Abstract

To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.7mL/kg (n = 70); Group B, 0.6mL/kg (n = 70); Group C, 0.5mL/kg (n = 70). All patients were examined via a prospective ECG-triggered scan protocol within one heartbeat. A high level DLIR (DLIR-H) algorithm was used for image reconstruction with a thickness and interval of 0.625mm. The CT values of ascending aorta (AA), descending aorta (DA), three main coronary arteries, pulmonary artery (PA), and superior vena cava (SVC) were measured and analyzed for objective assessment. Two radiologists assessed the image quality and diagnostic confidence using a 5-point Likert scale. The CM doses were 46.81 ± 6.41mL, 41.96 ± 7.51mL and 34.65 ± 5.38mL for Group A, B and C, respectively. The objective assessments on AA, DA and the three main coronary arteries and the overall subjective scoring showed no significant difference among the three groups (all p > 0.05). The subjective assessment proved that excellent CCTA images can be obtained from the three different contrast media protocols. There were no significant differences in intracoronary attenuation values between the higher HR subgroup and the lower HR subgroup among three groups. CCTA reconstructed with DLIR could be realized with adequate enhancement in coronary arteries, excellent image quality and diagnostic confidence at low contrast dose of a 0.5mL/kg. The use of lower tube voltages may further reduce the contrast dose requirement.
Appendix
Available only for authorised users
Literature
1.
go back to reference Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, Prescott E, Storey RF, Deaton C, Cuisset T, Agewall S, Dickstein K, Edvardsen T, Escaned J, Gersh BJ, Svitil P, Gilard M, Hasdai D, Hatala R, Mahfoud F, Masip J, Muneretto C, Valgimigli M, Achenbach S, Bax JJ, Group ESCSD (2020) 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 41:407–477. https://doi.org/10.1093/eurheartj/ehz425CrossRefPubMed Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C, Prescott E, Storey RF, Deaton C, Cuisset T, Agewall S, Dickstein K, Edvardsen T, Escaned J, Gersh BJ, Svitil P, Gilard M, Hasdai D, Hatala R, Mahfoud F, Masip J, Muneretto C, Valgimigli M, Achenbach S, Bax JJ, Group ESCSD (2020) 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 41:407–477. https://​doi.​org/​10.​1093/​eurheartj/​ehz425CrossRefPubMed
2.
go back to reference Investigators S-H, Newby DE, Adamson PD, Berry C, Boon NA, Dweck MR, Flather M, Forbes J, Hunter A, Lewis S, MacLean S, Mills NL, Norrie J, Roditi G, Shah ASV, Timmis AD, van Beek EJR, Williams MC (2018) Coronary CT angiography and 5-year risk of myocardial infarction. N Engl J Med 379:924–933. https://doi.org/10.1056/NEJMoa1805971CrossRef Investigators S-H, Newby DE, Adamson PD, Berry C, Boon NA, Dweck MR, Flather M, Forbes J, Hunter A, Lewis S, MacLean S, Mills NL, Norrie J, Roditi G, Shah ASV, Timmis AD, van Beek EJR, Williams MC (2018) Coronary CT angiography and 5-year risk of myocardial infarction. N Engl J Med 379:924–933. https://​doi.​org/​10.​1056/​NEJMoa1805971CrossRef
6.
go back to reference Eng J, Wilson RF, Subramaniam RM, Zhang A, Suarez-Cuervo C, Turban S, Choi MJ, Sherrod C, Hutfless S, Iyoha EE, Bass EB (2016) Comparative effect of contrast media type on the incidence of contrast-induced nephropathy: a systematic review and meta-analysis. Ann Intern Med 164:417–424. https://doi.org/10.7326/M15-1402CrossRefPubMed Eng J, Wilson RF, Subramaniam RM, Zhang A, Suarez-Cuervo C, Turban S, Choi MJ, Sherrod C, Hutfless S, Iyoha EE, Bass EB (2016) Comparative effect of contrast media type on the incidence of contrast-induced nephropathy: a systematic review and meta-analysis. Ann Intern Med 164:417–424. https://​doi.​org/​10.​7326/​M15-1402CrossRefPubMed
7.
go back to reference Laville M, Juillard L (2010) Contrast-induced acute kidney injury: how should at-risk patients be identified and managed? J Nephrol 23:387–398PubMed Laville M, Juillard L (2010) Contrast-induced acute kidney injury: how should at-risk patients be identified and managed? J Nephrol 23:387–398PubMed
10.
