Skip to main content
Top
Published in: European Radiology 6/2004

01-06-2004 | Pediatric

Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation

Authors: H. Greess, J. Lutze, A. Nömayr, H. Wolf, T. Hothorn, W. A. Kalender, W. Bautz

Published in: European Radiology | Issue 6/2004

Login to get access

Abstract

The potential of online tube current modulation in subsecond multislice spiral CT (MSCT) examinations of children to reduce the dose without a loss in image quality is investigated in a controlled patient study. The dose can be reduced for oval patient sectional view without an increase in noise if the tube current is reduced where the patient diameter and, consequently, attenuation are small. We investigated a product version of an online control for tube current in a SOMATOM Sensation 4 (Siemens, Forchheim). We evaluated image quality, noise and dose reduction for examinations with online tube current modulation in 30 MSCT of thorax/abdomen and abdomen and compared mA s for tube current modulation to the mA s in standard weight-adapted children protocols. Image quality was rated as “very good,” “good,” “diagnostic” and “poor” in a consensus by three radiologists. Noise was assessed in comparison to 24 MSCT examinations without tube current modulation measured as SD in ROIs. The dose was reduced from 26 to 43% (mean 36%), depending on the patient’s geometry and weight. In general, no loss of image quality was observed. Measured noise showed a decrease up to 26% and an increase up to 36%, although there was no decrease of image quality. Online tube current modulation is now used as a standard in MSCT at our institution. Dose in MSCT examinations of children can be reduced substantially in routine examinations by online tube current modulation without a loss of image quality.
Literature
1.
go back to reference Rogers LF (2001) Taking care of children. Check out the parameters used for helical CT. Am J Roentgenol 176:287PubMed Rogers LF (2001) Taking care of children. Check out the parameters used for helical CT. Am J Roentgenol 176:287PubMed
2.
go back to reference Ware D, Huda W, Mergo P, Litwiller A (1999) Radiation effective doses to patients undergoing abdominal CT examinations. Radiology 210:645–650PubMed Ware D, Huda W, Mergo P, Litwiller A (1999) Radiation effective doses to patients undergoing abdominal CT examinations. Radiology 210:645–650PubMed
3.
go back to reference Giacomuzzi SM, Erckert B, Freund MC, Schöpf T, Dessl A, Jaschke W (1996) Dosisreduktion in der Computertomographie mit einem neuen Scan Verfahren. Akt Radiol 6:110–113 Giacomuzzi SM, Erckert B, Freund MC, Schöpf T, Dessl A, Jaschke W (1996) Dosisreduktion in der Computertomographie mit einem neuen Scan Verfahren. Akt Radiol 6:110–113
4.
go back to reference Kopka L, Funke M, Breitner N, Hermann K-P, Vosshenrich R, Grabbe E (1995) Anatomisch adaptierte Variation des Röhrenstroms bei der CT. Untersuchungen zur Strahlendosisreduktion und Bildqualität. Fortschr Röntgenstr 163:383–387 Kopka L, Funke M, Breitner N, Hermann K-P, Vosshenrich R, Grabbe E (1995) Anatomisch adaptierte Variation des Röhrenstroms bei der CT. Untersuchungen zur Strahlendosisreduktion und Bildqualität. Fortschr Röntgenstr 163:383–387
5.
go back to reference Lehmann KJ, Wild J, Georgi M (1997) Klinischer Einsatz der Software gesteuerten Röhrenstrommodulation „SmartScan“ in der Spiral-CT. Akt Radiol 7:156–158 Lehmann KJ, Wild J, Georgi M (1997) Klinischer Einsatz der Software gesteuerten Röhrenstrommodulation „SmartScan“ in der Spiral-CT. Akt Radiol 7:156–158
6.
go back to reference Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA (1999) Dose reduction in CT by on-line tube current control: principles and validation on phantom and cadavers. Eur Radiol 9:323–328CrossRefPubMed Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA (1999) Dose reduction in CT by on-line tube current control: principles and validation on phantom and cadavers. Eur Radiol 9:323–328CrossRefPubMed
7.
go back to reference Greess H, Wolf H, Kalender WA, Bautz W (1998) Dose reduction in CT anatomically adapted tube current modulation: first patient studies. In: Glazer G, Krestin G (eds) Advances in CT IV. Springer, Berlin Heidelberg New York, pp 35–40 Greess H, Wolf H, Kalender WA, Bautz W (1998) Dose reduction in CT anatomically adapted tube current modulation: first patient studies. In: Glazer G, Krestin G (eds) Advances in CT IV. Springer, Berlin Heidelberg New York, pp 35–40
