Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 4/2016

01-04-2016 | Original Article

Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods

Authors: Tobias Wissel, Patrick Stüber, Benjamin Wagner, Ralf Bruder, Achim Schweikard, Floris Ernst

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 4/2016

Login to get access

Abstract

Purpose

Patient immobilization and X-ray-based imaging provide neither a convenient nor a very accurate way to ensure low repositioning errors or to compensate for motion in cranial radiotherapy. We therefore propose an optical tracking device that exploits subcutaneous structures as landmarks in addition to merely spatial registration. To develop such head tracking algorithms, precise and robust computation of these structures is necessary. Here, we show that the tissue thickness can be predicted with high accuracy and moreover exploit local neighborhood information within the laser spot grid on the forehead to further increase this estimation accuracy.

Methods

We use statistical learning with Support Vector Regression and Gaussian Processes to learn a relationship between optical backscatter features and an MR tissue thickness ground truth. We compare different kernel functions for the data of five different subjects. The incident angle of the laser on the forehead as well as local neighborhoods is incorporated into the feature space. The latter represent the backscatter features from four neighboring laser spots.

Results

We confirm that the incident angle has a positive effect on the estimation error of the tissue thickness. The root-mean-square error falls even below 0.15 mm when adding the complete neighborhood information. This prior knowledge also leads to a smoothing effect on the reconstructed skin patch. Learning between different head poses yields similar results. The partial overlap of the point clouds makes the trade-off between novel information and increased feature space dimension obvious and hence feature selection by e.g., sequential forward selection necessary.
Literature
1.
go back to reference Fuss M, Salter BJ, Cheek D, Sadeghi A, Hevezi JM, Herman TS (2004) Repositioning accuracy of a commercially available thermoplastic mask system. Radiother Oncol 71:339–345CrossRefPubMed Fuss M, Salter BJ, Cheek D, Sadeghi A, Hevezi JM, Herman TS (2004) Repositioning accuracy of a commercially available thermoplastic mask system. Radiother Oncol 71:339–345CrossRefPubMed
2.
go back to reference Minniti G, Clarke E, Cavallo L, Osti MF, Esposito V, Cantore G, Cappabianca P, Enrici RM (2011) Fractionated stereotactic conformal radiotherapy for large benign skull base meningiomas. Radiat Oncol 6:1CrossRef Minniti G, Clarke E, Cavallo L, Osti MF, Esposito V, Cantore G, Cappabianca P, Enrici RM (2011) Fractionated stereotactic conformal radiotherapy for large benign skull base meningiomas. Radiat Oncol 6:1CrossRef
3.
go back to reference Tryggestad E, Christian M, Ford E, Kut C, Le Y, Sanguineti YG, Song DY, Kleinberg L (2011) Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT. Int J Radiat Oncol* Biol* Phys 80:281–290 Tryggestad E, Christian M, Ford E, Kut C, Le Y, Sanguineti YG, Song DY, Kleinberg L (2011) Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT. Int J Radiat Oncol* Biol* Phys 80:281–290
5.
go back to reference Peng JL, Kahler D, Li JG, Samant S, Yan G, Amdur R, Liu C (2010) Characterization of a real-time surface image-guided stereotactic positioning system. Med Phys 37:5421–5433 Peng JL, Kahler D, Li JG, Samant S, Yan G, Amdur R, Liu C (2010) Characterization of a real-time surface image-guided stereotactic positioning system. Med Phys 37:5421–5433
6.
go back to reference Cervino LI, Detorie N, Taylor M, Lawson JD, Harry T, Murphy KT, Mundt AJ, Jiang SB, Pawlicki TA (2012) Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment. Pract Radiat Oncol 2:54–62CrossRefPubMed Cervino LI, Detorie N, Taylor M, Lawson JD, Harry T, Murphy KT, Mundt AJ, Jiang SB, Pawlicki TA (2012) Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment. Pract Radiat Oncol 2:54–62CrossRefPubMed
7.
go back to reference Gopan O, Wu Q (2012) Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy. Int J Radiat Oncol* Biol* Phys 84:547–552CrossRef Gopan O, Wu Q (2012) Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy. Int J Radiat Oncol* Biol* Phys 84:547–552CrossRef
8.
go back to reference Kim Y, Li R, Na YH, Lee R, Xing L (2014) Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data. Med Phys 41:121701CrossRefPubMedPubMedCentral Kim Y, Li R, Na YH, Lee R, Xing L (2014) Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data. Med Phys 41:121701CrossRefPubMedPubMedCentral
9.
