Skip to main content
Top
Published in: World Journal of Urology 4/2007

Open Access 01-08-2007 | Original Article

Fluid perfused urethral pressure profilometry and Valsalva leak point pressure: a comparative study in a biophysical model of the urethra

Authors: Tim Idzenga, Johan J. M. Pel, Ron van Mastrigt

Published in: World Journal of Urology | Issue 4/2007

Login to get access

Abstract

In patient studies the correlation between maximum urethral closure pressure (MUCP) and Valsalva leak point pressure (LPP) is meagre at best (r = 0.22–0.50). We therefore studied the relation between MUCP and LPP in a flexible and extensible model urethra. We applied differently sized pressure zones and different degrees of resistance to a biophysical model urethra by stepwise inflating three types of blood pressure cuff placed around the model. At each degree of resistance we measured detrusor LPP, an in vitro equivalent of Valsalva LPP. Subsequently, we recorded the Urethral Pressure Profile using a water-perfused 5F end-hole catheter at four withdrawal rates and five perfusion rates and calculated MUCP. We tested the dependence of LPP on pressure zone length and MUCP on perfusion rate, withdrawal rate and pressure zone length using analysis of variance. We tested the correlation between LPP and MUCP using Pearson’s correlation coefficient and Linear Regression. LPP did not significantly depend on the pressure zone length (P = 0.80) and increased linearly with increasing cuff pressure. MUCP also increased with increasing cuff pressure, however, MUCP significantly depended (P < 0.01) on perfusion rate, withdrawal rate and pressure zone length. MUCP increased with increasing perfusion rate, and decreased with increasing withdrawal rate. In our model urethra MUCP only accurately reflected urethral resistance for a very limited number of combinations of perfusion rate and withdrawal rate. LPP reflected urethral resistance independent of the type of pressure zone.
Literature
1.
go back to reference Abrams P, Cardozo L, Fall M et al (2002) The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society. Neurourol Urodyn 21(2):167–178PubMedCrossRef Abrams P, Cardozo L, Fall M et al (2002) The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society. Neurourol Urodyn 21(2):167–178PubMedCrossRef
2.
go back to reference Bruskewitz R, Raz S (1979) Urethral pressure profile using microtip catheter in females. Urology 14(3):303–307PubMedCrossRef Bruskewitz R, Raz S (1979) Urethral pressure profile using microtip catheter in females. Urology 14(3):303–307PubMedCrossRef
3.
go back to reference Griffiths DJ (1985) The pressure within a collapsed tube, with special reference to urethral pressure. Phys Med Biol 30(9):951–963PubMedCrossRef Griffiths DJ (1985) The pressure within a collapsed tube, with special reference to urethral pressure. Phys Med Biol 30(9):951–963PubMedCrossRef
4.
go back to reference Anderson RS, Shepherd AM, Feneley RCL (1983) Microtransducer urethral profile methodology: variations caused by transducer orientation. J Urol 130:727–731PubMed Anderson RS, Shepherd AM, Feneley RCL (1983) Microtransducer urethral profile methodology: variations caused by transducer orientation. J Urol 130:727–731PubMed
5.
go back to reference Schafer W (2001) Some biomechanical aspects of continence function. Scand J Urol Nephrol Suppl 207:44–60; discussion 106–25 Schafer W (2001) Some biomechanical aspects of continence function. Scand J Urol Nephrol Suppl 207:44–60; discussion 106–25
6.
go back to reference Abrams P, Cardozo L, Khoury S et al (eds) (2005) Incontinence: basics and evaluation, chap 11, vol 1. Health Publication Ltd, Plymouth Abrams P, Cardozo L, Khoury S et al (eds) (2005) Incontinence: basics and evaluation, chap 11, vol 1. Health Publication Ltd, Plymouth
7.
go back to reference Weber AM (2001) Is urethral pressure profilometry a useful diagnostic test for stress urinary incontinence? Obstet Gyneacol Surv 56(11):720–735CrossRef Weber AM (2001) Is urethral pressure profilometry a useful diagnostic test for stress urinary incontinence? Obstet Gyneacol Surv 56(11):720–735CrossRef
8.
go back to reference Shawer M, Brown M, Sutherst JR (1983) Comparative examination of female urethral pressure profiles measured by CO2 and H2O infusion techniques. Br J Urol 55(3):326–331PubMed Shawer M, Brown M, Sutherst JR (1983) Comparative examination of female urethral pressure profiles measured by CO2 and H2O infusion techniques. Br J Urol 55(3):326–331PubMed
