Skip to main content
Top
Published in: European Radiology 3/2006

01-03-2006 | Musculoskeletal

Ferumoxtran-10-enhanced MR imaging of the bone marrow before and after conditioning therapy in patients with non-Hodgkin lymphomas

Authors: Stephan Metz, Stefanie Lohr, Marcus Settles, Ambros Beer, Klaus Woertler, Ernst J. Rummeny, Heike E. Daldrup‒Link

Published in: European Radiology | Issue 3/2006

Login to get access

Abstract

To quantify permeability changes of the “blood–bone marrow barrier” (BMB) and to detect malignant bone marrow infiltrations before and after conditioning therapy for subsequent leukapheresis using ferumoxtran-10-enhanced magnetic resonance (MR) imaging. Twenty-two patients with malignant non-Hodgkin lymphomas (NHL), including 9 patients (group A) before and 13 patients (group B) after conditioning therapy, underwent MR of the spine before and after infusion of ferumoxtran-10 (0.045 mmol Fe/kg BW). Pulse sequences comprised dynamic T1-GE and pre- and post-contrast T1-SE and STIR sequences. Dynamic ΔSI-data were correlated with the quantity of mobilized CD34+ cells. In addition, the number of focal bone marrow lesions was compared before and after ferumoxtran-10 administration. Dynamic ΔSI-data were higher in group B than in group A, indicating an increased BMB permeability after conditioning therapy. However, ΔSI-data did not correlate with the quantity of mobilized CD34+ cells. Ferumoxtran-10-enhanced STIR images demonstrated a significant signal decline of the normal, non-neoplastic bone marrow and a significantly increased detection of focal neoplastic lesions compared to pre-contrast images (P<0.05). Ferumoxtran-10 depicted the bone marrow response to conditioning therapy by an increase in BMB-permeability, which, however, did not correlate with the number of mobilized CD34+ cells. Ferumoxtran-10 improved the detection of focal bone marrow lesions significantly (P<0.05).
Literature
1.
go back to reference Frank H, Weissleder R, Brady TJ (1994) Enhancement of MR angiography with iron oxide: preliminary studies in whole-blood phantom and in animals. AJR 162:209–213PubMed Frank H, Weissleder R, Brady TJ (1994) Enhancement of MR angiography with iron oxide: preliminary studies in whole-blood phantom and in animals. AJR 162:209–213PubMed
2.
go back to reference Stillman AE, Wilke N, Li D, Haacke M, McLachlan S (1996) Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. J Comput Assist Tomogr 20:51–55CrossRefPubMed Stillman AE, Wilke N, Li D, Haacke M, McLachlan S (1996) Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. J Comput Assist Tomogr 20:51–55CrossRefPubMed
3.
go back to reference Brasch RC, Shames DM, Cohen FM, Kuwatsuru R, Neuder M, Mann JS, Vexler V, Muhler A, Rosenau W (1994) Quantification of capillary permeability to macromolecular magnetic resonance imaging contrast media in experimental mammary adenocarcinomas. Invest Radiol 29(Suppl. 2):8–11CrossRef Brasch RC, Shames DM, Cohen FM, Kuwatsuru R, Neuder M, Mann JS, Vexler V, Muhler A, Rosenau W (1994) Quantification of capillary permeability to macromolecular magnetic resonance imaging contrast media in experimental mammary adenocarcinomas. Invest Radiol 29(Suppl. 2):8–11CrossRef
4.
go back to reference Wiener EC, Brechbiel MW, Brothers H, Magin RL, Gansow OA, Tomalia DA, Lauterbur PC (1994) Dendrimer-based metal chelates: a new class of magnetic resonance imaging contrast agents. Magn Reson Med 31:1–8PubMedCrossRef Wiener EC, Brechbiel MW, Brothers H, Magin RL, Gansow OA, Tomalia DA, Lauterbur PC (1994) Dendrimer-based metal chelates: a new class of magnetic resonance imaging contrast agents. Magn Reson Med 31:1–8PubMedCrossRef
5.
go back to reference Cohen FM, Kuwatsuru R, Shames DM, Neuder M, Mann JS, Vexler V, Rosenau W, Brasch RC (1994) Contrast-enhanced magnetic resonance imaging estimation of altered capillary permeability in experimental mammary carcinomas after X-irradiation. Invest Radiol 29:970–977PubMedCrossRef Cohen FM, Kuwatsuru R, Shames DM, Neuder M, Mann JS, Vexler V, Rosenau W, Brasch RC (1994) Contrast-enhanced magnetic resonance imaging estimation of altered capillary permeability in experimental mammary carcinomas after X-irradiation. Invest Radiol 29:970–977PubMedCrossRef
6.
