
31.
go back to reference Holladay JT (2010) Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery. J Cataract Refract Surg 36:182–184CrossRef Holladay JT (2010) Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery. J Cataract Refract Surg 36:182–184CrossRef
32.
go back to reference Xu K, Hao Y, Qi H (2014) Intraocular lens power calculations using a Scheimpflug camera to measure corneal power. Biotech Histochem 89:348–354CrossRef Xu K, Hao Y, Qi H (2014) Intraocular lens power calculations using a Scheimpflug camera to measure corneal power. Biotech Histochem 89:348–354CrossRef
33.
go back to reference McCarthy M, Gavanski GM, Paton KE, Holland SP (2011) Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology 118:940–944CrossRef McCarthy M, Gavanski GM, Paton KE, Holland SP (2011) Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology 118:940–944CrossRef
34.
go back to reference De Bernardo M, Capasso L, Caliendo L, Paolercio F, Rosa N (2014) IOL power calculation after corneal refractive surgery. Biomed Res Int 2014:658350CrossRef De Bernardo M, Capasso L, Caliendo L, Paolercio F, Rosa N (2014) IOL power calculation after corneal refractive surgery. Biomed Res Int 2014:658350CrossRef
35.
go back to reference Masket S, Masket SE (2006) Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32:430–434CrossRef Masket S, Masket SE (2006) Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32:430–434CrossRef
36.
go back to reference Haigis W (2008) Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg 34:1658–1663CrossRef Haigis W (2008) Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg 34:1658–1663CrossRef
37.
go back to reference Peyman A, Peyman M (2009) Intraocular lens power after refractive surgery: Haigis-L formula. J Cataract Refract Surg 35:1650–1651CrossRef Peyman A, Peyman M (2009) Intraocular lens power after refractive surgery: Haigis-L formula. J Cataract Refract Surg 35:1650–1651CrossRef
38.
go back to reference Latkany RA et al (2005) Intraocular lens calculations after refractive surgery. J Cataract Refract Surg 31:562–570CrossRef Latkany RA et al (2005) Intraocular lens calculations after refractive surgery. J Cataract Refract Surg 31:562–570CrossRef
Metadata
Title
Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes
Authors
Yanjun Hua
Chao Pan
Qinmei Wang
Publication date
01-11-2019
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 11/2019
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-019-01089-6

Other articles of this Issue 11/2019

International Ophthalmology 11/2019 Go to the issue