Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | Fracture Healing | Research article

Comparison of femoral mechanics before and after internal fixation removal and the effect of sclerosis on femoral stress: a finite element analysis

Authors: Yang Liu, Wenjie Song, Haoran Liang, Chaoxin Li, Wenjie Niu, Huifeng Shao, Yuze Wang, Ziquan Yang, Pengcui Li, Xiaogang Wu, Yong He, Xiaochun Wei, Wangping Duan

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Background

Femoral neck fractures are a common traumatic injury. The removal of the internal fixation remains controversial, especially in terms of mechanical stability. Moreover, collapsed necrosis of the femoral head continues to occur after fracture healing. We believe that sclerotic cancellous bone (SCB) formation around the screw is associated with femoral head necrosis. We aimed to compare mechanical features before and after implant removal and determine the effect of SCB formation on stress distribution.

Methods

Cylindrical cancellous bone sections were collected from a relatively normal region and an SCB region of a necrotic femoral head, and their elastic moduli were measured. Four femoral finite element models were developed: a) femoral neck fracture healing with implants, b) fracture healing without implants, c) sclerosis around the screw with implants, and d) sclerosis around the screw without implants.

Results

The maximum von Mises peak stresses of models a and b were 66.643 MPa and 63.76 MPa, respectively, and were concentrated in the upper lateral femur. The main stress was scattered at the lowest screw tail, femoral calcar region, and lateral femur shaft. Moreover, coronal plane strain throughout the screw paths near the femoral head in models a and b was mostly in the range of 1000–3000 με. The maximum stress concentrations in models c and d were located at the lower femoral head and reached 91.199 MPa and 78.019 MPa, respectively.

