Abstract

Background

Ankle-foot orthoses (AFO) are commonly prescribed to provide functional assistance for patients with lower limb injuries or weakness. Their passive mechanical elements can provide some energy return to improve walking ability, but cannot restore plantar flexor push-off. Powered AFOs provide an assistive torque about the ankle to address the limitations of passive devices, but current designs have yet to be implemented on a large scale clinically. Purpose: To compare passive AFOs to a new untethered, powered AFO design in a clinical population with lower limb reconstruction.

Methods

A crossover study design, conducted on three individuals with lower limb reconstruction, compared gait mechanics at a standardized speed (based on leg length) in 4 AFO conditions: 1. None (shoes only), 2. Blue Rocker (BR, Allard, USA), 3. Intrepid Dynamic Exoskeletal Orthosis (IDEO), and 4. PowerFoot Orthosis (PFO BionX Medical Technologies, Inc.). The PFO was a custom, battery-powered device whose damping and power were capable to being tuned to meet patient needs. Subjects performed biomechanical gait analysis and metabolic testing at slow, moderate and fast speeds. Dependent variables included total limb power (calculated using a unified deformable segment model), mechanical work, mechanical efficiency, ankle motion, net metabolic cost across three speeds, and performance measures were calculated. Effect sizes (d) were calculated and d > 0.80 denoted a large effect.

Results

Net positive work (d > 1.17) and efficiency (d > 1.43) were greatest in the PFO. There were large effects for between limb differences in positive work for all conditions except the PFO (d = 0.75). The PFO normalized efficiency between the affected and unaffected limbs (d = 0.50), whereas efficiency was less on the affected limb for all other conditions (d > 1.69). Metabolic rate was not consistently lowest in any one AFO condition across speeds. Despite some positive results of the PFO, patient preferred their daily use AFO (2 IDEO, 1 BR). All participants indicated that mass and size were concerns with using the PFO.

