Open Access 01-12-2021 | CT Angiography | Original Article

Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study

Authors: Juan Li, Yu-hong Wang, Fu-ling Zheng, Xin-yue Chen, Yun Lin, Cai-rong Zhu, Yi-fan Wu, Qiang Xu, Zheng-yu Jin, Hua-dan Xue

Published in: Insights into Imaging | Issue 1/2021

Login to get access

Abstract

Objectives

The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM.

Materials and methods

41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis.

Results

All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group.

Conclusion

Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM.
Literature
1.
go back to reference Hansen NJ (2016) Computed tomographic angiography of the abdominal aorta. Radiol Clin N Am 54:35–54CrossRef Hansen NJ (2016) Computed tomographic angiography of the abdominal aorta. Radiol Clin N Am 54:35–54CrossRef
2.
go back to reference Al-Hawary MM, Francis IR, Chari ST et al (2014) Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. Radiology 270:248–260CrossRef Al-Hawary MM, Francis IR, Chari ST et al (2014) Pancreatic ductal adenocarcinoma radiology reporting template: consensus statement of the Society of Abdominal Radiology and the American Pancreatic Association. Radiology 270:248–260CrossRef
3.
go back to reference Bush WH, Swanson DP (1991) Acute reactions to intravascular contrast media: types, risk factors, recognition, and specific treatment. AJR Am J Roentgenol 157:1153–1161CrossRef Bush WH, Swanson DP (1991) Acute reactions to intravascular contrast media: types, risk factors, recognition, and specific treatment. AJR Am J Roentgenol 157:1153–1161CrossRef
4.
go back to reference Ishigaki S, Itoh S, Satake H, Ota T, Ishigaki T (2007) CT depiction of small arteries in the pancreatic head: assessment using coronal reformatted images with 16-channel multislice CT. Abdom Imaging 32:215–223CrossRef Ishigaki S, Itoh S, Satake H, Ota T, Ishigaki T (2007) CT depiction of small arteries in the pancreatic head: assessment using coronal reformatted images with 16-channel multislice CT. Abdom Imaging 32:215–223CrossRef
6.
go back to reference Sugawara H, Suzuki S, Katada Y et al (2019) Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol 29:1400–1407CrossRef Sugawara H, Suzuki S, Katada Y et al (2019) Comparison of full-iodine conventional CT and half-iodine virtual monochromatic imaging: advantages and disadvantages. Eur Radiol 29:1400–1407CrossRef
7.
go back to reference Macchi V, Picardi EEE, Porzionato A et al (2017) Anatomo-radiological patterns of pancreatic vascularization, with surgical implications: clinical and anatomical study. Clin Anat 30:614–624CrossRef Macchi V, Picardi EEE, Porzionato A et al (2017) Anatomo-radiological patterns of pancreatic vascularization, with surgical implications: clinical and anatomical study. Clin Anat 30:614–624CrossRef
8.
go back to reference Ishizaki Y, Sugo H, Yoshimoto J, Imamura H, Kawasaki S (2010) Pancreatoduodenectomy with or without early ligation of the inferior pancreatoduodenal artery: comparison of intraoperative blood loss and short-term outcome. World J Surg 34:2939–2944CrossRef Ishizaki Y, Sugo H, Yoshimoto J, Imamura H, Kawasaki S (2010) Pancreatoduodenectomy with or without early ligation of the inferior pancreatoduodenal artery: comparison of intraoperative blood loss and short-term outcome. World J Surg 34:2939–2944CrossRef
9.
go back to reference Covantev S, Mazuruc N, Belic O (2019) The arterial supply of the distal part of the pancreas. Surg Res Pract 2019:5804047PubMedPubMedCentral Covantev S, Mazuruc N, Belic O (2019) The arterial supply of the distal part of the pancreas. Surg Res Pract 2019:5804047PubMedPubMedCentral
10.
go back to reference Nijhof WH, van der Vos CS, Anninga B, Jager GJ, Rutten MJ (2013) Reduction of contrast medium volume in abdominal aorta CTA: multiphasic injection technique versus a test bolus volume. Eur J Radiol 82:1373–1378CrossRef Nijhof WH, van der Vos CS, Anninga B, Jager GJ, Rutten MJ (2013) Reduction of contrast medium volume in abdominal aorta CTA: multiphasic injection technique versus a test bolus volume. Eur J Radiol 82:1373–1378CrossRef
11.
go back to reference Nijhof WH, Baltussen EJ, Kant IM, Jager GJ, Slump CH, Rutten MJ (2016) Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: assessment of image quality and radiation dose. Clin Radiol 71:64–73CrossRef Nijhof WH, Baltussen EJ, Kant IM, Jager GJ, Slump CH, Rutten MJ (2016) Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: assessment of image quality and radiation dose. Clin Radiol 71:64–73CrossRef
12.
go back to reference Seehofnerova A, Kok M, Mihl C et al (2015) Feasibility of low contrast media volume in CT angiography of the aorta. Eur J Radiol Open 2:58–65CrossRef Seehofnerova A, Kok M, Mihl C et al (2015) Feasibility of low contrast media volume in CT angiography of the aorta. Eur J Radiol Open 2:58–65CrossRef
13.
go back to reference Gutjahr R, Fletcher JG, Lee YS et al (2019) Individualized delay for abdominal computed tomography angiography bolus-tracking based on sequential monitoring: increased aortic contrast permits decreased injection rate and lower iodine dose. J Comput Assist Tomogr 43:612–618CrossRef Gutjahr R, Fletcher JG, Lee YS et al (2019) Individualized delay for abdominal computed tomography angiography bolus-tracking based on sequential monitoring: increased aortic contrast permits decreased injection rate and lower iodine dose. J Comput Assist Tomogr 43:612–618CrossRef
