Skip to main content
Top
Published in: BMC Oral Health 1/2021

Open Access 01-12-2021 | Denture | Research

Prosthetic complications of fixed dental prostheses supported by locking-taper implants: a retrospective study with a mean follow-up of 5 years

Authors: Wen mo Gao, Wei Geng, Chen chen Luo

Published in: BMC Oral Health | Issue 1/2021

Login to get access

Abstract

Background

Restoration with locking-taper implants is a widely used methodology. However, conical connection systems such as locking-taper implant systems have rarely been examined. This study provides a retrospective investigation of locking-taper fixed restorations, mainly focusing on prosthetic complications.

Methods

Patients undergo treatment with conical connected implants from 2008 to 2010 were examined. Preparation of the implant sites was performed according to the standard procedures for the Bicon system. Bone healing took over 6 months, and the prosthetic procedure was initiated thereafter. Integrated abutment crowns or gold porcelain crowns were used, and the prosthesis type was a single crown or a fixed dental prosthesis. Once the crown was in place, its occlusion was thoroughly checked and adjusted, and then the crown was glazed or finely polished. The Kaplan–Meier method was used to calculate the cumulative complication-free rates for 5 and 10 years. Additionally, a Cox regression model was used to identify the factors that independently influenced the results. Implant survival and marginal bone loss were also investigated.

Results

A total of 392 patients who underwent 541 implants and 434 locking taper implant-based restorations from 2008 to 2010 were examined. The overall 5-year cumulative complication-free rate was 83.34%. The most common prosthetic complication was veneer chipping, with a frequency of 67.53%. According to the Cox regression model, the complication-free rate of integrated abutment crowns was significantly higher than that of gold porcelain crowns, that of molar regions was significantly higher than that of premolar regions, and that of females was significantly higher than that of males. Only three implant failures happened, and the mean marginal bone loss values at 1- year, 5-years and 10- years were 0.25 mm (95% CI ± 0.12), 0.40 mm (95% CI ± 0.03) and 0.51 mm (95% CI ± 0.05), respectively.

