Skip to main content
Top
Published in: European Radiology 8/2005

01-08-2005 | Musculoskeletal

CT volumetry of intravertebral cement after kyphoplasty. Comparison of polymethylmethacrylate and calcium phosphate in a 12-month follow-up

Authors: M. Libicher, M. Vetter, I. Wolf, G. Noeldge, C. Kasperk, I. Grafe, K. Da Fonseca, J. Hillmeier, P. J. Meeder, H. P. Meinzer, G. W. Kauffmann

Published in: European Radiology | Issue 8/2005

Login to get access

Abstract

This study was intended to measure the volume of intravertebral cement after balloon kyphoplasty with high resolution computed tomography (CT) and dedicated software. Volume changes of biocompatible calcium phosphate cement (CPC) were detected during a follow-up of 12 months. Measurements were compared with a control group of patients treated with polymethylmethacrylate (PMMA). Twenty-three vertebrae (14 CPC, 9 PMMA) of 12 patients were examined with CT using an identical imaging protocol. Dedicated software was used to quantify intravertebral cement volume in subvoxel resolution by analyzing each cement implant with a density-weighted algorithm. The mean volume reduction of CPC was 0.08 ml after 12 months, which corresponds to an absorption rate of 2 vol%. However, the difference did not reach significance level (P>0.05). The mean error estimate was 0.005 ml, indicating excellent precision of the method. CT volumetry appears a precise tool for measurement of intravertebral cement volume. CT volumetry offers the possibility of in vivo measurement of CPC resorption.
Literature
1.
go back to reference Cotten A, Dewatre F, Cortet B et al. (1996) Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 200:525–530PubMed Cotten A, Dewatre F, Cortet B et al. (1996) Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up. Radiology 200:525–530PubMed
2.
go back to reference Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 26:1511–1515CrossRefPubMed Garfin SR, Yuan HA, Reiley MA (2001) New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine 26:1511–1515CrossRefPubMed
3.
go back to reference Nussbaum DA, Gailloud P, Murphy K (2004) The chemistry of acrylic bone cements and implications for clinical use in image-guided therapy. J Vasc Interv Radiol 15:121–126 Nussbaum DA, Gailloud P, Murphy K (2004) The chemistry of acrylic bone cements and implications for clinical use in image-guided therapy. J Vasc Interv Radiol 15:121–126
4.
go back to reference Verlaan JJ, Oner FC, Slootweg PJ, Verbout AJ, Dhert WJ (2004) Histologic changes after vertebroplasty. J Bone Joint Surg [Am] 86-A:1230–1238 Verlaan JJ, Oner FC, Slootweg PJ, Verbout AJ, Dhert WJ (2004) Histologic changes after vertebroplasty. J Bone Joint Surg [Am] 86-A:1230–1238
5.
go back to reference Bai B, Jazrawi LM, Kummer FJ, Spivak JM (1999) The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine 24:1521–1526CrossRefPubMed Bai B, Jazrawi LM, Kummer FJ, Spivak JM (1999) The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine 24:1521–1526CrossRefPubMed
6.
go back to reference LeGeros RZ (2002) Properties of osteoconductive biomaterials: calcium phosphates. Clin Orthop 395:81–98 LeGeros RZ (2002) Properties of osteoconductive biomaterials: calcium phosphates. Clin Orthop 395:81–98
7.
go back to reference Weiss DD, Sachs MA, Woodard CR (2003) Calcium phosphate bone cements: a comprehensive review. J Long-Term Eff Med Implants 13:41–47 Weiss DD, Sachs MA, Woodard CR (2003) Calcium phosphate bone cements: a comprehensive review. J Long-Term Eff Med Implants 13:41–47
8.
go back to reference Lim TH, Brebach GT, Renner SM et al. (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297–1302 Lim TH, Brebach GT, Renner SM et al. (2002) Biomechanical evaluation of an injectable calcium phosphate cement for vertebroplasty. Spine 27:1297–1302
9.
go back to reference Ooms EM, Wolke JG, van der Waerden JP, Jansen JA (2002) Trabecular bone response to injectable calcium phosphate (Ca-P) cement. J Biomed Mater Res 61:9–18 Ooms EM, Wolke JG, van der Waerden JP, Jansen JA (2002) Trabecular bone response to injectable calcium phosphate (Ca-P) cement. J Biomed Mater Res 61:9–18