go back to reference Ernst F, Bruder R, Wissel T, Stüber P, Wagner B, Schweikard A (2013) Real time contact-free and non-invasive tracking of the human skull first light and initial validation. In: Applications of digital image processing XXXVI, proceedings of SPIE 8856, San Diego, pp 88561G-1–88561G-8 Ernst F, Bruder R, Wissel T, Stüber P, Wagner B, Schweikard A (2013) Real time contact-free and non-invasive tracking of the human skull first light and initial validation. In: Applications of digital image processing XXXVI, proceedings of SPIE 8856, San Diego, pp 88561G-1–88561G-8
10.
go back to reference Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2013) Preliminary study on optical feature detection for head tracking in radiation therapy, 13th IEEE international conference on bioInformatics and bioengineering (BIBE). IEEE, Chania, Greece, pp 1–5 Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2013) Preliminary study on optical feature detection for head tracking in radiation therapy, 13th IEEE international conference on bioInformatics and bioengineering (BIBE). IEEE, Chania, Greece, pp 1–5
11.
go back to reference Wagner B, Stüber P, Wissel T, Bruder R, Schweikard A, Ernst F (2014) Accuracy analysis for triangulation and tracking based on time-multiplexed structured light. Med Phys 41(8):82701-1-9 Wagner B, Stüber P, Wissel T, Bruder R, Schweikard A, Ernst F (2014) Accuracy analysis for triangulation and tracking based on time-multiplexed structured light. Med Phys 41(8):82701-1-9
12.
go back to reference Wissel T, Bruder R, Schweikard A, Ernst F (2013) Estimating soft tissue thickness from light-tissue interactions—a simulation study. Biomed Opt Express 4:1176–1187CrossRefPubMedPubMedCentral Wissel T, Bruder R, Schweikard A, Ernst F (2013) Estimating soft tissue thickness from light-tissue interactions—a simulation study. Biomed Opt Express 4:1176–1187CrossRefPubMedPubMedCentral
13.
go back to reference Wissel T, Stueber P, Wagner B, Dürichen R, Bruder R, Schweikard A, Ernst F (2014) Tissue thickness estimation for high precision head-tracking using a galvanometric laser scanner—a case study. In: 36th annual international conference of the IEEE engineering in medicine and biology society (EMBC‘14). IEEE, Chicago, USA, pp 3106–3109 Wissel T, Stueber P, Wagner B, Dürichen R, Bruder R, Schweikard A, Ernst F (2014) Tissue thickness estimation for high precision head-tracking using a galvanometric laser scanner—a case study. In: 36th annual international conference of the IEEE engineering in medicine and biology society (EMBC‘14). IEEE, Chicago, USA, pp 3106–3109
14.
go back to reference Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2014) Angle influence and compensation for marker-less head tracking based on laser scanners. In: Proceedings of the 28th international congress and exhibition on computer assisted radiology and surgery (CARS’14), Fukuoka, Japan, vol 9, no S1, pp 62–63 Wissel T, Stüber P, Wagner B, Bruder R, Schweikard A, Ernst F (2014) Angle influence and compensation for marker-less head tracking based on laser scanners. In: Proceedings of the 28th international congress and exhibition on computer assisted radiology and surgery (CARS’14), Fukuoka, Japan, vol 9, no S1, pp 62–63
15.
go back to reference Abdel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the symposium on close-range photogrammetry, Falls Church, VA Abdel-Aziz YI, Karara HM (1971) Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry. Proceedings of the symposium on close-range photogrammetry, Falls Church, VA
16.
go back to reference Besl PJ, Keil ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal 14:239–256CrossRef Besl PJ, Keil ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal 14:239–256CrossRef
17.
go back to reference Smola A, Schölkopf B (2004) A tutorial on Support Vector Regression. Stat Comput 14:199–222 Smola A, Schölkopf B (2004) A tutorial on Support Vector Regression. Stat Comput 14:199–222
19.
go back to reference Verleysen M, Francois D (2005) The curse of dimensionality in data mining and time series prediction. In: Proceedings of the 8th international workshop on artificial neural networks (IWANN 2005) Barcelona, Spain, pp 758–770 Verleysen M, Francois D (2005) The curse of dimensionality in data mining and time series prediction. In: Proceedings of the 8th international workshop on artificial neural networks (IWANN 2005) Barcelona, Spain, pp 758–770
Metadata
Title
Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods
Authors
Tobias Wissel
Patrick Stüber
Benjamin Wagner
Ralf Bruder
Achim Schweikard
Floris Ernst
Publication date
01-04-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 4/2016
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1246-6

Other articles of this Issue 4/2016

International Journal of Computer Assisted Radiology and Surgery 4/2016 Go to the issue