Skip to main content
Top
Published in: Clinical Neuroradiology 4/2021

01-12-2021 | Correspondence

Endovascular Revascularization with a Scoring Balloon for Carotid In-Stent Restenosis

Case Report and Literature Review

Authors: Yuki Inomata, Yoshiki Hanaoka, Jun-ichi Koyama, Yota Suzuki, Yu Fujii, Toshihiro Ogiwara, Tetsuyoshi Horiuchi

Published in: Clinical Neuroradiology | Issue 4/2021

Login to get access

Excerpt

Carotid artery stenting (CAS) is increasingly used in the treatment of carotid artery stenosis as an alternative to carotid endarterectomy for revascularization. The CAS is occasionally followed by in-stent restenosis (ISR), which is a challenging problem. Carotid ISR is associated with an increased risk of ipsilateral stroke [1] but the optimal treatment strategy for carotid ISR remains unknown [2]. …
Literature
1.
go back to reference Lal BK, Beach KW, Roubin GS, Lutsep HL, Moore WS, Malas MB, Chiu D, Gonzales NR, Burke JL, Rinaldi M, Elmore JR, Weaver FA, Narins CR, Foster M, Hodgson KJ, Shepard AD, Meschia JF, Bergelin RO, Voeks JH, Howard G, Brott TG; CREST Investigators. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial. Lancet Neurol. 2012;11:755–63.CrossRef Lal BK, Beach KW, Roubin GS, Lutsep HL, Moore WS, Malas MB, Chiu D, Gonzales NR, Burke JL, Rinaldi M, Elmore JR, Weaver FA, Narins CR, Foster M, Hodgson KJ, Shepard AD, Meschia JF, Bergelin RO, Voeks JH, Howard G, Brott TG; CREST Investigators. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial. Lancet Neurol. 2012;11:755–63.CrossRef
2.
go back to reference Pourier VE, de Borst GJ. Technical options for treatment of in-stent restenosis after carotid artery stenting. J Vasc Surg. 2016;64:1486–96.CrossRef Pourier VE, de Borst GJ. Technical options for treatment of in-stent restenosis after carotid artery stenting. J Vasc Surg. 2016;64:1486–96.CrossRef
3.
go back to reference Scheinert D, Peeters P, Bosiers M, O’Sullivan G, Sultan S, Gershony G. Results of the multicenter first-in-man study of a novel scoring balloon catheter for the treatment of infra-popliteal peripheral arterial disease. Catheter Cardiovasc Interv. 2007;70:1034–9.CrossRef Scheinert D, Peeters P, Bosiers M, O’Sullivan G, Sultan S, Gershony G. Results of the multicenter first-in-man study of a novel scoring balloon catheter for the treatment of infra-popliteal peripheral arterial disease. Catheter Cardiovasc Interv. 2007;70:1034–9.CrossRef
4.
go back to reference Ashida K, Hayase T, Shinmura T. Efficacy of lacrosse NSE using the “leopard-crawl” technique on severely calcified lesions. J Invasive Cardiol. 2013;25:555–64.PubMed Ashida K, Hayase T, Shinmura T. Efficacy of lacrosse NSE using the “leopard-crawl” technique on severely calcified lesions. J Invasive Cardiol. 2013;25:555–64.PubMed
5.
go back to reference Taguchi I, Kageyama M, Kanaya T, Abe S, Node K, Inoue T. Clinical significance of non-slip element balloon angioplasty for patients of coronary artery disease: a preliminary report. J Cardiol. 2014;63:19–23.CrossRef Taguchi I, Kageyama M, Kanaya T, Abe S, Node K, Inoue T. Clinical significance of non-slip element balloon angioplasty for patients of coronary artery disease: a preliminary report. J Cardiol. 2014;63:19–23.CrossRef
6.