go back to reference Parmelee DJ, Walovitch RC, Ouellet HS, Lauffer RB (1997) Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging. Invest Radiol 32:741–747PubMedCrossRef Parmelee DJ, Walovitch RC, Ouellet HS, Lauffer RB (1997) Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging. Invest Radiol 32:741–747PubMedCrossRef
7.
go back to reference Brasch R, Pham C, Shames D, Roberts T, van Dijke K, van Bruggen N, Mann J, Ostrowitzki S, Melnyk O (1997) Assessing tumor angiogenesis using macromolecular MR imaging contrast media. J Magn Reson Imaging 7:68–74PubMedCrossRef Brasch R, Pham C, Shames D, Roberts T, van Dijke K, van Bruggen N, Mann J, Ostrowitzki S, Melnyk O (1997) Assessing tumor angiogenesis using macromolecular MR imaging contrast media. J Magn Reson Imaging 7:68–74PubMedCrossRef
8.
go back to reference Weissleder R, Elizondo G, Wittenberg J, Rabito C, Bengele H, Josephson L (1990) Ultrasmall superparamagnetic iron oxide: Characterization of a new class of contrast agents for MR imaging. Radiology 175:489–493PubMed Weissleder R, Elizondo G, Wittenberg J, Rabito C, Bengele H, Josephson L (1990) Ultrasmall superparamagnetic iron oxide: Characterization of a new class of contrast agents for MR imaging. Radiology 175:489–493PubMed
9.
go back to reference Vassallo P, Matei C, Heston WD, McLachlan SJ, Koutcher JA, Castellino RA (1994) AMI-227-enhanced MR lymphography: usefulness for differentiating reactive from tumor-bearing lymph nodes. Radiology 193:501–506PubMed Vassallo P, Matei C, Heston WD, McLachlan SJ, Koutcher JA, Castellino RA (1994) AMI-227-enhanced MR lymphography: usefulness for differentiating reactive from tumor-bearing lymph nodes. Radiology 193:501–506PubMed
10.
go back to reference Daldrup–Link HE, Rummeny EJ, Ihssen B, Kienast J, Link TM (2002) Iron-oxide-enhanced MR imaging of bone marrow with non-Hodgkin's lymphoma: differentiation between tumor infiltration and hypercellular bone marrow. Eur Radiol 12:1557–1566PubMedCrossRef Daldrup–Link HE, Rummeny EJ, Ihssen B, Kienast J, Link TM (2002) Iron-oxide-enhanced MR imaging of bone marrow with non-Hodgkin's lymphoma: differentiation between tumor infiltration and hypercellular bone marrow. Eur Radiol 12:1557–1566PubMedCrossRef
11.
go back to reference Tavassoli M, Yoffey J (1983) Bone marrow structure and function. A.R. Liss, New York Tavassoli M, Yoffey J (1983) Bone marrow structure and function. A.R. Liss, New York
12.
go back to reference Shirota T, Tavassoli M (1992) Alterations of bone marrow sinus endothelium induced by ionizing irradiatio: Implications in the homing of intravenously transplanted marrow cells. Blood Cells 18:197–214PubMed Shirota T, Tavassoli M (1992) Alterations of bone marrow sinus endothelium induced by ionizing irradiatio: Implications in the homing of intravenously transplanted marrow cells. Blood Cells 18:197–214PubMed
13.
go back to reference Hudson G, Yoffey J (1968) Ultrastructure of reticuloendothelial elements in guinea pig bone marrow. J Anat 103:515–525PubMed Hudson G, Yoffey J (1968) Ultrastructure of reticuloendothelial elements in guinea pig bone marrow. J Anat 103:515–525PubMed
14.
go back to reference Daldrup H, Link T, Blasius S, Strozyk A, Könemann S, Jürgens H, Rummeny E (1999) Monitoring radiation induced changes in bone marrow histopathology with ultra-small superparamagnetic iron oxide (USPIO)-enhanced MRI. J Magn Reson Imaging 9:643–652CrossRefPubMed Daldrup H, Link T, Blasius S, Strozyk A, Könemann S, Jürgens H, Rummeny E (1999) Monitoring radiation induced changes in bone marrow histopathology with ultra-small superparamagnetic iron oxide (USPIO)-enhanced MRI. J Magn Reson Imaging 9:643–652CrossRefPubMed
15.
go back to reference Vande Berg BC, Lecouvet FE, Kanku JP, Jamart J, Van Beers BE, Maldague B, Malghem J (1999) Ferumoxides-enhanced quantitative magnetic resonance imaging of the normal and abnormal bone marrow: preliminary assessment. J Magn Reson Imaging 9:322–328PubMedCrossRef Vande Berg BC, Lecouvet FE, Kanku JP, Jamart J, Van Beers BE, Maldague B, Malghem J (1999) Ferumoxides-enhanced quantitative magnetic resonance imaging of the normal and abnormal bone marrow: preliminary assessment. J Magn Reson Imaging 9:322–328PubMedCrossRef
16.
go back to reference Shirota T, Tavassoli M (1991) Cyclophosphamide-induced alterations of bone marrow endothelium: implications in homing of marrow cells after transplantation. Exp Hematol 19:369–373PubMed Shirota T, Tavassoli M (1991) Cyclophosphamide-induced alterations of bone marrow endothelium: implications in homing of marrow cells after transplantation. Exp Hematol 19:369–373PubMed