8.
go back to reference Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender WA, Bautz W (2000) Dose reduction in computed tomography by attenuation based on on-line modulation of the tube current: evaluation of six anatomical regions. Eur Radiol 10:391–394PubMed Greess H, Wolf H, Baum U, Lell M, Pirkl M, Kalender WA, Bautz W (2000) Dose reduction in computed tomography by attenuation based on on-line modulation of the tube current: evaluation of six anatomical regions. Eur Radiol 10:391–394PubMed
9.
go back to reference Greess H, Nömayr A, Wolf H, Baum U, Lell M, Böwing B, Kalender WA, Bautz WA (2002) Dose reduction in CT examination of children by attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed Greess H, Nömayr A, Wolf H, Baum U, Lell M, Böwing B, Kalender WA, Bautz WA (2002) Dose reduction in CT examination of children by attenuation-based on-line modulation of tube current (CARE Dose). Eur Radiol 12:1571–1576PubMed
10.
go back to reference Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz W (1998) Dose reduction in CT by anatomically adapted tube current modulation: principles and first results. In: Glazer G, Krestin G (eds) Advances in CT IV. Springer, Berlin Heidelberg New York, pp 27–34 Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz W (1998) Dose reduction in CT by anatomically adapted tube current modulation: principles and first results. In: Glazer G, Krestin G (eds) Advances in CT IV. Springer, Berlin Heidelberg New York, pp 27–34
11.
go back to reference Kalender WA, Wolf H, Suess Ch (1999) Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. Med Phys 26:2248–2253PubMed Kalender WA, Wolf H, Suess Ch (1999) Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. Med Phys 26:2248–2253PubMed
12.
go back to reference Ihaka R, Gentlemen R (1996) R: a language for data analysis and graphics. J Comput and Graph Stat 5:299–314 Ihaka R, Gentlemen R (1996) R: a language for data analysis and graphics. J Comput and Graph Stat 5:299–314
13.
go back to reference Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2003) Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979–1991CrossRefPubMed Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2003) Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979–1991CrossRefPubMed
14.
go back to reference Cohnen M, Poll LW, Puettmann C, Ewen K, Saleh A, Mödder U (2003) Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153PubMed Cohnen M, Poll LW, Puettmann C, Ewen K, Saleh A, Mödder U (2003) Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153PubMed
15.
go back to reference Ambrosino MM, Genieser NB, Roche KJ, Kaul A, Lawrence RM (1994) Feasibility of high-resolution, low-dose chest CT in evaluating the paediatric chest. Pediatr Radiol 24:6–10PubMed Ambrosino MM, Genieser NB, Roche KJ, Kaul A, Lawrence RM (1994) Feasibility of high-resolution, low-dose chest CT in evaluating the paediatric chest. Pediatr Radiol 24:6–10PubMed
16.
go back to reference Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, Thomas SR, Frush DP (2001) Minimizing radiation dose for paediatric body: applications of single-detector helical CT. Strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed Donnelly LF, Emery KH, Brody AS, Laor T, Gylys-Morin VM, Anton CG, Thomas SR, Frush DP (2001) Minimizing radiation dose for paediatric body: applications of single-detector helical CT. Strategies at a large children’s hospital. Am J Roentgenol 176:303–306PubMed
17.
go back to reference Vock P (2002) CT Exposition beim Kind: Geht das Erwachen der Amerikaner uns Europäer an? Radiologe 42:679–702CrossRef Vock P (2002) CT Exposition beim Kind: Geht das Erwachen der Amerikaner uns Europäer an? Radiologe 42:679–702CrossRef
Metadata
Title
Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
Authors
H. Greess
J. Lutze
A. Nömayr
H. Wolf
T. Hothorn
W. A. Kalender
W. Bautz
Publication date
01-06-2004
Publisher
Springer-Verlag
Published in
European Radiology / Issue 6/2004
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2301-9

Other articles of this Issue 6/2004

European Radiology 6/2004 Go to the issue