go back to reference Aoki J, Nakazawa G, Ando K, Nakamura S, Tobaru T, Sakurada M, Okada H, Hibi K, Zen K, Habara S, Fujii K, Habara M, Ako J, Asano T, Ozaki S, Fusazaki T, Kozuma K; ELEGANT Investigators. Effect of combination of non-slip element balloon and drug-coating balloon for in-stent restenosis lesions (ELEGANT study). J Cardiol. 2019;74:436–42.CrossRef Aoki J, Nakazawa G, Ando K, Nakamura S, Tobaru T, Sakurada M, Okada H, Hibi K, Zen K, Habara S, Fujii K, Habara M, Ako J, Asano T, Ozaki S, Fusazaki T, Kozuma K; ELEGANT Investigators. Effect of combination of non-slip element balloon and drug-coating balloon for in-stent restenosis lesions (ELEGANT study). J Cardiol. 2019;74:436–42.CrossRef
7.
go back to reference de Ribamar Costa J Jr, Mintz GS, Carlier SG, Mehran R, Teirstein P, Sano K, Liu X, Lui J, Na Y, Castellanos C, Biro S, Dani L, Rinker J, Moussa I, Dangas G, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Nonrandomized comparison of coronary stenting under intravascular ultrasound guidance of direct stenting without predilation versus conventional predilation with a semi-compliant balloon versus predilation with a new scoring balloon. Am J Cardiol. 2007;100:812–7.CrossRef de Ribamar Costa J Jr, Mintz GS, Carlier SG, Mehran R, Teirstein P, Sano K, Liu X, Lui J, Na Y, Castellanos C, Biro S, Dani L, Rinker J, Moussa I, Dangas G, Lansky AJ, Kreps EM, Collins M, Stone GW, Moses JW, Leon MB. Nonrandomized comparison of coronary stenting under intravascular ultrasound guidance of direct stenting without predilation versus conventional predilation with a semi-compliant balloon versus predilation with a new scoring balloon. Am J Cardiol. 2007;100:812–7.CrossRef
8.
go back to reference Sorkin GC, Dumont TM, Eller JL, Mokin M, Hopkins LN, Snyder KV, Siddiqui AH, Levy EI. Instent restenosis after carotid stenting: treatment using an off-label cardiac scoring balloon. J Vasc Interv Neurol. 2014;7:29–34.PubMedPubMedCentral Sorkin GC, Dumont TM, Eller JL, Mokin M, Hopkins LN, Snyder KV, Siddiqui AH, Levy EI. Instent restenosis after carotid stenting: treatment using an off-label cardiac scoring balloon. J Vasc Interv Neurol. 2014;7:29–34.PubMedPubMedCentral
9.
go back to reference Hanaoka Y, Koyama JI, Ogiwara T, Miyaoka Y, Fujii Y, Nakamura T, Horiuchi T, Hongo K. Usefulness of a Novel Technique to Make Up for a Deficiency in Transradial Neurointervention with a 6Fr Simmonds Guiding Sheath: Original Experience with the Subclavian Artery Anchoring Technique. World Neurosurg. 2019;131:e362–70.CrossRef Hanaoka Y, Koyama JI, Ogiwara T, Miyaoka Y, Fujii Y, Nakamura T, Horiuchi T, Hongo K. Usefulness of a Novel Technique to Make Up for a Deficiency in Transradial Neurointervention with a 6Fr Simmonds Guiding Sheath: Original Experience with the Subclavian Artery Anchoring Technique. World Neurosurg. 2019;131:e362–70.CrossRef
10.
go back to reference Hanaoka Y, Koyama JI, Yamazaki D, Miyaoka Y, Fujii Y, Nakamura T, Ogiwara T, Ito K, Horiuchi T. Transradial Approach as the Primary Vascular Access with a 6-Fr Simmons Guiding Sheath for Anterior Circulation Interventions: A Single-Center Case Series of 130 Consecutive Patients. World Neurosurg. 2020;138:e597–606.CrossRef Hanaoka Y, Koyama JI, Yamazaki D, Miyaoka Y, Fujii Y, Nakamura T, Ogiwara T, Ito K, Horiuchi T. Transradial Approach as the Primary Vascular Access with a 6-Fr Simmons Guiding Sheath for Anterior Circulation Interventions: A Single-Center Case Series of 130 Consecutive Patients. World Neurosurg. 2020;138:e597–606.CrossRef
11.
