Abstract

Objective

To develop and validate one low-cost and easy-use domestically produced Chinese minimally invasive surgical robot system “Micro Hand S” that surgeons can use to resolve the complicated surgeries challenge.

Methods

From April 2014 to April 2015, one patient with gastric perforation, three patients with acute appendicitis, five patients with acute cholecystitis, and one patient with right colon cancer underwent robotic-assisted surgeries. Eight of these patients were followed for 1 month, and pre- and postoperative changes in blood route test and hepatorenal function examination, surgery duration, hospital stay, total robotic setup time, total robotic operation time, intraoperative blood loss, total postoperative drainage amount, duration of bearing drainage tubes were recorded. Two patients withdrew from the study because of individual privacies.

Results

We accomplished surgical procedures using “Micro Hand S.” No intraoperative complications or technical problems were encountered. All patients recovered and discharged from hospital without complications.

Conclusions

The domestic surgical robot system “Micro Hand S” was validated as safe and effective through these clinical cases. The proposed design method is an effective way to make “Micro Hand S” become low-cost and easy-use robot system.
Literature
1.
go back to reference Guthart GS, Salisbury JK Jr (2000) The intuitive telesurgery system: overview and application. In: Proceedings of the 2000 IEEE international conference on robotics and automation, Apr 24–28. San Francisco, CA, pp 618–621 Guthart GS, Salisbury JK Jr (2000) The intuitive telesurgery system: overview and application. In: Proceedings of the 2000 IEEE international conference on robotics and automation, Apr 24–28. San Francisco, CA, pp 618–621
2.
go back to reference Freschi C, Ferrari V, Melfi F, Ferrari M, Mosca F, Cuschieri A (2013) Technical review of the da Vinci surgical telemanipulator. Int J Med Robotics Comput Assist Surgery 9:396–406CrossRef Freschi C, Ferrari V, Melfi F, Ferrari M, Mosca F, Cuschieri A (2013) Technical review of the da Vinci surgical telemanipulator. Int J Med Robotics Comput Assist Surgery 9:396–406CrossRef
3.
go back to reference Zemiti N, Morel G, Ortmaier T, Bonnet N (2007) Mechatronic design of a new robot for force control in minimally invasive surgery. IEEE-ASME T Mech 12:143–153CrossRef Zemiti N, Morel G, Ortmaier T, Bonnet N (2007) Mechatronic design of a new robot for force control in minimally invasive surgery. IEEE-ASME T Mech 12:143–153CrossRef
4.
go back to reference Berkelman P, Boidard E, Cinquin P, Troccaz J (2003) LER: the light endoscope robot. In: Proceeding of the 2003 IEEE/RSJ international conference on intelligent robots and systems, Oct 27–31. Las Vegas, Nevada, vol 3, pp 2835–2840 Berkelman P, Boidard E, Cinquin P, Troccaz J (2003) LER: the light endoscope robot. In: Proceeding of the 2003 IEEE/RSJ international conference on intelligent robots and systems, Oct 27–31. Las Vegas, Nevada, vol 3, pp 2835–2840
5.
go back to reference Ghodoussi M, Butner SE, Wang YL (2002) Robotic surgery—the transatlantic Case. In: Proceedings of the IEEE international conference on robotics and automation. May. Washington, DC, vol 2, pp 1882–1888 Ghodoussi M, Butner SE, Wang YL (2002) Robotic surgery—the transatlantic Case. In: Proceedings of the IEEE international conference on robotics and automation. May. Washington, DC, vol 2, pp 1882–1888
6.
go back to reference Simaan N, Taylaor RH, Flint P (2004) A dexterous system for laryngeal surgery. In: Proceedings of the IEEE international conference on robotics and automation, Apr 26–May 1. New Orleans, LA, vol 1, pp 351–357 Simaan N, Taylaor RH, Flint P (2004) A dexterous system for laryngeal surgery. In: Proceedings of the IEEE international conference on robotics and automation, Apr 26–May 1. New Orleans, LA, vol 1, pp 351–357
8.
go back to reference Sun LW, Wan MF, Schmid J, Bailly Y, Thakre AA, Yeung CK (2007) Advanced da Vinci surgical system simulator for surgeon training and operation planning. Int J Med Robotics Comput Assist Surg 3:245–251CrossRef Sun LW, Wan MF, Schmid J, Bailly Y, Thakre AA, Yeung CK (2007) Advanced da Vinci surgical system simulator for surgeon training and operation planning. Int J Med Robotics Comput Assist Surg 3:245–251CrossRef
9.
go back to reference Wang LL, Uecker D, Laby KP, Wilson JD, Jordan CS, Wright JW, Ghodoussi M, inventor (2006) Medical robotic arm that is attached to an operating table. Intuitive Surgical, United States patent US 7083571, August 1 Wang LL, Uecker D, Laby KP, Wilson JD, Jordan CS, Wright JW, Ghodoussi M, inventor (2006) Medical robotic arm that is attached to an operating table. Intuitive Surgical, United States patent US 7083571, August 1
Metadata
Title
Domestically produced Chinese minimally invasive surgical robot system “Micro Hand S” is applied to clinical surgery preliminarily in China
Authors
Bo Yi
Guohui Wang
Jianmin Li
Juan Jiang
Zhi Son
Han Su
Shaihong Zhu
Shuxin Wang
Publication date
01-01-2017
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 1/2017
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-4945-3

Other articles of this Issue 1/2017

Surgical Endoscopy 1/2017 Go to the issue