Skip to main content
Top
Published in: European Radiology 4/2005

01-04-2005 | Musculoskeletal

CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results

Authors: Michael Rieger, Markus Gabl, Hannes Gruber, Werner R. Jaschke, Ammar Mallouhi

Published in: European Radiology | Issue 4/2005

Login to get access

Abstract

Our objective was to evaluate the usefulness of CT virtual preoperative planning in the surgical repositioning of malunited distal radius fracture. Eleven patients with malunited distal radius fracture underwent multislice CT of both wrists. A preoperative workup was performed in a virtual reality environment created from the CT data sets. Virtual planning comprised three main procedures, carrying out the virtual osteotomy of the radius, prediction of the final position of the distal radius after osteotomy and computer-assisted manufacturing of a repositioning device, which was later placed at the surgical osteotomy site to reposition objectively the distal radius fragment before fixation with the osteosynthesis. All patients tolerated the surgical procedure well. During surgery, the orthopedic surgeons were not required in any of the cases to alter the position of the distal radius that was determined by the repositioning device. At postoperative follow-up, the anatomic relationship of the distal radius was restored (radial inclination, 21.4°; volar tilt, 10.3°; ulnar variance, 0.5 mm). Clinically, a significant improvement of pronation (P=0.012), supination (P=0.01), flexion (P=0.001) and extension (P=0.006) was achieved. Pain decreased from 54 to 7 points. CT virtual reality is a valuable adjunct for the preoperative workup and surgical reposition of malunited distal radius fractures.
Literature
1.
go back to reference Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692CrossRefPubMed Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692CrossRefPubMed
2.
go back to reference Luboldt W, Mann C, Tryon CL et al (2002) Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast. Eur Radiol 12:2236–2241PubMed Luboldt W, Mann C, Tryon CL et al (2002) Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast. Eur Radiol 12:2236–2241PubMed
3.
go back to reference Bernhardt TM, Schmidl H, Philipp C, Allhoff EP, Rapp-Bernhardt (2003) Diagnostic potential of virtual cyctoscopy of the bladder: MRI vs CT. Preliminary report. Eur Radiol 13:305–312PubMed Bernhardt TM, Schmidl H, Philipp C, Allhoff EP, Rapp-Bernhardt (2003) Diagnostic potential of virtual cyctoscopy of the bladder: MRI vs CT. Preliminary report. Eur Radiol 13:305–312PubMed
4.
go back to reference Hsieh MS, Tsai MD, Chang WC (2002) Virtual reality simulator for osteotomy and fusion involving the musculoskeletal system. Comput Med Imaging Graph 26:91–101CrossRefPubMed Hsieh MS, Tsai MD, Chang WC (2002) Virtual reality simulator for osteotomy and fusion involving the musculoskeletal system. Comput Med Imaging Graph 26:91–101CrossRefPubMed
5.
go back to reference Montgomery K, Stephanides M, Schendel S (2000) Development and application of a virtual environment for reconstructive surgery. Comput Aided Surg 5:90–97CrossRefPubMed Montgomery K, Stephanides M, Schendel S (2000) Development and application of a virtual environment for reconstructive surgery. Comput Aided Surg 5:90–97CrossRefPubMed
6.
go back to reference Handels H, Ehrhardt J, Plötz W, Pöppl SJ (2001) Three-dimensional planning and simulation of hip operations and computer assisted construction of endoprostheses in bone tumor surgery. Comput Aided Surg 6:65–76CrossRefPubMed Handels H, Ehrhardt J, Plötz W, Pöppl SJ (2001) Three-dimensional planning and simulation of hip operations and computer assisted construction of endoprostheses in bone tumor surgery. Comput Aided Surg 6:65–76CrossRefPubMed
7.
go back to reference McGrory BJ, Amadio PC (1998) Malunion of the distal radius: In: Cooney WP, Linscheid RL, Dobyns JH (eds) The wrist: diagnosis and oparative treatment. Mosby, St Louis, pp 356–384 McGrory BJ, Amadio PC (1998) Malunion of the distal radius: In: Cooney WP, Linscheid RL, Dobyns JH (eds) The wrist: diagnosis and oparative treatment. Mosby, St Louis, pp 356–384
8.
go back to reference Hunt TR, Hastings H II, Graham TJ (1998) A systematic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin 14:239–249PubMed Hunt TR, Hastings H II, Graham TJ (1998) A systematic approach to handling the distal radio-ulnar joint in cases of malunited distal radius fractures. Hand Clin 14:239–249PubMed
9.
go back to reference Bronstein AJ, Trumble TE, Tencer AF (1997) The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study. J Hand Surg 22:258–262PubMed Bronstein AJ, Trumble TE, Tencer AF (1997) The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study. J Hand Surg 22:258–262PubMed
10.
go back to reference Melendez EM (1997) Opening-wedge osteotomy, bone graft, and external fixation for correction of radius malunion. J Hand Surg 22:785–791 Melendez EM (1997) Opening-wedge osteotomy, bone graft, and external fixation for correction of radius malunion. J Hand Surg 22:785–791
11.
go back to reference Prommersberger KJ, Van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg 27:55–65CrossRef Prommersberger KJ, Van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg 27:55–65CrossRef
12.
go back to reference Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28:951–958CrossRef Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28:951–958CrossRef
Metadata
Title
CT virtual reality in the preoperative workup of malunited distal radius fractures: preliminary results
Authors
Michael Rieger
Markus Gabl
Hannes Gruber
Werner R. Jaschke
Ammar Mallouhi
Publication date
01-04-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 4/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2353-x

Other articles of this Issue 4/2005

European Radiology 4/2005 Go to the issue