go back to reference Hanaoka Y, Koyama JI, Ogiwara T, Fujii Y, Ito K, Horiuchi T. Feasibility and Safety of Radial-First Approach with a Radial-Specific Neurointerventional Guiding Sheath for Intracranial Aneurysm Coiling in the Anterior Circulation. World Neurosurg. 2020;142:e297–306.CrossRef Hanaoka Y, Koyama JI, Ogiwara T, Fujii Y, Ito K, Horiuchi T. Feasibility and Safety of Radial-First Approach with a Radial-Specific Neurointerventional Guiding Sheath for Intracranial Aneurysm Coiling in the Anterior Circulation. World Neurosurg. 2020;142:e297–306.CrossRef
12.
go back to reference Alfonso F, Byrne RA, Rivero F, Kastrati A. Current treatment of in-stent restenosis. J Am Coll Cardiol. 2014;63:2659–73.CrossRef Alfonso F, Byrne RA, Rivero F, Kastrati A. Current treatment of in-stent restenosis. J Am Coll Cardiol. 2014;63:2659–73.CrossRef
13.
go back to reference Kearney M, Pieczek A, Haley L, Losordo DW, Andres V, Schainfeld R, Rosenfield K, Isner JM. Histopathology of in-stent restenosis in patients with peripheral artery disease. Circulation. 1997;95:1998–2002.CrossRef Kearney M, Pieczek A, Haley L, Losordo DW, Andres V, Schainfeld R, Rosenfield K, Isner JM. Histopathology of in-stent restenosis in patients with peripheral artery disease. Circulation. 1997;95:1998–2002.CrossRef
14.
go back to reference Kufner S, Joner M, Schneider S, Tölg R, Zrenner B, Repp J, Starkmann A, Xhepa E, Ibrahim T, Cassese S, Fusaro M, Ott I, Hengstenberg C, Schunkert H, Abdel-Wahab M, Laugwitz KL, Kastrati A, Byrne RA; ISAR-DESIRE 4 Investigators. Neointimal Modification With Scoring Balloon and Efficacy of Drug-Coated Balloon Therapy in Patients With Restenosis in Drug-Eluting Coronary Stents: A Randomized Controlled Trial. JACC Cardiovasc Interv. 2017;10:1332–40.CrossRef Kufner S, Joner M, Schneider S, Tölg R, Zrenner B, Repp J, Starkmann A, Xhepa E, Ibrahim T, Cassese S, Fusaro M, Ott I, Hengstenberg C, Schunkert H, Abdel-Wahab M, Laugwitz KL, Kastrati A, Byrne RA; ISAR-DESIRE 4 Investigators. Neointimal Modification With Scoring Balloon and Efficacy of Drug-Coated Balloon Therapy in Patients With Restenosis in Drug-Eluting Coronary Stents: A Randomized Controlled Trial. JACC Cardiovasc Interv. 2017;10:1332–40.CrossRef
15.
go back to reference Takano M, Yamamoto M, Murakami D, Takano H, Asai K, Yasutake M, Seino Y, Mizuno K. Optical coherence tomography after new scoring balloon angioplasty for in-stent restenosis and de novo coronary lesions. Int J Cardiol. 2010;141:e51–3.CrossRef Takano M, Yamamoto M, Murakami D, Takano H, Asai K, Yasutake M, Seino Y, Mizuno K. Optical coherence tomography after new scoring balloon angioplasty for in-stent restenosis and de novo coronary lesions. Int J Cardiol. 2010;141:e51–3.CrossRef
16.
go back to reference Naeem AH, Al-Rumaihi G, Namavarian A, Sharma M, Boulton M. Balloon Angioplasty for In-Stent Restenosis Resulting in Carotid Stent Fracture: Literature Review of Stent-in-Stent Technique as a Viable Therapeutic Option. World Neurosurg. 2017;101:818.e1–6.CrossRef Naeem AH, Al-Rumaihi G, Namavarian A, Sharma M, Boulton M. Balloon Angioplasty for In-Stent Restenosis Resulting in Carotid Stent Fracture: Literature Review of Stent-in-Stent Technique as a Viable Therapeutic Option. World Neurosurg. 2017;101:818.e1–6.CrossRef
17.
go back to reference Sato D, Ogawa S, Fujimoto S, Suzuki T, Ueda M, Ota T. Carotid endarterectomy for intractable repetitive stenosis following carotid artery stenting. World Neurosurg. 2021;145:311–4.CrossRef Sato D, Ogawa S, Fujimoto S, Suzuki T, Ueda M, Ota T. Carotid endarterectomy for intractable repetitive stenosis following carotid artery stenting. World Neurosurg. 2021;145:311–4.CrossRef
18.