Conclusions

The stresses in the sclerotic model around the cannulated screws are more concentrated on the femoral head than in the healing model without sclerotic bone. The overall stresses in the healing femoral neck fracture model were essentially unchanged before and after removal of the internal fixation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Maluta T, Toso G, Negri S, Samaila E, Magnan B. Correlation between hip osteoarthritis and proximal femoral fracture site: could it be protective for intracapsular neck fractures? A retrospective study on 320 cases. Osteoporos Int. 2019;30(8):1591–6.CrossRefPubMed Maluta T, Toso G, Negri S, Samaila E, Magnan B. Correlation between hip osteoarthritis and proximal femoral fracture site: could it be protective for intracapsular neck fractures? A retrospective study on 320 cases. Osteoporos Int. 2019;30(8):1591–6.CrossRefPubMed
2.
go back to reference Samsami S, Augat P, Rouhi G. Stability of femoral neck fracture fixation: a finite element analysis. Proc Inst Mech Eng H. 2019;233(9):892–900.CrossRefPubMed Samsami S, Augat P, Rouhi G. Stability of femoral neck fracture fixation: a finite element analysis. Proc Inst Mech Eng H. 2019;233(9):892–900.CrossRefPubMed
3.
go back to reference Slobogean G, Stockton D, Zeng B, Wang D, Ma B, Pollak A. Femoral neck fractures in adults treated with internal fixation: a prospective multicenter Chinese cohort. J Am Acad Orthop Surg. 2017;25(4):297–303.CrossRefPubMed Slobogean G, Stockton D, Zeng B, Wang D, Ma B, Pollak A. Femoral neck fractures in adults treated with internal fixation: a prospective multicenter Chinese cohort. J Am Acad Orthop Surg. 2017;25(4):297–303.CrossRefPubMed
4.
go back to reference Zhou L, Lin J, Huang A, Gan W, Zhai X, Sun K, et al. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study. Clin Biomech (Bristol, Avon). 2020;74:103–10.CrossRef Zhou L, Lin J, Huang A, Gan W, Zhai X, Sun K, et al. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study. Clin Biomech (Bristol, Avon). 2020;74:103–10.CrossRef
5.
go back to reference Weil Y, Qawasmi F, Liebergall M, Mosheiff R, Khoury A. Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures. Arch Orthop Trauma Surg. 2018;138(5):661–7.CrossRefPubMed Weil Y, Qawasmi F, Liebergall M, Mosheiff R, Khoury A. Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures. Arch Orthop Trauma Surg. 2018;138(5):661–7.CrossRefPubMed
6.
go back to reference Hoffmann J, Kellam J, Kumaravel M, Clark K, Routt M, Gary J. Is the cranial and posterior screw of the "inverted triangle" configuration for femoral neck fractures safe? J Orthop Trauma. 2019;33(7):331–4.CrossRefPubMed Hoffmann J, Kellam J, Kumaravel M, Clark K, Routt M, Gary J. Is the cranial and posterior screw of the "inverted triangle" configuration for femoral neck fractures safe? J Orthop Trauma. 2019;33(7):331–4.CrossRefPubMed
7.
8.
go back to reference Mirulla A, Pinelli S, Zaffagnini S, Nigrelli V, Ingrassia T, Paolo S, et al. Numerical simulations on periprosthetic bone remodeling: a systematic review. Comput Methods Prog Biomed. 2021;204:106072.CrossRef Mirulla A, Pinelli S, Zaffagnini S, Nigrelli V, Ingrassia T, Paolo S, et al. Numerical simulations on periprosthetic bone remodeling: a systematic review. Comput Methods Prog Biomed. 2021;204:106072.CrossRef
9.
go back to reference Cresswell E, Goff M, Nguyen T, Lee W, Hernandez C. Spatial relationships between bone formation and mechanical stress within cancellous bone. J Biomech. 2016;49(2):222–8.CrossRefPubMed Cresswell E, Goff M, Nguyen T, Lee W, Hernandez C. Spatial relationships between bone formation and mechanical stress within cancellous bone. J Biomech. 2016;49(2):222–8.CrossRefPubMed
10.
go back to reference Morgan T, Bostrom M, van der Meulen M. Tissue-level remodeling simulations of cancellous bone capture effects of in vivo loading in a rabbit model. J Biomech. 2015;48(5):875–82.CrossRefPubMed Morgan T, Bostrom M, van der Meulen M. Tissue-level remodeling simulations of cancellous bone capture effects of in vivo loading in a rabbit model. J Biomech. 2015;48(5):875–82.CrossRefPubMed
11.
go back to reference Goudie EB, Duckworth AD, White TO. Femoral neck fractures in the Young: Proximal Femur Fractures; 2018.CrossRef Goudie EB, Duckworth AD, White TO. Femoral neck fractures in the Young: Proximal Femur Fractures; 2018.CrossRef
12.
