Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2014

Open Access 01-12-2014 | Research article

Design modifications of high-flexion TKA do not improve short term clinical and radiographic outcomes

Authors: Jai Gon Seo, Young-Wan Moon, Moon Jong Chang, Byung Chul Jo, Yong Beom Park, Deuk Soo Lim, Byung Hoon Lee

Published in: BMC Musculoskeletal Disorders | Issue 1/2014

Login to get access

Abstract

Background

The prosthesis of contemporary total knee arthroplasty (TKA) has been modified to provide a more familiar environment for higher flexion angle of the replaced knee. The design modifications continue based on evidence reported in the literature. However, whether these modifications of the prosthesis design lead to improvements in clinical results needs further investigation. We determined whether the prosthesis modifications based on recent evidence improve clinical and radiographic results following high flexion TKA.

Methods

524 patients who underwent primary TKA using two different high flexion prostheses were divided to Group 1 (HF-1) using a high flexion prosthesis, group 2 (HF-2) using the more recently devised high flexion prosthesis, which claims to be adopted from evidence proposed in the literature. Clinical outcomes included ranges of motion (ROM), the Knee Society knee and function score (KSKS and KSFS), the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score, radiologic evaluation, and complication related to surgery.

Results

No differences in terms of clinical and radiographic results were observed between the groups at the 2 year follow-up. The mean ROM was 123°and 124° in the HF-1 and HF-2 groups, respectively. KSKS were 90 and 89.1, KSFS were 76.6 and 81.8, and total WOMAC scores were 23.1 and 24.9 in the HF-1 and HF- 2 groups. No differences of the incidences of radiolucency on radiographs (1.4% in HF-1, 2.1% in HF-2) and dislocation (1 case in HF-1 only) was observed.

