Failure of a balloon to deflate during post dilatation in a coronary artery

Authors: Takuro Takama, Yoshiaki Ito, Hiroshi Ishimori, Reiko Tsukahara, Toshiya Muramatsu

Published in: Cardiovascular Intervention and Therapeutics | Issue 1/2015

Login to get access

Abstract

Entrapment of nondeflated balloon is a rare complication of percutaneous coronary intervention. Sometimes it has hazardous potentials for the patient. We experienced a rare complication of percutaneous coronary intervention (PCI) caused by a defective balloon. We reported this experience and simple bailout technique.
Literature
1.
go back to reference Rizzo TF, Werres R, Ciccone J, Karanam R, Shah S. Entrapment of an angioplasty balloon catheter: a case report. Cathet Cardiovasc Diagn. 1988;14:255–7.PubMedCrossRef Rizzo TF, Werres R, Ciccone J, Karanam R, Shah S. Entrapment of an angioplasty balloon catheter: a case report. Cathet Cardiovasc Diagn. 1988;14:255–7.PubMedCrossRef
2.
go back to reference Alexiou K, Kappert U, Knaut M, Matschke K, Tugtekin SM. Entrapped coronary catheter remnants and stents: must they be surgically removed? Tex Heart Inst J. 2006;33:139–42.PubMedCentralPubMed Alexiou K, Kappert U, Knaut M, Matschke K, Tugtekin SM. Entrapped coronary catheter remnants and stents: must they be surgically removed? Tex Heart Inst J. 2006;33:139–42.PubMedCentralPubMed
3.
5.
go back to reference Shimohara Y, Kobayashi J, Nakajima H, Toda K, Fujita T. Surgical treatment of entrapped intravascular ultrasonography catheter. Gen Thorac Cardiovasc Surg. 2012;. doi:10.1007/s11748-011-0785-1. Shimohara Y, Kobayashi J, Nakajima H, Toda K, Fujita T. Surgical treatment of entrapped intravascular ultrasonography catheter. Gen Thorac Cardiovasc Surg. 2012;. doi:10.​1007/​s11748-011-0785-1.
6.
go back to reference Kawamura A, Asakura Y, Ishikawa S, Asakura K, Okabe T, Yamane A, et al. Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture. Catheter Cardiovasc Interv. 2002;57:239–43.PubMedCrossRef Kawamura A, Asakura Y, Ishikawa S, Asakura K, Okabe T, Yamane A, et al. Extraction of previously deployed stent by an entrapped cutting balloon due to the blade fracture. Catheter Cardiovasc Interv. 2002;57:239–43.PubMedCrossRef
7.
go back to reference Girish MP, Gupta MD, Tyagi S. Entrapped coronary angioplasty stent balloon due to nondeflation: percutaaneous retrieval by a simple technique. Catheter Cardiovasc Interv. 2011;. doi:10.1002/ccd.22617.PubMed Girish MP, Gupta MD, Tyagi S. Entrapped coronary angioplasty stent balloon due to nondeflation: percutaaneous retrieval by a simple technique. Catheter Cardiovasc Interv. 2011;. doi:10.​1002/​ccd.​22617.PubMed
Metadata
Title
Failure of a balloon to deflate during post dilatation in a coronary artery
Authors
Takuro Takama
Yoshiaki Ito
Hiroshi Ishimori
Reiko Tsukahara
Toshiya Muramatsu
Publication date
01-01-2015
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 1/2015
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-014-0249-5

Other articles of this Issue 1/2015

Cardiovascular Intervention and Therapeutics 1/2015 Go to the issue