Excerpt

Amazingly, in spite of the arrival of newer imaging methods (stress echocardiography, coronary CTA, cardiac MRI), cardiac SPECT myocardial perfusion imaging (MPI) remains the most commonly used noninvasive test for detection of obstructive epicardial coronary artery disease (CAD). The diagnostic and prognostic value of cardiac SPECT has been well studied and documented over the years, intermittently punctuated by the advent of new tracers (Tc-99m sestamibi and Tc-99m tetrofosmin), new camera technology (dual-head and high-efficiency cameras), and new stressors (adenosine and regadenoson). …
Literature
1.
go back to reference Hendel RC, Gibbons RJ, Bateman TM. Use of rotating (cine) planar projection images in the interpretation of a tomographic myocardial perfusion study. J Nucl Cardiol. 1999;6:234–40.CrossRef Hendel RC, Gibbons RJ, Bateman TM. Use of rotating (cine) planar projection images in the interpretation of a tomographic myocardial perfusion study. J Nucl Cardiol. 1999;6:234–40.CrossRef
2.
go back to reference Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69–77.CrossRef Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69–77.CrossRef
3.
go back to reference Berman DS, Kang X, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients. J Nucl Cardiol. 2006;13:191–201.CrossRef Berman DS, Kang X, Nishina H, Slomka PJ, Shaw LJ, Hayes SW, et al. Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients. J Nucl Cardiol. 2006;13:191–201.CrossRef
4.
go back to reference DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med. 1995;36:952–5.PubMed DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med. 1995;36:952–5.PubMed
5.
go back to reference Cooper JA, Neumann PH, McCandless BK. Effect of patient motion on tomographic myocardial perfusion imaging. J Nucl Med. 1992;33:1566–71.PubMed Cooper JA, Neumann PH, McCandless BK. Effect of patient motion on tomographic myocardial perfusion imaging. J Nucl Med. 1992;33:1566–71.PubMed
6.
go back to reference DePuey EG. Image Artifact. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging: Principles and applications. 5th ed. New York: Oxford University Press; 2016. DePuey EG. Image Artifact. In: Iskandrian AE, Garcia EV, editors. Nuclear cardiac imaging: Principles and applications. 5th ed. New York: Oxford University Press; 2016.
7.
go back to reference Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927–34.CrossRef Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927–34.CrossRef
8.
go back to reference Mannarino T, Assante R, Ricciardi C, Zampella E, Nappi C, Gaudieri V, et al. Head-to-head comparison of diagnostic accuracy of stress-only myocardial perfusion imaging with conventional and cadmium-zinc telluride single-photon emission computed tomography in women with suspected coronary artery disease. J Nucl Cardiol. 2019. https://doi.org/10.1007/s12350-019-01789-7.CrossRefPubMed Mannarino T, Assante R, Ricciardi C, Zampella E, Nappi C, Gaudieri V, et al. Head-to-head comparison of diagnostic accuracy of stress-only myocardial perfusion imaging with conventional and cadmium-zinc telluride single-photon emission computed tomography in women with suspected coronary artery disease. J Nucl Cardiol. 2019. https://​doi.​org/​10.​1007/​s12350-019-01789-7.CrossRefPubMed
Metadata
Title
Did we solve soft tissue (breast) attenuation?
Authors
Milena J. Henzlova, MD
W. Lane Duvall, MD
Publication date
01-06-2021
Publisher
Springer International Publishing
Published in
Journal of Nuclear Cardiology / Issue 3/2021
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-019-01870-1

Other articles of this Issue 3/2021

Journal of Nuclear Cardiology 3/2021 Go to the issue