go back to reference Liu Y, Liang H, Zhou X, Song W, Shao H, He Y, et al. Micro-computed tomography analysis of femoral head necrosis after long-term internal fixation for femoral neck fracture. Orthop Surg. 2022;14(6):1186–92.CrossRefPubMedPubMedCentral Liu Y, Liang H, Zhou X, Song W, Shao H, He Y, et al. Micro-computed tomography analysis of femoral head necrosis after long-term internal fixation for femoral neck fracture. Orthop Surg. 2022;14(6):1186–92.CrossRefPubMedPubMedCentral
13.
go back to reference Wang C, Wang X, Xu X, Yuan X, Gou W, Wang A, et al. Bone microstructure and regional distribution of osteoblast and osteoclast activity in the osteonecrotic femoral head. PLoS One. 2014;9(5):e96361.CrossRefPubMedPubMedCentral Wang C, Wang X, Xu X, Yuan X, Gou W, Wang A, et al. Bone microstructure and regional distribution of osteoblast and osteoclast activity in the osteonecrotic femoral head. PLoS One. 2014;9(5):e96361.CrossRefPubMedPubMedCentral
14.
go back to reference Giordano V, Paes R, Alves D, Amaral A, Belangero W, Giordano M, et al. Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study. Eur J Orthop Surg Traumatol. 2018;28(7):1359–67.CrossRefPubMed Giordano V, Paes R, Alves D, Amaral A, Belangero W, Giordano M, et al. Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study. Eur J Orthop Surg Traumatol. 2018;28(7):1359–67.CrossRefPubMed
15.
go back to reference Van Houcke J, Schouten A, Steenackers G, Vandermeulen D, Pattyn C, Audenaert E. Computer-based estimation of the hip joint reaction force and hip flexion angle in three different sitting configurations. Appl Ergon. 2017;63:99–105.CrossRefPubMed Van Houcke J, Schouten A, Steenackers G, Vandermeulen D, Pattyn C, Audenaert E. Computer-based estimation of the hip joint reaction force and hip flexion angle in three different sitting configurations. Appl Ergon. 2017;63:99–105.CrossRefPubMed
16.
go back to reference Freitas A, Toledo Júnior J, Ferreira dos Santos A, Aquino R, Leão V, Péricles de Alcântara W. Biomechanical study of different internal fixations in Pauwels type III femoral neck fracture - a finite elements analysis. J Clin Orthop Trauma. 2021;14:145–50.CrossRefPubMed Freitas A, Toledo Júnior J, Ferreira dos Santos A, Aquino R, Leão V, Péricles de Alcântara W. Biomechanical study of different internal fixations in Pauwels type III femoral neck fracture - a finite elements analysis. J Clin Orthop Trauma. 2021;14:145–50.CrossRefPubMed
17.
go back to reference Li J, Wang M, Li L, Zhang H, Hao M, Li C, et al. Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures. J Orthop Surg Res. 2018;13(1):272.CrossRefPubMedPubMedCentral Li J, Wang M, Li L, Zhang H, Hao M, Li C, et al. Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures. J Orthop Surg Res. 2018;13(1):272.CrossRefPubMedPubMedCentral
18.
go back to reference Chang C, Tsai S, Wu P, Chen C, Chang M, Chen W, et al. Suboptimal outcomes after internal fixation for displaced intracapsular femoral neck fractures in 50- to 60-year-old patients. Hip Int. 2020;30(4):474–80.CrossRefPubMed Chang C, Tsai S, Wu P, Chen C, Chang M, Chen W, et al. Suboptimal outcomes after internal fixation for displaced intracapsular femoral neck fractures in 50- to 60-year-old patients. Hip Int. 2020;30(4):474–80.CrossRefPubMed
19.
go back to reference Sun X, Zeng R, Hu Z, Guo W, Chen S, Wang B, et al. Femoral head necrosis after treatment of famoral neck fractures with compressive hollow screws. Chin J Orthop Trauma. 2012;06:477–9. Sun X, Zeng R, Hu Z, Guo W, Chen S, Wang B, et al. Femoral head necrosis after treatment of famoral neck fractures with compressive hollow screws. Chin J Orthop Trauma. 2012;06:477–9.
20.
go back to reference Chu K, Zhang X, Lu X, Chen X. Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2020;34(9):1091–5.PubMed Chu K, Zhang X, Lu X, Chen X. Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2020;34(9):1091–5.PubMed
21.
go back to reference Wang T, Sun J, Zha G, Jiang T, You Z, Yuan D. Analysis of risk factors for femoral head necrosis after internal fixation in femoral neck fractures. Orthopedics. 2014;37(12):e1117–23.CrossRefPubMed Wang T, Sun J, Zha G, Jiang T, You Z, Yuan D. Analysis of risk factors for femoral head necrosis after internal fixation in femoral neck fractures. Orthopedics. 2014;37(12):e1117–23.CrossRefPubMed
22.
