ABSTRACT

Background

Although the implantable cardioverter-defibrillator (ICD) is highly effective therapy for preventing sudden cardiac death, there is considerable uncertainty about its benefits and harms in older patients, especially in the presence of factors, other than old age, that increase the risk of death.

Objective

To develop a prioritized research agenda for the Patient-Centered Outcomes Research Institute as informed by a diverse group of stakeholders on the use and outcomes of the ICD in older patients.

Design

The existing literature was reviewed to identify evidence gaps, which were then refined by engaged stakeholders. Using a forced-ranking prioritization method, the stakeholders ranked evidence gaps by importance. For the highest-ranked evidence gaps, relevant recent studies were identified using PubMed, and relevant ongoing trials were identified using ClinicalTrials.gov.

Participants

Eighteen stakeholders, including clinical experts and researchers in the prevention of sudden cardiac death and ICD therapy, representatives from federal and non-governmental funding agencies, representatives from relevant professional societies, health care decision-makers and policymakers, and representatives from related consumer and patient advocacy groups

Key Results

The top 12 evidence gaps prioritized by stakeholders were related to the safety and effectiveness of ICDs in older patient subgroups not well represented in clinical trials, predictors of SCD, the impact of the ICD on quality of life, the use of shared decision-making, disparities in ICD use, risk stratification strategies, patient preferences, and distribution of modes of death in older patients.

