Skip to main content
Top
Published in: European Radiology 4/2005

01-04-2005 | Chest

Dynamic echo-planar MR imaging of the diaphragm for a 3D dynamic analysis

Authors: S. Craighero, E. Promayon, P. Baconnier, J. F. Lebas, M. Coulomb

Published in: European Radiology | Issue 4/2005

Login to get access

Abstract

The purpose of this study was to prove the feasibility of 3D reconstructions of the diaphragm during the respiratory cycle using EPI sequences (EPI acquisition, 270 ms/image, on a healthy subject breathing spontaneously and at 0.1 Hz). Continuously recorded respiratory signal allowed for retrospective synchronization with respiratory phases for reconstruction of successive diaphragm surfaces using a specifically designed software. Displacements, area and volume changes of the diaphragm were quantified. Our measurements were comparable with the data in the literature. Reconstructed surfaces allowed in vivo diaphragm dynamic evaluation in terms of displacements, area and volume variations. EPI has adequate spatial and temporal resolution for studying diaphragm dynamics during natural breathing.
Literature
1.
go back to reference Cluzel P, Similowski T, Chartrand-Lefebvre C, Zelter M, Derenne JP, Grenier P (2000) Diaphragm and chest wall: assessment of the inspiratory pump with MR imaging—preliminary observations. Radiology 215:574–583PubMed Cluzel P, Similowski T, Chartrand-Lefebvre C, Zelter M, Derenne JP, Grenier P (2000) Diaphragm and chest wall: assessment of the inspiratory pump with MR imaging—preliminary observations. Radiology 215:574–583PubMed
2.
go back to reference Gauthier AP, Verbanck S, Estenne M, Segebarth C, Macklem PT, Paiva M (1994) Three-dimensional reconstruction of in vivo human diaphragm shape at different lung volumes. J Appl Physiol 76:495–506PubMed Gauthier AP, Verbanck S, Estenne M, Segebarth C, Macklem PT, Paiva M (1994) Three-dimensional reconstruction of in vivo human diaphragm shape at different lung volumes. J Appl Physiol 76:495–506PubMed
3.
go back to reference Gierada DS, Curtin JJ, Erickson SJ, Prost RW, Strandt JA, Goodman LR (1997) Fast gradient echo magnetic resonance imaging of the normal diaphragm. J Thorac Imaging 12:70–74PubMed Gierada DS, Curtin JJ, Erickson SJ, Prost RW, Strandt JA, Goodman LR (1997) Fast gradient echo magnetic resonance imaging of the normal diaphragm. J Thorac Imaging 12:70–74PubMed
4.
go back to reference Gierada DS, Hakimian S, Slone RM, Yusen RD (1998) MR analysis of lung volume and thoracic dimensions in patients with emphysema before and after lung volume reduction surgery. Am J Radiol 170:707–714 Gierada DS, Hakimian S, Slone RM, Yusen RD (1998) MR analysis of lung volume and thoracic dimensions in patients with emphysema before and after lung volume reduction surgery. Am J Radiol 170:707–714
5.
go back to reference Paiva M, Verbanck S, Estenne M, Poncelet B, Segebarth C, Macklem PT (1992) Mechanical implications of in vivo human diaphragm shape. J Appl Physiol 72:1407–1412PubMed Paiva M, Verbanck S, Estenne M, Poncelet B, Segebarth C, Macklem PT (1992) Mechanical implications of in vivo human diaphragm shape. J Appl Physiol 72:1407–1412PubMed
6.
go back to reference Pettiaux N, Cassart M, Paiva M, Estenne M (1997) Three-dimensional reconstruction of human diaphragm with the use of spiral computed tomography. J Appl Physiol 82:998–1002CrossRefPubMed Pettiaux N, Cassart M, Paiva M, Estenne M (1997) Three-dimensional reconstruction of human diaphragm with the use of spiral computed tomography. J Appl Physiol 82:998–1002CrossRefPubMed
7.
go back to reference Carter EA, Cleverley JR, Delany DJ, Lea RE (1996) Cine MRI in the diagnosis of a ruptured right hemidiaphragm. Clin Radiol 51:137–140PubMed Carter EA, Cleverley JR, Delany DJ, Lea RE (1996) Cine MRI in the diagnosis of a ruptured right hemidiaphragm. Clin Radiol 51:137–140PubMed
8.
go back to reference Gierada DS, Curtin JJ, Erickson SJ, Prost RW, Strandt JA, Goodman LR (1995) Diaphragmatic motion: fast gradient-recalled-echo MR imaging in healthy subjects. Radiology 194:879–884PubMed Gierada DS, Curtin JJ, Erickson SJ, Prost RW, Strandt JA, Goodman LR (1995) Diaphragmatic motion: fast gradient-recalled-echo MR imaging in healthy subjects. Radiology 194:879–884PubMed
9.
go back to reference Kanematsu M, Takeyoshi I, Ryozo M, Yoshiharu Y, Hiroo G, Yasuhiro S, Hidetaka D (1995) Dynamic MRI of the diaphragm. J Comput Assist Tomogr 19:67–72PubMed Kanematsu M, Takeyoshi I, Ryozo M, Yoshiharu Y, Hiroo G, Yasuhiro S, Hidetaka D (1995) Dynamic MRI of the diaphragm. J Comput Assist Tomogr 19:67–72PubMed
10.
go back to reference Sakai S, Murayama S, Hashiguchi N, Masuda K (1997) Bronchogenic carcinoma invasion of the chest wall: evaluation with dynamic cine MRI during breathing. J Comput Assist Tomogr 21:595–600CrossRefPubMed Sakai S, Murayama S, Hashiguchi N, Masuda K (1997) Bronchogenic carcinoma invasion of the chest wall: evaluation with dynamic cine MRI during breathing. J Comput Assist Tomogr 21:595–600CrossRefPubMed
11.
go back to reference Cassart M, Pettiaux N, Genevois PA, Paiva M, Estenne M (1997) Effect of chronic hyperinflation on diaphragm length and surface area. Am J Respir Crit Care Med 156:504–508PubMed Cassart M, Pettiaux N, Genevois PA, Paiva M, Estenne M (1997) Effect of chronic hyperinflation on diaphragm length and surface area. Am J Respir Crit Care Med 156:504–508PubMed
12.
go back to reference Promayon E, Baconnier P, Puech C (1997) Physically-based model for simulating the human trunk respiration movements. In: Troccaz J, Grimson E, Mösges R (eds) Lecture notes in computer science, vol 1205. Springer, Berlin Heidelberg New York, pp 379–388 Promayon E, Baconnier P, Puech C (1997) Physically-based model for simulating the human trunk respiration movements. In: Troccaz J, Grimson E, Mösges R (eds) Lecture notes in computer science, vol 1205. Springer, Berlin Heidelberg New York, pp 379–388
13.
go back to reference Carnevali P, Ferrigno G, Aliverti A, Pedotti A (1996) A new method for 3D optical analysis of chest wall motion. Technol Health Care 4:43–65PubMed Carnevali P, Ferrigno G, Aliverti A, Pedotti A (1996) A new method for 3D optical analysis of chest wall motion. Technol Health Care 4:43–65PubMed
Metadata
Title
Dynamic echo-planar MR imaging of the diaphragm for a 3D dynamic analysis
Authors
S. Craighero
E. Promayon
P. Baconnier
J. F. Lebas
M. Coulomb
Publication date
01-04-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 4/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2482-2

Other articles of this Issue 4/2005

European Radiology 4/2005 Go to the issue