Conclusions

Even if recent modifications in the design of high flexion TKA prosthesis were based on evidence in the literature, they did not provide meaningful improvements in short-term clinical and radiographic outcomes after TKA. Surgeons should consider our findings when choosing a prosthesis for their patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kim JM, Moon MS: Squatting following total knee arthroplasty. Clin Orthop Relat Res. 1995, 177-186. Kim JM, Moon MS: Squatting following total knee arthroplasty. Clin Orthop Relat Res. 1995, 177-186.
2.
go back to reference McCalden RW, MacDonald SJ, Bourne RB, Marr JT: A randomized controlled trial comparing “high-flex” vs “standard” posterior cruciate substituting polyethylene tibial inserts in total knee arthroplasty. J Arthroplasty. 2009, 24: 33-38.CrossRefPubMed McCalden RW, MacDonald SJ, Bourne RB, Marr JT: A randomized controlled trial comparing “high-flex” vs “standard” posterior cruciate substituting polyethylene tibial inserts in total knee arthroplasty. J Arthroplasty. 2009, 24: 33-38.CrossRefPubMed
3.
go back to reference Mulholland SJ, Wyss UP: Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res. 2001, 24: 191-198. 10.1097/00004356-200109000-00004.CrossRefPubMed Mulholland SJ, Wyss UP: Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. Int J Rehabil Res. 2001, 24: 191-198. 10.1097/00004356-200109000-00004.CrossRefPubMed
4.
go back to reference Jones RE: High-flexion rotating-platform knees: rationale, design, and patient selection. Orthopedics. 2006, 29: S76-S79.PubMed Jones RE: High-flexion rotating-platform knees: rationale, design, and patient selection. Orthopedics. 2006, 29: S76-S79.PubMed
5.
go back to reference Gupta SK, Ranawat AS, Shah V, Zikria BA, Zikria JF, Ranawat CS: The P.F.C. sigma RP-F TKA designed for improved performance: a matched-pair study. Orthopedics. 2006, 29: S49-S52.PubMed Gupta SK, Ranawat AS, Shah V, Zikria BA, Zikria JF, Ranawat CS: The P.F.C. sigma RP-F TKA designed for improved performance: a matched-pair study. Orthopedics. 2006, 29: S49-S52.PubMed
6.
go back to reference Barink M, De Waal MM, Celada P, Vena P, Van Kampen A, Verdonschot N: A mechanical comparison of high-flexion and conventional total knee arthroplasty. Proc Inst Mech Eng H. 2008, 222: 297-307.CrossRefPubMed Barink M, De Waal MM, Celada P, Vena P, Van Kampen A, Verdonschot N: A mechanical comparison of high-flexion and conventional total knee arthroplasty. Proc Inst Mech Eng H. 2008, 222: 297-307.CrossRefPubMed
7.
go back to reference Kim YH, Sohn KS, Kim JS: Range of motion of standard and high-flexion posterior stabilized total knee prostheses: a prospective, randomized study. J Bone Joint Surg Am. 2005, 87: 1470-1475. 10.2106/JBJS.D.02707.CrossRefPubMed Kim YH, Sohn KS, Kim JS: Range of motion of standard and high-flexion posterior stabilized total knee prostheses: a prospective, randomized study. J Bone Joint Surg Am. 2005, 87: 1470-1475. 10.2106/JBJS.D.02707.CrossRefPubMed
8.
go back to reference Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM: In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech. 2005, 38: 277-284. 10.1016/j.jbiomech.2004.02.027.CrossRefPubMed Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM: In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech. 2005, 38: 277-284. 10.1016/j.jbiomech.2004.02.027.CrossRefPubMed
9.
go back to reference Bin SI, Nam TS: Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007, 15: 350-355. 10.1007/s00167-006-0202-y.CrossRefPubMed Bin SI, Nam TS: Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007, 15: 350-355. 10.1007/s00167-006-0202-y.CrossRefPubMed
10.
go back to reference Huang HT, Su JY, Wang GJ: The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty. 2005, 20: 674-679. 10.1016/j.arth.2004.09.053.CrossRefPubMed Huang HT, Su JY, Wang GJ: The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty. 2005, 20: 674-679. 10.1016/j.arth.2004.09.053.CrossRefPubMed
11.
go back to reference Laskin RS: The effect of a high-flex implant on postoperative flexion after primary total knee arthroplasty. Orthopedics. 2007, 30: 86-88.PubMed Laskin RS: The effect of a high-flex implant on postoperative flexion after primary total knee arthroplasty. Orthopedics. 2007, 30: 86-88.PubMed
12.
go back to reference Sharma A, Komistek RD, Scuderi GR, Cates HE: High-flexion TKA designs: what are their in vivo contact mechanics?. Clin Orthop Relat Res. 2007, 464: 117-126.PubMed Sharma A, Komistek RD, Scuderi GR, Cates HE: High-flexion TKA designs: what are their in vivo contact mechanics?. Clin Orthop Relat Res. 2007, 464: 117-126.PubMed
13.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN: Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989, 13-14. Insall JN, Dorr LD, Scott RD, Scott WN: Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989, 13-14.
14.
go back to reference Jung WH, Jeong JH, Ha YC, Lee YK, Koo KH: High early failure rate of the Columbus posterior stabilized high-flexion knee prosthesis. Clin Orthop Relat Res. 2012, 470: 1472-1481. 10.1007/s11999-011-2202-6.CrossRefPubMed Jung WH, Jeong JH, Ha YC, Lee YK, Koo KH: High early failure rate of the Columbus posterior stabilized high-flexion knee prosthesis. Clin Orthop Relat Res. 2012, 470: 1472-1481. 10.1007/s11999-011-2202-6.CrossRefPubMed
15.