Conclusion

Veneer chipping was the most common complication with locking-taper implant-supported fixed restorations. The incidence of complications for IACs is significantly higher than that for GPCs. Age, location, and prosthesis type are not determinants of prosthetic complications. Besides, the long-term clinical effect of locking-taper implant can meet the clinical needs. The bone tissue level around the implant can maintain long-term stability.
Literature
1.
go back to reference Germana De Villa Camargos D, MS1/Célio Jesus do Prado, DDS, MS, PhD2/Flavio Domingues das Neves, DDS, MS, PhD2/Ivete Aparecida de Mattias Sartori, DDS, MS, PhD3: Clinical outcomes of single dental implants with external connections: results after 2 to 13 years. The International Journal of Oral & Maxillofacial Implants 2012, 27. Germana De Villa Camargos D, MS1/Célio Jesus do Prado, DDS, MS, PhD2/Flavio Domingues das Neves, DDS, MS, PhD2/Ivete Aparecida de Mattias Sartori, DDS, MS, PhD3: Clinical outcomes of single dental implants with external connections: results after 2 to 13 years. The International Journal of Oral & Maxillofacial Implants 2012, 27.
2.
go back to reference Bragger U, Karoussis I, Persson R, Pjetursson B, Salvi G, Lang N. Technical and biological complications/failures with single crowns and fixed partial dentures on implants: a 10-year prospective cohort study. Clin Oral Implant Res. 2005;16(3):326–34.CrossRef Bragger U, Karoussis I, Persson R, Pjetursson B, Salvi G, Lang N. Technical and biological complications/failures with single crowns and fixed partial dentures on implants: a 10-year prospective cohort study. Clin Oral Implant Res. 2005;16(3):326–34.CrossRef
3.
go back to reference Sadid-Zadeh R, Kutkut A, Kim H. Prosthetic failure in implant dentistry. Dent Clin N Am. 2015;59(1):195–214.CrossRef Sadid-Zadeh R, Kutkut A, Kim H. Prosthetic failure in implant dentistry. Dent Clin N Am. 2015;59(1):195–214.CrossRef
4.
go back to reference Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implant Res. 2008;19(2):119–30.CrossRef Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implant Res. 2008;19(2):119–30.CrossRef
5.
go back to reference Schmitt CM, Nogueira-Filho G, Tenenbaum HC, Lai JY, Brito C, Doring H, Nonhoff J. Performance of conical abutment (Morse taper) connection implants: a systematic review. J Biomed Mater Res A. 2014;102(2):552–74.CrossRef Schmitt CM, Nogueira-Filho G, Tenenbaum HC, Lai JY, Brito C, Doring H, Nonhoff J. Performance of conical abutment (Morse taper) connection implants: a systematic review. J Biomed Mater Res A. 2014;102(2):552–74.CrossRef
6.
go back to reference Tallarico M, Canullo L, Caneva M, Ozcan M. Microbial colonization at the implant-abutment interface and its possible influence on periimplantitis: a systematic review and meta-analysis. J Prosthodont Res. 2017;61(3):233–41.CrossRef Tallarico M, Canullo L, Caneva M, Ozcan M. Microbial colonization at the implant-abutment interface and its possible influence on periimplantitis: a systematic review and meta-analysis. J Prosthodont Res. 2017;61(3):233–41.CrossRef
7.
go back to reference Yuya SDC. Implant-abutment connections: a review of biologic consequences and peri-implantitis implications. Int J Oral Maxillofac Implants. 2017;32(6):1296–307.CrossRef Yuya SDC. Implant-abutment connections: a review of biologic consequences and peri-implantitis implications. Int J Oral Maxillofac Implants. 2017;32(6):1296–307.CrossRef
8.
go back to reference Sannino G, Barlattani A. Mechanical evaluation of an implant-abutment self-locking taper connection: finite element analysis and experimental tests. Int J Oral Maxillofac Implants. 2013;28(1):e17-26.CrossRef Sannino G, Barlattani A. Mechanical evaluation of an implant-abutment self-locking taper connection: finite element analysis and experimental tests. Int J Oral Maxillofac Implants. 2013;28(1):e17-26.CrossRef
9.
go back to reference Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999;81(2):159.CrossRef Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999;81(2):159.CrossRef
10.
go back to reference Carlo Mangano M, Bartolucci G. Single tooth replacement by Morse taper connection implants: a retrospective study of 80 implants. Int J Oral Maxillofac Implants. 2001;16:66. Carlo Mangano M, Bartolucci G. Single tooth replacement by Morse taper connection implants: a retrospective study of 80 implants. Int J Oral Maxillofac Implants. 2001;16:66.
11.
go back to reference Dibart S, Su MF, Skobe Z. In vitro evaluation of the implant-abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants. 2005;20:732–7.PubMed Dibart S, Su MF, Skobe Z. In vitro evaluation of the implant-abutment bacterial seal: the locking taper system. Int J Oral Maxillofac Implants. 2005;20:732–7.PubMed
