Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 5/2017

01-10-2017 | Original Research

Detection of spine structures with Bioimpedance Probe (BIP) Needle in clinical lumbar punctures

Authors: Sanna Halonen, Kari Annala, Juho Kari, Samuli Jokinen, Aki Lumme, Kai Kronström, Arvi Yli-Hankala

Published in: Journal of Clinical Monitoring and Computing | Issue 5/2017

Login to get access

Abstract

Lumbar puncture is a relatively safe procedure, but some serious, even fatal, complications can occur. Needle guidance can increase puncture accuracy, decrease the number of attempts, and make the procedure easier. We tested the feasibility of a bioimpedance-based tissue-sensing technology for needle guidance in clinical use. The Bioimpedance Probe (BIP) Needle has a removable BIP stylet enabling measurement of bioimpedance spectra during the procedure. The BIP Needle is connected to a measurement device that uses tissue-classification software, and the device provides audiovisual feedback when it detects cerebrospinal fluid (CSF). We performed spinal anesthesia with the BIP Needle in 45 patients. The device performance and needle tip location were verified by an experienced anesthesiologist confirming CSF leakage. The device detected CSF in all cases (sensitivity of 100 %). Six cases with false detections lowered the specificity to 81 %, but in practice, most of these were easy to differentiate from true detections because their duration was short and they occurred during backward movement of the needle. The epidural spectrum differentiated as fatty tissue from surrounding tissues, but the ligamentum flavum was not clearly detectable in the data. The BIP Needle is a reliable tool for detecting CSF in lumbar puncture. It can make the puncture procedure smoother, as repeated CSF flow tests are avoided. The correct needle tip location is immediately detected, thus unnecessary needle movements close to spinal nerves are prevented. Physicians could benefit from the information provided by the BIP Needle, especially in patients with obesity or anatomic alterations.
Literature
1.
go back to reference Hermanides J, Hollmann MW, Stevens MF, Lirk P. Failed epidural: causes and management. Br J Anaesth. 2012;109(2):144–54.CrossRefPubMed Hermanides J, Hollmann MW, Stevens MF, Lirk P. Failed epidural: causes and management. Br J Anaesth. 2012;109(2):144–54.CrossRefPubMed
2.
go back to reference Hyderally H. Complications of spinal anesthesia. Mt Sinai J Med. 2001;69(1–2):55–6. Hyderally H. Complications of spinal anesthesia. Mt Sinai J Med. 2001;69(1–2):55–6.
3.
go back to reference Kang XH, Bao FP, Xiong XX, Li M, Jin TT, Shao J, Zhu SM. Major complications of epidural anesthesia: a prospective study of 5083 cases at a single hospital. Acta Anaesth Scand. 2014;58(7):858–66.CrossRefPubMed Kang XH, Bao FP, Xiong XX, Li M, Jin TT, Shao J, Zhu SM. Major complications of epidural anesthesia: a prospective study of 5083 cases at a single hospital. Acta Anaesth Scand. 2014;58(7):858–66.CrossRefPubMed
4.
go back to reference Pitkänen MT, Aromaa U, Cozanitis DA, Förster JG. Serious complications associated with spinal and epidural anaesthesia in Finland from 2000 to 2009. Acta Anaesth Scand. 2013;57(5):553–64.CrossRefPubMed Pitkänen MT, Aromaa U, Cozanitis DA, Förster JG. Serious complications associated with spinal and epidural anaesthesia in Finland from 2000 to 2009. Acta Anaesth Scand. 2013;57(5):553–64.CrossRefPubMed
5.
go back to reference Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011;115(1):94–101.CrossRefPubMed Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011;115(1):94–101.CrossRefPubMed
6.
go back to reference Seeberger MD, Kaufmann M, Staender S, Schneider M, Scheidegger D. Repeated dural punctures increase the incidence of postdural puncture headache. Anesth Analg. 1996;82(2):302–5.PubMed Seeberger MD, Kaufmann M, Staender S, Schneider M, Scheidegger D. Repeated dural punctures increase the incidence of postdural puncture headache. Anesth Analg. 1996;82(2):302–5.PubMed
7.
go back to reference Kopacz DJ, Neal JM, Pollock JE. The regional anesthesia “learning curve”. What is the minimum number of epidural and spinal blocks to reach consistency? Reg Anesth. 1995;21(3):182–90. Kopacz DJ, Neal JM, Pollock JE. The regional anesthesia “learning curve”. What is the minimum number of epidural and spinal blocks to reach consistency? Reg Anesth. 1995;21(3):182–90.
8.
go back to reference Kalvøy H, Frich L, Grimnes S, Martinsen ØG, Hol PK, Stubhaug A. Impedance-based tissue discrimination for needle guidance. Physiol Meas. 2009;30(2):129–40.CrossRefPubMed Kalvøy H, Frich L, Grimnes S, Martinsen ØG, Hol PK, Stubhaug A. Impedance-based tissue discrimination for needle guidance. Physiol Meas. 2009;30(2):129–40.CrossRefPubMed