Conclusions

In this paper, we identify evidence gaps of high priority for current and future investigations of ICD therapy. Addressing these gaps will likely resolve many of the uncertainties surrounding the use and outcomes of the ICD in older patients seen in clinical practice.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kong MH, Fonarow GC, Peterson ED, et al. Systematic review of the incidence of sudden cardiac death in the United States. J Am Coll Cardiol. 2011;57(7):794–801.PubMedCentralCrossRefPubMed Kong MH, Fonarow GC, Peterson ED, et al. Systematic review of the incidence of sudden cardiac death in the United States. J Am Coll Cardiol. 2011;57(7):794–801.PubMedCentralCrossRefPubMed
3.
go back to reference Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40.CrossRefPubMed Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40.CrossRefPubMed
4.
go back to reference Buxton AE, Lee KL, Fisher JD, et al. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators.[Erratum appears in N Engl J Med. 2000;342(17):1300]. N Engl J Med. 1999;341(25):1882–90.CrossRefPubMed Buxton AE, Lee KL, Fisher JD, et al. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators.[Erratum appears in N Engl J Med. 2000;342(17):1300]. N Engl J Med. 1999;341(25):1882–90.CrossRefPubMed
5.
go back to reference Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed
6.
go back to reference Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004;350(21):2151–8.CrossRefPubMed Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004;350(21):2151–8.CrossRefPubMed
7.
go back to reference Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.[Erratum appears in N Engl J Med. 2005;352(20):2146]. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.[Erratum appears in N Engl J Med. 2005;352(20):2146]. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed
8.
go back to reference Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.[Erratum appears in Circulation. 2009; 120(5):e34-5]. Circulation. 2008;117(21):e350–408.CrossRefPubMed Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.[Erratum appears in Circulation. 2009; 120(5):e34-5]. Circulation. 2008;117(21):e350–408.CrossRefPubMed
9.
go back to reference Hess PL, Al-Khatib SM, Han JY, et al. Survival benefit of the primary prevention implantable cardioverter-defibrillator among older patients: does age matter? A patient-level meta-analysis of 5 clinical trials. Circ Cardiovasc Qual Outcomes. In press. Hess PL, Al-Khatib SM, Han JY, et al. Survival benefit of the primary prevention implantable cardioverter-defibrillator among older patients: does age matter? A patient-level meta-analysis of 5 clinical trials. Circ Cardiovasc Qual Outcomes. In press.
10.
go back to reference Hess PL, Grau-Sepulveda MV, Hernandez AF, et al. Age differences in the use of implantable cardioverter-defibrillators among older patients hospitalized with heart failure. J Cardiovasc Electrophysiol. 2013;24(6):664–71.PubMedCentralCrossRefPubMed Hess PL, Grau-Sepulveda MV, Hernandez AF, et al. Age differences in the use of implantable cardioverter-defibrillators among older patients hospitalized with heart failure. J Cardiovasc Electrophysiol. 2013;24(6):664–71.PubMedCentralCrossRefPubMed
11.
go back to reference Kremers MS, Hammill SC, Berul CI, et al. The National ICD Registry Report: version 2.1 including leads and pediatrics for years 2010 and 2011. Heart Rhythm. 2013;10(4):e59–65.CrossRefPubMed Kremers MS, Hammill SC, Berul CI, et al. The National ICD Registry Report: version 2.1 including leads and pediatrics for years 2010 and 2011. Heart Rhythm. 2013;10(4):e59–65.CrossRefPubMed
12.
go back to reference Epstein AE, Kay GN, Plumb VJ, et al. Implantable cardioverter-defibrillator prescription in the elderly. Heart Rhythm. 2009;6(8):1136–43.CrossRefPubMed Epstein AE, Kay GN, Plumb VJ, et al. Implantable cardioverter-defibrillator prescription in the elderly. Heart Rhythm. 2009;6(8):1136–43.CrossRefPubMed
13.
go back to reference Chang SM, Carey TS, Kato EU, Guise JM, Sanders GD. Identifying research needs for improving health care. Ann Intern Med. 2012;157(6):439–45.CrossRefPubMed Chang SM, Carey TS, Kato EU, Guise JM, Sanders GD. Identifying research needs for improving health care. Ann Intern Med. 2012;157(6):439–45.CrossRefPubMed
14.
go back to reference Al-Khatib SM, Hellkamp AS, Hernandez AF, et al. Trends in use of implantable cardioverter-defibrillator therapy among patients hospitalized for heart failure: have the previously observed sex and racial disparities changed over time? Circulation. 2012;125(9):1094–101.PubMedCentralCrossRefPubMed Al-Khatib SM, Hellkamp AS, Hernandez AF, et al. Trends in use of implantable cardioverter-defibrillator therapy among patients hospitalized for heart failure: have the previously observed sex and racial disparities changed over time? Circulation. 2012;125(9):1094–101.PubMedCentralCrossRefPubMed
15.
go back to reference Curtis LH, Al-Khatib SM, Shea AM, et al. Sex differences in the use of implantable cardioverter-defibrillators for primary and secondary prevention of sudden cardiac death. JAMA. 2007;298(13):1517–24.CrossRefPubMed Curtis LH, Al-Khatib SM, Shea AM, et al. Sex differences in the use of implantable cardioverter-defibrillators for primary and secondary prevention of sudden cardiac death. JAMA. 2007;298(13):1517–24.CrossRefPubMed
16.
go back to reference Al-Khatib SM, Sanders GD, O’Brien SM, et al. Do physicians’ attitudes toward implantable cardioverter defibrillator therapy vary by patient age, gender, or race? Ann Noninvasive Electrocardiol. 2011;16(1):77–84.CrossRefPubMed Al-Khatib SM, Sanders GD, O’Brien SM, et al. Do physicians’ attitudes toward implantable cardioverter defibrillator therapy vary by patient age, gender, or race? Ann Noninvasive Electrocardiol. 2011;16(1):77–84.CrossRefPubMed
17.
go back to reference Gasparini M, Proclemer A, Klersy C, et al. Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial. JAMA. 2013;309(18):1903–11.CrossRefPubMed Gasparini M, Proclemer A, Klersy C, et al. Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial. JAMA. 2013;309(18):1903–11.CrossRefPubMed
18.
go back to reference Moss AJ, Schuger C, Beck CA, et al. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med. 2012;367(24):2275–83.CrossRefPubMed Moss AJ, Schuger C, Beck CA, et al. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med. 2012;367(24):2275–83.CrossRefPubMed
19.
go back to reference Dewland TA, Pellegrini CN, Wang Y, et al. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. J Am Coll Cardiol. 2011;58(10):1007–13.CrossRefPubMed Dewland TA, Pellegrini CN, Wang Y, et al. Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. J Am Coll Cardiol. 2011;58(10):1007–13.CrossRefPubMed
