Skip to main content
Top
Published in: Journal of Artificial Organs 4/2018

01-12-2018 | Original Article

Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery

Authors: Teppei Toya, Tomoyuki Fujita, Satuki Fukushima, Yusuke Shimahara, Yuta Kume, Kizuku Yamashita, Yorihiko Matsumoto, Naonori Kawamoto, Junjiro Kobayashi

Published in: Journal of Artificial Organs | Issue 4/2018

Login to get access

Abstract

Lower limb ischemia with an occlusive cannula is a potential complication of minimally invasive cardiac surgery (MICS). We evaluated intraoperative local oxygen supply–demand balance by monitoring regional saturation of oxygen (rSO2) using near-infrared spectroscopy (NIRS), and analyzed the correlation between cannula size and fluctuation range of rSO2. Fifty-four patients undergoing MICS surgery using femoral artery cannulation from April 2015 to August 2016 were enrolled. The rSO2 of both the cannulated and uncannulated lower limbs were measured using NIRS. The association between the decline of rSO2 from baseline (delta-rSO2) and the ratio of the cannula diameter to the femoral artery diameter (Cd/FAd) was analyzed. Of the 54 patients, 16 (30%) (Group 1) showed values over 0.65 for Cd/FAd, and the remaining 38 (70%) (Group 2) showed values under 0.65. No patient developed postoperative lower limb ischemia. No patient was treated with an ipsilateral distal perfusion cannula. There were significant differences between Group 1 and Group 2 in the decrease of rSO2 at the point of cannulation on the cannulated limb. In the lower limb on the cannulated side, delta-rSO2 showed a significant decrease in Group 1 compared to Group 2 (Group 1 vs Group 2: 19.9 vs 11.0%; p < 0.001). Delta-rSO2 was significantly correlated with body surface aera (BSA), but not with gender or age. Decreasing rSO2 correlates with the Cd/FAd index. Low BSA, Cd/Fad > 0.65 is considered as the risk factor for decline of rSO2 in cannulated limb in MICS.
Appendix
Available only for authorised users
Literature
1.
go back to reference Glower DD, Landolfo KP, Clements F, et al. Mitral valve operation via port-access versus median sternotomy. Eur J Cardiothorac Surg. 1998;14:143–7.CrossRef Glower DD, Landolfo KP, Clements F, et al. Mitral valve operation via port-access versus median sternotomy. Eur J Cardiothorac Surg. 1998;14:143–7.CrossRef
2.
go back to reference Grossi EA, Loulmet DF, Schwartz CF, et al. Evolution of operative techniques and perfusion strategies for minimally invasive mitral valve repair. J Thorac Cardiovasc Surg. 2012;143:68–70.CrossRef Grossi EA, Loulmet DF, Schwartz CF, et al. Evolution of operative techniques and perfusion strategies for minimally invasive mitral valve repair. J Thorac Cardiovasc Surg. 2012;143:68–70.CrossRef
3.
go back to reference Gander JW, Fisher JC, Reichstein AR, et al. Limb ischemia after common femoral artery cannulation for venoarterial extracorporeal membrane oxygenation: an unresolved problem. J Pediatr Surg. 2010;45:2136–40.CrossRef Gander JW, Fisher JC, Reichstein AR, et al. Limb ischemia after common femoral artery cannulation for venoarterial extracorporeal membrane oxygenation: an unresolved problem. J Pediatr Surg. 2010;45:2136–40.CrossRef
4.
go back to reference Bisdas T, Beutel G, Wamecke G, et al. Vascular complications in patients undergoing femoral cannulation for extracorporeal membrane oxygenation support. Ann Thorac Surg. 2011;92:626–31.CrossRef Bisdas T, Beutel G, Wamecke G, et al. Vascular complications in patients undergoing femoral cannulation for extracorporeal membrane oxygenation support. Ann Thorac Surg. 2011;92:626–31.CrossRef
5.
go back to reference Gates JD, Bichell DP, Rizzo RJ, et al. Thigh ischemia complicating femoral vessel cannulation for cardiopulmonary bypass. Ann Thorac Surg. 1996;61:730–3.CrossRef Gates JD, Bichell DP, Rizzo RJ, et al. Thigh ischemia complicating femoral vessel cannulation for cardiopulmonary bypass. Ann Thorac Surg. 1996;61:730–3.CrossRef
6.
go back to reference Madershahian N, Nagib R, Wippermann J, et al. A simple technique of distal limb perfusion during prolonged femorofemoral cannulation. J Card Surg. 2006;21:168–9.CrossRef Madershahian N, Nagib R, Wippermann J, et al. A simple technique of distal limb perfusion during prolonged femorofemoral cannulation. J Card Surg. 2006;21:168–9.CrossRef
7.
go back to reference Ceviz M, Ozyazicioglu A, Kocak H. The prevention of leg ischemia during femoral cannulation. Ann Thorac Surg. 1999;67:1217.CrossRef Ceviz M, Ozyazicioglu A, Kocak H. The prevention of leg ischemia during femoral cannulation. Ann Thorac Surg. 1999;67:1217.CrossRef
8.
go back to reference Riley JB, Hardin SB, Winn BA, et al. In vitro comparison of cavoatrial (dual stage) cannulae for use during cardiopulmonary bypass. Perfusion. 1986;1:197–204.CrossRef Riley JB, Hardin SB, Winn BA, et al. In vitro comparison of cavoatrial (dual stage) cannulae for use during cardiopulmonary bypass. Perfusion. 1986;1:197–204.CrossRef
