Speckle tracking echocardiography (STE) is a method of quantitative assessment of myocardial function complementary to ejection fraction and visual evaluation. Standard STE analysis, demands manual tracing of the myocardium whereas automated function imaging (AFI) offers more convenient (based on selection of three points) assessment of longitudinal strain. Nevertheless, feasibility and correlation between both methods were not thoroughly examined, especially during tachycardia at peak stage of dobutamine stress echocardiography (DSE). We performed DSE in 238 patients (pts) with recording of apical views during baseline (0) and peak (1) DSE and analyzed them by STE and AFI. According to angiography, 127/238 pts had significant (≥70 %) lesions in coronary arteries. We assessed correlations between STE and AFI derived peak systolic longitudinal strain values for global and regional parameters, feasibility, time of analysis and interobserver agreement. Global systolic longitudinal strain measured during baseline and peak stage of DSE by AFI showed very good correlation with standard STE parameters, with correlation coefficients r = 0.90 and r = 0.86 respectively (p < 0.0001). For regional parameters correlation coefficients ranged from 0.83 to 0.85 for baseline and from 0.70 to 0.79 for peak DSE. Both methods provided good and similar feasibility with only 1 % segments excluded from analysis at peak stage of DSE with shorter time and lower coefficient of variance offered by AFI. Global and regional longitudinal strain achieved by faster and less operator-dependent AFI method correlate well with standard more time-consuming STE analysis during baseline and peak stage of DSE.
Literature
1.
go back to reference Pellikka PA, Nagueh SF, Elhendy AA, Kuehl CA, Sawada SG (2007) American Society of Echocardiography recommendations for performance, interpretation and application of stress echocardiography. J Am Soc Echocardiogr 20:1021–1041 Pellikka PA, Nagueh SF, Elhendy AA, Kuehl CA, Sawada SG (2007) American Society of Echocardiography recommendations for performance, interpretation and application of stress echocardiography. J Am Soc Echocardiogr 20:1021–1041
2.
go back to reference Sicari R, Nihoyannopoulos P, Evangelista A, Kasprzak J, Lancellotti P, Poldermans D et al (2008) EAE Guidelines Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC). Eur J Echocardiogr 9:415–437PubMedCrossRef Sicari R, Nihoyannopoulos P, Evangelista A, Kasprzak J, Lancellotti P, Poldermans D et al (2008) EAE Guidelines Stress echocardiography expert consensus statement European Association of Echocardiography (EAE) (a registered branch of the ESC). Eur J Echocardiogr 9:415–437PubMedCrossRef
3.
go back to reference Gianrossi R, Detrano R, Mulvihill D, Lehmann K, Dubach P, Colombo A et al (1989) Exercise-induced ST depression in the diagnosis of coronary artery disease. Meta-anal Circ 80:87–98 Gianrossi R, Detrano R, Mulvihill D, Lehmann K, Dubach P, Colombo A et al (1989) Exercise-induced ST depression in the diagnosis of coronary artery disease. Meta-anal Circ 80:87–98
4.
go back to reference Kwok Y, Kim C, Grady D, Segal M, Redberg R (1999) Meta-analysis of exercise testing to detect coronary artery disease in women. Am J Cardiol 83:660–666PubMedCrossRef Kwok Y, Kim C, Grady D, Segal M, Redberg R (1999) Meta-analysis of exercise testing to detect coronary artery disease in women. Am J Cardiol 83:660–666PubMedCrossRef
5.
go back to reference Madler CF, Payne N, Wilkenshoff U, Cohen A, Derumeaux GA, Pierard LA et al (2003) For the MYDISE Study Investigators (Myocardial Doppler in Stress Echocardiography). Non-invasive diagnosis of coronary artery disease by quantitative stress echocardiography: optimal diagnostic models using off-line tissue Doppler in the MYDISE study. Eur Heart J 24:1584–1594PubMedCrossRef Madler CF, Payne N, Wilkenshoff U, Cohen A, Derumeaux GA, Pierard LA et al (2003) For the MYDISE Study Investigators (Myocardial Doppler in Stress Echocardiography). Non-invasive diagnosis of coronary artery disease by quantitative stress echocardiography: optimal diagnostic models using off-line tissue Doppler in the MYDISE study. Eur Heart J 24:1584–1594PubMedCrossRef
6.
