Abstract

Purpose

The correct position of double-lumen tubes (DLTs) is customarily confirmed after tracheal intubation by bronchoscopy with the patient supine on a headrest. However, displacement of DLTs usually occurs during lateral positioning because of neck extension. This study was undertaken to determine whether displacement of DLTs could be minimized during lateral positioning if DLTs were positioned without a headrest.

Methods

One hundred patients scheduled for thoracic surgery were randomized into two groups (n = 50 each). After tracheal intubation using a headrest, adjustment of DLT position was performed according to group assignment, i.e., either with the headrest in place or without the headrest. Using a bronchoscope, distances from the tracheal opening to the main carina and from the bronchial opening to the left bronchial carina were measured in both the supine and lateral positions.

Results

Displacement of DLTs [mean (standard deviation)] during lateral positioning was greater in the headrest group than in the no-headrest group [12.3 (6.5) mm vs 6.8 (5.5) mm, respectively, in the trachea; 11.6 (6.7) mm vs 6.0 (4.6) mm, respectively, in the bronchus; P < 0.001]. The incidence of significant displacement, defined as > 10 mm from initial correct position, was greater in the headrest group than in the no-headrest group (64% vs 28%, respectively, in the trachea; 58% vs 20%, respectively, in the bronchus; P < 0.001).

Conclusion

Displacement of DLTs during lateral positioning appears to be caused primarily by extension of the neck. Correct adjustment of DLT position without a headrest in the supine position is an easy and effective method to minimize DLT displacement during lateral positioning (ClinicalTrials.gov number, NCT01413347).
Literature
1.
go back to reference Brodsky JB, Shulman MS, Mark JB. Malposition of left-sided double-lumen endobronchial tubes. Anesthesiology 1985; 62: 667-9.PubMedCrossRef Brodsky JB, Shulman MS, Mark JB. Malposition of left-sided double-lumen endobronchial tubes. Anesthesiology 1985; 62: 667-9.PubMedCrossRef
2.
go back to reference Saito S, Dohi S, Naito H. Alteration of double-lumen endobronchial tube position by flexion and extension of the neck. Anesthesiology 1985; 62: 696-7.PubMedCrossRef Saito S, Dohi S, Naito H. Alteration of double-lumen endobronchial tube position by flexion and extension of the neck. Anesthesiology 1985; 62: 696-7.PubMedCrossRef
3.
go back to reference Riley RH, Marples IL. Relocation of a double-lumen tube during patient positioning. Anesth Analg 1992; 75: 1071.PubMedCrossRef Riley RH, Marples IL. Relocation of a double-lumen tube during patient positioning. Anesth Analg 1992; 75: 1071.PubMedCrossRef
4.
go back to reference Yazigi A, Madi-Jebara S, Haddad F, Antakly MC. Relocation of a double-lumen tube during surgical dissection. Anesth Analg 1993; 77: 1303.PubMedCrossRef Yazigi A, Madi-Jebara S, Haddad F, Antakly MC. Relocation of a double-lumen tube during surgical dissection. Anesth Analg 1993; 77: 1303.PubMedCrossRef
5.
go back to reference Yoon TG, Chang HW, Ryu HG, Kwon TD, Bahk JH. Use of a neck brace minimizes double-lumen tube displacement during patient positioning. Can J Anesth 2005; 52: 413-7.PubMedCrossRef Yoon TG, Chang HW, Ryu HG, Kwon TD, Bahk JH. Use of a neck brace minimizes double-lumen tube displacement during patient positioning. Can J Anesth 2005; 52: 413-7.PubMedCrossRef
6.
go back to reference Desiderio DP, Burt M, Kolker AC, Fischer ME, Reinsel R, Wilson RS. The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning. J Cardiothorac Vasc Anesth 1997; 11: 595-8.PubMedCrossRef Desiderio DP, Burt M, Kolker AC, Fischer ME, Reinsel R, Wilson RS. The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning. J Cardiothorac Vasc Anesth 1997; 11: 595-8.PubMedCrossRef
7.
go back to reference Fortier G, Cote D, Bergeron C, Bussieres JS. New landmarks improve the positioning of the left Broncho-Cath™ double-lumen tube-comparison with the classic technique. Can J Anesth 2001; 48: 790-4.PubMedCrossRef Fortier G, Cote D, Bergeron C, Bussieres JS. New landmarks improve the positioning of the left Broncho-Cath™ double-lumen tube-comparison with the classic technique. Can J Anesth 2001; 48: 790-4.PubMedCrossRef
8.
go back to reference Bahk JH, Lim YJ, Kim CS. Positioning of a double-lumen endobronchial tube without the aid of any instruments: an implication for emergency management. J Trauma 2000; 49: 899-902.PubMedCrossRef Bahk JH, Lim YJ, Kim CS. Positioning of a double-lumen endobronchial tube without the aid of any instruments: an implication for emergency management. J Trauma 2000; 49: 899-902.PubMedCrossRef
9.
go back to reference Inoue S, Nishimine N, Kitaguchi K, Furuya H, Taniguchi S. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. Br J Anaesth 2004; 92: 195-201.PubMedCrossRef Inoue S, Nishimine N, Kitaguchi K, Furuya H, Taniguchi S. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. Br J Anaesth 2004; 92: 195-201.PubMedCrossRef
10.
go back to reference Kim JT, Kim HJ, Ahn W, et al. Head rotation, flexion, and extension alter endotracheal tube position in adults and children. Can J Anesth 2009; 56: 751-6.PubMedCrossRef Kim JT, Kim HJ, Ahn W, et al. Head rotation, flexion, and extension alter endotracheal tube position in adults and children. Can J Anesth 2009; 56: 751-6.PubMedCrossRef
11.
go back to reference Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729-38.PubMedCrossRef Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology 1987; 67: 729-38.PubMedCrossRef
12.
go back to reference Berry JM. Conventional (laryngoscopic) orotracheal and nasotracheal intubation (single lumen tube). In: Benumof J, Hagberg CA (Eds). Benumof’s Airway Management: Principles and Practice, 2nd ed. Philadelphia: Mosby Elsevier; 2007. p. 379. Berry JM. Conventional (laryngoscopic) orotracheal and nasotracheal intubation (single lumen tube). In: Benumof J, Hagberg CA (Eds). Benumof’s Airway Management: Principles and Practice, 2nd ed. Philadelphia: Mosby Elsevier; 2007. p. 379.
13.
go back to reference Park SH, Park HP, Jeon YT, Hwang JW, Kim JH, Bahk JH. A comparison of direct laryngoscopic views depending on pillow height. J Anesth 2010; 24: 526-30.PubMedCrossRef Park SH, Park HP, Jeon YT, Hwang JW, Kim JH, Bahk JH. A comparison of direct laryngoscopic views depending on pillow height. J Anesth 2010; 24: 526-30.PubMedCrossRef
Metadata
Title
Double-lumen tube placement with the patient in the supine position without a headrest minimizes displacement during lateral positioning
Authors
Jeong-Hwa Seo, MD
Deok Man Hong, MD
Jung-Man Lee, MD
Eun-Jin Chung, MD
Jae-Hyon Bahk, MD
Publication date
01-05-2012
Publisher
Springer-Verlag
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 5/2012
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-012-9679-7

Other articles of this Issue 5/2012

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 5/2012 Go to the issue