9.
go back to reference Delius RF, Montoya JP, Merz SJ, et al. A new method for describing the performance of cardiac surgery cannulas. Ann Thorac Surg. 1992;33:278–81.CrossRef Delius RF, Montoya JP, Merz SJ, et al. A new method for describing the performance of cardiac surgery cannulas. Ann Thorac Surg. 1992;33:278–81.CrossRef
10.
go back to reference Kasirajan V, Simmons I, King J, et al. Technique to prevent limb ischemia during peripheral cannulation for extracorporeal membrane oxygenation. Perfusion. 2002;17:427–8.CrossRef Kasirajan V, Simmons I, King J, et al. Technique to prevent limb ischemia during peripheral cannulation for extracorporeal membrane oxygenation. Perfusion. 2002;17:427–8.CrossRef
11.
go back to reference Formica F, Avalli L, Colagrande L, et al. Extracorporeal membrane oxygenation to support adult patients with cardiac failure: predictive factors of 30-day mortality. Interact Cardiovasc Thorac Surg. 2010;10:721–6.CrossRef Formica F, Avalli L, Colagrande L, et al. Extracorporeal membrane oxygenation to support adult patients with cardiac failure: predictive factors of 30-day mortality. Interact Cardiovasc Thorac Surg. 2010;10:721–6.CrossRef
12.
go back to reference Greenberg S, Murphy G, Shear T, et al. Extracranial contamination in the INVOS 5100C versus the FORE-SIGHT ELITE cerebral oximeter: a prospective observational crossover study in volunteers. Can J Anesth/J Can Anesth. 2016;63:512.CrossRef Greenberg S, Murphy G, Shear T, et al. Extracranial contamination in the INVOS 5100C versus the FORE-SIGHT ELITE cerebral oximeter: a prospective observational crossover study in volunteers. Can J Anesth/J Can Anesth. 2016;63:512.CrossRef
13.
go back to reference Faber DJ, Mik EG, et al. Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography. Opt Lett. 2005;30:1015–7.CrossRef Faber DJ, Mik EG, et al. Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography. Opt Lett. 2005;30:1015–7.CrossRef
14.
go back to reference Scholkmann F, Kleiser S, Metz AJ, et al. A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology. Neuroimage. 2014;15:6–27.CrossRef Scholkmann F, Kleiser S, Metz AJ, et al. A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology. Neuroimage. 2014;15:6–27.CrossRef
15.
go back to reference Fantini S, Hueber D, Franceschini MA, et al. Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy. Phys Med Biol. 1999;44:1543–63.CrossRef Fantini S, Hueber D, Franceschini MA, et al. Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy. Phys Med Biol. 1999;44:1543–63.CrossRef
16.
go back to reference Delpy DT, Cope M. Quantification in tissue near-infrared spectroscopy. Philos Trans R Soc Lond B Biol Sci. 1997;352:649–59.CrossRef Delpy DT, Cope M. Quantification in tissue near-infrared spectroscopy. Philos Trans R Soc Lond B Biol Sci. 1997;352:649–59.CrossRef
17.
go back to reference Scholkmann F, Wolf M. General equation for the differential pathlength factor of the frontal human head depending on wavelength and age. J Biomed Opt. 2013;18:105004.CrossRef Scholkmann F, Wolf M. General equation for the differential pathlength factor of the frontal human head depending on wavelength and age. J Biomed Opt. 2013;18:105004.CrossRef
18.
go back to reference Gao L, Elwell CE, Kohl-Bareis M, et al. Effects of assuming constant optical scattering on haemoglobin concentration measurements using NIRS during a Valsalva Manoeuvre. Adv Exp Med Biol. 2011;701:15–20.CrossRef Gao L, Elwell CE, Kohl-Bareis M, et al. Effects of assuming constant optical scattering on haemoglobin concentration measurements using NIRS during a Valsalva Manoeuvre. Adv Exp Med Biol. 2011;701:15–20.CrossRef
19.
go back to reference Yoshitani K, Kawaguchi M, Okuno T, et al. Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass. Anesth Analg. 2007;104:341–6.CrossRef Yoshitani K, Kawaguchi M, Okuno T, et al. Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass. Anesth Analg. 2007;104:341–6.CrossRef
20.
go back to reference Yoshitani K, Kuwajima K, Irie T, et al. Clinical validity of cerebral oxygen saturation measured by time-resolved spectroscopy during carotid endarterectomy. J Neurosurg Anesthesiol. 2013;25:248–53.CrossRef Yoshitani K, Kuwajima K, Irie T, et al. Clinical validity of cerebral oxygen saturation measured by time-resolved spectroscopy during carotid endarterectomy. J Neurosurg Anesthesiol. 2013;25:248–53.CrossRef
Metadata
Title
Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery
Authors
Teppei Toya
Tomoyuki Fujita
Satuki Fukushima
Yusuke Shimahara
Yuta Kume
Kizuku Yamashita
Yorihiko Matsumoto
Naonori Kawamoto
Junjiro Kobayashi
Publication date
01-12-2018
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 4/2018
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1057-y

Other articles of this Issue 4/2018

Journal of Artificial Organs 4/2018 Go to the issue