17.
go back to reference Harousseau JL, Shaughnessy J Jr, Richardson P (2004). Multiple myeloma. Hematology (Am Soc Hematol Educ Program) 237–256 Harousseau JL, Shaughnessy J Jr, Richardson P (2004). Multiple myeloma. Hematology (Am Soc Hematol Educ Program) 237–256
18.
go back to reference Jung CW (1995) Surface properties of superparamagnetic iron oxide MR contrast agents: ferrumoxides, ferrumoxtran, ferrumoxisil. Magn Res Imag 13:675–691CrossRef Jung CW (1995) Surface properties of superparamagnetic iron oxide MR contrast agents: ferrumoxides, ferrumoxtran, ferrumoxisil. Magn Res Imag 13:675–691CrossRef
19.
go back to reference Weissleder R, Stark D, Engelstad B, Bacon B, Compton C (1989) Superparamagnetic iron oxide: pharmacokinetics and toxicity. Am J Roentgenol 152:167–173 Weissleder R, Stark D, Engelstad B, Bacon B, Compton C (1989) Superparamagnetic iron oxide: pharmacokinetics and toxicity. Am J Roentgenol 152:167–173
20.
go back to reference Chambon C, Clement O, Le Blanche A, Schouman–Claeys E, Frija G (1993) Superparamagnetic iron oxides as positive contrast agents: in vitro and in vivo evidence. Magn Res Imag 11:509–519CrossRef Chambon C, Clement O, Le Blanche A, Schouman–Claeys E, Frija G (1993) Superparamagnetic iron oxides as positive contrast agents: in vitro and in vivo evidence. Magn Res Imag 11:509–519CrossRef
21.
go back to reference Guimaraes R, Clement O, Bittoun J, Carnot F, Frija G (1993) MR lymphography with superparamagnetic iron nanoparticles in rats: pathologic basis for contrast enhancement. AJR 162:201–207 Guimaraes R, Clement O, Bittoun J, Carnot F, Frija G (1993) MR lymphography with superparamagnetic iron nanoparticles in rats: pathologic basis for contrast enhancement. AJR 162:201–207
22.
go back to reference Brillet PY, Gazeau F, Luciani A, Bessoud B, Cuenod CA, Siauve N, Pons JN, Poupon J, Clement O (2005). Evaluation of tumoral enhancement by superparamagnetic iron oxide particles: comparative studies with ferumoxtran and anionic iron oxide nanoparticles. Eur Radiol 15:1369–1377CrossRefPubMed Brillet PY, Gazeau F, Luciani A, Bessoud B, Cuenod CA, Siauve N, Pons JN, Poupon J, Clement O (2005). Evaluation of tumoral enhancement by superparamagnetic iron oxide particles: comparative studies with ferumoxtran and anionic iron oxide nanoparticles. Eur Radiol 15:1369–1377CrossRefPubMed
23.
go back to reference Metz S, Bonaterra G, Rudelius M, Settles M, Rummeny EJ, Daldrup–Link HE (2004). Capacity of human monocytes to phagocytose approved iron oxide MR contrast agents in vitro. Eur Radiol 14:1851–1858PubMedCrossRef Metz S, Bonaterra G, Rudelius M, Settles M, Rummeny EJ, Daldrup–Link HE (2004). Capacity of human monocytes to phagocytose approved iron oxide MR contrast agents in vitro. Eur Radiol 14:1851–1858PubMedCrossRef
24.
go back to reference Shames DM, Kuwatsuru R, Vexler V, Muhler A, Brasch RC (1993) Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: a quantitative non-invasive technique. Magn Reson Med 29:616–622PubMedCrossRef Shames DM, Kuwatsuru R, Vexler V, Muhler A, Brasch RC (1993) Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: a quantitative non-invasive technique. Magn Reson Med 29:616–622PubMedCrossRef
25.
go back to reference Iizuka–Mikami M, Nagai K, Yoshida K, Sugihara T, Suetsugu Y, Mikami M, Tamada T, Imai S, Kajihara Y, Fukunaga M (2004). Detection of bone marrow and extramedullary involvement in patients with non-Hodgkin's lymphoma by whole-body MRI: comparison with bone and 67Ga scintigraphies. Eur Radiol 14:1074–1081PubMedCrossRef Iizuka–Mikami M, Nagai K, Yoshida K, Sugihara T, Suetsugu Y, Mikami M, Tamada T, Imai S, Kajihara Y, Fukunaga M (2004). Detection of bone marrow and extramedullary involvement in patients with non-Hodgkin's lymphoma by whole-body MRI: comparison with bone and 67Ga scintigraphies. Eur Radiol 14:1074–1081PubMedCrossRef
Metadata
Title
Ferumoxtran-10-enhanced MR imaging of the bone marrow before and after conditioning therapy in patients with non-Hodgkin lymphomas
Authors
Stephan Metz
Stefanie Lohr
Marcus Settles
Ambros Beer
Klaus Woertler
Ernst J. Rummeny
Heike E. Daldrup‒Link
Publication date
01-03-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-0045-9

Other articles of this Issue 3/2006

European Radiology 3/2006 Go to the issue