12.
go back to reference Norton M. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res. 2010;8(4):66. Norton M. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res. 2010;8(4):66.
13.
go back to reference Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implant Res. 2012;23(Suppl 6):2–21.CrossRef Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implant Res. 2012;23(Suppl 6):2–21.CrossRef
14.
go back to reference Romeo E, Storelli S. Systematic review of the survival rate and the biological, technical, and aesthetic complications of fixed dental prostheses with cantilevers on implants reported in longitudinal studies with a mean of 5 years follow-up. Clin Oral Implant Res. 2012;23(Suppl 6):39–49.CrossRef Romeo E, Storelli S. Systematic review of the survival rate and the biological, technical, and aesthetic complications of fixed dental prostheses with cantilevers on implants reported in longitudinal studies with a mean of 5 years follow-up. Clin Oral Implant Res. 2012;23(Suppl 6):39–49.CrossRef
15.
go back to reference Mangano C, Iaculli F, Piattelli A, Mangano F. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10–20 years of follow-up. Clin Oral Implant Res. 2015;26(10):1229–36.CrossRef Mangano C, Iaculli F, Piattelli A, Mangano F. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10–20 years of follow-up. Clin Oral Implant Res. 2015;26(10):1229–36.CrossRef
16.
go back to reference Mangano F, Macchi A, Caprioglio A, Sammons RL, Piattelli A, Mangano C. Survival and complication rates of fixed restorations supported by locking-taper implants: a prospective study with 1 to 10 years of follow-up. J Prosthodont. 2014;23(6):434–44.CrossRef Mangano F, Macchi A, Caprioglio A, Sammons RL, Piattelli A, Mangano C. Survival and complication rates of fixed restorations supported by locking-taper implants: a prospective study with 1 to 10 years of follow-up. J Prosthodont. 2014;23(6):434–44.CrossRef
17.
go back to reference Rosenthal L, Pescatore C. A new system for posterior restorations: a combination of ceramic optimized polymer and fiber-reinforced composite. Pract Periodont Aesth Dent. 1997;9:66. Rosenthal L, Pescatore C. A new system for posterior restorations: a combination of ceramic optimized polymer and fiber-reinforced composite. Pract Periodont Aesth Dent. 1997;9:66.
18.
go back to reference Panos Papaspyridakos D, Chen C-J, Chuang S-K, Weber H-P, Gallucci O. A systematic review of biologic and technical complications with fixed implant rehabilitations for edentulous patients. Int J Oral Maxillofac Implants. 2012;66:27. Panos Papaspyridakos D, Chen C-J, Chuang S-K, Weber H-P, Gallucci O. A systematic review of biologic and technical complications with fixed implant rehabilitations for edentulous patients. Int J Oral Maxillofac Implants. 2012;66:27.
19.
go back to reference Wittneben JG, Salvi GE, Bürgin W, Hicklin S, Brägger U. Complication and failure rates with implant-supported fixed dental prostheses and single crowns: a 10-year retrospective study. Clin Implant Dent Relat Res. 2014;16:66.CrossRef Wittneben JG, Salvi GE, Bürgin W, Hicklin S, Brägger U. Complication and failure rates with implant-supported fixed dental prostheses and single crowns: a 10-year retrospective study. Clin Implant Dent Relat Res. 2014;16:66.CrossRef
20.
go back to reference Mangano F, Lucchina AG, Brucoli M, Migliario M, Mortellaro C, Mangano C. Prosthetic complications affecting single-tooth Morse-taper connection implants. J Craniofac Surg. 2018;29(8):2255–62.CrossRef Mangano F, Lucchina AG, Brucoli M, Migliario M, Mortellaro C, Mangano C. Prosthetic complications affecting single-tooth Morse-taper connection implants. J Craniofac Surg. 2018;29(8):2255–62.CrossRef
21.
go back to reference Mangano F, Colombo M, Mangano C. Clinical evaluation of 762 single-tooth, locking-taper implants: a prospective study with 1- to 12-years of follow-up. J Dent Oral Care Med. 2016;6:66. Mangano F, Colombo M, Mangano C. Clinical evaluation of 762 single-tooth, locking-taper implants: a prospective study with 1- to 12-years of follow-up. J Dent Oral Care Med. 2016;6:66.
22.
go back to reference Javier Ventura EJ-C, Romero J, Francisco F. Tooth fractures in fixed full-arch implant-supported acrylic resin prostheses: a retrospective clinical study. Int J Prosthodont. 2016;161:66. Javier Ventura EJ-C, Romero J, Francisco F. Tooth fractures in fixed full-arch implant-supported acrylic resin prostheses: a retrospective clinical study. Int J Prosthodont. 2016;161:66.
23.
