Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2012

01-12-2012 | Knee

Conventional or navigated total knee arthroplasty affects sagittal component alignment

Authors: Ryo Sugama, Yukihide Minoda, Akio Kobayashi, Hiroyoshi Iwaki, Mitsuhiko Ikebuchi, Kunio Takaoka, Hiroaki Nakamura

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 12/2012

Login to get access

Abstract

Purpose

Navigation systems have recently been developed to achieve highly reliable prosthetic alignment in total knee arthroplasty (TKA). However, component alignment in the sagittal plane is less reliable than that in the coronal plane even when navigation systems are used. Previous reports examining men showed differences in targeted sagittal prosthetic alignments of TKA achieved using the conventional technique and various navigation systems. However, there have been few studies examining the use of this technique in women, who are the primary candidates for TKA.

Methods

Radiographs of the entire lower extremity were obtained from 20 elder women while standing and sagittal prosthetic alignments in TKA were planned using the conventional technique as well as three navigation approaches to establish reference frames, and the observations were compared.

Results

Sagittal alignments simulated using the radiographs for the conventional technique and navigation systems differed within a mean of 3.2° ± 1.7° (mean ± SD) to 6.3° ± 2.0°. The use of different reference points on the distal femoral condyles (insertion point of the intramedullary rod, center of the anteroposterior direction of the femoral condyles, and most distal point of the femoral condyles) for each navigation system resulted in differences in the sagittal plane up to 3.0° ± 1.5°. The use of navigation systems resulted in a more hyperextended position between the femoral and tibial components compared to that for the conventional technique.

Conclusions

Targeted sagittal prosthetic alignments of TKA achieved using the conventional technique and various navigation systems differed in elderly women. The use of different reference points on the distal femoral condyle for navigation systems resulted in different alignment in the sagittal plane. This study showed that alignment tendencies are similar in men and women.