10.
go back to reference Lu J, Descamps M, Dejou J et al. (2002) The biodegradation mechanism of calcium phosphate biomaterials in bone. J Biomed Mater Res 63:408–412 Lu J, Descamps M, Dejou J et al. (2002) The biodegradation mechanism of calcium phosphate biomaterials in bone. J Biomed Mater Res 63:408–412
11.
go back to reference Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256PubMed Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 217:251–256PubMed
12.
go back to reference Wu Z, Chung HW, Wehrli FW (1994) A Bayesian approach to subvoxel tissue classification in NMR microscopic images of trabecular bone. Magn Reson Med 31:302–308 Wu Z, Chung HW, Wehrli FW (1994) A Bayesian approach to subvoxel tissue classification in NMR microscopic images of trabecular bone. Magn Reson Med 31:302–308
13.
go back to reference Vokurka EA, Herwadkar A, Thacker NA, Ramsden RT, Jackson A (2002) Using Bayesian tissue classification to improve the accuracy of vestibular schwannoma volume and growth measurement. Am J Neuroradiol 23:459–467 Vokurka EA, Herwadkar A, Thacker NA, Ramsden RT, Jackson A (2002) Using Bayesian tissue classification to improve the accuracy of vestibular schwannoma volume and growth measurement. Am J Neuroradiol 23:459–467
14.
go back to reference Laidlaw DH, Fleischer KW, Barr AH (1998) Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms. IEEE Trans Med Imag 17(1):74–86 Laidlaw DH, Fleischer KW, Barr AH (1998) Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms. IEEE Trans Med Imag 17(1):74–86
15.
go back to reference Lieberman IH, Dudeney S, Reinhardt MK, Bell G (2001) Initial outcome and efficacy of “kyphoplasty” in the treatment of painful osteoporotic vertebral compression fractures. Spine 26:1631–1638CrossRefPubMed Lieberman IH, Dudeney S, Reinhardt MK, Bell G (2001) Initial outcome and efficacy of “kyphoplasty” in the treatment of painful osteoporotic vertebral compression fractures. Spine 26:1631–1638CrossRefPubMed
16.
go back to reference Wolf I, Vetter M, Wegner I et al. (2004) The medical imaging interaction toolkit (MITK). In: Galloway RL (ed) SPIE medical imaging 2004. Visualization, image-guided procedures, and display. Bellingham, Washington, pp 16–27 Wolf I, Vetter M, Wegner I et al. (2004) The medical imaging interaction toolkit (MITK). In: Galloway RL (ed) SPIE medical imaging 2004. Visualization, image-guided procedures, and display. Bellingham, Washington, pp 16–27
17.
go back to reference Pokric M, Thacker N, Scott MLJ, Jackson A (2001) The importance of partial voluming in multi-dimensional medical image segmentation. Medical Image Computing and Computer-Assisted Intervention-MICCAI:1293 Pokric M, Thacker N, Scott MLJ, Jackson A (2001) The importance of partial voluming in multi-dimensional medical image segmentation. Medical Image Computing and Computer-Assisted Intervention-MICCAI:1293
18.
go back to reference Schmidt C, Priemel M, Kohler T et al. (2003) Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT). J Bone Miner Res 18:1486–1496 Schmidt C, Priemel M, Kohler T et al. (2003) Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT). J Bone Miner Res 18:1486–1496
19.
go back to reference Tomita S, Molloy S, Jasper LE, Abe M, Belkoff SM (2004) Biomechanical comparison of kyphoplasty with different bone cements. Spine 29:1203–1207 Tomita S, Molloy S, Jasper LE, Abe M, Belkoff SM (2004) Biomechanical comparison of kyphoplasty with different bone cements. Spine 29:1203–1207
20.
go back to reference Tomita S, Kin A, Yazu M, Abe M (2003) Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture. J Orthop Sci 8:192–197 Tomita S, Kin A, Yazu M, Abe M (2003) Biomechanical evaluation of kyphoplasty and vertebroplasty with calcium phosphate cement in a simulated osteoporotic compression fracture. J Orthop Sci 8:192–197
21.