go back to reference Kasprzak JD, Paelinck B, Ten Cate FJ, Vletter WB, de Jong N, Poldermans D et al (1999) Second harmonic imaging improves the visualization of left ventricular endocardial border. A comparison of native and contrast-enhanced studies. Am J Cardiol 83:211–217PubMedCrossRef Kasprzak JD, Paelinck B, Ten Cate FJ, Vletter WB, de Jong N, Poldermans D et al (1999) Second harmonic imaging improves the visualization of left ventricular endocardial border. A comparison of native and contrast-enhanced studies. Am J Cardiol 83:211–217PubMedCrossRef
7.
go back to reference Wijns W, Kolh P, Danchin N, Di Mario C, Falk V, Folliguet T et al (2010) The task force on myocardial revascularization of the European society of cardiology (ESC) and the European association for cardio-thoracic surgery (EACTS) developed with the special contribution of the European association for percutaneous cardiovascular interventions (EAPCI) ESC/EACTS guidelines on myocardial revascularisation. Eur Heart J 31:2501–2555PubMedCrossRef Wijns W, Kolh P, Danchin N, Di Mario C, Falk V, Folliguet T et al (2010) The task force on myocardial revascularization of the European society of cardiology (ESC) and the European association for cardio-thoracic surgery (EACTS) developed with the special contribution of the European association for percutaneous cardiovascular interventions (EAPCI) ESC/EACTS guidelines on myocardial revascularisation. Eur Heart J 31:2501–2555PubMedCrossRef
8.
go back to reference Lipiec P, Wejner-Mik P, Krzemińska-Pakuła M, Kuśmierek J, Płachcińska A, Szumiński R et al (2008) Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography. J Am Soc Echocardiogr 21:941–947PubMedCrossRef Lipiec P, Wejner-Mik P, Krzemińska-Pakuła M, Kuśmierek J, Płachcińska A, Szumiński R et al (2008) Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: comparison with 99mTc single photon emission computed tomography. J Am Soc Echocardiogr 21:941–947PubMedCrossRef
9.
go back to reference Geyer H, Carraciolo G, Abe H, Wilansky S, Carerj S, Gentile F et al (2010) Assessment of myocardial mechanics using speckle tracking echocardiography: fundamentals and clinical applications. J Am Soc Echocardiogr 23:351–369PubMedCrossRef Geyer H, Carraciolo G, Abe H, Wilansky S, Carerj S, Gentile F et al (2010) Assessment of myocardial mechanics using speckle tracking echocardiography: fundamentals and clinical applications. J Am Soc Echocardiogr 23:351–369PubMedCrossRef
10.
go back to reference Urheim S, Edvardsen T, Trop H, Angelsen B, Smiseth OA (2000) Myocardial strain by doppler echocardiography: validation of a new method to quantify regional myocardial function. Circulation 102:1158–1164PubMedCrossRef Urheim S, Edvardsen T, Trop H, Angelsen B, Smiseth OA (2000) Myocardial strain by doppler echocardiography: validation of a new method to quantify regional myocardial function. Circulation 102:1158–1164PubMedCrossRef
11.
go back to reference Kowalski M, Herregods MC, Herbots L, Weidemann F, Simmons L, Strotmann J et al (2003) The feasibility of ultrasonic regional strain and strain rate imaging in quantifying dobutamine stress echocardiography. Eur J Echocardiogr 4:81–91PubMedCrossRef Kowalski M, Herregods MC, Herbots L, Weidemann F, Simmons L, Strotmann J et al (2003) The feasibility of ultrasonic regional strain and strain rate imaging in quantifying dobutamine stress echocardiography. Eur J Echocardiogr 4:81–91PubMedCrossRef
12.