13.
go back to reference Albrecht MH, Nance JW, Schoepf UJ, Jacobs BE, Bayer RR 2nd, Litwin SE, Reynolds MA, Otani K, Mangold S, Varga-Szemes A, De Santis D, Eid M, Apfaltrer G, Tesche C, Goeller M, Vogl TJ, De Cecco CN (2018) Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol. Eur Radiol 28:2134–2142. https://doi.org/10.1007/s00330-017-5150-zCrossRefPubMed Albrecht MH, Nance JW, Schoepf UJ, Jacobs BE, Bayer RR 2nd, Litwin SE, Reynolds MA, Otani K, Mangold S, Varga-Szemes A, De Santis D, Eid M, Apfaltrer G, Tesche C, Goeller M, Vogl TJ, De Cecco CN (2018) Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol. Eur Radiol 28:2134–2142. https://​doi.​org/​10.​1007/​s00330-017-5150-zCrossRefPubMed
18.
go back to reference Benz DC, Benetos G, Rampidis G, von Felten E, Bakula A, Sustar A, Kudura K, Messerli M, Fuchs TA, Gebhard C, Pazhenkottil AP, Kaufmann PA, Buechel RR (2020) Validation of deep-learning image reconstruction for coronary computed tomography angiography: impact on noise, image quality and diagnostic accuracy. J Cardiovasc Comput Tomogr 14:444–451. https://doi.org/10.1016/j.jcct.2020.01.002CrossRefPubMed Benz DC, Benetos G, Rampidis G, von Felten E, Bakula A, Sustar A, Kudura K, Messerli M, Fuchs TA, Gebhard C, Pazhenkottil AP, Kaufmann PA, Buechel RR (2020) Validation of deep-learning image reconstruction for coronary computed tomography angiography: impact on noise, image quality and diagnostic accuracy. J Cardiovasc Comput Tomogr 14:444–451. https://​doi.​org/​10.​1016/​j.​jcct.​2020.​01.​002CrossRefPubMed
21.
go back to reference Hong SH, Goo HW, Maeda E, Choo KS, Tsai IC, Asian Society of Cardiovascular Imaging Congenital Heart Disease Study G (2019) User-friendly vendor-specific guideline for pediatric cardiothoracic computed tomography provided by the asian society of cardiovascular imaging congenital heart disease study group: part 1. imaging techniques. Korean J Radiol 20:190–204. https://doi.org/10.3348/kjr.2018.0571CrossRefPubMed Hong SH, Goo HW, Maeda E, Choo KS, Tsai IC, Asian Society of Cardiovascular Imaging Congenital Heart Disease Study G (2019) User-friendly vendor-specific guideline for pediatric cardiothoracic computed tomography provided by the asian society of cardiovascular imaging congenital heart disease study group: part 1. imaging techniques. Korean J Radiol 20:190–204. https://​doi.​org/​10.​3348/​kjr.​2018.​0571CrossRefPubMed
25.
27.
29.
go back to reference Andreini D, Pontone G, Mushtaq S, Conte E, Perchinunno M, Guglielmo M, Volpato V, Annoni A, Baggiano A, Formenti A, Mancini ME, Beltrama V, Ditali V, Campari A, Fiorentini C, Bartorelli AL, Pepi M (2017) Atrial fibrillation: diagnostic accuracy of coronary CT angiography performed with a whole-heart 230-microm spatial resolution CT scanner. Radiology 284:676–684. https://doi.org/10.1148/radiol.2017161779CrossRefPubMed Andreini D, Pontone G, Mushtaq S, Conte E, Perchinunno M, Guglielmo M, Volpato V, Annoni A, Baggiano A, Formenti A, Mancini ME, Beltrama V, Ditali V, Campari A, Fiorentini C, Bartorelli AL, Pepi M (2017) Atrial fibrillation: diagnostic accuracy of coronary CT angiography performed with a whole-heart 230-microm spatial resolution CT scanner. Radiology 284:676–684. https://​doi.​org/​10.​1148/​radiol.​2017161779CrossRefPubMed
30.
go back to reference Cherukuri L, Birudaraju D, Kinninger A, Chaganti BT, Pidikiti S, Pozon RG, Pozon ACG, Lakshmanan S, Dahal S, Hamal S, Flores F, Christopher D, Andreini D, Pontone G, Conte E, Nakanishi R, O’Rourke R, Hamilton-Craig C, Nasir K, Roy SK, Mao SS, Budoff MJ (2021) Use of advanced CT technology to evaluate left atrial indices in patients with a high heart rate or with heart rate variability: the converge registry. J Nucl Med Technol 49:65–69. https://doi.org/10.2967/jnmt.120.253781CrossRefPubMed Cherukuri L, Birudaraju D, Kinninger A, Chaganti BT, Pidikiti S, Pozon RG, Pozon ACG, Lakshmanan S, Dahal S, Hamal S, Flores F, Christopher D, Andreini D, Pontone G, Conte E, Nakanishi R, O’Rourke R, Hamilton-Craig C, Nasir K, Roy SK, Mao SS, Budoff MJ (2021) Use of advanced CT technology to evaluate left atrial indices in patients with a high heart rate or with heart rate variability: the converge registry. J Nucl Med Technol 49:65–69. https://​doi.​org/​10.​2967/​jnmt.​120.​253781CrossRefPubMed
31.
Metadata
Title
Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography
Authors
Dian Yuan
Luotong Wang
Peijie Lyu
Yonggao Zhang
Jianbo Gao
Jie Liu
Publication date
09-05-2024
Publisher
Springer Netherlands
Keyword
CT Angiography
Published in
The International Journal of Cardiovascular Imaging
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-024-03113-y