Abstract

Transcatheter aortic valve implantation (TAVI) with self-expandable Medtronic CoreValve (MCV; Medtronic, Minneapolis, MN) or balloon-expandable Edwards SAPIEN XT valve (ESV; Edwards Lifesciences, Irvine, CA) has been widely used for treatment of high-risk patients with severe aortic stenosis (AS). There is limited data comparing the long-term hemodynamic performance of these two valves. Therefore, this study aimed to compare the short and long-term hemodynamic performance of TAVI with either MCV or ESV. A total of 78 patients who underwent TAVI in our center between June 01, 2012 and January 01, 2014 were enrolled in this retrospective study. For each of the patients we recorded the preprocedural echocardiographic data as well as the post-TAVI echocardiographic outcomes at day one, 6 months and 1 year. The MCV group had lower transaortic gradients than the ESV group, with respect to both maximum (13.4 ± 5.8 vs 18.7 ± 8.1 mmHg, p = 0.001) and mean values (6.5 ± 3.2 vs 9.4 ± 4.3 mmHg, p < 0.001) at post-TAVI day one. These values continued to be significantly lower in the MCV group during post-TAVI 6 months (p < 0.001) and post-TAVI 1 year follow-up (p < 0.05). A paravalvular leak (PVL, grade ≥2) was observed in 6.4 % of patients after TAVI; however, this value decreased over time, and there was no significant difference between the MVC and ESV groups (8.2 vs 3.4 %, p = 0.646). The MCV bioprosthesis was associated with lower transaortic gradients than those of the ESV throughout 1 year of follow-up. The incidence of PVL grade ≥2 in MCV and ESV was comparable.
Literature
1.
go back to reference Leon MB, Smith CR, Mack M et al; PARTNER Trial Investigators (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607CrossRefPubMed Leon MB, Smith CR, Mack M et al; PARTNER Trial Investigators (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607CrossRefPubMed
2.
go back to reference Smith CR, Leon MB, Mack MJ et al; PARTNER Trial Investigators (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198CrossRefPubMed Smith CR, Leon MB, Mack MJ et al; PARTNER Trial Investigators (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198CrossRefPubMed
3.
go back to reference Rodés-Cabau J (2011) Transcatheter aortic valve implantation: current and future approaches. Nat Rev Cardiol 9:15–29CrossRefPubMed Rodés-Cabau J (2011) Transcatheter aortic valve implantation: current and future approaches. Nat Rev Cardiol 9:15–29CrossRefPubMed
4.
go back to reference Grube E, Schuler G, Buellesfeld L et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 50:69–76CrossRefPubMed Grube E, Schuler G, Buellesfeld L et al (2007) Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 50:69–76CrossRefPubMed
5.
go back to reference Grube E, Buellesfeld L, Mueller R et al (2008) Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve revalving system. Circ Cardiovasc Interv 1:167–175CrossRefPubMed Grube E, Buellesfeld L, Mueller R et al (2008) Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve revalving system. Circ Cardiovasc Interv 1:167–175CrossRefPubMed
6.
go back to reference Stokłosa P, Szymański P, Dąbrowski M et al (2015) The impact of transcatheter aortic valve implantation on left ventricular performance and wall thickness––single-centre experience. Postepy Kardiol Interwencyjnej 11:37–43PubMedPubMedCentral Stokłosa P, Szymański P, Dąbrowski M et al (2015) The impact of transcatheter aortic valve implantation on left ventricular performance and wall thickness––single-centre experience. Postepy Kardiol Interwencyjnej 11:37–43PubMedPubMedCentral
7.
go back to reference Moat NE, Ludman P, de Belder MA et al (2011) Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol 58:2130–2138CrossRefPubMed Moat NE, Ludman P, de Belder MA et al (2011) Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol 58:2130–2138CrossRefPubMed
8.
go back to reference Gilard M, Eltchaninoff H, Iung B et al; FRANCE 2 Investigators (2012) Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 366:1705–1715CrossRefPubMed Gilard M, Eltchaninoff H, Iung B et al; FRANCE 2 Investigators (2012) Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 366:1705–1715CrossRefPubMed
9.
