Skip to main content
Top
Published in: Clinical Oral Investigations 9/2022

10-05-2022 | Digital Volume Tomography | Original Article

Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study

Authors: Xing-Yu Piao, Ji-Man Park, Hannah Kim, Youngjun Kim, June-Sung Shim

Published in: Clinical Oral Investigations | Issue 9/2022

Login to get access

Abstract

Objectives

To evaluate whether the accuracy and duration of registration for cone beam computed tomography (CBCT) and intraoral scans differ according to the method of registration and ratio of dental restorations to natural teeth.

Materials and methods

CBCT data and intraoral scans of eligible patients were grouped as follows according to the ratio of the number of dental restorations to the number of natural teeth (N): group 1, N = 0%; group 2, 0% < N < 50%; group 3, 50% ≤ N < 100%; and group 4, 100% ≤ N. Marker-free registration was performed with a deep learning-based platform and four implant planning software with different registration methods (two point-based, one surface-based, and one manual registration software) by a single operator, and the time consumption was recorded. Registration accuracy was evaluated by measuring the distances between the three-dimensional models of CBCT data and intraoral scans.

Results

A total of 36 patients, one jaw per patient, were enrolled. Although registration accuracy was similar, the time consumed for registration significantly differed for the different methods. The deep learning-based registration method consumed the least time. Greater proportions of dental restorations significantly reduced the registration accuracy for semi-automatic and deep learning-based methods and reduced the time consumed for semi-automatic registration.

Conclusions

No superiority in registration accuracy was found. The proportion of dental restorations significantly affects the accuracy and duration of registration for CBCT data and intraoral scans.

Clinical trial registration

ClinicalTrials.​gov Identifier: KCT0006710

Clinical relevance

Registration accuracy for virtual implant planning decreases when the proportion of dental restorations increases regardless of registration methods.
Literature
2.
go back to reference Vercruyssen M, Fortin T, Widmann G, Jacobs R, MJP Q (2014) Different techniques of static/dynamic guided implant surgery: modalities and indications. Periodontol 2000 66:214–227CrossRef Vercruyssen M, Fortin T, Widmann G, Jacobs R, MJP Q (2014) Different techniques of static/dynamic guided implant surgery: modalities and indications. Periodontol 2000 66:214–227CrossRef
3.
go back to reference Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle C, Tahmaseb (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle C, Tahmaseb (2009) Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 24(Suppl):92–109PubMed
4.
go back to reference D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, AJP T (2017) Current state of the art of computer-guided implant surgery. Periodontol 2000 73:121–133CrossRef D'haese J, Ackhurst J, Wismeijer D, De Bruyn H, AJP T (2017) Current state of the art of computer-guided implant surgery. Periodontol 2000 73:121–133CrossRef
8.
go back to reference Fitzpatrick JM, Hill DLG, Maurer CR (2000) Handbook of medical imaging. SPIE, Bellingham Fitzpatrick JM, Hill DLG, Maurer CR (2000) Handbook of medical imaging. SPIE, Bellingham
10.
12.
go back to reference Nkenke E, Zachow S, Benz M, Maier T, Veit K, Kramer M, Benz S, Hausler G, Neukam FW, Lell M (2004) Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery. Dentomaxillofac Radiol 33:226–232. https://doi.org/10.1259/dmfr/27071199CrossRefPubMed Nkenke E, Zachow S, Benz M, Maier T, Veit K, Kramer M, Benz S, Hausler G, Neukam FW, Lell M (2004) Fusion of computed tomography data and optical 3D images of the dentition for streak artefact correction in the simulation of orthognathic surgery. Dentomaxillofac Radiol 33:226–232. https://​doi.​org/​10.​1259/​dmfr/​27071199CrossRefPubMed
13.
go back to reference Park SW, Yoon RG, Lee H, Lee HJ, Choi YD, Lee DH (2020) Impacts of thresholds of gray value for cone-beam computed tomography 3D reconstruction on the accuracy of image matching with optical scan. Int J Environ Res Public Health 17. https://doi.org/10.3390/ijerph17176375 Park SW, Yoon RG, Lee H, Lee HJ, Choi YD, Lee DH (2020) Impacts of thresholds of gray value for cone-beam computed tomography 3D reconstruction on the accuracy of image matching with optical scan. Int J Environ Res Public Health 17. https://​doi.​org/​10.​3390/​ijerph17176375
15.
21.
go back to reference Jamjoom FZ, Yilmaz B, Johnston WM (2019) Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: An in vitro study. Clin Oral Implants Res 30:826–832. https://doi.org/10.1111/clr.13490CrossRefPubMed Jamjoom FZ, Yilmaz B, Johnston WM (2019) Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: An in vitro study. Clin Oral Implants Res 30:826–832. https://​doi.​org/​10.​1111/​clr.​13490CrossRefPubMed
27.
Metadata
Title
Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study
Authors
Xing-Yu Piao
Ji-Man Park
Hannah Kim
Youngjun Kim
June-Sung Shim
Publication date
10-05-2022
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 9/2022
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-022-04533-7

Other articles of this Issue 9/2022

Clinical Oral Investigations 9/2022 Go to the issue