Abstract

Purpose

This study aimed to evaluate image quality and diagnostic performance of a recently developed navigated three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with compressed sensing (CS) based on parallel imaging (PI) and conventional 3D-MRCP with PI only in patients with abnormal bile duct dilatation.

Methods

This institutional review board-approved study included 45 consecutive patients [non-malignant common bile duct lesions (n = 21) and malignant common bile duct lesions (n = 24)] who underwent MRCP of the abdomen to evaluate bile duct dilatation. All patients were imaged at 3T (MR 750, GE Healthcare, Waukesha, WI) including two kinds of 3D-MRCP using 352 × 288 matrices with and without CS based on PI. Two radiologists independently and blindly assessed randomized images.

Results

CS acceleration reduced the acquisition time on average 5 min and 6 s to a total of 2 min and 56 s. The all CS cine image quality was significantly higher than standard cine MR image for all quantitative measurements. Diagnostic accuracy for benign and malignant lesions is statistically different between standard and CS 3D-MRCP.

Conclusions

Total image quality and diagnostic accuracy at biliary obstruction evaluation demonstrates that CS-accelerated 3D-MRCP sequences can provide superior quality of diagnostic information in 42.5% less time. This has the potential to reduce motion-related artifacts and improve diagnostic efficacy.
Literature
1.
go back to reference Palmucci S, Mauro LA, Coppolino M, et al. (2010) Evaluation of the biliary and pancreatic systmen with 2D SSFSE, breathhold 3D FRFSE and respiratory-triggered 3D FRFSE sequence. Radiol Med 115:467–482CrossRefPubMed Palmucci S, Mauro LA, Coppolino M, et al. (2010) Evaluation of the biliary and pancreatic systmen with 2D SSFSE, breathhold 3D FRFSE and respiratory-triggered 3D FRFSE sequence. Radiol Med 115:467–482CrossRefPubMed
2.
go back to reference Choi JY, Lee JM, Lee JY, et al. (2008) Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstruction: comparison with direct cholangiography. J Magn Reson Imaging 27:94–101CrossRefPubMed Choi JY, Lee JM, Lee JY, et al. (2008) Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstruction: comparison with direct cholangiography. J Magn Reson Imaging 27:94–101CrossRefPubMed
3.
go back to reference Hirao K, Miyazaki A, Fujimato T, Isomoto I, Hayashi K (2000) Evaluation of aberrant bile ducts before laparoscopic cholecystectomy: helical CT cholangiography versus MR cholangiography. AJR 175:713–720CrossRefPubMed Hirao K, Miyazaki A, Fujimato T, Isomoto I, Hayashi K (2000) Evaluation of aberrant bile ducts before laparoscopic cholecystectomy: helical CT cholangiography versus MR cholangiography. AJR 175:713–720CrossRefPubMed
4.
go back to reference Schoroeder T, Malago M, Debatin JF, et al. (2005) “All-in-one” imaging protocols for the evaluation of potential living liver donors: comparison of magnetic resonance imaging and multidetector computed tomography. Liver Transpl 11:776–787CrossRef Schoroeder T, Malago M, Debatin JF, et al. (2005) “All-in-one” imaging protocols for the evaluation of potential living liver donors: comparison of magnetic resonance imaging and multidetector computed tomography. Liver Transpl 11:776–787CrossRef
5.
go back to reference Morita S, Saito N, Suzuki K, Mitsuhashi N (2009) Biliary anatomy of 3D MRCP: comparison of volume-rendering and maximum-intensity projection algorithms. J Magn Reson Imaging 29:601–606CrossRefPubMed Morita S, Saito N, Suzuki K, Mitsuhashi N (2009) Biliary anatomy of 3D MRCP: comparison of volume-rendering and maximum-intensity projection algorithms. J Magn Reson Imaging 29:601–606CrossRefPubMed
6.
go back to reference Gamper U, Boesiger P, Kozerke S (2008) Compressed sensing in dynamic MRI. Magn Reson Med 59:365–373CrossRefPubMed Gamper U, Boesiger P, Kozerke S (2008) Compressed sensing in dynamic MRI. Magn Reson Med 59:365–373CrossRefPubMed
7.
go back to reference Hollingsworth KG (2015) Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction. Phys Med Biol 60:297–322CrossRef Hollingsworth KG (2015) Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction. Phys Med Biol 60:297–322CrossRef
8.
go back to reference Lustig M, Donoho DL, Santos JM, Pauly JM (2008) Compressed sensing MRI: a look at how CS can improve on current imaging techniques (Review). IEEE Signal Process Mag 25:72–82CrossRef Lustig M, Donoho DL, Santos JM, Pauly JM (2008) Compressed sensing MRI: a look at how CS can improve on current imaging techniques (Review). IEEE Signal Process Mag 25:72–82CrossRef
9.