go back to reference Willfort-Ehringer A, Ahmadi R, Gschwandtner ME, Haumer A, Heinz G, Lang W, Ehringer H. Healing of carotid stents: a prospective duplex ultrasound study. J Endovasc Ther. 2003;10:636–42.CrossRef Willfort-Ehringer A, Ahmadi R, Gschwandtner ME, Haumer A, Heinz G, Lang W, Ehringer H. Healing of carotid stents: a prospective duplex ultrasound study. J Endovasc Ther. 2003;10:636–42.CrossRef
19.
go back to reference Toma N, Matsushima S, Murao K, Kawaguchi K, Imanaka-Yoshida K, Yoshida T, Taki W. Histopathological findings in a human carotid artery after stent implantation. Case report. J Neurosurg. 2003;98:199–204.CrossRef Toma N, Matsushima S, Murao K, Kawaguchi K, Imanaka-Yoshida K, Yoshida T, Taki W. Histopathological findings in a human carotid artery after stent implantation. Case report. J Neurosurg. 2003;98:199–204.CrossRef
20.
go back to reference Willfort-Ehringer A, Ahmadi R, Gruber D, Gschwandtner ME, Haumer A, Haumer M, Ehringer H. Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg. 2004;39:728–34.CrossRef Willfort-Ehringer A, Ahmadi R, Gruber D, Gschwandtner ME, Haumer A, Haumer M, Ehringer H. Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg. 2004;39:728–34.CrossRef
21.
go back to reference Pizzolato R, Hirsch JA, Romero JM. Imaging challenges of carotid artery in-stent restenosis. J Neurointerv Surg. 2014;6:32–41.CrossRef Pizzolato R, Hirsch JA, Romero JM. Imaging challenges of carotid artery in-stent restenosis. J Neurointerv Surg. 2014;6:32–41.CrossRef
22.
go back to reference Lal BK, Kaperonis EA, Cuadra S, Kapadia I, Hobson RW 2nd. Patterns of in-stent restenosis after carotid artery stenting: classification and implications for long-term outcome. J Vasc Surg. 2007;46:833–40.CrossRef Lal BK, Kaperonis EA, Cuadra S, Kapadia I, Hobson RW 2nd. Patterns of in-stent restenosis after carotid artery stenting: classification and implications for long-term outcome. J Vasc Surg. 2007;46:833–40.CrossRef
23.
go back to reference Tübler T, Schlüter M, Dirsch O, Sievert H, Bösenberg I, Grube E, Waigand J, Schofer J. Balloon-protected carotid artery stenting: relationship of periprocedural neurological complications with the size of particulate debris. Circulation. 2001;104:2791–6.CrossRef Tübler T, Schlüter M, Dirsch O, Sievert H, Bösenberg I, Grube E, Waigand J, Schofer J. Balloon-protected carotid artery stenting: relationship of periprocedural neurological complications with the size of particulate debris. Circulation. 2001;104:2791–6.CrossRef
24.
go back to reference Piazza M, Squizzato F, Chincarini C, Fedrigo M, Castellani C, Angelini A, Grego F, Antonello M. Quantitative analysis and predictors of embolic filter debris load during carotid artery stenting in asymptomatic patients. J Vasc Surg. 2018;68:109–17.CrossRef Piazza M, Squizzato F, Chincarini C, Fedrigo M, Castellani C, Angelini A, Grego F, Antonello M. Quantitative analysis and predictors of embolic filter debris load during carotid artery stenting in asymptomatic patients. J Vasc Surg. 2018;68:109–17.CrossRef
Metadata
Title
Endovascular Revascularization with a Scoring Balloon for Carotid In-Stent Restenosis
Case Report and Literature Review
Authors
Yuki Inomata
Yoshiki Hanaoka
Jun-ichi Koyama
Yota Suzuki
Yu Fujii
Toshihiro Ogiwara
Tetsuyoshi Horiuchi
Publication date
01-12-2021
Publisher
Springer Berlin Heidelberg
Published in
Clinical Neuroradiology / Issue 4/2021
Print ISSN: 1869-1439
Electronic ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-021-01016-2

Other articles of this Issue 4/2021

Clinical Neuroradiology 4/2021 Go to the issue