Conclusions

A novel PFO resulted in more biomimetic mechanical work and efficiency than commercially-available and custom passive AFO models. Although the powered AFO provided some biomechanical benefits, further improvements are warranted to improve patient satisfaction.
Literature
1.
go back to reference Bosse MJ, et al. An analysis of outcomes of reconstruction or amputation after leg-threatening injuries. N Engl J Med. 2002;347(24):1924–31.CrossRef Bosse MJ, et al. An analysis of outcomes of reconstruction or amputation after leg-threatening injuries. N Engl J Med. 2002;347(24):1924–31.CrossRef
2.
go back to reference Neptune RR, Kautz SA, Zajac FE. Contributions of the individual ankle plantar flexors to support, forward progression and swing initiation during walking. J Biomech. 2001;34(11):1387–98.CrossRef Neptune RR, Kautz SA, Zajac FE. Contributions of the individual ankle plantar flexors to support, forward progression and swing initiation during walking. J Biomech. 2001;34(11):1387–98.CrossRef
3.
go back to reference Liu MQ, et al. Muscles that support the body also modulate forward progression during walking. J Biomech. 2006;39(14):2623–30.CrossRef Liu MQ, et al. Muscles that support the body also modulate forward progression during walking. J Biomech. 2006;39(14):2623–30.CrossRef
4.
go back to reference Allen JL, Neptune RR. Three-dimensional modular control of human walking. J Biomech. 2012;45(12):2157–63.CrossRef Allen JL, Neptune RR. Three-dimensional modular control of human walking. J Biomech. 2012;45(12):2157–63.CrossRef
5.
go back to reference Pandy MG, Lin YC, Kim HJ. Muscle coordination of mediolateral balance in normal walking. J Biomech. 2010;43(11):2055–64.CrossRef Pandy MG, Lin YC, Kim HJ. Muscle coordination of mediolateral balance in normal walking. J Biomech. 2010;43(11):2055–64.CrossRef
6.
go back to reference Inman, V.T., H.J. Ralston, F. Todd, Human Walking, W.W. Co. 1981, Baltimore. Inman, V.T., H.J. Ralston, F. Todd, Human Walking, W.W. Co. 1981, Baltimore.
7.
go back to reference Patzkowski JC, et al. Comparative effect of orthosis design on functional performance. J Bone Joint Surg Am. 2012;94(6):507–15.CrossRef Patzkowski JC, et al. Comparative effect of orthosis design on functional performance. J Bone Joint Surg Am. 2012;94(6):507–15.CrossRef
8.
go back to reference Farris DJ, Sawicki GS. The mechanics and energetics of human walking and running: a joint level perspective. J R Soc Interface. 2012;9(66):110–8.CrossRef Farris DJ, Sawicki GS. The mechanics and energetics of human walking and running: a joint level perspective. J R Soc Interface. 2012;9(66):110–8.CrossRef
9.
go back to reference Haight DJ, Russell Esposito E, Wilken JM. Biomechanics of uphill walking using custom ankle-foot orthoses of three different stiffnesses. Gait Posture. 2015;41(3):750–6.CrossRef Haight DJ, Russell Esposito E, Wilken JM. Biomechanics of uphill walking using custom ankle-foot orthoses of three different stiffnesses. Gait Posture. 2015;41(3):750–6.CrossRef
10.
go back to reference Bedigrew KM, et al. Can an integrated orthotic and rehabilitation program decrease pain and improve function after lower extremity trauma? Clin Orthop Relat Res. 2014;472(10):3017–25.CrossRef Bedigrew KM, et al. Can an integrated orthotic and rehabilitation program decrease pain and improve function after lower extremity trauma? Clin Orthop Relat Res. 2014;472(10):3017–25.CrossRef
11.
go back to reference Russell Esposito E, et al. Gait biomechanics following lower extremity trauma: amputation vs. reconstruction. Gait Posture. 2017;54:167–73.CrossRef Russell Esposito E, et al. Gait biomechanics following lower extremity trauma: amputation vs. reconstruction. Gait Posture. 2017;54:167–73.CrossRef
12.
go back to reference Russell Esposito E, et al. How does ankle-foot orthosis stiffness affect gait in patients with lower limb salvage? Clin Orthop Relat Res. 2014;472(10):3026–35.CrossRef Russell Esposito E, et al. How does ankle-foot orthosis stiffness affect gait in patients with lower limb salvage? Clin Orthop Relat Res. 2014;472(10):3026–35.CrossRef
13.
go back to reference Ranz EC, et al. The influence of passive-dynamic ankle-foot orthosis bending axis location on gait performance in individuals with lower-limb impairments. Clin Biomech (Bristol, Avon). 2016;37:13–21.CrossRef Ranz EC, et al. The influence of passive-dynamic ankle-foot orthosis bending axis location on gait performance in individuals with lower-limb impairments. Clin Biomech (Bristol, Avon). 2016;37:13–21.CrossRef