go back to reference Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRefPubMed Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRefPubMed
10.
go back to reference Chandarba H, Feng L, Block TK, et al. (2013) Free-breathing contrast-enhanced multiplphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden–angle radial sampling. Investig Radiol 48:10–16CrossRef Chandarba H, Feng L, Block TK, et al. (2013) Free-breathing contrast-enhanced multiplphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden–angle radial sampling. Investig Radiol 48:10–16CrossRef
11.
go back to reference Feng L, Benkert T, Block KT, et al. (2017) Compressed sensing for body MRI. J Magn Reson Imaging. 45:966–987CrossRefPubMed Feng L, Benkert T, Block KT, et al. (2017) Compressed sensing for body MRI. J Magn Reson Imaging. 45:966–987CrossRefPubMed
12.
go back to reference Yang AC, Kretzler M, Sudarski S, Gulani V, Seiberlich N (2016) Sparse reconstruction techniques in magnetic resonance imaging: methods, applications, and challenges to clinical adoption. Investig Radiol 51:349–364CrossRef Yang AC, Kretzler M, Sudarski S, Gulani V, Seiberlich N (2016) Sparse reconstruction techniques in magnetic resonance imaging: methods, applications, and challenges to clinical adoption. Investig Radiol 51:349–364CrossRef
13.
go back to reference Zhang T, Chowdhury S, Lustig M, et al. (2014) Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. J Magn Reson Imaging 40:13–25CrossRefPubMed Zhang T, Chowdhury S, Lustig M, et al. (2014) Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction. J Magn Reson Imaging 40:13–25CrossRefPubMed
14.
go back to reference Brau AC, Beatty PJ, Skare S, Bammer R (2008) Comparision of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 59:382–395CrossRefPubMedPubMedCentral Brau AC, Beatty PJ, Skare S, Bammer R (2008) Comparision of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 59:382–395CrossRefPubMedPubMedCentral
15.
go back to reference Beatty P, Brau A, Chang S (2007) A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proceedings of the 15th annual meeting ISMRM, Berlin, p 1749 Beatty P, Brau A, Chang S (2007) A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proceedings of the 15th annual meeting ISMRM, Berlin, p 1749
16.
go back to reference Griswold MA, Jakob PM, Heidemann RM, et al. (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1201–1210CrossRef Griswold MA, Jakob PM, Heidemann RM, et al. (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1201–1210CrossRef
17.
go back to reference Bartko JJ (1966) The intraclass correlation coefficient as a measure of reliability. Psychol Rep 19:3–11CrossRefPubMed Bartko JJ (1966) The intraclass correlation coefficient as a measure of reliability. Psychol Rep 19:3–11CrossRefPubMed
18.
go back to reference Hall-Craggs MA, Allen CM, Owens CM, et al. (1993) MR cholangiography; clinical evaluation in 40 cases. Radiology 189:423–427CrossRefPubMed Hall-Craggs MA, Allen CM, Owens CM, et al. (1993) MR cholangiography; clinical evaluation in 40 cases. Radiology 189:423–427CrossRefPubMed
19.
go back to reference Cantes E, Romberg J, Tao T (2006) Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 55:489–509CrossRef Cantes E, Romberg J, Tao T (2006) Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 55:489–509CrossRef
20.
21.
go back to reference Yoon JH, Lee SM, Kang HJ, et al. (2017) Clinical feasibility of 3D-dimensional magnetic resonance cholangiopancreatography using compressed sensing. Investig Radiol 52:612–617CrossRef Yoon JH, Lee SM, Kang HJ, et al. (2017) Clinical feasibility of 3D-dimensional magnetic resonance cholangiopancreatography using compressed sensing. Investig Radiol 52:612–617CrossRef
22.
go back to reference Seo N, Park MS, Han KH, et al. (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J. Magn. Reson. Imaging 46(5):1289–1297CrossRefPubMed Seo N, Park MS, Han KH, et al. (2017) Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T. J. Magn. Reson. Imaging 46(5):1289–1297CrossRefPubMed
Metadata
Title
Diagnosing common bile duct obstruction: comparison of image quality and diagnostic performance of three-dimensional magnetic resonance cholangiopancreatography with and without compressed sensing
Authors
Heejin Kwon
Scott Reid
Dongeun Kim
Sangyun Lee
Jinhan Cho
Jongyeong Oh
Publication date
01-09-2018
Publisher
Springer US
Published in
Abdominal Radiology / Issue 9/2018
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-017-1451-6

Other articles of this Issue 9/2018

Abdominal Radiology 9/2018 Go to the issue

Classics in Abdominal Radiology

The “serpent sign” in hydatid disease

Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.