go back to reference Zielinski S, Heetveld M, Bhandari M, Patka P, Van Lieshout E. Implant removal after internal fixation of a femoral neck fracture: effects on physical functioning. J Orthop Trauma. 2015;29(9):e285–92.CrossRefPubMed Zielinski S, Heetveld M, Bhandari M, Patka P, Van Lieshout E. Implant removal after internal fixation of a femoral neck fracture: effects on physical functioning. J Orthop Trauma. 2015;29(9):e285–92.CrossRefPubMed
23.
24.
go back to reference Wang Y, Ma J, Yin T, Han Z, Cui S, Liu Z, et al. Correlation between reduction quality of femoral neck fracture and femoral head necrosis based on biomechanics. Orthop Surg. 2019;11(2):318–24.CrossRefPubMedPubMedCentral Wang Y, Ma J, Yin T, Han Z, Cui S, Liu Z, et al. Correlation between reduction quality of femoral neck fracture and femoral head necrosis based on biomechanics. Orthop Surg. 2019;11(2):318–24.CrossRefPubMedPubMedCentral
25.
go back to reference Ma X, Fu X, Ma J, Dong B, Shen M, Wang Z. Finite element study on spatial distribution and mechanical properties of cancellous bone from femoral head. Yi Yong Sheng Wu Li Xue. 2010;25(06):465–70. Ma X, Fu X, Ma J, Dong B, Shen M, Wang Z. Finite element study on spatial distribution and mechanical properties of cancellous bone from femoral head. Yi Yong Sheng Wu Li Xue. 2010;25(06):465–70.
26.
go back to reference Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharmacother. 2019;112:108658.CrossRefPubMed Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharmacother. 2019;112:108658.CrossRefPubMed
27.
go back to reference Levadnyi I, Awrejcewicz J, Gubaua J, Pereira J. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs. Clin Biomech (Bristol, Avon). 2017;50:122–9.CrossRef Levadnyi I, Awrejcewicz J, Gubaua J, Pereira J. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs. Clin Biomech (Bristol, Avon). 2017;50:122–9.CrossRef
28.
go back to reference Wang H, Ji B, Liu X, Guo X, Huang Y, Hwang K. Analysis of microstructural and mechanical alterations of trabecular bone in a simulated three-dimensional remodeling process. J Biomech. 2021;45(14):2417–25.CrossRef Wang H, Ji B, Liu X, Guo X, Huang Y, Hwang K. Analysis of microstructural and mechanical alterations of trabecular bone in a simulated three-dimensional remodeling process. J Biomech. 2021;45(14):2417–25.CrossRef
29.
go back to reference Zhang X, Liu X, Yan Z, Cai J, Kang F, Shan S, et al. Spatiotemporal characterization of microdamage accumulation in rat ulnae in response to uniaxial compressive fatigue loading. Bone. 2018;108:156–64.CrossRefPubMed Zhang X, Liu X, Yan Z, Cai J, Kang F, Shan S, et al. Spatiotemporal characterization of microdamage accumulation in rat ulnae in response to uniaxial compressive fatigue loading. Bone. 2018;108:156–64.CrossRefPubMed
30.
go back to reference Vestermark M, Bechtold J, Swider P, Søballe K. Mechanical interface conditions affect morphology and cellular activity of sclerotic bone rims forming around experimental loaded implants. J Orthop Res. 2004;22(3):647–52.CrossRefPubMed Vestermark M, Bechtold J, Swider P, Søballe K. Mechanical interface conditions affect morphology and cellular activity of sclerotic bone rims forming around experimental loaded implants. J Orthop Res. 2004;22(3):647–52.CrossRefPubMed
31.
go back to reference Weng PW, Chen CH, Luo CA, Sun JS, Tsuang YH, Cheng CK, et al. The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: a finite element study. Med Eng Phys. 2017;42:48–54.CrossRefPubMed Weng PW, Chen CH, Luo CA, Sun JS, Tsuang YH, Cheng CK, et al. The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: a finite element study. Med Eng Phys. 2017;42:48–54.CrossRefPubMed
32.
go back to reference Webster D, Schulte F, Lambers F, Kuhn G, Müller R. Strain energy density gradients in bone marrow predict osteoblast and osteoclast activity: a finite element study. J Biomech. 2015;48(5):866–74.CrossRefPubMed Webster D, Schulte F, Lambers F, Kuhn G, Müller R. Strain energy density gradients in bone marrow predict osteoblast and osteoclast activity: a finite element study. J Biomech. 2015;48(5):866–74.CrossRefPubMed
Metadata
Title
Comparison of femoral mechanics before and after internal fixation removal and the effect of sclerosis on femoral stress: a finite element analysis
Authors
Yang Liu
Wenjie Song
Haoran Liang
Chaoxin Li
Wenjie Niu
Huifeng Shao
Yuze Wang
Ziquan Yang
Pengcui Li
Xiaogang Wu
Yong He
Xiaochun Wei
Wangping Duan
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-022-05888-4

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue