Abstract

Regadenoson (REG), a selective A2A receptor vasodilator, has not been widely evaluated in stress echocardiography (SE). We report results of 45 patients participating in REG + atropine (REGAT) SE protocol conducted in a single-center prospective trial. The REGAT study enrolled subjects before a clinically indicated cardiac catheterization for suspected coronary artery disease (CAD). After rest imaging, a 2 mg Atropine (AT) bolus followed by 400 mcg of REG was given. Standard stress imaging views were obtained and interpreted in blinded fashion. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) were calculated using cardiac catheterization >70 % stenosis as gold standard. Additional endpoints included major adverse cardiac events (MACE) and patient questionnaire responses. The mean duration of REGAT was 18 ± 7.2 min. There were no MACE, with only transient side-effects of dry mouth, shortness of breath, and headache. The incidence of significant CAD was 51.1 %. The sensitivity and specificity for significant stenosis was 60.9 and 86.4 %, with a PPV and NPV of 82.4 and 67.9 %. By coronary territories, the sensitivity, specificity, PPV, and NPV were: left anterior descending artery 58.8, 92.9, 83.3, and 78.8 %; left circumflex artery 6.7, 93.3, 33.3, and 67.7 %; and right coronary artery 16.7, 93.9, 50, and 75.6 %. Over 90 % of subjects reported feeling comfortable, with 83 % preferring REGAT as a future stress modality. The REGAT protocol is fast, safe, and well-tolerated with good specificity for CAD detection, but its low sensitivity and NPV precludes it from being an imaging modality for routine use.
Literature
1.
go back to reference Salustri A, Fioretti PM, McNeill AJ, Pozzoli MM, Roelandt JR (1992) Pharmacological stress echocardiography in the diagnosis of coronary artery disease and myocardial ischaemia: a comparison between dobutamine and dipyridamole. Eur Heart J 13:1356–1362PubMed Salustri A, Fioretti PM, McNeill AJ, Pozzoli MM, Roelandt JR (1992) Pharmacological stress echocardiography in the diagnosis of coronary artery disease and myocardial ischaemia: a comparison between dobutamine and dipyridamole. Eur Heart J 13:1356–1362PubMed
2.
go back to reference Picano E, Bedetti G, Varga A, Cseh E (2000) The comparable diagnostic accuracies of dobutamine-stress and dipyridamole-stress echocardiographies: a meta-analysis. Coron Artery Dis 11:151–159PubMedCrossRef Picano E, Bedetti G, Varga A, Cseh E (2000) The comparable diagnostic accuracies of dobutamine-stress and dipyridamole-stress echocardiographies: a meta-analysis. Coron Artery Dis 11:151–159PubMedCrossRef
3.
go back to reference Astarita C, Palinkas A, Nicolai E, Maresca FS, Varga A, Picano E (2001) Dipyridamole-atropine stress echocardiography versus exercise SPECT scintigraphy for detection of coronary artery disease in hypertensives with positive exercise test. J Hypertens 19:495–502PubMedCrossRef Astarita C, Palinkas A, Nicolai E, Maresca FS, Varga A, Picano E (2001) Dipyridamole-atropine stress echocardiography versus exercise SPECT scintigraphy for detection of coronary artery disease in hypertensives with positive exercise test. J Hypertens 19:495–502PubMedCrossRef
4.
go back to reference Scherhag AW, Pfleger S, Schreckenberger AB, Gruttner J, Voelker W, Staedt U, Heene DL (1997) Detection of patients with restenosis after PTCA by dipyridamole-atropine-stress-echocardiography. Int J Card Imaging 13:115–123PubMedCrossRef Scherhag AW, Pfleger S, Schreckenberger AB, Gruttner J, Voelker W, Staedt U, Heene DL (1997) Detection of patients with restenosis after PTCA by dipyridamole-atropine-stress-echocardiography. Int J Card Imaging 13:115–123PubMedCrossRef
5.
go back to reference Lanzarini L, Fetiveau R, Poli A, Diotallevi P, Barberis P, Previtali M (1995) Results of dipyridamole plus atropine echo stress test for the diagnosis of coronary artery disease. Int J Card Imaging 11:233–240PubMedCrossRef Lanzarini L, Fetiveau R, Poli A, Diotallevi P, Barberis P, Previtali M (1995) Results of dipyridamole plus atropine echo stress test for the diagnosis of coronary artery disease. Int J Card Imaging 11:233–240PubMedCrossRef
6.
go back to reference Fukai T, Koyanagi S, Tashiro H, Ichiki T, Tsutsui H, Matsumoto T, Takeshita A (1995) Adenosine triphosphate stress echocardiography in the detection of myocardial ischemia. Am J Card Imaging 9:237–244PubMed Fukai T, Koyanagi S, Tashiro H, Ichiki T, Tsutsui H, Matsumoto T, Takeshita A (1995) Adenosine triphosphate stress echocardiography in the detection of myocardial ischemia. Am J Card Imaging 9:237–244PubMed
7.
go back to reference Tawa CB, Baker WB, Kleiman NS, Trakhtenbroit A, Desir R, Zoghbi WA (1996) Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease. J Am Soc Echocardiogr 9:33–43PubMedCrossRef Tawa CB, Baker WB, Kleiman NS, Trakhtenbroit A, Desir R, Zoghbi WA (1996) Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease. J Am Soc Echocardiogr 9:33–43PubMedCrossRef
8.
go back to reference Iskandrian AE, Bateman TM, Belardinelli L, Blackburn B, Cerqueira MD, Hendel RC, Lieu H, Mahmarian JJ, Olmsted A, Underwood SR, Vitola J, Wang W (2007) Adenosine versus regadenoson comparative evaluation in myocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trial. J Nucl Cardiol 14:645–658PubMedCrossRef Iskandrian AE, Bateman TM, Belardinelli L, Blackburn B, Cerqueira MD, Hendel RC, Lieu H, Mahmarian JJ, Olmsted A, Underwood SR, Vitola J, Wang W (2007) Adenosine versus regadenoson comparative evaluation in myocardial perfusion imaging: results of the ADVANCE phase 3 multicenter international trial. J Nucl Cardiol 14:645–658PubMedCrossRef
9.
go back to reference Mahmarian JJ, Cerqueira MD, Iskandrian AE, Bateman TM, Thomas GS, Hendel RC, Moye LA, Olmsted AW (2009) Regadenoson induces comparable left ventricular perfusion defects as adenosine: a quantitative analysis from the ADVANCE MPI 2 trial. JACC Cardiovasc Imaging 2:959–968PubMedCrossRef Mahmarian JJ, Cerqueira MD, Iskandrian AE, Bateman TM, Thomas GS, Hendel RC, Moye LA, Olmsted AW (2009) Regadenoson induces comparable left ventricular perfusion defects as adenosine: a quantitative analysis from the ADVANCE MPI 2 trial. JACC Cardiovasc Imaging 2:959–968PubMedCrossRef
10.
go back to reference Cerqueira MD, Nguyen P, Staehr P, Underwood SR, Iskandrian AE (2008) Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging integrated ADVANCE-MPI trial results. JACC Cardiovasc Imaging 1:307–316PubMedCrossRef Cerqueira MD, Nguyen P, Staehr P, Underwood SR, Iskandrian AE (2008) Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging integrated ADVANCE-MPI trial results. JACC Cardiovasc Imaging 1:307–316PubMedCrossRef
11.
go back to reference Takeishi Y, Chiba J, Abe S, Ikeda K, Tomoike H (1994) Adenosine-echocardiography for the detection of coronary artery disease. J Cardiol 24:1–7PubMed Takeishi Y, Chiba J, Abe S, Ikeda K, Tomoike H (1994) Adenosine-echocardiography for the detection of coronary artery disease. J Cardiol 24:1–7PubMed
12.
go back to reference Harada M, Okura K, Nishizawa S, Inoue T, Sakai H, Lee T, Sugiyama Y, Suzuki M, Hirai H, Yamaguchi T (1998) Detection of coronary artery disease by adenosine triphosphate stress echocardiography: comparison with adenosine triphosphate stress thallium myocardial scintigraphy and coronary angiography. J Cardiol 32:163–171 (in Japanese)PubMed Harada M, Okura K, Nishizawa S, Inoue T, Sakai H, Lee T, Sugiyama Y, Suzuki M, Hirai H, Yamaguchi T (1998) Detection of coronary artery disease by adenosine triphosphate stress echocardiography: comparison with adenosine triphosphate stress thallium myocardial scintigraphy and coronary angiography. J Cardiol 32:163–171 (in Japanese)PubMed
13.
go back to reference Picano E, Pingitore A, Conti U, Kozakova M, Boem A, Cabani E, Ciuti M, Distante A, L’Abbate A (1993) Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dipyridamole echocardiography. Eur Heart J 14:1216–1222PubMedCrossRef Picano E, Pingitore A, Conti U, Kozakova M, Boem A, Cabani E, Ciuti M, Distante A, L’Abbate A (1993) Enhanced sensitivity for detection of coronary artery disease by addition of atropine to dipyridamole echocardiography. Eur Heart J 14:1216–1222PubMedCrossRef
14.
go back to reference Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS (2006) Stress protocols and tracers. J Nucl Cardiol 13:e80–e90PubMedCrossRef Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS (2006) Stress protocols and tracers. J Nucl Cardiol 13:e80–e90PubMedCrossRef
15.
go back to reference Ranhosky A, Kempthorne-Rawson J (1990) The safety of intravenous dipyridamole thallium myocardial perfusion imaging. Intravenous Dipyridamole Thallium Imaging Study Group. Circulation 81:1205–1209PubMedCrossRef Ranhosky A, Kempthorne-Rawson J (1990) The safety of intravenous dipyridamole thallium myocardial perfusion imaging. Intravenous Dipyridamole Thallium Imaging Study Group. Circulation 81:1205–1209PubMedCrossRef
16.
go back to reference Mulvagh SL, Rakowski H, Vannan MA, Abdelmoneim SS, Becher H, Bierig SM, Burns PN, Castello R, Coon PD, Hagen ME, Jollis JG, Kimball TR, Kitzman DW, Kronzon I, Labovitz AJ, Lang RM, Mathew J, Moir WS, Nagueh SF, Pearlman AS, Perez JE, Porter TR, Rosenbloom J, Strachan GM, Thanigaraj S, Wei K, Woo A, Yu EH, Zoghbi WA (2008) American Society of Echocardiography consensus statement on the clinical applications of ultrasonic contrast agents in echocardiography. J Am Soc Echocardiogr 21:1179–1201PubMedCrossRef Mulvagh SL, Rakowski H, Vannan MA, Abdelmoneim SS, Becher H, Bierig SM, Burns PN, Castello R, Coon PD, Hagen ME, Jollis JG, Kimball TR, Kitzman DW, Kronzon I, Labovitz AJ, Lang RM, Mathew J, Moir WS, Nagueh SF, Pearlman AS, Perez JE, Porter TR, Rosenbloom J, Strachan GM, Thanigaraj S, Wei K, Woo A, Yu EH, Zoghbi WA (2008) American Society of Echocardiography consensus statement on the clinical applications of ultrasonic contrast agents in echocardiography. J Am Soc Echocardiogr 21:1179–1201PubMedCrossRef
17.
go back to reference Pellikka PA, Nagueh SF, Elhendy AA, Kuehl CA, Sawada SG (2007) American Society of Echocardiography recommendations for performance, interpretation, and application of stress echocardiography. J Am Soc Echocardiogr 20:1021–1041PubMedCrossRef Pellikka PA, Nagueh SF, Elhendy AA, Kuehl CA, Sawada SG (2007) American Society of Echocardiography recommendations for performance, interpretation, and application of stress echocardiography. J Am Soc Echocardiogr 20:1021–1041PubMedCrossRef
18.
go back to reference Bartunek J, Marwick TH, Rodrigues AC, Vincent M, Van Schuerbeeck E, Sys SU, de Bruyne B (1996) Dobutamine-induced wall motion abnormalities: correlations with myocardial fractional flow reserve and quantitative coronary angiography. J Am Coll Cardiol 27:1429–1436PubMedCrossRef Bartunek J, Marwick TH, Rodrigues AC, Vincent M, Van Schuerbeeck E, Sys SU, de Bruyne B (1996) Dobutamine-induced wall motion abnormalities: correlations with myocardial fractional flow reserve and quantitative coronary angiography. J Am Coll Cardiol 27:1429–1436PubMedCrossRef
19.
go back to reference Iskandrian AS, Verani MS, Heo J (1994) Pharmacologic stress testing: mechanism of action, hemodynamic responses, and results in detection of coronary artery disease. J Nucl Cardiol 1:94–111PubMedCrossRef Iskandrian AS, Verani MS, Heo J (1994) Pharmacologic stress testing: mechanism of action, hemodynamic responses, and results in detection of coronary artery disease. J Nucl Cardiol 1:94–111PubMedCrossRef
20.
go back to reference Chan SY, Brunken RC, Czernin J, Porenta G, Kuhle W, Krivokapich J, Phelps ME, Schelbert HR (1992) Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men. J Am Coll Cardiol 20:979–985PubMedCrossRef Chan SY, Brunken RC, Czernin J, Porenta G, Kuhle W, Krivokapich J, Phelps ME, Schelbert HR (1992) Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men. J Am Coll Cardiol 20:979–985PubMedCrossRef
21.
go back to reference Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD (1990) Effects of adenosine on human coronary arterial circulation. Circulation 82:1595–1606PubMedCrossRef Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD (1990) Effects of adenosine on human coronary arterial circulation. Circulation 82:1595–1606PubMedCrossRef
22.
go back to reference Voudris V, Manginas A, Vassilikos V, Koutelou M, Kantzis J, Cokkinos DV (1996) Coronary flow velocity changes after intravenous dipyridamole infusion: measurements using intravascular Doppler guide wire. A documentation of flow inhomogeneity. J Am Coll Cardiol 27:1148–1155PubMedCrossRef Voudris V, Manginas A, Vassilikos V, Koutelou M, Kantzis J, Cokkinos DV (1996) Coronary flow velocity changes after intravenous dipyridamole infusion: measurements using intravascular Doppler guide wire. A documentation of flow inhomogeneity. J Am Coll Cardiol 27:1148–1155PubMedCrossRef
23.
go back to reference Picano E, Marini C, Pirelli S, Maffei S, Bolognese L, Chiriatti G, Chiarella F, Orlandini A, Seveso G, Colosso MQ et al (1992) Safety of intravenous high-dose dipyridamole echocardiography. The Echo-Persantine International Cooperative Study Group. Am J Cardiol 70:252–258PubMedCrossRef Picano E, Marini C, Pirelli S, Maffei S, Bolognese L, Chiriatti G, Chiarella F, Orlandini A, Seveso G, Colosso MQ et al (1992) Safety of intravenous high-dose dipyridamole echocardiography. The Echo-Persantine International Cooperative Study Group. Am J Cardiol 70:252–258PubMedCrossRef
24.
go back to reference Sicari R, Pasanisi E, Venneri L, Landi P, Cortigiani L, Picano E (2003) Stress echo results predict mortality: a large-scale multicenter prospective international study. J Am Coll Cardiol 41:589–595PubMedCrossRef Sicari R, Pasanisi E, Venneri L, Landi P, Cortigiani L, Picano E (2003) Stress echo results predict mortality: a large-scale multicenter prospective international study. J Am Coll Cardiol 41:589–595PubMedCrossRef
25.
go back to reference Coletta C, Galati A, Greco G, Burattini M, Ricci R, Carunchio A, Fera MS, Bordi L, Ceci V (1995) Prognostic value of high dose dipyridamole echocardiography in patients with chronic coronary artery disease and preserved left ventricular function. J Am Coll Cardiol 26:887–894PubMedCrossRef Coletta C, Galati A, Greco G, Burattini M, Ricci R, Carunchio A, Fera MS, Bordi L, Ceci V (1995) Prognostic value of high dose dipyridamole echocardiography in patients with chronic coronary artery disease and preserved left ventricular function. J Am Coll Cardiol 26:887–894PubMedCrossRef
26.
go back to reference Pingitore A, Picano E, Colosso MQ, Reisenhofer B, Gigli G, Lucarini AR, Petix N, Previtali M, Bigi R, Chiaranda G, Minardi G, de Alcantara M, Lowenstein J, Sclavo MG, Palmieri C, Galati A, Seveso G, Heyman J, Mathias W Jr, Casazza F, Sicari R, Raciti M, Landi P, Marzilli M (1996) The atropine factor in pharmacologic stress echocardiography. Echo Persantine (EPIC) and Echo Dobutamine International Cooperative (EDIC) Study Groups. J Am Coll Cardiol 27:1164–1170PubMedCrossRef Pingitore A, Picano E, Colosso MQ, Reisenhofer B, Gigli G, Lucarini AR, Petix N, Previtali M, Bigi R, Chiaranda G, Minardi G, de Alcantara M, Lowenstein J, Sclavo MG, Palmieri C, Galati A, Seveso G, Heyman J, Mathias W Jr, Casazza F, Sicari R, Raciti M, Landi P, Marzilli M (1996) The atropine factor in pharmacologic stress echocardiography. Echo Persantine (EPIC) and Echo Dobutamine International Cooperative (EDIC) Study Groups. J Am Coll Cardiol 27:1164–1170PubMedCrossRef
27.
go back to reference Cortigiani L, Picano E, Landi P, Previtali M, Pirelli S, Bellotti P, Bigi R, Magaia O, Galati A, Nannini E (1998) Value of pharmacologic stress echocardiography in risk stratification of patients with single-vessel disease: a report from the Echo-Persantine and Echo-Dobutamine International Cooperative Studies. J Am Coll Cardiol 32:69–74PubMedCrossRef Cortigiani L, Picano E, Landi P, Previtali M, Pirelli S, Bellotti P, Bigi R, Magaia O, Galati A, Nannini E (1998) Value of pharmacologic stress echocardiography in risk stratification of patients with single-vessel disease: a report from the Echo-Persantine and Echo-Dobutamine International Cooperative Studies. J Am Coll Cardiol 32:69–74PubMedCrossRef
28.
go back to reference Pingitore A, Picano E, Varga A, Gigli G, Cortigiani L, Previtali M, Minardi G, Colosso MQ, Lowenstein J, Mathias W Jr, Landi P (1999) Prognostic value of pharmacological stress echocardiography in patients with known or suspected coronary artery disease: a prospective, large-scale, multicenter, head-to-head comparison between dipyridamole and dobutamine test. Echo-Persantine International Cooperative (EPIC) and Echo-Dobutamine International Cooperative (EDIC) Study Groups. J Am Coll Cardiol 34:1769–1777PubMedCrossRef Pingitore A, Picano E, Varga A, Gigli G, Cortigiani L, Previtali M, Minardi G, Colosso MQ, Lowenstein J, Mathias W Jr, Landi P (1999) Prognostic value of pharmacological stress echocardiography in patients with known or suspected coronary artery disease: a prospective, large-scale, multicenter, head-to-head comparison between dipyridamole and dobutamine test. Echo-Persantine International Cooperative (EPIC) and Echo-Dobutamine International Cooperative (EDIC) Study Groups. J Am Coll Cardiol 34:1769–1777PubMedCrossRef
29.
go back to reference Cortigiani L, Lombardi M, Michelassi C, Paolini EA, Nannini E (1998) Significance of myocardial ischemic electrocardiographic changes during dipyridamole stress echocardiography. Am J Cardiol 82:1008–1012PubMedCrossRef Cortigiani L, Lombardi M, Michelassi C, Paolini EA, Nannini E (1998) Significance of myocardial ischemic electrocardiographic changes during dipyridamole stress echocardiography. Am J Cardiol 82:1008–1012PubMedCrossRef
30.
go back to reference Marwick T, Willemart B, D’Hondt AM, Baudhuin T, Wijns W, Detry JM, Melin J (1993) Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography. Circulation 87:345–354PubMedCrossRef Marwick T, Willemart B, D’Hondt AM, Baudhuin T, Wijns W, Detry JM, Melin J (1993) Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography. Circulation 87:345–354PubMedCrossRef
31.
go back to reference Kim C, Kwok YS, Heagerty P, Redberg R (2001) Pharmacologic stress testing for coronary disease diagnosis: a meta-analysis. Am Heart J 142:934–944PubMedCrossRef Kim C, Kwok YS, Heagerty P, Redberg R (2001) Pharmacologic stress testing for coronary disease diagnosis: a meta-analysis. Am Heart J 142:934–944PubMedCrossRef
32.
go back to reference Gordi T, Blackburn B, Lieu H (2007) Regadenoson pharmacokinetics and tolerability in subjects with impaired renal function. J Clin Pharmacol 47:825–833PubMedCrossRef Gordi T, Blackburn B, Lieu H (2007) Regadenoson pharmacokinetics and tolerability in subjects with impaired renal function. J Clin Pharmacol 47:825–833PubMedCrossRef
33.
go back to reference Porter TR, Adolphson M, High RR, Smith LM, Olson J, Erdkamp M, Xie F, O’Leary E, Wong BF, Eifert-Rain S, Hagen ME, Abdelmoneim SS, Mulvagh SL (2011) Rapid detection of coronary artery stenoses with real-time perfusion echocardiography during regadenoson stress. Circ Cardiovasc Imaging 4:628–635PubMedCrossRef Porter TR, Adolphson M, High RR, Smith LM, Olson J, Erdkamp M, Xie F, O’Leary E, Wong BF, Eifert-Rain S, Hagen ME, Abdelmoneim SS, Mulvagh SL (2011) Rapid detection of coronary artery stenoses with real-time perfusion echocardiography during regadenoson stress. Circ Cardiovasc Imaging 4:628–635PubMedCrossRef
Metadata
Title
Feasibility, safety and accuracy of regadenoson–atropine (REGAT) stress echocardiography for the diagnosis of coronary artery disease: an angiographic correlative study
Authors
Kamran Shaikh
Dee Dee Wang
Hani Saad
Mohsin Alam
Akshay Khandelwal
Kristen Brooks
Hari Iyer
Phuc Nguyen
Stephanie Boedeker
Karthik Ananthasubramaniam
Publication date
01-03-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0363-6

Other articles of this Issue 3/2014

The International Journal of Cardiovascular Imaging 3/2014 Go to the issue