9.
go back to reference Hanzal E, Berger E, Koelbl H (1991) Reliability of the urethral closure pressure profile during stress in the diagnosis of genuine stress incontinence. Br J Urol 68(4):369–371PubMed Hanzal E, Berger E, Koelbl H (1991) Reliability of the urethral closure pressure profile during stress in the diagnosis of genuine stress incontinence. Br J Urol 68(4):369–371PubMed
10.
go back to reference Meunier P, Mollard P (1978) Urethral pressure profile in children: a comparison between perfused catheters and micro-transducers, and a study of the usefulness of urethral pressure profile measurements in children. J Urol 120(2):207–210PubMed Meunier P, Mollard P (1978) Urethral pressure profile in children: a comparison between perfused catheters and micro-transducers, and a study of the usefulness of urethral pressure profile measurements in children. J Urol 120(2):207–210PubMed
11.
go back to reference De Haas D, Steinberg PJ, Klopper PJ (1989) Qualitative analysis of the four-channel, high-resolution urethral pressure profile of the female dog. J Urol 142(3):855–859PubMed De Haas D, Steinberg PJ, Klopper PJ (1989) Qualitative analysis of the four-channel, high-resolution urethral pressure profile of the female dog. J Urol 142(3):855–859PubMed
12.
go back to reference Carnaille BM, Rigot JM, Bailleul JP et al (1992) Urodynamics in patients with pheochromocytoma: a peri-operative study of 10 cases. World J Surg 16(4):676–679PubMedCrossRef Carnaille BM, Rigot JM, Bailleul JP et al (1992) Urodynamics in patients with pheochromocytoma: a peri-operative study of 10 cases. World J Surg 16(4):676–679PubMedCrossRef
13.
go back to reference McLennan MT, Melick CF, Bent AE (2000) Leak-point pressure: clinical application of values at two different volumes. Int Urogynecol J Pelvic Floor Dysfunct 11(3):136–141PubMedCrossRef McLennan MT, Melick CF, Bent AE (2000) Leak-point pressure: clinical application of values at two different volumes. Int Urogynecol J Pelvic Floor Dysfunct 11(3):136–141PubMedCrossRef
14.
go back to reference Feldner PC Jr, Bezerra LR, de Castro RA et al (2004) Correlation between valsalva leak point pressure and maximal urethral closure pressure in women with stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 15(3):194–197PubMedCrossRef Feldner PC Jr, Bezerra LR, de Castro RA et al (2004) Correlation between valsalva leak point pressure and maximal urethral closure pressure in women with stress urinary incontinence. Int Urogynecol J Pelvic Floor Dysfunct 15(3):194–197PubMedCrossRef
15.
go back to reference Nager CW, Schulz JA, Stanton SL et al (2001) Correlation of urethral closure pressure, leak-point pressure and incontinence severity measures. Int Urogynecol J Pelvic Floor Dysfunct 12(6):395–400PubMedCrossRef Nager CW, Schulz JA, Stanton SL et al (2001) Correlation of urethral closure pressure, leak-point pressure and incontinence severity measures. Int Urogynecol J Pelvic Floor Dysfunct 12(6):395–400PubMedCrossRef
16.
go back to reference Baessler K, Miska K, Draths R et al (2005) Effects of voluntary pelvic floor contraction and relaxation on the urethral closure pressure. Int Urogynecol J 16:187–191CrossRef Baessler K, Miska K, Draths R et al (2005) Effects of voluntary pelvic floor contraction and relaxation on the urethral closure pressure. Int Urogynecol J 16:187–191CrossRef
17.
go back to reference Theofrastous JP, Cundiff GW, Harris RL et al (1996) The effect of vesical volume on Valsalva leak-point pressures in women with genuine stress urinary incontinence. Obstet Gynecol 87(5 Pt 1):711–714PubMedCrossRef Theofrastous JP, Cundiff GW, Harris RL et al (1996) The effect of vesical volume on Valsalva leak-point pressures in women with genuine stress urinary incontinence. Obstet Gynecol 87(5 Pt 1):711–714PubMedCrossRef
18.
go back to reference Faerber GJ, Vashi AR (1998) Variations in Valsalva leak point pressure with increasing vesical volume. J Urol 159(6):1909–1911PubMedCrossRef Faerber GJ, Vashi AR (1998) Variations in Valsalva leak point pressure with increasing vesical volume. J Urol 159(6):1909–1911PubMedCrossRef
19.
go back to reference Decter RM, Harpster L (1992) Pitfalls in determination of leak point pressure. J Urol 148(2 Pt 2):588–591PubMed Decter RM, Harpster L (1992) Pitfalls in determination of leak point pressure. J Urol 148(2 Pt 2):588–591PubMed