go back to reference Nombela-Franco L, Ruel M, Radhakrishnan S et al (2013) Comparison of hemodynamic performance of self-expandable CoreValve vs balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis. Am J Cardiol 111:1026–1033CrossRefPubMed Nombela-Franco L, Ruel M, Radhakrishnan S et al (2013) Comparison of hemodynamic performance of self-expandable CoreValve vs balloon-expandable Edwards SAPIEN aortic valves inserted by catheter for aortic stenosis. Am J Cardiol 111:1026–1033CrossRefPubMed
10.
go back to reference Abdel-Wahab M, Comberg T, Büttner HJ et al; Segeberg-Krozingen TAVI Registry (2014) Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience. JACC Cardiovasc Interv 7:284–292CrossRefPubMed Abdel-Wahab M, Comberg T, Büttner HJ et al; Segeberg-Krozingen TAVI Registry (2014) Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience. JACC Cardiovasc Interv 7:284–292CrossRefPubMed
11.
go back to reference Chang HH, Chen IM, Chen PL, Hsu TL, Lin SM, Chen YH (2015) Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis. J Chin Med Assoc 78:331–338CrossRefPubMed Chang HH, Chen IM, Chen PL, Hsu TL, Lin SM, Chen YH (2015) Comparison of balloon-expandable valves versus self-expandable valves in high-risk patients undergoing transcatheter aortic valve replacement for severe aortic stenosis. J Chin Med Assoc 78:331–338CrossRefPubMed
12.
go back to reference Kasel AM, Cassese S, Ischinger T et al (2014) A prospective, non-randomized comparison of SAPIEN XT and CoreValve implantation in two sequential cohorts of patients with severe aortic stenosis. Am J Cardiovasc Dis 4:87–99PubMedPubMedCentral Kasel AM, Cassese S, Ischinger T et al (2014) A prospective, non-randomized comparison of SAPIEN XT and CoreValve implantation in two sequential cohorts of patients with severe aortic stenosis. Am J Cardiovasc Dis 4:87–99PubMedPubMedCentral
13.
go back to reference Godino C, Maisano F, Montorfano M et al (2010) Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: the Milan experience. JACC Cardiovasc Interv 3:1110–1121CrossRefPubMed Godino C, Maisano F, Montorfano M et al (2010) Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: the Milan experience. JACC Cardiovasc Interv 3:1110–1121CrossRefPubMed
14.
go back to reference Vahanian A, Alfieri O, Andreotti F et al (2012) Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 33:2451–2496CrossRefPubMed Vahanian A, Alfieri O, Andreotti F et al (2012) Guidelines on the management of valvular heart disease (version 2012). Eur Heart J 33:2451–2496CrossRefPubMed
15.
go back to reference Kasel AM, Cassese S, Bleiziffer S et al (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6:249–262CrossRefPubMed Kasel AM, Cassese S, Bleiziffer S et al (2013) Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging 6:249–262CrossRefPubMed
16.
go back to reference Evangelista A, Flachskampf F, Lancellotti P et al (2008) European Association of Echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies. Eur J Echocardiogr 9:438–448CrossRefPubMed Evangelista A, Flachskampf F, Lancellotti P et al (2008) European Association of Echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies. Eur J Echocardiogr 9:438–448CrossRefPubMed
17.
go back to reference Hahn RT, Abraham T, Adams MS et al (2013) Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr 26:921–964CrossRefPubMed Hahn RT, Abraham T, Adams MS et al (2013) Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr 26:921–964CrossRefPubMed
18.
go back to reference Clavel MA, Rodés-Cabau J, Dumont E et al (2011) Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography. JACC Cardiovasc Imaging 4:1053–1062CrossRefPubMed Clavel MA, Rodés-Cabau J, Dumont E et al (2011) Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography. JACC Cardiovasc Imaging 4:1053–1062CrossRefPubMed
19.
go back to reference Zamorano JL, Badano LP, Bruce C et al (2011) EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. J Am Soc Echocardiogr 24:937–965CrossRefPubMed Zamorano JL, Badano LP, Bruce C et al (2011) EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. J Am Soc Echocardiogr 24:937–965CrossRefPubMed
20.
