Skip to main content
Top
Published in: Pediatric Cardiology 7/2012

01-10-2012 | Original Article

Extended Szabo (Anchor-Wire) Technique Concept for Stent Implantation in Congenital Heart Lesions

Authors: Josep Girona, Gerard Martí, Pedro Betrian, Bruno García

Published in: Pediatric Cardiology | Issue 7/2012

Login to get access

Abstract

We report the usefulness of the Szabo (anchor-wire) technique and two modifications of such based on the same concept for stent implantation in congenital heart lesions. The modifications of the original technique are related to the localization of the cell of the stent through which the anchor wire, which stops the stent advancement, is introduced: proximal in the original technique and central or distal in the reported modifications. These techniques were performed in six patients: in two to maintain permeability of the ductus arteriosus, in three to achieve a fenestration of the interatrial septum, and in one to implant a stent in a right ventricle–to–pulmonary artery conduit close to the bifurcation. We describe the technique as well as the most important difficulties and complications encountered. The Szabo or anchor-wire technique concept is a new tool for stent implantation that can provide more accurate stent positioning compared with conventional angiographically guided implantation in different congenital heart defects. As with any new tool, this technique demands a learning curve and knowledge of potential complications.
Literature
1.
go back to reference Applegate RJ, Davis JM, Leonard JC (2008) Treatment of ostial lesions using the Szabo technique: a case series. Catheter Cardiovasc Interv 72(6):823–828PubMedCrossRef Applegate RJ, Davis JM, Leonard JC (2008) Treatment of ostial lesions using the Szabo technique: a case series. Catheter Cardiovasc Interv 72(6):823–828PubMedCrossRef
2.
go back to reference Ferrer-Gracia María-Cruz, Sánchez-Rubio Juan, Calvo-Cebollero Isabel (2011) Stent dislodgement during Szabo technique. Int J Cardiol 147(1):e8–e9PubMedCrossRef Ferrer-Gracia María-Cruz, Sánchez-Rubio Juan, Calvo-Cebollero Isabel (2011) Stent dislodgement during Szabo technique. Int J Cardiol 147(1):e8–e9PubMedCrossRef
3.
go back to reference Kern MJ (2008) Anchoring the stent: comment on treatment of ostial lesions using the Szabo technique. Catheter Cardiovasc Interv 72(6):829–830PubMedCrossRef Kern MJ (2008) Anchoring the stent: comment on treatment of ostial lesions using the Szabo technique. Catheter Cardiovasc Interv 72(6):829–830PubMedCrossRef
4.
go back to reference Kern MJ, Ouellette D, Frianeza T (2006) A new technique to anchor stents for exact placement in ostial stenoses: the stent tail wire or Szabo technique. Catheter Cardiovasc Interv 68(6):901–906PubMedCrossRef Kern MJ, Ouellette D, Frianeza T (2006) A new technique to anchor stents for exact placement in ostial stenoses: the stent tail wire or Szabo technique. Catheter Cardiovasc Interv 68(6):901–906PubMedCrossRef
5.
go back to reference Lampropoulos K, Budts W, Gewillig M (2011) Dual wire technique for aortic coarctation stent placement. Catheter Cardiovasc Interv 78(3):425–427PubMed Lampropoulos K, Budts W, Gewillig M (2011) Dual wire technique for aortic coarctation stent placement. Catheter Cardiovasc Interv 78(3):425–427PubMed
6.
go back to reference Lo H, Kern MJ (2006) Use of a branch wire to anchor stents for exact placement proximal to bifurcation stents: the reverse Szabo technique. Catheter Cardiovasc Interv 67:904–907PubMedCrossRef Lo H, Kern MJ (2006) Use of a branch wire to anchor stents for exact placement proximal to bifurcation stents: the reverse Szabo technique. Catheter Cardiovasc Interv 67:904–907PubMedCrossRef
7.
go back to reference Salazar M, Kern MJ, Patel PM (2009) Exact deployment of stents in ostial renal artery stenosis using the stent tail wire or Szabo technique. Catheter Cardiovasc Interv 74(6):946–950PubMedCrossRef Salazar M, Kern MJ, Patel PM (2009) Exact deployment of stents in ostial renal artery stenosis using the stent tail wire or Szabo technique. Catheter Cardiovasc Interv 74(6):946–950PubMedCrossRef
8.
go back to reference Stumper O, Bhole W, Anderson B, Reinhardt Z, Noonan P, Mehta Ch (2011) A novel technique for stenting pulmonary artery and conduit bifurcation stenosis. Catheter Cardiovasc Interv 78(3):419–424PubMed Stumper O, Bhole W, Anderson B, Reinhardt Z, Noonan P, Mehta Ch (2011) A novel technique for stenting pulmonary artery and conduit bifurcation stenosis. Catheter Cardiovasc Interv 78(3):419–424PubMed
9.
go back to reference Szabo S, Abramowitz B, Vaitkus PT (2005) New technique for aortoostial stent placement. Am J Cardiol 96:212HCrossRef Szabo S, Abramowitz B, Vaitkus PT (2005) New technique for aortoostial stent placement. Am J Cardiol 96:212HCrossRef
Metadata
Title
Extended Szabo (Anchor-Wire) Technique Concept for Stent Implantation in Congenital Heart Lesions
Authors
Josep Girona
Gerard Martí
Pedro Betrian
Bruno García
Publication date
01-10-2012
Publisher
Springer-Verlag
Published in
Pediatric Cardiology / Issue 7/2012
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-012-0231-x

Other articles of this Issue 7/2012

Pediatric Cardiology 7/2012 Go to the issue