Cerebral oximetry for cardiac surgery: a preoperative comparison of device characteristics and pitfalls in interpretation

Authors: Kensuke Kobayashi, Tadashi Kitamura, Satoshi Kohira, Shinzo Torii, Toshiaki Mishima, Hirotoki Ohkubo, Yuki Tanaka, Akihiro Sasahara, Takuma Fukunishi, Yuki Ohtomo, Rihito Horikoshi, Yuta Murai, Kagami Miyaji

Published in: Journal of Artificial Organs | Issue 4/2018

Login to get access

Abstract

Regional cerebral oximetry using near-infrared spectroscopy devices is commonly used for detecting cerebral ischemia during cardiopulmonary bypass, and aim to avoid poor cerebral perfusion which may result in perioperative neurological impairment. Today, several devices that can detect cerebral ischemia are commercially available. Although these devices operate on the same measurement principles, their algorithms for detecting and calculating cerebral ischemia are different and no criteria for directly comparing values measured by such different devices exist. From January 2017 to August 2017, 80 adult cardiovascular surgery patients were enrolled in the prospective study. In each patient, preoperative regional cerebral oxygen saturation values were measured by two different devices and their correlations with various preoperative factors were evaluated. Regional cerebral oxygen saturation levels were significantly higher for values of FORE-SIGHT ELITE (CAS Medical Systems, Branford, CT, USA) (F value) than those of the INVOS 5100C (Medtronic, Minneapolis, MN, USA) (I value). Scalp–cortex distance, hemoglobin concentration, and the presence or absence of hemodialysis showed significant correlations with ratios of measured values specific to each device (F/I). An appropriate device should be selected according to preoperative patient characteristics, and factors influencing regional cerebral oxygen saturation values should be considered to ensure the correct interpretation of measured values. This research was conducted with the approval of the ethics committee of our university (approval number: B16–96).
Literature
1.
go back to reference Tsai HI, Chung PC, Lee CW, Yu HP. Cerebral perfusion monitoring in acute care surgery: current and perspective use. Expert Rev Med Devices. 2016;13:865–75.CrossRefPubMed Tsai HI, Chung PC, Lee CW, Yu HP. Cerebral perfusion monitoring in acute care surgery: current and perspective use. Expert Rev Med Devices. 2016;13:865–75.CrossRefPubMed
2.
go back to reference Denault A, Deschamps A, Murkin JM. A proposed algorithm for the intraoperative use of cerebral near-infrared spectroscopy. Semin Cardiothorac Vasc Anesth. 2007;11:274–81.CrossRefPubMed Denault A, Deschamps A, Murkin JM. A proposed algorithm for the intraoperative use of cerebral near-infrared spectroscopy. Semin Cardiothorac Vasc Anesth. 2007;11:274–81.CrossRefPubMed
3.
go back to reference Colak Z, Borojevic M, Bogovic A, Ivancan V, Biocina B, Majeric-Kogler V. Influence of intraoperative cerebral oximetry monitoring on neurocognitive function after coronary artery bypass surgery: a randomized, prospective study. Eur J Cardiothorac Surg. 2015;47:447–54.CrossRefPubMed Colak Z, Borojevic M, Bogovic A, Ivancan V, Biocina B, Majeric-Kogler V. Influence of intraoperative cerebral oximetry monitoring on neurocognitive function after coronary artery bypass surgery: a randomized, prospective study. Eur J Cardiothorac Surg. 2015;47:447–54.CrossRefPubMed
4.
go back to reference Gottlieb EA, Fraser CD Jr, Andropoulos DB, Diaz LK. Bilateral monitoring of cerebral oxygen saturation results in recognition of aortic cannula malposition during pediatric congenital heart surgery. Paediatr Anaesth. 2006;16:787–9.CrossRefPubMed Gottlieb EA, Fraser CD Jr, Andropoulos DB, Diaz LK. Bilateral monitoring of cerebral oxygen saturation results in recognition of aortic cannula malposition during pediatric congenital heart surgery. Paediatr Anaesth. 2006;16:787–9.CrossRefPubMed
5.
go back to reference Chan SK, Underwood MJ, Ho AM, So JM, Ho AK, Wan IY, Wong RH. Cannula malposition during antegrade cerebral perfusion for aortic surgery: role of cerebral oximetry. Can J Anaesth. 2014;61:736–40.CrossRefPubMed Chan SK, Underwood MJ, Ho AM, So JM, Ho AK, Wan IY, Wong RH. Cannula malposition during antegrade cerebral perfusion for aortic surgery: role of cerebral oximetry. Can J Anaesth. 2014;61:736–40.CrossRefPubMed