go back to reference Voigt J-U, Nixdorff U, Bogdan R, Exner B, Schmiedehausen K, Platsch G et al (2004) Comparison of deformation imaging and velocity imaging for detecting regional inducible ischaemia during dobutamine stress echocardiography. Eur Heart J 25:1517–1525PubMedCrossRef Voigt J-U, Nixdorff U, Bogdan R, Exner B, Schmiedehausen K, Platsch G et al (2004) Comparison of deformation imaging and velocity imaging for detecting regional inducible ischaemia during dobutamine stress echocardiography. Eur Heart J 25:1517–1525PubMedCrossRef
13.
go back to reference Kukulski T, Jamal F, Herbots L, D’hooge J, Bijnens B, Hatle L et al (2003) Identification of acutely ischemic myocardium using ultrasonic strain measurements. A clinical study in patients undergoing coronary angioplasty. J Am Coll Cardiol 41:810–819PubMedCrossRef Kukulski T, Jamal F, Herbots L, D’hooge J, Bijnens B, Hatle L et al (2003) Identification of acutely ischemic myocardium using ultrasonic strain measurements. A clinical study in patients undergoing coronary angioplasty. J Am Coll Cardiol 41:810–819PubMedCrossRef
14.
go back to reference Perk G, Tunick PA, Kronzon I (2007) Non-doppler two-dimensional strain imaging by echocardiography—from technical considerations to clinical applications. J Am Soc Echocardiogr 20:234–243PubMedCrossRef Perk G, Tunick PA, Kronzon I (2007) Non-doppler two-dimensional strain imaging by echocardiography—from technical considerations to clinical applications. J Am Soc Echocardiogr 20:234–243PubMedCrossRef
15.
go back to reference Zhang L, Gao J, Xie M, Yin P, Liu W, Li Y, et al. (2013) Left ventricular three-dimensional global systolic strain by real-time three-dimensional speckle-tracking in children: feasibility, reproducibility, maturational changes, and normal ranges. J Am Soc Echocardiogr. doi: 10.1016/j.echo.2013.05.002 Zhang L, Gao J, Xie M, Yin P, Liu W, Li Y, et al. (2013) Left ventricular three-dimensional global systolic strain by real-time three-dimensional speckle-tracking in children: feasibility, reproducibility, maturational changes, and normal ranges. J Am Soc Echocardiogr. doi: 10.​1016/​j.​echo.​2013.​05.​002
16.
go back to reference Altiok E, Neizel M, Tiemann S, Krass V, Kuhr K, Becker M et al (2012) Quantitative analysis of endocardial and epicardial left ventricular myocardial deformation-comparison of strain-encoded cardiac magnetic resonance imaging with two-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr 25:1179–1188PubMedCrossRef Altiok E, Neizel M, Tiemann S, Krass V, Kuhr K, Becker M et al (2012) Quantitative analysis of endocardial and epicardial left ventricular myocardial deformation-comparison of strain-encoded cardiac magnetic resonance imaging with two-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr 25:1179–1188PubMedCrossRef
17.
go back to reference Belghiti H, Brette S, Lafitte S, Reant P, Picard F, Serri K et al (2008) Automated function imaging: a new operator-independent strain method for assessing left ventricular function. Arch Cardiovasc Dis 101:163–169CrossRef Belghiti H, Brette S, Lafitte S, Reant P, Picard F, Serri K et al (2008) Automated function imaging: a new operator-independent strain method for assessing left ventricular function. Arch Cardiovasc Dis 101:163–169CrossRef
18.
go back to reference Takigiku K, Takeuchi M, Izumi C, Yuda S, Sakata K, Ohte N et al (2012) Normal range of left ventricular 2-dimensional strain—Japanese ultrasound speckle tracking of left ventricle (JUSTICE) study. Circ J 76:2623–2632PubMedCrossRef Takigiku K, Takeuchi M, Izumi C, Yuda S, Sakata K, Ohte N et al (2012) Normal range of left ventricular 2-dimensional strain—Japanese ultrasound speckle tracking of left ventricle (JUSTICE) study. Circ J 76:2623–2632PubMedCrossRef
19.