9.
go back to reference Trebbels D, Fellhauer F, Jugl M, Haimerl G, Min M, Zengerle R. Online tissue discrimination for transcutaneous needle guidance applications using broadband impedance spectroscopy. IEEE Trans Biomed Eng. 2012;59(2):494–503.CrossRefPubMed Trebbels D, Fellhauer F, Jugl M, Haimerl G, Min M, Zengerle R. Online tissue discrimination for transcutaneous needle guidance applications using broadband impedance spectroscopy. IEEE Trans Biomed Eng. 2012;59(2):494–503.CrossRefPubMed
10.
go back to reference Kalvøy H, Sauter AR. Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel method. J Clin Monitor Comput. 2015;. doi:10.1007/s10877-015-9698-3. Kalvøy H, Sauter AR. Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel method. J Clin Monitor Comput. 2015;. doi:10.​1007/​s10877-015-9698-3.
11.
go back to reference Mishra V, Schned AR, Hartov A, Heaney JA, Seigne J, Halter RJ. Electrical property sensing biopsy needle for prostate cancer detection. Prostate. 2013;73(15):1603–13.PubMed Mishra V, Schned AR, Hartov A, Heaney JA, Seigne J, Halter RJ. Electrical property sensing biopsy needle for prostate cancer detection. Prostate. 2013;73(15):1603–13.PubMed
12.
go back to reference Hernandez DJ, Sinkov VA, Roberts WW, Allaf ME, Patriciu A, Jarrett TW, et al. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access. J Urol. 2001;166(4):1520–3.CrossRefPubMed Hernandez DJ, Sinkov VA, Roberts WW, Allaf ME, Patriciu A, Jarrett TW, et al. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access. J Urol. 2001;166(4):1520–3.CrossRefPubMed
14.
go back to reference Grimness S, Martinsen ØG. Bioimpedance and bioelectricity basics. 2nd ed. London: Academic Press; 2008. Grimness S, Martinsen ØG. Bioimpedance and bioelectricity basics. 2nd ed. London: Academic Press; 2008.
15.
go back to reference Ragheb T, Geddes LA. The polarization impedance of common electrode metals operated at low current density. Ann Biomed Eng. 1991;19(2):151–63.CrossRefPubMed Ragheb T, Geddes LA. The polarization impedance of common electrode metals operated at low current density. Ann Biomed Eng. 1991;19(2):151–63.CrossRefPubMed
16.
go back to reference Schwan HP. Linear and nonlinear electrode polarization and biological materials. Ann Biomed Eng. 1992;20(3):269–88.CrossRefPubMed Schwan HP. Linear and nonlinear electrode polarization and biological materials. Ann Biomed Eng. 1992;20(3):269–88.CrossRefPubMed
17.
go back to reference Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(11):2251–69.CrossRefPubMed Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(11):2251–69.CrossRefPubMed
18.
go back to reference Mirtaheri P, Grimnes S, Martinsen ØG. Electrode polarization impedance in weak NaCl aqueous solutions. IEEE Trans Biomed Eng. 2005;52(12):2093–9.CrossRefPubMed Mirtaheri P, Grimnes S, Martinsen ØG. Electrode polarization impedance in weak NaCl aqueous solutions. IEEE Trans Biomed Eng. 2005;52(12):2093–9.CrossRefPubMed
19.
go back to reference Duda RO, Hart PE, Stork DG. Pattern classification. 2nd ed. New York: John Wiley & Sons; 2012. Duda RO, Hart PE, Stork DG. Pattern classification. 2nd ed. New York: John Wiley & Sons; 2012.
20.
go back to reference De Andrés J, Reina MA, Prats A. Epidural space and regional anesthesia. Eur J Pain Suppl. 2009;3(2):55–63.CrossRef De Andrés J, Reina MA, Prats A. Epidural space and regional anesthesia. Eur J Pain Suppl. 2009;3(2):55–63.CrossRef
21.
go back to reference Baumann SB, Wozny DR, Kelly SK, Meno FM. The electrical conductivity of human cerebrospinal fluid at body temperature. IEEE Trans Biomed Eng. 1997;44(3):220–3.CrossRefPubMed Baumann SB, Wozny DR, Kelly SK, Meno FM. The electrical conductivity of human cerebrospinal fluid at body temperature. IEEE Trans Biomed Eng. 1997;44(3):220–3.CrossRefPubMed
22.
go back to reference Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey. Phys Med Biol. 1996;41(11):2231–349.CrossRefPubMed Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey. Phys Med Biol. 1996;41(11):2231–349.CrossRefPubMed
Metadata
Title
Detection of spine structures with Bioimpedance Probe (BIP) Needle in clinical lumbar punctures
Authors
Sanna Halonen
Kari Annala
Juho Kari
Samuli Jokinen
Aki Lumme
Kai Kronström
Arvi Yli-Hankala
Publication date
01-10-2017
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 5/2017
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-016-9915-8

Other articles of this Issue 5/2017

Journal of Clinical Monitoring and Computing 5/2017 Go to the issue