go back to reference Pibarot P, Dumesnil JG (2012) Doppler echocardiographic evaluation of prosthetic valve function. Heart 98:69–78CrossRefPubMed Pibarot P, Dumesnil JG (2012) Doppler echocardiographic evaluation of prosthetic valve function. Heart 98:69–78CrossRefPubMed
21.
go back to reference Zoghbi WA, Chambers JB, Dumesnil JG et al (2009) Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound. J Am Soc Echocardiogr 22:975–1014CrossRefPubMed Zoghbi WA, Chambers JB, Dumesnil JG et al (2009) Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound. J Am Soc Echocardiogr 22:975–1014CrossRefPubMed
22.
go back to reference Spethmann S, Dreger H, Schattke S et al (2012) Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valves. Eur Heart J Cardiovasc Imaging 13:690–696CrossRefPubMed Spethmann S, Dreger H, Schattke S et al (2012) Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valves. Eur Heart J Cardiovasc Imaging 13:690–696CrossRefPubMed
23.
go back to reference Tanrıverdi Z, Dursun H, Kaya D (2015) Comparison of echocardiographic results of CoreValve versus Edwards SAPIEN valves in patients with bicuspid aortic valve. Catheter Cardiovasc Interv. doi:10.1002/ccd.26052 PubMed Tanrıverdi Z, Dursun H, Kaya D (2015) Comparison of echocardiographic results of CoreValve versus Edwards SAPIEN valves in patients with bicuspid aortic valve. Catheter Cardiovasc Interv. doi:10.​1002/​ccd.​26052 PubMed
24.
go back to reference Athappan G, Patvardhan E, Tuzcu EM et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61:1585–1595CrossRefPubMed Athappan G, Patvardhan E, Tuzcu EM et al (2013) Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol 61:1585–1595CrossRefPubMed
25.
go back to reference Généreux P, Head SJ, Wood DA et al (2012) Transcatheter aortic valve implantation: 10-year anniversary part II: clinical implications. Eur Heart J 33:2399–2402CrossRefPubMed Généreux P, Head SJ, Wood DA et al (2012) Transcatheter aortic valve implantation: 10-year anniversary part II: clinical implications. Eur Heart J 33:2399–2402CrossRefPubMed
26.
go back to reference Hahn RT, Kodali S, Généreux P et al (2014) Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance. Curr Cardiol Rep 16:475CrossRefPubMed Hahn RT, Kodali S, Généreux P et al (2014) Paravalvular regurgitation following transcutaneous aortic valve replacement: predictors and clinical significance. Curr Cardiol Rep 16:475CrossRefPubMed
27.
go back to reference Lerakis S, Hayek SS, Douglas PS (2013) Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation 127:397–407CrossRefPubMed Lerakis S, Hayek SS, Douglas PS (2013) Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation 127:397–407CrossRefPubMed
28.
go back to reference Dvir D, Barbash IM, Ben-Dor I et al (2013) Paravalvular regurgitation after transcatheter aortic valve replacement: diagnosis, clinical outcome, preventive and therapeutic strategies. Cardiovasc Revasc Med 14:174–181CrossRefPubMed Dvir D, Barbash IM, Ben-Dor I et al (2013) Paravalvular regurgitation after transcatheter aortic valve replacement: diagnosis, clinical outcome, preventive and therapeutic strategies. Cardiovasc Revasc Med 14:174–181CrossRefPubMed
29.
go back to reference Abdel-Wahab M, Mehilli J, Frerker C et al; CHOICE investigators (2014) Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA 311:1503–1514CrossRefPubMed Abdel-Wahab M, Mehilli J, Frerker C et al; CHOICE investigators (2014) Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA 311:1503–1514CrossRefPubMed
30.
go back to reference O’Sullivan KE, Gough A, Segurado R et al (2014) Is valve choice a significant determinant of paravalvular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis. Eur J Cardiothorac Surg 45:826–833CrossRefPubMed O’Sullivan KE, Gough A, Segurado R et al (2014) Is valve choice a significant determinant of paravalvular leak post-transcatheter aortic valve implantation? A systematic review and meta-analysis. Eur J Cardiothorac Surg 45:826–833CrossRefPubMed
31.