go back to reference Hillmeier J, Meeder PJ, Nöldge G, Kock HJ, Da Fonseca K, Kasperk HC (2004) Balloon kyphoplasty of vertebral compression fractures with a new calcium phosphate cement. Orthopäde 33:31–39 (German) Hillmeier J, Meeder PJ, Nöldge G, Kock HJ, Da Fonseca K, Kasperk HC (2004) Balloon kyphoplasty of vertebral compression fractures with a new calcium phosphate cement. Orthopäde 33:31–39 (German)
22.
go back to reference Cunin G, Boissonnet H, Petite H, Blanchat C, Guillemin G (2000) Experimental vertebroplasty using osteoconductive granular material. Spine 25:1070–1076 Cunin G, Boissonnet H, Petite H, Blanchat C, Guillemin G (2000) Experimental vertebroplasty using osteoconductive granular material. Spine 25:1070–1076
23.
go back to reference Molloy S, Mathis JM, Belkoff SM (2003) The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty. Spine 28:1549–1554 Molloy S, Mathis JM, Belkoff SM (2003) The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty. Spine 28:1549–1554
24.
go back to reference Belkoff SM, Mathis JM, Jasper LE, Deramond H (2001) The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine 26:1537–1541PubMed Belkoff SM, Mathis JM, Jasper LE, Deramond H (2001) The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior. Spine 26:1537–1541PubMed
25.
go back to reference Liebschner MA, Rosenberg WS, Keaveny TM (2001) Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine 26:1547–1554 Liebschner MA, Rosenberg WS, Keaveny TM (2001) Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine 26:1547–1554
26.
go back to reference Mousavi P, Roth S, Finkelstein J, Cheung G, Whyne C (2003) Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae. J Neurosurg 99:56–59 Mousavi P, Roth S, Finkelstein J, Cheung G, Whyne C (2003) Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae. J Neurosurg 99:56–59
27.
go back to reference Wormanns D, Kohl G, Klotz E et al. (2004) Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 14:86–92CrossRefPubMed Wormanns D, Kohl G, Klotz E et al. (2004) Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 14:86–92CrossRefPubMed
28.
go back to reference Wasser K, Sinn HP, Fink C et al. (2003) Accuracy of tumor size measurement in breast cancer using MRI is influenced by histological regression induced by neoadjuvant chemotherapy. Eur Radiol 13:1213–1223 Wasser K, Sinn HP, Fink C et al. (2003) Accuracy of tumor size measurement in breast cancer using MRI is influenced by histological regression induced by neoadjuvant chemotherapy. Eur Radiol 13:1213–1223
29.
go back to reference Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378–2383CrossRefPubMed Fischbach F, Knollmann F, Griesshaber V, Freund T, Akkol E, Felix R (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378–2383CrossRefPubMed
30.
go back to reference Muller SD, Green SM, McCaskie AW (2002) The dynamic volume changes of polymerising polymethyl methacrylate bone cement. Acta Orthop Scand 73:684–687 Muller SD, Green SM, McCaskie AW (2002) The dynamic volume changes of polymerising polymethyl methacrylate bone cement. Acta Orthop Scand 73:684–687
31.
go back to reference Gilbert JL, Hasenwinkel JM, Wixson RL, Lautenschlager EP (2000) A theoretical and experimental analysis of polymerization shrinkage of bone cement: a potential major source of porosity. J Biomed Mater Res 52:210–218 Gilbert JL, Hasenwinkel JM, Wixson RL, Lautenschlager EP (2000) A theoretical and experimental analysis of polymerization shrinkage of bone cement: a potential major source of porosity. J Biomed Mater Res 52:210–218
Metadata
Title
CT volumetry of intravertebral cement after kyphoplasty. Comparison of polymethylmethacrylate and calcium phosphate in a 12-month follow-up
Authors
M. Libicher
M. Vetter
I. Wolf
G. Noeldge
C. Kasperk
I. Grafe
K. Da Fonseca
J. Hillmeier
P. J. Meeder
H. P. Meinzer
G. W. Kauffmann
Publication date
01-08-2005
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2005
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-005-2709-x

Other articles of this Issue 8/2005

European Radiology 8/2005 Go to the issue