go back to reference Bonner TJ, Eardley WG, Patterson P, Gregg PJ: The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg (Br). 2011, 93: 1217-1222.CrossRef Bonner TJ, Eardley WG, Patterson P, Gregg PJ: The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg (Br). 2011, 93: 1217-1222.CrossRef
16.
go back to reference Ritter MA, Berend ME, Harty LD, Davis KE, Meding JB, Keating EM: Predicting range of motion after revision total knee arthroplasty: clustering and log-linear regression analyses. J Arthroplasty. 2004, 19: 338-343. 10.1016/j.arth.2003.11.001.CrossRefPubMed Ritter MA, Berend ME, Harty LD, Davis KE, Meding JB, Keating EM: Predicting range of motion after revision total knee arthroplasty: clustering and log-linear regression analyses. J Arthroplasty. 2004, 19: 338-343. 10.1016/j.arth.2003.11.001.CrossRefPubMed
17.
go back to reference Seo JG, Moon YW, Lim JS, Park SJ, Kim SM: Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis. Knee Surg Sports Traumatol Arthrosc. 2012, 20: 538-545. 10.1007/s00167-011-1597-7.CrossRefPubMed Seo JG, Moon YW, Lim JS, Park SJ, Kim SM: Mechanical axis-derived femoral component rotation in extramedullary total knee arthroplasty: a comparison between femoral transverse axis and transepicondylar axis. Knee Surg Sports Traumatol Arthrosc. 2012, 20: 538-545. 10.1007/s00167-011-1597-7.CrossRefPubMed
18.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW: Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988, 15: 1833-1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW: Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988, 15: 1833-1840.PubMed
19.
go back to reference Gogia PP, Braatz JH, Rose SJ, Norton BJ: Reliability and validity of goniometric measurements at the knee. Phys Ther. 1987, 67: 192-195.PubMed Gogia PP, Braatz JH, Rose SJ, Norton BJ: Reliability and validity of goniometric measurements at the knee. Phys Ther. 1987, 67: 192-195.PubMed
20.
go back to reference Sultan PG, Most E, Schule S, Li G, Rubash HE: Optimizing flexion after total knee arthroplasty: advances in prosthetic design. Clin Orthop Relat Res. 2003, ᅟ: 167-173.CrossRef Sultan PG, Most E, Schule S, Li G, Rubash HE: Optimizing flexion after total knee arthroplasty: advances in prosthetic design. Clin Orthop Relat Res. 2003, ᅟ: 167-173.CrossRef
21.
go back to reference Han HS, Kang SB, Yoon KS: High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg (Br). 2007, 89: 1457-1461.CrossRef Han HS, Kang SB, Yoon KS: High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg (Br). 2007, 89: 1457-1461.CrossRef
22.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A: Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg (Br). 2002, 84: 50-53. 10.1302/0301-620X.84B1.12432.CrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A: Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg (Br). 2002, 84: 50-53. 10.1302/0301-620X.84B1.12432.CrossRef
23.
go back to reference Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD: Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?. Clin Orthop Relat Res. 2010, 468: 57-63. 10.1007/s11999-009-1119-9.CrossRefPubMed Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD: Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?. Clin Orthop Relat Res. 2010, 468: 57-63. 10.1007/s11999-009-1119-9.CrossRefPubMed
24.
go back to reference Dahm DL, Barnes SA, Harrington JR, Sayeed SA, Berry DJ: Patient-reported activity level after total knee arthroplasty. J Arthroplasty. 2008, 23: 401-407. 10.1016/j.arth.2007.05.051.CrossRefPubMed Dahm DL, Barnes SA, Harrington JR, Sayeed SA, Berry DJ: Patient-reported activity level after total knee arthroplasty. J Arthroplasty. 2008, 23: 401-407. 10.1016/j.arth.2007.05.051.CrossRefPubMed
25.
go back to reference Noble PC, Conditt MA, Cook KF, Mathis KB: The John Insall Award: patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res. 2006, 452: 35-43.CrossRefPubMed Noble PC, Conditt MA, Cook KF, Mathis KB: The John Insall Award: patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res. 2006, 452: 35-43.CrossRefPubMed
26.
go back to reference Delp SL, Kocmond JH, Stern SH: Tradeoffs between motion and stability in posterior substituting knee arthroplasty design. J Biomech. 1995, 28: 1155-1166. 10.1016/0021-9290(94)00172-Z.CrossRefPubMed Delp SL, Kocmond JH, Stern SH: Tradeoffs between motion and stability in posterior substituting knee arthroplasty design. J Biomech. 1995, 28: 1155-1166. 10.1016/0021-9290(94)00172-Z.CrossRefPubMed
27.
go back to reference Arnout N, Vandenneucker H, Bellemans J: Posterior dislocation in total knee replacement: a price for deep flexion?. Knee Surg Sports Traumatol Arthrosc. 2011, 19: 911-913. 10.1007/s00167-010-1258-2.CrossRefPubMed Arnout N, Vandenneucker H, Bellemans J: Posterior dislocation in total knee replacement: a price for deep flexion?. Knee Surg Sports Traumatol Arthrosc. 2011, 19: 911-913. 10.1007/s00167-010-1258-2.CrossRefPubMed
28.
go back to reference Ryu J, Saito S, Yamamoto K, Sano S: Factors influencing the postoperative range of motion in total knee arthroplasty. Bull Hosp Jt Dis. 1993, 53: 35-40.PubMed Ryu J, Saito S, Yamamoto K, Sano S: Factors influencing the postoperative range of motion in total knee arthroplasty. Bull Hosp Jt Dis. 1993, 53: 35-40.PubMed
Metadata
Title
Design modifications of high-flexion TKA do not improve short term clinical and radiographic outcomes
Authors
Jai Gon Seo
Young-Wan Moon
Moon Jong Chang
Byung Chul Jo
Yong Beom Park
Deuk Soo Lim
Byung Hoon Lee
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-433

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue