Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 4/2018

01-08-2018 | Original Research

Effects of indigo carmine intravenous injection on oxygen reserve index (ORi™) measurement

Authors: Tsuyoshi Isosu, Keisuke Yoshida, Rieko Oishi, Tsuyoshi Imaizumi, Yuzo Iseki, Norie Sanbe, Yukihiro Ikegami, Shinju Obara, Shin Kurosawa, Masahiro Murakawa

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2018

Login to get access

Abstract

To retrospectively investigate the effects of indigo carmine intravenous injection on oxygen reserve index (ORi™) in 20 patients who underwent elective gynecologic surgery under general anesthesia. The study subjects were patients who underwent elective gynecologic surgery under general anesthesia between April 2016 and January 2017, and were administered a 5-ml intravenous injection of 0.4% indigo carmine for clinical purposes during surgery with ORi monitoring. Changes in ORi within 20 min after indigo carmine injection were observed. A relevant decrease in ORi was defined as ≥ 10% reduction in ORi from pre-injection level. ORi rapidly decreased after indigo carmine intravenous injection in all patients. In 10 of 19 patients, ORi decreased to 0 after indigo carmine injection. The median lowest value of ORi was 0 (range 0–0.16) and the median time to reach the lowest value of ORi was 2 min (range 1–4 min) after injection. ORi values returned to pre-injection levels within 20 min in 13 of 19 patients, and the median time to return to pre-injection levels was 10 min (range 6–16 min) after injection. During ORi monitoring it is necessary to consider the rapid reduction in ORi after intravenous injection of indigo carmine.
Literature
4.
go back to reference Scheller MS, Unger RJ, Kelner MJ. Effects of intravenously administered dynes on pulse oximetry readings. Anesthesiology. 1986;65(5):550–1.CrossRef Scheller MS, Unger RJ, Kelner MJ. Effects of intravenously administered dynes on pulse oximetry readings. Anesthesiology. 1986;65(5):550–1.CrossRef
6.
go back to reference Sidi A, Paulus DA, Rush W, Gravenstein N, Davis RF. Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation. Studies in dogs. J Clin Monit. 1987;3(4):249–56.PubMed Sidi A, Paulus DA, Rush W, Gravenstein N, Davis RF. Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation. Studies in dogs. J Clin Monit. 1987;3(4):249–56.PubMed
7.
go back to reference Barker SJ, Tremper KK. Pulse oximetry: applications and limitations. Int Anesthesiol Clin. 1987;25(3):155–75.CrossRef Barker SJ, Tremper KK. Pulse oximetry: applications and limitations. Int Anesthesiol Clin. 1987;25(3):155–75.CrossRef
8.
go back to reference Isosu T, Satoh T, Oishi R, Imaizumi T, Hakozaki T, Obara S, Ikegami Y, Kurosawa S, Murakawa M. Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement. J Clin Monit Comput. 2016;30(3):313–6. doi: 10.1007/s10877-015-9719-2.CrossRefPubMed Isosu T, Satoh T, Oishi R, Imaizumi T, Hakozaki T, Obara S, Ikegami Y, Kurosawa S, Murakawa M. Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement. J Clin Monit Comput. 2016;30(3):313–6. doi: 10.​1007/​s10877-015-9719-2.CrossRefPubMed
9.
go back to reference Isosu T, Obara S, Hakozaki T, Imaizumi T, Iseki Y, Mogami M, Ohashi S, Ikegami Y, Kurosawa S, Murakawa M. Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement with using the Revision L sensor. J Clin Monit Comput. 2017;31(2):485–6. doi:10.1007/s10877-016-9850-8.CrossRefPubMed Isosu T, Obara S, Hakozaki T, Imaizumi T, Iseki Y, Mogami M, Ohashi S, Ikegami Y, Kurosawa S, Murakawa M. Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement with using the Revision L sensor. J Clin Monit Comput. 2017;31(2):485–6. doi:10.​1007/​s10877-016-9850-8.CrossRefPubMed
11.
go back to reference Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T, Mogami M, Murakawa M. Validation of continuous and noninvasive hemoglobin monitoring bypulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2013;27(1):55–60. doi:10.1007/s10877-012-9397-2.CrossRefPubMed Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T, Mogami M, Murakawa M. Validation of continuous and noninvasive hemoglobin monitoring bypulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2013;27(1):55–60. doi:10.​1007/​s10877-012-9397-2.CrossRefPubMed
Metadata
Title
Effects of indigo carmine intravenous injection on oxygen reserve index (ORi™) measurement
Authors
Tsuyoshi Isosu
Keisuke Yoshida
Rieko Oishi
Tsuyoshi Imaizumi
Yuzo Iseki
Norie Sanbe
Yukihiro Ikegami
Shinju Obara
Shin Kurosawa
Masahiro Murakawa
Publication date
01-08-2018
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2018
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0064-5

Other articles of this Issue 4/2018

Journal of Clinical Monitoring and Computing 4/2018 Go to the issue