go back to reference Zegdi R, Lecuyer L, Achouh P et al (2010) Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves. Ann Thorac Surg 89:768–772CrossRefPubMed Zegdi R, Lecuyer L, Achouh P et al (2010) Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves. Ann Thorac Surg 89:768–772CrossRefPubMed
32.
go back to reference Tzamtzis S, Viquerat J, Yap J et al (2013) Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med Eng Phys 35:125–130CrossRefPubMed Tzamtzis S, Viquerat J, Yap J et al (2013) Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI). Med Eng Phys 35:125–130CrossRefPubMed
33.
go back to reference Jilaihawi H, Chin D, Spyt T et al (2010) Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic CoreValve bioprosthesis. Eur Heart J 31:857–864CrossRefPubMed Jilaihawi H, Chin D, Spyt T et al (2010) Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic CoreValve bioprosthesis. Eur Heart J 31:857–864CrossRefPubMed
34.
go back to reference Ali OF, Schultz C, Jabbour A et al (2015) Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: the role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth. Int J Cardiol 179:539–545CrossRefPubMed Ali OF, Schultz C, Jabbour A et al (2015) Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: the role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth. Int J Cardiol 179:539–545CrossRefPubMed
35.
go back to reference Abdel-Wahab M, Zahn R, Horack M et al (2011) Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 97:899–906CrossRefPubMed Abdel-Wahab M, Zahn R, Horack M et al (2011) Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 97:899–906CrossRefPubMed
36.
go back to reference Tagaki K, Latib A, Al-Lamee R et al (2011) Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter Cardiovasc Interv 78:432–443 Tagaki K, Latib A, Al-Lamee R et al (2011) Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation. Catheter Cardiovasc Interv 78:432–443
37.
go back to reference Bleiziffer S, Mazzitelli D, Opitz A et al (2012) Beyond the short-term: clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients. J Thorac Cardiovasc Surg 143:310–317CrossRefPubMed Bleiziffer S, Mazzitelli D, Opitz A et al (2012) Beyond the short-term: clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients. J Thorac Cardiovasc Surg 143:310–317CrossRefPubMed
38.
go back to reference Kodali SK, Williams MR, Smith CR et al (2012) Two-year outcomes after transcatheter or surgical aortic valve replacement. N Engl J Med 366:1686–1695CrossRefPubMed Kodali SK, Williams MR, Smith CR et al (2012) Two-year outcomes after transcatheter or surgical aortic valve replacement. N Engl J Med 366:1686–1695CrossRefPubMed
39.
go back to reference Kapadia SR, Tuzcu EM, Makkar RR et al (2014) Long-term outcomes of inoperable patients with aortic stenosis randomly assigned to transcatheter aortic valve replacement or standard therapy. Circulation 130:1483–1492CrossRefPubMed Kapadia SR, Tuzcu EM, Makkar RR et al (2014) Long-term outcomes of inoperable patients with aortic stenosis randomly assigned to transcatheter aortic valve replacement or standard therapy. Circulation 130:1483–1492CrossRefPubMed
40.
go back to reference Gurvitch R, Webb JG, Yuan R et al (2011) Aortic annulus diameter determination by multidetector computed tomogra-phy: reproducibility applicability and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4:1235–1245CrossRefPubMed Gurvitch R, Webb JG, Yuan R et al (2011) Aortic annulus diameter determination by multidetector computed tomogra-phy: reproducibility applicability and implications for transcatheter aortic valve implantation. JACC Cardiovasc Interv 4:1235–1245CrossRefPubMed
41.
go back to reference Toggweiler S, Humphries KH, Lee M et al (2013) 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol 61:413–419CrossRefPubMed Toggweiler S, Humphries KH, Lee M et al (2013) 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol 61:413–419CrossRefPubMed
Metadata
Title
Echocardiographic outcomes of self-expandable CoreValve versus balloon-expandable Edwards SAPIEN XT valves: the comparison of two bioprosthesis implanted in a single centre
Authors
Dayimi Kaya
Zulkif Tanriverdi
Huseyin Dursun
Tugce Colluoglu
Publication date
01-09-2016
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 9/2016
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-016-0924-y

Other articles of this Issue 9/2016

The International Journal of Cardiovascular Imaging 9/2016 Go to the issue