Level of evidence

Prognostic studies, IV.
Literature
1.
go back to reference Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47PubMed
2.
go back to reference Biasca N, Wirth S, Bungartz M (2009) Mechanical accuracy of navigated minimally invasive total knee arthroplasty (MIS TKA). Knee 16:22–29PubMedCrossRef Biasca N, Wirth S, Bungartz M (2009) Mechanical accuracy of navigated minimally invasive total knee arthroplasty (MIS TKA). Knee 16:22–29PubMedCrossRef
3.
go back to reference Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88PubMedCrossRef Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88PubMedCrossRef
4.
go back to reference Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement: a controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Jt Surg Br 86:818–823CrossRef Chauhan SK, Clark GW, Lloyd S, Scott RG, Breidahl W, Sikorski JM (2004) Computer-assisted total knee replacement: a controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol). J Bone Jt Surg Br 86:818–823CrossRef
5.
go back to reference Cheng T, Zhao S, Peng X, Zhang X (2011) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-011-1588-8 Cheng T, Zhao S, Peng X, Zhang X (2011) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials? Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-011-1588-8
6.
go back to reference Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA (2005) Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Jt Surg Am 87:2702–2708CrossRef Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA (2005) Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Jt Surg Am 87:2702–2708CrossRef
7.
go back to reference Egol KA, Chang EY, Cvitkovic J, Kummer FJ, Koval KJ (2004) Mismatch of current intramedullary nails with the anterior bow of the femur. J Orthop Trauma 18:410–415PubMedCrossRef Egol KA, Chang EY, Cvitkovic J, Kummer FJ, Koval KJ (2004) Mismatch of current intramedullary nails with the anterior bow of the femur. J Orthop Trauma 18:410–415PubMedCrossRef
8.
9.
go back to reference Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19:904–910PubMedCrossRef Hasegawa M, Yoshida K, Wakabayashi H, Sudo A (2011) Minimally invasive total knee arthroplasty: comparison of jig-based technique versus computer navigation for clinical and alignment outcome. Knee Surg Sports Traumatol Arthrosc 19:904–910PubMedCrossRef
10.
go back to reference Ishiguchi T (2005) Radiation dose of CT. J Jpn Med Assoc 134:1732 Ishiguchi T (2005) Radiation dose of CT. J Jpn Med Assoc 134:1732
11.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Surg Br 73:709–714 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Surg Br 73:709–714
12.
go back to reference Jung YB, Lee HJ, Jung HJ, Song KS, Lee JS, Yang JJ (2009) Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:286–292PubMedCrossRef Jung YB, Lee HJ, Jung HJ, Song KS, Lee JS, Yang JJ (2009) Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 17:286–292PubMedCrossRef
13.
go back to reference Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomized study. J Bone Jt Surg Br 89:471–476CrossRef Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomized study. J Bone Jt Surg Br 89:471–476CrossRef
14.
go back to reference Li G, Papannagari R, Most E, Park SE, Johnson T, Tanamal L, Rubash HE (2005) Anterior tibial post impingement in a posterior stabilized total knee arthroplasty. J Orthop Res 23:536–541PubMedCrossRef Li G, Papannagari R, Most E, Park SE, Johnson T, Tanamal L, Rubash HE (2005) Anterior tibial post impingement in a posterior stabilized total knee arthroplasty. J Orthop Res 23:536–541PubMedCrossRef
15.
go back to reference Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89:236–243CrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty: three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89:236–243CrossRef
16.
go back to reference Matziolis G, Hube R, Perka C, Matziolis D (2011) Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-011-1704-9 Matziolis G, Hube R, Perka C, Matziolis D (2011) Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-011-1704-9
17.
go back to reference Minoda Y, Kobayashi A, Iwaki H, Sugama R, Iwakiri K, Kadoya Y, Ohashi H, Takaoka K (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442PubMedCrossRef Minoda Y, Kobayashi A, Iwaki H, Sugama R, Iwakiri K, Kadoya Y, Ohashi H, Takaoka K (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442PubMedCrossRef
18.
go back to reference Minoda Y, Kobayashi A, Iwaki H, Ohashi H, Takaoka K (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006PubMedCrossRef Minoda Y, Kobayashi A, Iwaki H, Ohashi H, Takaoka K (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006PubMedCrossRef
19.
go back to reference Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMedCrossRef Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426PubMedCrossRef
20.
go back to reference Sato T, Koga Y, Omori G (2004) Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty. J Arthroplasty 19:620–628PubMedCrossRef Sato T, Koga Y, Omori G (2004) Three-dimensional lower extremity alignment assessment system: application to evaluation of component position after total knee arthroplasty. J Arthroplasty 19:620–628PubMedCrossRef
21.
go back to reference Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support: a prospective, randomised study. J Bone Jt Surg Br 85:830–835 Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support: a prospective, randomised study. J Bone Jt Surg Br 85:830–835
22.
go back to reference Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184PubMedCrossRef Stulberg SD (2003) How accurate is current TKR instrumentation? Clin Orthop Relat Res 416:177–184PubMedCrossRef
23.
go back to reference Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Jt Surg Br 67:551–556 Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Jt Surg Br 67:551–556
24.
go back to reference Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43PubMed
25.
go back to reference Zhang GQ, Chen JY, Chai W, Liu M, Wang Y (2011) Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures: a randomized clinical trial. J Bone Jt Surg Am 93:1190–1196CrossRef Zhang GQ, Chen JY, Chai W, Liu M, Wang Y (2011) Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures: a randomized clinical trial. J Bone Jt Surg Am 93:1190–1196CrossRef
Metadata
Title
Conventional or navigated total knee arthroplasty affects sagittal component alignment
Authors
Ryo Sugama
Yukihide Minoda
Akio Kobayashi
Hiroyoshi Iwaki
Mitsuhiko Ikebuchi
Kunio Takaoka
Hiroaki Nakamura
Publication date
01-12-2012
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 12/2012
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-1889-6

Other articles of this Issue 12/2012

Knee Surgery, Sports Traumatology, Arthroscopy 12/2012 Go to the issue