20.
go back to reference Nguyen JK, Gunn GC, Bhatia NN (2002) The effect of patient position on leak-point pressure measurements in women with genuine stress incontinence. Int Urogynecol J Pelvic Floor Dysfunct 13(1):9–14PubMedCrossRef Nguyen JK, Gunn GC, Bhatia NN (2002) The effect of patient position on leak-point pressure measurements in women with genuine stress incontinence. Int Urogynecol J Pelvic Floor Dysfunct 13(1):9–14PubMedCrossRef
21.
go back to reference Idzenga T, Pel JJM, Baldewsing RA et al (2005) Perineal noise recording as a non-invasive diagnostic method of urinary bladder outlet obstruction: a study in polyvinyl alcohol and silicone model urethras. Neurourol Urodyn 24(4):381–388PubMedCrossRef Idzenga T, Pel JJM, Baldewsing RA et al (2005) Perineal noise recording as a non-invasive diagnostic method of urinary bladder outlet obstruction: a study in polyvinyl alcohol and silicone model urethras. Neurourol Urodyn 24(4):381–388PubMedCrossRef
22.
go back to reference Idzenga T, Pel JJM, Mastrigt RV (2006) A biophysical model of the male urethra: comparing viscoelastic properties of polyvinyl alcohol urethras to male pig urethras. Neurourol Urodyn 25(5):451–460PubMedCrossRef Idzenga T, Pel JJM, Mastrigt RV (2006) A biophysical model of the male urethra: comparing viscoelastic properties of polyvinyl alcohol urethras to male pig urethras. Neurourol Urodyn 25(5):451–460PubMedCrossRef
23.
go back to reference Brown M, Wickham JEA (1969) The urethral pressure profile. Br J Urol 41(2):211–217PubMed Brown M, Wickham JEA (1969) The urethral pressure profile. Br J Urol 41(2):211–217PubMed
24.
go back to reference Abrams P, Blaivas JG, Stanton SL et al (1988) The standardisation of terminology of lower urinary tract function. Scand J Urol Nephrol Suppl 114:5–19PubMed Abrams P, Blaivas JG, Stanton SL et al (1988) The standardisation of terminology of lower urinary tract function. Scand J Urol Nephrol Suppl 114:5–19PubMed
25.
go back to reference Idzenga T, Pel JJM, Mastrigt RV (2005) Leak point pressure or urethral pressure profilometry? Urodynamic evaluation of continence tested in a model urethra. In: International continence society 35th annual meeting, Montreal, Canada Idzenga T, Pel JJM, Mastrigt RV (2005) Leak point pressure or urethral pressure profilometry? Urodynamic evaluation of continence tested in a model urethra. In: International continence society 35th annual meeting, Montreal, Canada
26.
go back to reference Griffiths DJ (1980) Urodynamics. The mechanics and hydrodynamics of the lower urinary tract. In: Medical physics handbooks, vol 4. Hilger, Bristol Griffiths DJ (1980) Urodynamics. The mechanics and hydrodynamics of the lower urinary tract. In: Medical physics handbooks, vol 4. Hilger, Bristol
27.
go back to reference Asmussen M (1976) Intraurethral pressure recording. A comparison betwen tip-transducer catheters and open-end catheters with constant flow. Scand J Urol Nephrol 10(1):1–6PubMedCrossRef Asmussen M (1976) Intraurethral pressure recording. A comparison betwen tip-transducer catheters and open-end catheters with constant flow. Scand J Urol Nephrol 10(1):1–6PubMedCrossRef
28.
go back to reference Abrams PH, Martin S, Griffiths DJ (1978) The measurement and interpretation of urethral pressures obtained by the method of Brown and Wickham. Br J Urol 50(1):33–38PubMedCrossRef Abrams PH, Martin S, Griffiths DJ (1978) The measurement and interpretation of urethral pressures obtained by the method of Brown and Wickham. Br J Urol 50(1):33–38PubMedCrossRef
29.
go back to reference Martin S, Griffiths DJ (1976) Model of the female urethra: part 1-static measurements of pressure and distensibility. Med Biol Eng 14(5):512–518PubMedCrossRef Martin S, Griffiths DJ (1976) Model of the female urethra: part 1-static measurements of pressure and distensibility. Med Biol Eng 14(5):512–518PubMedCrossRef
Metadata
Title
Fluid perfused urethral pressure profilometry and Valsalva leak point pressure: a comparative study in a biophysical model of the urethra
Authors
Tim Idzenga
Johan J. M. Pel
Ron van Mastrigt
Publication date
01-08-2007
Publisher
Springer-Verlag
Published in
World Journal of Urology / Issue 4/2007
Print ISSN: 0724-4983
Electronic ISSN: 1433-8726
DOI
https://doi.org/10.1007/s00345-007-0180-9

Other articles of this Issue 4/2007

World Journal of Urology 4/2007 Go to the issue