6.
go back to reference Kobayashi K, Kitamura T, Kohira S, Torii S, Horai T, Hirata M, Mishima T, Sughimoto K, Ohkubo H, Irisawa Y, Matsushiro T, Hayashi H, Miyata Y, Tsuchida Y, Ohtomo N, Miyaji K. Factors associated with a low initial cerebral oxygen saturation value in patients undergoing cardiac surgery. J Artif Organs. 2017;20:110–6.CrossRefPubMed Kobayashi K, Kitamura T, Kohira S, Torii S, Horai T, Hirata M, Mishima T, Sughimoto K, Ohkubo H, Irisawa Y, Matsushiro T, Hayashi H, Miyata Y, Tsuchida Y, Ohtomo N, Miyaji K. Factors associated with a low initial cerebral oxygen saturation value in patients undergoing cardiac surgery. J Artif Organs. 2017;20:110–6.CrossRefPubMed
7.
go back to reference Gregory AJ, Hatem MA, Yee K, Grocott HP. Optimal placement of cerebral oximeter monitors to avoid the frontal sinus as determined by computed tomography. J Cardiothorac Vasc Anesth. 2016;30:127–33.CrossRefPubMed Gregory AJ, Hatem MA, Yee K, Grocott HP. Optimal placement of cerebral oximeter monitors to avoid the frontal sinus as determined by computed tomography. J Cardiothorac Vasc Anesth. 2016;30:127–33.CrossRefPubMed
8.
go back to reference Food, Administration D, Center for Drug Evaluation and Research (CDER). Guidance for industry: bioavailability and bioequivalence studies for orally administered drug products—general considerations. Washington, DC: FDA; 2003. Food, Administration D, Center for Drug Evaluation and Research (CDER). Guidance for industry: bioavailability and bioequivalence studies for orally administered drug products—general considerations. Washington, DC: FDA; 2003.
9.
go back to reference Arrowsmith JE, Grocott HP, Reves JG, Newman MF. Central nervous system complications of cardiac surgery. Br J Anaesth. 2000;84:378–93.CrossRefPubMed Arrowsmith JE, Grocott HP, Reves JG, Newman MF. Central nervous system complications of cardiac surgery. Br J Anaesth. 2000;84:378–93.CrossRefPubMed
10.
go back to reference Jöbsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science. 1977;198:1264–7.CrossRefPubMed Jöbsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science. 1977;198:1264–7.CrossRefPubMed
11.
go back to reference Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.CrossRefPubMedPubMedCentral Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.CrossRefPubMedPubMedCentral
12.
go back to reference Heringlake M, Garbers C, Käbler JH, Anderson I, Heinze H, Schön J, Berger KU, Dibbelt L, Sievers HH, Hanke T. Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery. Anesthesiology. 2011;114:58–69.CrossRefPubMed Heringlake M, Garbers C, Käbler JH, Anderson I, Heinze H, Schön J, Berger KU, Dibbelt L, Sievers HH, Hanke T. Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery. Anesthesiology. 2011;114:58–69.CrossRefPubMed
13.
go back to reference Slater JP, Guarino T, Stack J, Vinod K, Bustami RT, Brown JM 3rd, Rodriguez AL, Magovern CJ, Zaubler T, Freundlich K, Parr GV. Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg. 2009;87:36–44.CrossRefPubMed Slater JP, Guarino T, Stack J, Vinod K, Bustami RT, Brown JM 3rd, Rodriguez AL, Magovern CJ, Zaubler T, Freundlich K, Parr GV. Cerebral oxygen desaturation predicts cognitive decline and longer hospital stay after cardiac surgery. Ann Thorac Surg. 2009;87:36–44.CrossRefPubMed
14.
go back to reference Goldman S, Sutter F, Ferdinand F, Trace C. Optimizing intraoperative cerebral oxygen delivery using noninvasive cerebral oximetry decreases the incidence of stroke for cardiac surgical patients. Heart Surg Forum. 2004;7:E376–81.CrossRef Goldman S, Sutter F, Ferdinand F, Trace C. Optimizing intraoperative cerebral oxygen delivery using noninvasive cerebral oximetry decreases the incidence of stroke for cardiac surgical patients. Heart Surg Forum. 2004;7:E376–81.CrossRef
15.
go back to reference Murkin JM, Adams SJ, Novick RJ, Quantz M, Bainbridge D, Iglesias I, Cleland A, Schaefer B, Irwin B, Fox S. Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study. Anesth Analg. 2007;104:51–8.CrossRefPubMed Murkin JM, Adams SJ, Novick RJ, Quantz M, Bainbridge D, Iglesias I, Cleland A, Schaefer B, Irwin B, Fox S. Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study. Anesth Analg. 2007;104:51–8.CrossRefPubMed
16.
go back to reference Bickler PE, Feiner JR, Rollins MD. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Anesth Analg. 2013;117:813–23.CrossRefPubMed Bickler PE, Feiner JR, Rollins MD. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Anesth Analg. 2013;117:813–23.CrossRefPubMed
17.
go back to reference Edmonds HL Jr, Ganzel BL, Austin EH 3rd. Cerebral oximetry for cardiac and vascular surgery. Semin Cardiothorac Vasc Anesth. 2004;8:147–66.CrossRefPubMed Edmonds HL Jr, Ganzel BL, Austin EH 3rd. Cerebral oximetry for cardiac and vascular surgery. Semin Cardiothorac Vasc Anesth. 2004;8:147–66.CrossRefPubMed
18.
go back to reference Yoshitani K, Kawaguchi M, Miura N, Okuno T, Kanoda T, Ohnishi Y, Kuro M. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology 2007;106:458–62.CrossRefPubMed Yoshitani K, Kawaguchi M, Miura N, Okuno T, Kanoda T, Ohnishi Y, Kuro M. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology 2007;106:458–62.CrossRefPubMed
19.
go back to reference Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.CrossRefPubMed Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.CrossRefPubMed
20.
go back to reference Okada E, Delpy DT. Near-infrared light propagation in an adult head model. II. effect of superficial tissue thickness on the sensitivity of the near-infrared spectroscopy signal. Appl Opt. 2003;42:2915–22.CrossRefPubMed Okada E, Delpy DT. Near-infrared light propagation in an adult head model. II. effect of superficial tissue thickness on the sensitivity of the near-infrared spectroscopy signal. Appl Opt. 2003;42:2915–22.CrossRefPubMed
21.
go back to reference Yoshitani K, Kawaguchi M, Okuno T, Kanoda T, Ohnishi Y, Kuro M, Nishizawa M. Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass. Anesth Analg. 2007;104:341–6.CrossRefPubMed Yoshitani K, Kawaguchi M, Okuno T, Kanoda T, Ohnishi Y, Kuro M, Nishizawa M. Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass. Anesth Analg. 2007;104:341–6.CrossRefPubMed
22.
go back to reference Jiang XL, Wen JQ, Zhang LJ, Zheng G, Li X, Zhang Z, Liu Y, Zheng LJ, Wu L, Chen HJ, Kong X, Luo S, Lu GM, Ji XM, Zhang ZJ. Cerebral blood flow changes in hemodialysis and peritoneal dialysis patients: an arterial-spin labeling MR imaging. Metab Brain Dis. 2016;31:929–36.CrossRefPubMed Jiang XL, Wen JQ, Zhang LJ, Zheng G, Li X, Zhang Z, Liu Y, Zheng LJ, Wu L, Chen HJ, Kong X, Luo S, Lu GM, Ji XM, Zhang ZJ. Cerebral blood flow changes in hemodialysis and peritoneal dialysis patients: an arterial-spin labeling MR imaging. Metab Brain Dis. 2016;31:929–36.CrossRefPubMed
24.
go back to reference Fischer GW, Silvay G. Cerebral oximetry in cardiac and major vascular surgery. HSR Proc Intensive Care Cardiovasc Anesth. 2010;2:249–56.PubMedPubMedCentral Fischer GW, Silvay G. Cerebral oximetry in cardiac and major vascular surgery. HSR Proc Intensive Care Cardiovasc Anesth. 2010;2:249–56.PubMedPubMedCentral
25.
go back to reference Fischer GW, Lin HM, Krol M, Galati MF, Di Luozzo G, Griepp RB, Reich DL. Noninvasive cerebral oxygenation may predict outcome in patients undergoing aortic arch surgery. J Thorac Cardiovasc Surg. 2011;141:815–21.CrossRefPubMed Fischer GW, Lin HM, Krol M, Galati MF, Di Luozzo G, Griepp RB, Reich DL. Noninvasive cerebral oxygenation may predict outcome in patients undergoing aortic arch surgery. J Thorac Cardiovasc Surg. 2011;141:815–21.CrossRefPubMed
Metadata
Title
Cerebral oximetry for cardiac surgery: a preoperative comparison of device characteristics and pitfalls in interpretation
Authors
Kensuke Kobayashi
Tadashi Kitamura
Satoshi Kohira
Shinzo Torii
Toshiaki Mishima
Hirotoki Ohkubo
Yuki Tanaka
Akihiro Sasahara
Takuma Fukunishi
Yuki Ohtomo
Rihito Horikoshi
Yuta Murai
Kagami Miyaji
Publication date
01-12-2018
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 4/2018
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1052-3

Other articles of this Issue 4/2018

Journal of Artificial Organs 4/2018 Go to the issue