20.
go back to reference Krahn AD, Lee DS, Birnie D, et al. Predictors of short-term complications after implantable cardioverter-defibrillator replacement: results from the Ontario ICD Database. Circ Arrhythm Electrophysiol. 2011;4(2):136–42.CrossRefPubMed Krahn AD, Lee DS, Birnie D, et al. Predictors of short-term complications after implantable cardioverter-defibrillator replacement: results from the Ontario ICD Database. Circ Arrhythm Electrophysiol. 2011;4(2):136–42.CrossRefPubMed
21.
go back to reference Poole JE, Gleva MJ, Mela T, et al. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation. 2010;122(16):1553–61.CrossRefPubMed Poole JE, Gleva MJ, Mela T, et al. Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation. 2010;122(16):1553–61.CrossRefPubMed
22.
go back to reference Lee DS, Krahn AD, Healey JS, et al. Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. J Am Coll Cardiol. 2010;55(8):774–82.CrossRefPubMed Lee DS, Krahn AD, Healey JS, et al. Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. J Am Coll Cardiol. 2010;55(8):774–82.CrossRefPubMed
23.
go back to reference Almendral J, Arribas F, Wolpert C, et al. Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trial. Europace. 2008;10(5):528–35.CrossRefPubMed Almendral J, Arribas F, Wolpert C, et al. Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trial. Europace. 2008;10(5):528–35.CrossRefPubMed
24.
go back to reference Friedman PA, McClelland RL, Bamlet WR, et al. Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study. Circulation. 2006;113(25):2871–9.CrossRefPubMed Friedman PA, McClelland RL, Bamlet WR, et al. Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis: the detect supraventricular tachycardia study. Circulation. 2006;113(25):2871–9.CrossRefPubMed
25.
go back to reference Ricci RP, Quesada A, Almendral J, et al. Dual-chamber implantable cardioverter defibrillators reduce clinical adverse events related to atrial fibrillation when compared with single-chamber defibrillators: a subanalysis of the DATAS trial. Europace. 2009;11(5):587–93.CrossRefPubMed Ricci RP, Quesada A, Almendral J, et al. Dual-chamber implantable cardioverter defibrillators reduce clinical adverse events related to atrial fibrillation when compared with single-chamber defibrillators: a subanalysis of the DATAS trial. Europace. 2009;11(5):587–93.CrossRefPubMed
26.
go back to reference Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002;288(24):3115–23.CrossRefPubMed Wilkoff BL, Cook JR, Epstein AE, et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA. 2002;288(24):3115–23.CrossRefPubMed
27.
go back to reference Kolb C, Deisenhofer I, Schmieder S, et al. Long-term follow-up of patients supplied with single-chamber or dual-chamber cardioverter defibrillators. Pacing Clin Electrophysiol. 2006;29(9):946–52.CrossRefPubMed Kolb C, Deisenhofer I, Schmieder S, et al. Long-term follow-up of patients supplied with single-chamber or dual-chamber cardioverter defibrillators. Pacing Clin Electrophysiol. 2006;29(9):946–52.CrossRefPubMed
28.
go back to reference Olshansky B, Day JD, Moore S, et al. Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study. Circulation. 2007;115(1):9–16.CrossRefPubMed Olshansky B, Day JD, Moore S, et al. Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) study. Circulation. 2007;115(1):9–16.CrossRefPubMed
29.
go back to reference Wilkoff BL, Kudenchuk PJ, Buxton AE, et al. The DAVID (Dual Chamber and VVI Implantable Defibrillator) II trial. J Am Coll Cardiol. 2009;53(10):872–80.CrossRefPubMed Wilkoff BL, Kudenchuk PJ, Buxton AE, et al. The DAVID (Dual Chamber and VVI Implantable Defibrillator) II trial. J Am Coll Cardiol. 2009;53(10):872–80.CrossRefPubMed
30.
go back to reference Deisenhofer I, Kolb C, Ndrepepa G, et al. Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study. J Cardiovasc Electrophysiol. 2001;12(2):134–42.CrossRefPubMed Deisenhofer I, Kolb C, Ndrepepa G, et al. Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study. J Cardiovasc Electrophysiol. 2001;12(2):134–42.CrossRefPubMed
31.
go back to reference Theuns DA, Klootwijk AP, Goedhart DM, Jordaens LJ. Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms. J Am Coll Cardiol. 2004;44(12):2362–7.CrossRefPubMed Theuns DA, Klootwijk AP, Goedhart DM, Jordaens LJ. Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms. J Am Coll Cardiol. 2004;44(12):2362–7.CrossRefPubMed
32.
go back to reference Bansch D, Steffgen F, Gronefeld G, et al. The 1 + 1 trial: a prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias. Circulation. 2004;110(9):1022–9.CrossRefPubMed Bansch D, Steffgen F, Gronefeld G, et al. The 1 + 1 trial: a prospective trial of a dual- versus a single-chamber implantable defibrillator in patients with slow ventricular tachycardias. Circulation. 2004;110(9):1022–9.CrossRefPubMed
33.
go back to reference Kusumoto FM, Calkins H, Boehmer J, et al. HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. J Am Coll Cardiol. 2014;64(11):1143–77.CrossRefPubMed Kusumoto FM, Calkins H, Boehmer J, et al. HRS/ACC/AHA expert consensus statement on the use of implantable cardioverter-defibrillator therapy in patients who are not included or not well represented in clinical trials. J Am Coll Cardiol. 2014;64(11):1143–77.CrossRefPubMed
34.
go back to reference Weiss R, Knight BP, Gold MR, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation. 2013;128(9):944–53.CrossRefPubMed Weiss R, Knight BP, Gold MR, et al. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation. 2013;128(9):944–53.CrossRefPubMed
35.
go back to reference Bardy GH, Smith WM, Hood MA, et al. An entirely subcutaneous implantable cardioverter-defibrillator. N Engl J Med. 2010;363(1):36–44.CrossRefPubMed Bardy GH, Smith WM, Hood MA, et al. An entirely subcutaneous implantable cardioverter-defibrillator. N Engl J Med. 2010;363(1):36–44.CrossRefPubMed
Metadata
Title
Future Research Prioritization: Implantable Cardioverter-Defibrillator Therapy in Older Patients
Authors
Sana M. Al-Khatib, M.D., M.H.S.
Jennifer M. Gierisch, Ph.D., M.P.H.
Matthew J. Crowley, M.D.
Remy R. Coeytaux, M.D., Ph.D.
Evan R. Myers, M.D., M.P.H.
Amy Kendrick, R.N., M.S.N.
Gillian D. Sanders, Ph.D.
Publication date
01-12-2015
Publisher
Springer US
Published in
Journal of General Internal Medicine / Issue 12/2015
Print ISSN: 0884-8734
Electronic ISSN: 1525-1497
DOI
https://doi.org/10.1007/s11606-015-3411-6

Other articles of this Issue 12/2015

Journal of General Internal Medicine 12/2015 Go to the issue

Letter to the Editor

Health Literacy During Aging

Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.