go back to reference Anwar A, Nosir Y, Alasnag M, Llemit MA, Elhagoly AA, Chamsi-Pasha H (2013) Quantification of left ventricular longitudinal strain by two-dimensional speckle tracking: a comparison between expert and non-expert readers. Int J Cardiovasc Imaging 29:1451–1458PubMedCrossRef Anwar A, Nosir Y, Alasnag M, Llemit MA, Elhagoly AA, Chamsi-Pasha H (2013) Quantification of left ventricular longitudinal strain by two-dimensional speckle tracking: a comparison between expert and non-expert readers. Int J Cardiovasc Imaging 29:1451–1458PubMedCrossRef
20.
go back to reference Elmayergi NH, Goodman JM, Lee LS, Sasson Z (2013) Are measures of left ventricular systolic performance during low dose dobutamine stress echocardiograms repeatable over time? Int J Cardiovasc Imaging 29:1281–1286PubMedCrossRef Elmayergi NH, Goodman JM, Lee LS, Sasson Z (2013) Are measures of left ventricular systolic performance during low dose dobutamine stress echocardiograms repeatable over time? Int J Cardiovasc Imaging 29:1281–1286PubMedCrossRef
21.
22.
go back to reference Chrzanowski Ł, Lipiec P, Krzemińska-Pakuła M, Wejner-Mik P, Jasińska A, Drożdż J et al (2007) Echokardiograficzna ocena odkształcenia lewej komory przy zastosowaniu techniki doplera tkankowego oraz śledzenia markerów akustycznych (speckle tracking). Pol J Cardiol 9:195–202 Chrzanowski Ł, Lipiec P, Krzemińska-Pakuła M, Wejner-Mik P, Jasińska A, Drożdż J et al (2007) Echokardiograficzna ocena odkształcenia lewej komory przy zastosowaniu techniki doplera tkankowego oraz śledzenia markerów akustycznych (speckle tracking). Pol J Cardiol 9:195–202
23.
go back to reference Bansal M, Cho GY, Chan J, Leano R, Haluska BA, Marwick TH (2008) Feasibility and accuracy of different techniques of two-dimensional speckle based strain and validation with harmonic phase magnetic resonance imaging. J Am Soc Echocardiogr 21:1318–1325PubMedCrossRef Bansal M, Cho GY, Chan J, Leano R, Haluska BA, Marwick TH (2008) Feasibility and accuracy of different techniques of two-dimensional speckle based strain and validation with harmonic phase magnetic resonance imaging. J Am Soc Echocardiogr 21:1318–1325PubMedCrossRef
24.
go back to reference Marwick T, Leano RL, Brown J, Sun J-P, Hoffman R, Lysansky P et al (2009) Myocardial strain measurement with 2-dimensional speckle tracking echocardiography. Definition of normal range. J Am Coll Cardiol Imaging 2:80–84CrossRef Marwick T, Leano RL, Brown J, Sun J-P, Hoffman R, Lysansky P et al (2009) Myocardial strain measurement with 2-dimensional speckle tracking echocardiography. Definition of normal range. J Am Coll Cardiol Imaging 2:80–84CrossRef
25.
go back to reference Picano E, Lattanzi F, Orlandini A, Marini C, L’Abbate A (1991) Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol 17:666–669PubMedCrossRef Picano E, Lattanzi F, Orlandini A, Marini C, L’Abbate A (1991) Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol 17:666–669PubMedCrossRef
26.
go back to reference Anand DV, Theodosiadis ID, Senior R (2004) Improved interpretation of dobutamine stress echocardiography following 4 months of systematic training in patients following acute myocardial infarction. Eur J Echocardiogr 5:12–17PubMedCrossRef Anand DV, Theodosiadis ID, Senior R (2004) Improved interpretation of dobutamine stress echocardiography following 4 months of systematic training in patients following acute myocardial infarction. Eur J Echocardiogr 5:12–17PubMedCrossRef
Metadata
Title
Feasibility and correlation of standard 2D speckle tracking echocardiography and automated function imaging derived parameters of left ventricular function during dobutamine stress test
Authors
Karina Wierzbowska-Drabik
Piotr Hamala
Nikolina Roszczyk
Piotr Lipiec
Michał Plewka
Radosław Kręcki
Jarosław Damian Kasprzak
Publication date
01-04-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0386-z

Other articles of this Issue 4/2014

The International Journal of Cardiovascular Imaging 4/2014 Go to the issue