14.
go back to reference Collins SH, Wiggin MB, Sawicki GS. Reducing the energy cost of human walking using an unpowered exoskeleton. Nature. 2015;522(7555):212.CrossRef Collins SH, Wiggin MB, Sawicki GS. Reducing the energy cost of human walking using an unpowered exoskeleton. Nature. 2015;522(7555):212.CrossRef
15.
go back to reference Ferris DP, Czerniecki JM, Hannaford B. An ankle-foot orthosis powered by artificial pneumatic muscles. J Appl Biomech. 2005;21(2):189–97.CrossRef Ferris DP, Czerniecki JM, Hannaford B. An ankle-foot orthosis powered by artificial pneumatic muscles. J Appl Biomech. 2005;21(2):189–97.CrossRef
16.
go back to reference Chin R, et al. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop. J Neuroeng Rehabil. 2009;6(19):19.CrossRef Chin R, et al. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop. J Neuroeng Rehabil. 2009;6(19):19.CrossRef
17.
go back to reference Shorter KA, et al. A portable powered ankle-foot orthosis for rehabilitation. J Rehabil Res Dev. 2011;48(4):459–72.CrossRef Shorter KA, et al. A portable powered ankle-foot orthosis for rehabilitation. J Rehabil Res Dev. 2011;48(4):459–72.CrossRef
18.
go back to reference Ferris DP, et al. An improved powered ankle-foot orthosis using proportional myoelectric control. Gait Posture. 2006;23(4):425–8.CrossRef Ferris DP, et al. An improved powered ankle-foot orthosis using proportional myoelectric control. Gait Posture. 2006;23(4):425–8.CrossRef
19.
go back to reference Gordon KE, Sawicki GS, Ferris DP. Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis. J Biomech. 2006;39(10):1832–41.CrossRef Gordon KE, Sawicki GS, Ferris DP. Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis. J Biomech. 2006;39(10):1832–41.CrossRef
20.
go back to reference Ward J, et al. Stroke Survivors’ gait adaptations to a powered ankle foot orthosis. Adv Robot. 2011;25(15):1879–901.CrossRef Ward J, et al. Stroke Survivors’ gait adaptations to a powered ankle foot orthosis. Adv Robot. 2011;25(15):1879–901.CrossRef
21.
go back to reference Moltedo M, et al. Powered ankle-foot orthoses: the effects of the assistance on healthy and impaired users while walking. J NeuroEng Rehab. 2018;15:86.CrossRef Moltedo M, et al. Powered ankle-foot orthoses: the effects of the assistance on healthy and impaired users while walking. J NeuroEng Rehab. 2018;15:86.CrossRef
22.
go back to reference Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J Neuroeng Rehabil. 2014;11:80.CrossRef Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J Neuroeng Rehabil. 2014;11:80.CrossRef
23.
go back to reference Malcolm P, et al. A simple exoskeleton that assists plantarflexion can reduce the metabolic cost of human walking. PLoS One. 2013;8(2):e56137.CrossRef Malcolm P, et al. A simple exoskeleton that assists plantarflexion can reduce the metabolic cost of human walking. PLoS One. 2013;8(2):e56137.CrossRef
24.
go back to reference Wiggin, M.B., G.S. Sawicki, S.H. Collins, An exoskeleton using controlled energy storage and release to aid ankle propulsion. 2011 Ieee International Conference on Rehabilitation Robotics (Icorr), 2011.CrossRef Wiggin, M.B., G.S. Sawicki, S.H. Collins, An exoskeleton using controlled energy storage and release to aid ankle propulsion. 2011 Ieee International Conference on Rehabilitation Robotics (Icorr), 2011.CrossRef
25.
go back to reference Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of walking. Conf Proc IEEE Eng Med Biol Soc. 2014;2014:3065–8.PubMed Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of walking. Conf Proc IEEE Eng Med Biol Soc. 2014;2014:3065–8.PubMed
26.
go back to reference Neubauer BC, Nath J, Durfee WK. Design of a portable hydraulic ankle-foot orthosis. Conf Proc IEEE Eng Med Biol Soc. 2014;2014:1182–5.PubMed Neubauer BC, Nath J, Durfee WK. Design of a portable hydraulic ankle-foot orthosis. Conf Proc IEEE Eng Med Biol Soc. 2014;2014:1182–5.PubMed
27.
go back to reference David Li Y, Hsiao-Wecksler ET. Gait mode recognition and control for a portable-powered ankle-foot orthosis. IEEE Int Conf Rehabil Robot. 2013;2013:6650373.PubMed David Li Y, Hsiao-Wecksler ET. Gait mode recognition and control for a portable-powered ankle-foot orthosis. IEEE Int Conf Rehabil Robot. 2013;2013:6650373.PubMed
28.