14.
go back to reference Nijhof WH, van der Vos CS, Anninga B, Stegehuis PL, Jager GJ, Rutten MJ (2013) Reduced contrast medium in abdominal aorta CTA using a multiphasic injection technique. Eur J Radiol 82:252–257CrossRef Nijhof WH, van der Vos CS, Anninga B, Stegehuis PL, Jager GJ, Rutten MJ (2013) Reduced contrast medium in abdominal aorta CTA using a multiphasic injection technique. Eur J Radiol 82:252–257CrossRef
15.
go back to reference Holalkere NS, Matthes K, Kalva SP, Brugge WR, Sahani DV (2011) 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model. Br J Radiol 84:221–228CrossRef Holalkere NS, Matthes K, Kalva SP, Brugge WR, Sahani DV (2011) 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model. Br J Radiol 84:221–228CrossRef
16.
go back to reference Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol 49:586–592CrossRef Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol 49:586–592CrossRef
17.
go back to reference Kanematsu M, Goshima S, Kawai N et al (2015) Low-iodine-load and low-tube-voltage CT angiographic imaging of the kidney by using bolus tracking with saline flushing. Radiology 275:832–840CrossRef Kanematsu M, Goshima S, Kawai N et al (2015) Low-iodine-load and low-tube-voltage CT angiographic imaging of the kidney by using bolus tracking with saline flushing. Radiology 275:832–840CrossRef
18.
go back to reference Shuman WP, Chan KT, Busey JM, Mitsumori LM, Koprowicz KM (2016) Dual-energy CT aortography with 50% reduced iodine dose versus single-energy CT aortography with standard iodine dose. Acad Radiol 23:611–618CrossRef Shuman WP, Chan KT, Busey JM, Mitsumori LM, Koprowicz KM (2016) Dual-energy CT aortography with 50% reduced iodine dose versus single-energy CT aortography with standard iodine dose. Acad Radiol 23:611–618CrossRef
19.
go back to reference Mileto A, Ramirez-Giraldo JC, Marin D et al (2014) Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced? AJR Am J Roentgenol 203:838–845CrossRef Mileto A, Ramirez-Giraldo JC, Marin D et al (2014) Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced? AJR Am J Roentgenol 203:838–845CrossRef
20.
go back to reference Macchi V, Tiengo C, Porzionato A et al (2014) Anatomical remodelling of the anterior abdominal wall arteries in obesity. Clin Hemorheol Microcirc 57:255–265CrossRef Macchi V, Tiengo C, Porzionato A et al (2014) Anatomical remodelling of the anterior abdominal wall arteries in obesity. Clin Hemorheol Microcirc 57:255–265CrossRef
22.
go back to reference Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRef Bae KT (2010) Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 256:32–61CrossRef
23.
go back to reference Hinzpeter R, Eberhard M, Gutjahr R et al (2019) CT Angiography of the aorta: contrast timing by using a fixed versus a patient-specific trigger delay. Radiology 291:531–538CrossRef Hinzpeter R, Eberhard M, Gutjahr R et al (2019) CT Angiography of the aorta: contrast timing by using a fixed versus a patient-specific trigger delay. Radiology 291:531–538CrossRef
24.
go back to reference Leithner D, Mahmoudi S, Wichmann JL et al (2018) Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 99:111–117CrossRef Leithner D, Mahmoudi S, Wichmann JL et al (2018) Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 99:111–117CrossRef
25.
go back to reference Martin SS, Wichmann JL, Weyer H et al (2017) Endoleaks after endovascular aortic aneurysm repair: improved detection with noise-optimized virtual monoenergetic dual-energy CT. Eur J Radiol 94:125–132CrossRef Martin SS, Wichmann JL, Weyer H et al (2017) Endoleaks after endovascular aortic aneurysm repair: improved detection with noise-optimized virtual monoenergetic dual-energy CT. Eur J Radiol 94:125–132CrossRef
26.
go back to reference Albrecht MH, Trommer J, Wichmann JL et al (2016) Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen. Invest Radiol 51:582–590CrossRef Albrecht MH, Trommer J, Wichmann JL et al (2016) Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen. Invest Radiol 51:582–590CrossRef
27.
go back to reference Wichmann JL, Gillott MR, De Cecco CN et al (2016) Dual-energy computed tomography angiography of the lower extremity runoff impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy. Invest Radiol 51:139–146CrossRef Wichmann JL, Gillott MR, De Cecco CN et al (2016) Dual-energy computed tomography angiography of the lower extremity runoff impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy. Invest Radiol 51:139–146CrossRef
28.
go back to reference Mangold S, De Cecco CN, Schoepf UJ et al (2016) A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography. Eur Radiol 26:4380–4389CrossRef Mangold S, De Cecco CN, Schoepf UJ et al (2016) A noise-optimized virtual monochromatic reconstruction algorithm improves stent visualization and diagnostic accuracy for detection of in-stent re-stenosis in lower extremity run-off CT angiography. Eur Radiol 26:4380–4389CrossRef
Metadata
Title
Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
Authors
Juan Li
Yu-hong Wang
Fu-ling Zheng
Xin-yue Chen
Yun Lin
Cai-rong Zhu
Yi-fan Wu
Qiang Xu
Zheng-yu Jin
Hua-dan Xue
Publication date
01-12-2021
Publisher
Springer International Publishing
Keyword
CT Angiography
Published in
Insights into Imaging / Issue 1/2021
Electronic ISSN: 1869-4101
DOI
https://doi.org/10.1186/s13244-021-01079-2

Other articles of this Issue 1/2021

Insights into Imaging 1/2021 Go to the issue