go back to reference Bozini T, Tzanas K, Garefis P. A meta-analysis of prosthodontic complication rates of implant-supported fixed dental prostheses in edentulous patients after an observation period of at least 5 years. Int J Oral Maxillofac Implants. 2011;26:66. Bozini T, Tzanas K, Garefis P. A meta-analysis of prosthodontic complication rates of implant-supported fixed dental prostheses in edentulous patients after an observation period of at least 5 years. Int J Oral Maxillofac Implants. 2011;26:66.
24.
go back to reference Priest G, Smith J, Wilson MG. Implant survival and prosthetic complications of mandibular metal-acrylic resin implant complete fixed dental prostheses. J Prosthet Dent. 2014;111(6):466–75.CrossRef Priest G, Smith J, Wilson MG. Implant survival and prosthetic complications of mandibular metal-acrylic resin implant complete fixed dental prostheses. J Prosthet Dent. 2014;111(6):466–75.CrossRef
25.
go back to reference Weng D, Nagata MJ, Bell M, Bosco AF, de Melo LG, Richter EJ: Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Clin Oral Implants Res. 2008, 19(11):1141–47. Weng D, Nagata MJ, Bell M, Bosco AF, de Melo LG, Richter EJ: Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs. Clin Oral Implants Res. 2008, 19(11):1141–47.
26.
go back to reference Todescan FF, Pustiglioni FE, Imbronito AV, Albrektsson T, Gioso M. Influence of the Microgap in the Peri-implant hard and soft tissues: a histomorphometric study in dogs. Int J Oral Maxillofac Implants. 2002;17(4):66. Todescan FF, Pustiglioni FE, Imbronito AV, Albrektsson T, Gioso M. Influence of the Microgap in the Peri-implant hard and soft tissues: a histomorphometric study in dogs. Int J Oral Maxillofac Implants. 2002;17(4):66.
27.
go back to reference Aglietta M, Siciliano VI, Zwahlen M, Bragger U, Pjetursson BE, Lang NP, Salvi GE. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years. Clin Oral Implant Res. 2009;20(5):441–51.CrossRef Aglietta M, Siciliano VI, Zwahlen M, Bragger U, Pjetursson BE, Lang NP, Salvi GE. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years. Clin Oral Implant Res. 2009;20(5):441–51.CrossRef
28.
go back to reference Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDP s) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23:22–38.CrossRef Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDP s) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23:22–38.CrossRef
29.
go back to reference Coelho PG, Sudack P, Suzuki M, Kurtz KS, Romanos GE, Silva NR. In vitro evaluation of the implant abutment connection sealing capability of different implant systems. J Oral Rehabil. 2008;35(12):917–24.CrossRef Coelho PG, Sudack P, Suzuki M, Kurtz KS, Romanos GE, Silva NR. In vitro evaluation of the implant abutment connection sealing capability of different implant systems. J Oral Rehabil. 2008;35(12):917–24.CrossRef
30.
go back to reference Krejci I, Lutz F, Gautschi L. Wear and marginal adaptation of composite resin inlays. J Prosth Dent. 1994;72(3):233–44.CrossRef Krejci I, Lutz F, Gautschi L. Wear and marginal adaptation of composite resin inlays. J Prosth Dent. 1994;72(3):233–44.CrossRef
31.
go back to reference Att ABSA-AW. Effect of prosthetic material on the outcome of dental implants supporting implant-supported dentures: a meta analysis. Clin Oral Implants Res. 2017;28:66.CrossRef Att ABSA-AW. Effect of prosthetic material on the outcome of dental implants supporting implant-supported dentures: a meta analysis. Clin Oral Implants Res. 2017;28:66.CrossRef
32.
go back to reference McLaren EARR, Devaud V. Considerations in the use of polymer and fiber-based indirect restorative materials. Pract Periodontics Aesthet Dent. 1999;11(4):66. McLaren EARR, Devaud V. Considerations in the use of polymer and fiber-based indirect restorative materials. Pract Periodontics Aesthet Dent. 1999;11(4):66.
33.
go back to reference Sun Ying WZ, Wang B. The influence of repeated firings on the remained porcelain rate. J Pract Stomatol. 2002;18:66. Sun Ying WZ, Wang B. The influence of repeated firings on the remained porcelain rate. J Pract Stomatol. 2002;18:66.
34.
go back to reference Kopp C. Branemark osseointegration. Prognosis and treatment rationale. Dent Clin of N Am. 1989;33(4):66. Kopp C. Branemark osseointegration. Prognosis and treatment rationale. Dent Clin of N Am. 1989;33(4):66.
Metadata
Title
Prosthetic complications of fixed dental prostheses supported by locking-taper implants: a retrospective study with a mean follow-up of 5 years
Authors
Wen mo Gao
Wei Geng
Chen chen Luo
Publication date
01-12-2021
Publisher
BioMed Central
Keywords
Denture
Veneer
Published in
BMC Oral Health / Issue 1/2021
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-021-01843-2

Other articles of this Issue 1/2021

BMC Oral Health 1/2021 Go to the issue