go back to reference Arazpour M, et al. Gait evaluation of new powered knee-ankle-foot orthosis in able-bodied persons: a pilot study. Prosthetics Orthot Int. 2014;38(1):39–45.CrossRef Arazpour M, et al. Gait evaluation of new powered knee-ankle-foot orthosis in able-bodied persons: a pilot study. Prosthetics Orthot Int. 2014;38(1):39–45.CrossRef
29.
go back to reference Cain SM, Gordon KE, Ferris DP. Locomotor adaptation to a powered ankle-foot orthosis depends on control method. J Neuroeng Rehabil. 2007;4:48.CrossRef Cain SM, Gordon KE, Ferris DP. Locomotor adaptation to a powered ankle-foot orthosis depends on control method. J Neuroeng Rehabil. 2007;4:48.CrossRef
30.
go back to reference Galle S, et al. Enhancing performance during inclined loaded walking with a powered ankle-foot exoskeleton. Eur J Appl Physiol. 2014;114(11):2341–51.CrossRef Galle S, et al. Enhancing performance during inclined loaded walking with a powered ankle-foot exoskeleton. Eur J Appl Physiol. 2014;114(11):2341–51.CrossRef
31.
go back to reference Sawicki GS, Ferris DP. Powered ankle exoskeletons reveal the metabolic cost of plantar flexor mechanical work during walking with longer steps at constant step frequency. J Exp Biol. 2009;212(Pt 1):21–31.CrossRef Sawicki GS, Ferris DP. Powered ankle exoskeletons reveal the metabolic cost of plantar flexor mechanical work during walking with longer steps at constant step frequency. J Exp Biol. 2009;212(Pt 1):21–31.CrossRef
32.
go back to reference Shorter KA, et al. Experimental evaluation of a portable powered ankle-foot orthosis. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:624–7.PubMed Shorter KA, et al. Experimental evaluation of a portable powered ankle-foot orthosis. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:624–7.PubMed
33.
go back to reference Zhang J, et al. Human-in-the-loop optimization of exoskeleton assistance during walking. Science. 2017;356(6344):1280–4.CrossRef Zhang J, et al. Human-in-the-loop optimization of exoskeleton assistance during walking. Science. 2017;356(6344):1280–4.CrossRef
34.
go back to reference Takahashi KZ, Lewek MD, Sawicki GS. A neuromechanics-based powered ankle exoskeleton to assist walking post-stroke: a feasibility study. J Neuroeng Rehabil. 2015;12:23.CrossRef Takahashi KZ, Lewek MD, Sawicki GS. A neuromechanics-based powered ankle exoskeleton to assist walking post-stroke: a feasibility study. J Neuroeng Rehabil. 2015;12:23.CrossRef
35.
go back to reference Yoshizawa N. Powered AFO for Achilles tendon rupture. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:4250–3.PubMed Yoshizawa N. Powered AFO for Achilles tendon rupture. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:4250–3.PubMed
37.
go back to reference Weir LM, Steiner CA, Owens PL. Surgeries in hospital-owned outpatient facilities, 2012. In: Statistical brief; 2015. p. 188. Weir LM, Steiner CA, Owens PL. Surgeries in hospital-owned outpatient facilities, 2012. In: Statistical brief; 2015. p. 188.
38.
go back to reference Control., C.f.D., National Diabetes Statistics Report. 2014. Control., C.f.D., National Diabetes Statistics Report. 2014.
39.
go back to reference Owens JG, et al. Return to running and sports participation after limb salvage. J Trauma. 2011;71(1 Suppl):S120–4.CrossRef Owens JG, et al. Return to running and sports participation after limb salvage. J Trauma. 2011;71(1 Suppl):S120–4.CrossRef
40.
go back to reference Patzkowski JC, et al. Can an ankle-foot orthosis change hearts and minds? J Surg Orthop Adv. 2011;20(1):8–18.PubMed Patzkowski JC, et al. Can an ankle-foot orthosis change hearts and minds? J Surg Orthop Adv. 2011;20(1):8–18.PubMed
41.
go back to reference Blaya JA, Herr H. Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait. IEEE Trans Neural Syst Rehabil Eng. 2004;12(1):24–31.CrossRef Blaya JA, Herr H. Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait. IEEE Trans Neural Syst Rehabil Eng. 2004;12(1):24–31.CrossRef
42.
go back to reference Wilken JM, et al. Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults. Gait & Posture. 2012;35(2):301–7.CrossRef Wilken JM, et al. Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults. Gait & Posture. 2012;35(2):301–7.CrossRef
43.
go back to reference Darter BJ, Rodriguez KM, Wilken JM. Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking. Res Q Exerc Sport. 2013;84(2):223–31.CrossRef Darter BJ, Rodriguez KM, Wilken JM. Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking. Res Q Exerc Sport. 2013;84(2):223–31.CrossRef
44.
go back to reference Wilken JM, et al. Physical performance assessment in military service members. J Am Acad Orthop Surg. 2012;20(Suppl 1):S42–7.CrossRef Wilken JM, et al. Physical performance assessment in military service members. J Am Acad Orthop Surg. 2012;20(Suppl 1):S42–7.CrossRef
45.
go back to reference Cohen J. Statistical power analysis for the behavioral sciences. 2nd ed. Hillsdale: Lawrence Erlbaum Associates; 1988. Cohen J. Statistical power analysis for the behavioral sciences. 2nd ed. Hillsdale: Lawrence Erlbaum Associates; 1988.
46.
go back to reference Galle S, et al. Reducing the metabolic cost of walking with an ankle exoskeleton: interaction between actuation timing and power. J Neuroeng Rehabil. 2017;14(1):35.CrossRef Galle S, et al. Reducing the metabolic cost of walking with an ankle exoskeleton: interaction between actuation timing and power. J Neuroeng Rehabil. 2017;14(1):35.CrossRef
47.
go back to reference Mooney LM, Herr HM. Biomechanical walking mechanisms underlying the metabolic reduction caused by an autonomous exoskeleton. J Neuroeng Rehabil. 2016;13:4.CrossRef Mooney LM, Herr HM. Biomechanical walking mechanisms underlying the metabolic reduction caused by an autonomous exoskeleton. J Neuroeng Rehabil. 2016;13:4.CrossRef
48.
go back to reference Jackson RW, Collins SH. An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons. J Appl Physiol (1985). 2015;119(5):541–57.CrossRef Jackson RW, Collins SH. An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons. J Appl Physiol (1985). 2015;119(5):541–57.CrossRef
49.
go back to reference Boes MK, et al. Six-minute walk test performance in persons with multiple sclerosis while using passive or powered ankle-foot orthoses. Arch Phys Med Rehabil. 2018;99(3):484–90.CrossRef Boes MK, et al. Six-minute walk test performance in persons with multiple sclerosis while using passive or powered ankle-foot orthoses. Arch Phys Med Rehabil. 2018;99(3):484–90.CrossRef
50.
go back to reference Dollar AM, Herr H. Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art. IEEE Trans Robot. 2008;24(1):144–58.CrossRef Dollar AM, Herr H. Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art. IEEE Trans Robot. 2008;24(1):144–58.CrossRef
51.
go back to reference Norris JA, et al. Effect of augmented plantarflexion power on preferred walking speed and economy in young and older adults. Gait Posture. 2007;25(4):620–7.CrossRef Norris JA, et al. Effect of augmented plantarflexion power on preferred walking speed and economy in young and older adults. Gait Posture. 2007;25(4):620–7.CrossRef
52.
go back to reference Browning RC, et al. The effects of adding mass to the legs on the energetics and biomechanics of walking. Med Sci Sports Exerc. 2007;39(3):515–25.CrossRef Browning RC, et al. The effects of adding mass to the legs on the energetics and biomechanics of walking. Med Sci Sports Exerc. 2007;39(3):515–25.CrossRef
53.
go back to reference Neptune RR, Sasaki K. Ankle plantar flexor force production is an important determinant of the preferred walk-to-run transition speed. J Exp Biol. 2005;208(Pt 5):799–808.CrossRef Neptune RR, Sasaki K. Ankle plantar flexor force production is an important determinant of the preferred walk-to-run transition speed. J Exp Biol. 2005;208(Pt 5):799–808.CrossRef
54.
go back to reference Wanamaker AB, Andridge RR, Chaudhari AM. When to biomechanically examine a lower-limb amputee: a systematic review of accommodation times. Prosthetics Orthot Int. 2017;41(5):431–45.CrossRef Wanamaker AB, Andridge RR, Chaudhari AM. When to biomechanically examine a lower-limb amputee: a systematic review of accommodation times. Prosthetics Orthot Int. 2017;41(5):431–45.CrossRef
55.
go back to reference Russell Esposito E, et al. Does unilateral transtibial amputation lead to greater metabolic demand during walking? J Rehabil Res Dev. 2014;51(8):1287–96.CrossRef Russell Esposito E, et al. Does unilateral transtibial amputation lead to greater metabolic demand during walking? J Rehabil Res Dev. 2014;51(8):1287–96.CrossRef
Metadata
Title
Experimental comparisons of passive and powered ankle-foot orthoses in individuals with limb reconstruction
Authors
Elizabeth Russell Esposito
Kelly A. Schmidtbauer
Jason M. Wilken
Publication date
01-12-2018
Publisher
BioMed Central
Published in
Journal of NeuroEngineering and Rehabilitation / Issue 1/2018
Electronic ISSN: 1743-0003
DOI
https://doi.org/10.1186/s12984-018-0455-y

Other articles of this Issue 1/2018

Journal of NeuroEngineering and Rehabilitation 1/2018 Go to the issue