Skip to main content
Top
Published in: Journal of Digital Imaging 4/2008

01-12-2008

Computerized Analysis of Digital Subtraction Angiography: A Tool for Quantitative In-vivo Vascular Imaging

Authors: George C. Kagadis, Panagiota Spyridonos, Dimitris Karnabatidis, Athanassios Diamantopoulos, Emmanouil Athanasiadis, Antonis Daskalakis, Konstantinos Katsanos, Dionisios Cavouras, Dimitris Mihailidis, Dimitris Siablis, George C. Nikiforidis

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2008

Login to get access

Abstract

The purpose of our study was to develop a user-independent computerized tool for the automated segmentation and quantitative assessment of in vivo-acquired digital subtraction angiography (DSA) images. Vessel enhancement was accomplished based on the concept of image structural tensor. The developed software was tested on a series of DSA images acquired from one animal and two human angiogenesis models. Its performance was evaluated against manually segmented images. A receiver’s operating characteristic curve was obtained for every image with regard to the different percentages of the image histogram. The area under the mean curve was 0.89 for the experimental angiogenesis model and 0.76 and 0.86 for the two clinical angiogenesis models. The coordinates of the operating point were 8.3% false positive rate and 92.8% true positive rate for the experimental model. Correspondingly for clinical angiogenesis models, the coordinates were 8.6% false positive rate and 89.2% true positive rate and 9.8% false positive rate and 93.8% true positive rate, respectively. A new user-friendly tool for the analysis of vascular networks in DSA images was developed that can be easily used in either experimental or clinical studies. Its main characteristics are robustness and fast and automatic execution.
Appendix
Available only for authorised users
Literature
3.
go back to reference Fischer C, Schneider M, Carmeliet P: Principles and therapeutic implications of angiogenesis, vasculogenesis and arteriogenesis. Handb Exp Pharmacol 176(Pt 2):157–212, 2006PubMedCrossRef Fischer C, Schneider M, Carmeliet P: Principles and therapeutic implications of angiogenesis, vasculogenesis and arteriogenesis. Handb Exp Pharmacol 176(Pt 2):157–212, 2006PubMedCrossRef
4.
go back to reference Blatt RJ, Clark AN, Courtney J, Tully C, Tucker AL: Automated quantitative analysis of angiogenesis in the rat aorta model using Image-Pro Plus 4.1. Comput Methods Programs Biomed 75(1):75–79, 2004PubMedCrossRef Blatt RJ, Clark AN, Courtney J, Tully C, Tucker AL: Automated quantitative analysis of angiogenesis in the rat aorta model using Image-Pro Plus 4.1. Comput Methods Programs Biomed 75(1):75–79, 2004PubMedCrossRef
5.
go back to reference Hasan J, Shnyder SD, Bibby M, Double JA, Bicknel R, Jayson GC: Quantitative angiogenesis assays in vivo—a review. Angiogenesis 7(1):1–16, 2004PubMedCrossRef Hasan J, Shnyder SD, Bibby M, Double JA, Bicknel R, Jayson GC: Quantitative angiogenesis assays in vivo—a review. Angiogenesis 7(1):1–16, 2004PubMedCrossRef
6.
go back to reference McDonald DM, Choyke PL: Imaging of angiogenesis: from microscope to clinic. Nat Med 9(6):713–725, 2003PubMedCrossRef McDonald DM, Choyke PL: Imaging of angiogenesis: from microscope to clinic. Nat Med 9(6):713–725, 2003PubMedCrossRef
7.
go back to reference Frangi AF, Niessen WJ, Vincken KL, Viergever MA: Multiscale vessel enhancement filtering. In: Wells WM III, Colchester ACF, Delp SL Eds. Medical Image Computing and Computer-Assisted Intervention Lecture Notes in Computer Science. New York: Springer-Verlag, 1998, pp 130–137 Frangi AF, Niessen WJ, Vincken KL, Viergever MA: Multiscale vessel enhancement filtering. In: Wells WM III, Colchester ACF, Delp SL Eds. Medical Image Computing and Computer-Assisted Intervention Lecture Notes in Computer Science. New York: Springer-Verlag, 1998, pp 130–137
8.
go back to reference Manniesing R, Viergever MA, Niessen WJ: Vessel enhancing diffusion. A scale space representation of vessel structures. Med Image Anal 10(6):815–825, 2006PubMedCrossRef Manniesing R, Viergever MA, Niessen WJ: Vessel enhancing diffusion. A scale space representation of vessel structures. Med Image Anal 10(6):815–825, 2006PubMedCrossRef
9.
go back to reference Kirbas C, Quek F: A review of vessel extraction techniques and algorithms. ACM Comput Surv 36(2):81–121, 2004CrossRef Kirbas C, Quek F: A review of vessel extraction techniques and algorithms. ACM Comput Surv 36(2):81–121, 2004CrossRef
10.
go back to reference Meijering E, Niessen W, Weickert J, Viergever M: Evaluation of diffusion techniques for improved vessel visualization and quantification in three-dimensional rotational angiography. In: Niessen WJ, Viergever MA Eds. Medical Image Computing and Computer-Assisted Intervention (MICCAI 2001); 2001. Berlin: Springer-Verlag, 2001, pp 177–185 Meijering E, Niessen W, Weickert J, Viergever M: Evaluation of diffusion techniques for improved vessel visualization and quantification in three-dimensional rotational angiography. In: Niessen WJ, Viergever MA Eds. Medical Image Computing and Computer-Assisted Intervention (MICCAI 2001); 2001. Berlin: Springer-Verlag, 2001, pp 177–185
11.
go back to reference Niemisto A, Dunmire V, Yli-Harja O, Zhang W, Shmulevich I: Robust quantification of in vitro angiogenesis through image analysis. IEEE Trans Med Imaging 24(4):549–553, 2005PubMedCrossRef Niemisto A, Dunmire V, Yli-Harja O, Zhang W, Shmulevich I: Robust quantification of in vitro angiogenesis through image analysis. IEEE Trans Med Imaging 24(4):549–553, 2005PubMedCrossRef
12.
go back to reference Quek FK, Kirbas C: Vessel extraction in medical images by wave-propagation and traceback. IEEE Trans Med Imaging 20(2):117–131, 2001PubMedCrossRef Quek FK, Kirbas C: Vessel extraction in medical images by wave-propagation and traceback. IEEE Trans Med Imaging 20(2):117–131, 2001PubMedCrossRef
13.
go back to reference Wink O, Niessen WJ, Viergever MA: Multiscale vessel tracking. IEEE Trans Med Imaging 23(1):130–133, 2004PubMedCrossRef Wink O, Niessen WJ, Viergever MA: Multiscale vessel tracking. IEEE Trans Med Imaging 23(1):130–133, 2004PubMedCrossRef
14.
go back to reference Frangi AF, Niessen WJ, Hoogeveen RM, van Walsum T, Viergever MA: Model-based quantitation of 3-D magnetic resonance angiographic images. IEEE Trans Med Imaging 18(10):946–956, 1999PubMedCrossRef Frangi AF, Niessen WJ, Hoogeveen RM, van Walsum T, Viergever MA: Model-based quantitation of 3-D magnetic resonance angiographic images. IEEE Trans Med Imaging 18(10):946–956, 1999PubMedCrossRef
15.
go back to reference Lorenz C, Carlsen IC, Buzug TM, Fassnacht C, Weese J: A multi-scale line filter with automatic scale selection based on the Hessian matrix for medical image segmentation. In: ter Haar Romeny B, Florack L, Koenderink J, Viergever M Eds. First International Conference on Scale-Space Theory in Computer Vision; 1997. New York: Springer-Verlag, 1997, pp 152–163 Lorenz C, Carlsen IC, Buzug TM, Fassnacht C, Weese J: A multi-scale line filter with automatic scale selection based on the Hessian matrix for medical image segmentation. In: ter Haar Romeny B, Florack L, Koenderink J, Viergever M Eds. First International Conference on Scale-Space Theory in Computer Vision; 1997. New York: Springer-Verlag, 1997, pp 152–163
16.
go back to reference Sato Y, Yamamoto S, Tamura S: Accurate quantification of small-diameter tubular structures in isotropic CT volume data based on multiscale line filter responses. In: Barillot C, Haynor DR, Cunha JF, Hellier P Eds. 7th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2004). Springer, Saint-Malo, France, 2004, pp 508–515 Sato Y, Yamamoto S, Tamura S: Accurate quantification of small-diameter tubular structures in isotropic CT volume data based on multiscale line filter responses. In: Barillot C, Haynor DR, Cunha JF, Hellier P Eds. 7th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI 2004). Springer, Saint-Malo, France, 2004, pp 508–515
17.
go back to reference Florack LMJ, ter Haar Romery BM, Koenderink JJ, Viergever MA: Scale and the differential structure of images. Image Vis Comput 10(6):376–388, 1992CrossRef Florack LMJ, ter Haar Romery BM, Koenderink JJ, Viergever MA: Scale and the differential structure of images. Image Vis Comput 10(6):376–388, 1992CrossRef
18.
go back to reference Cebral JR, Hernandez M, Frangi AF: Computational analysis of blood flow dynamics in cerebral aneurysms from CTA and 3D rotational angiography image data. In: Doblare M, Cerrolaza M, Rodrigues H Eds. International Congress on Computational Bioengineering. Zaragoza, Spain, 2003 Cebral JR, Hernandez M, Frangi AF: Computational analysis of blood flow dynamics in cerebral aneurysms from CTA and 3D rotational angiography image data. In: Doblare M, Cerrolaza M, Rodrigues H Eds. International Congress on Computational Bioengineering. Zaragoza, Spain, 2003
19.
go back to reference Condurache A-P, Aach T: Vessel segmentation in angiograms using hysteresis thresholding. In: Ninth IAPR conference on Machine Vision Applications. Tsubuka Science City, Japan, 2005, pp 269–272 Condurache A-P, Aach T: Vessel segmentation in angiograms using hysteresis thresholding. In: Ninth IAPR conference on Machine Vision Applications. Tsubuka Science City, Japan, 2005, pp 269–272
20.
go back to reference Karnabatidis D, Katsanos K, Diamantopoulos A, Kagadis GC, Siablis D: Transauricular arterial or venous access for cardiovascular experimental protocols in animals. J Vasc Interv Radiol 17(11 Pt 1):1803–1811, 2006PubMedCrossRef Karnabatidis D, Katsanos K, Diamantopoulos A, Kagadis GC, Siablis D: Transauricular arterial or venous access for cardiovascular experimental protocols in animals. J Vasc Interv Radiol 17(11 Pt 1):1803–1811, 2006PubMedCrossRef
21.
go back to reference Panagopoulos AM, Dimakopoulos P, Tyllianakis M, Karnabatidis D, Siablis D, Papadopoulos AX, Lambiris E, Kraniotis P, Sakellaropoulos G: Valgus impacted proximal humeral fractures and their blood supply after transosseous suturing. Int Orthop 28(6):333–337, 2004PubMed Panagopoulos AM, Dimakopoulos P, Tyllianakis M, Karnabatidis D, Siablis D, Papadopoulos AX, Lambiris E, Kraniotis P, Sakellaropoulos G: Valgus impacted proximal humeral fractures and their blood supply after transosseous suturing. Int Orthop 28(6):333–337, 2004PubMed
22.
go back to reference Ingeholm P, Pedersen L, Holck S: Quantification of microvessel density of breast carcinoma: an assessment of the inter- and intraobserver variation. Breast 8(5):251–256, 1999PubMedCrossRef Ingeholm P, Pedersen L, Holck S: Quantification of microvessel density of breast carcinoma: an assessment of the inter- and intraobserver variation. Breast 8(5):251–256, 1999PubMedCrossRef
23.
go back to reference Konerding MA: Scanning electron microscopy of corrosion casting in medicine. Scanning Microsc 5(3):851–865, 1991PubMed Konerding MA: Scanning electron microscopy of corrosion casting in medicine. Scanning Microsc 5(3):851–865, 1991PubMed
24.
go back to reference Obuchowski NA: Receiver operating characteristic curves and their use in radiology. Radiology 229(1):3–8, 2003PubMedCrossRef Obuchowski NA: Receiver operating characteristic curves and their use in radiology. Radiology 229(1):3–8, 2003PubMedCrossRef
25.
go back to reference Nikiforidis G, Papazafiropoulos D, Siablis D, Karnabatidis D, Hatjikondi O, Dimopoulos J: Quantitative assessment of angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images. Eur J Radiol 29(2):168–179, 1999PubMedCrossRef Nikiforidis G, Papazafiropoulos D, Siablis D, Karnabatidis D, Hatjikondi O, Dimopoulos J: Quantitative assessment of angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images. Eur J Radiol 29(2):168–179, 1999PubMedCrossRef
26.
go back to reference Karnabatidis D, Dimopoulos JC, Siablis D, Papazafiropoulos D, Kalogeropoulou CP, Nikiforidis G: Quantification of the ionising radiation effect over angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images. Acta Radiol 42(3):333–8, 2001PubMedCrossRef Karnabatidis D, Dimopoulos JC, Siablis D, Papazafiropoulos D, Kalogeropoulou CP, Nikiforidis G: Quantification of the ionising radiation effect over angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images. Acta Radiol 42(3):333–8, 2001PubMedCrossRef
27.
go back to reference Siablis D, Karnabatidis D, Katsanos K, Kagadis GC, Kraniotis P, Diamantopoulos A, Tsolakis J: Sirolimus-eluting versus bare stents after suboptimal infrapopliteal angioplasty for critical limb ischemia: enduring 1-year angiographic and clinical benefit. J Endovasc Ther 14(2):241–250, 2007PubMedCrossRef Siablis D, Karnabatidis D, Katsanos K, Kagadis GC, Kraniotis P, Diamantopoulos A, Tsolakis J: Sirolimus-eluting versus bare stents after suboptimal infrapopliteal angioplasty for critical limb ischemia: enduring 1-year angiographic and clinical benefit. J Endovasc Ther 14(2):241–250, 2007PubMedCrossRef
28.
go back to reference Baumgartner I, Thoeny HC, Kummer O, Roefke C, Skjelsvik C, Boesch C, Kreis R: Leg ischemia: assessment with MR angiography and spectroscopy. Radiology 234(3):833–841, 2005PubMedCrossRef Baumgartner I, Thoeny HC, Kummer O, Roefke C, Skjelsvik C, Boesch C, Kreis R: Leg ischemia: assessment with MR angiography and spectroscopy. Radiology 234(3):833–841, 2005PubMedCrossRef
29.
go back to reference Kothari M, Guermazi A, White D, Suhy J, Reinhold C: Imaging in antiangiogenesis trial: a clinical trials radiology perspective. Br J Radiol 76(Spec No 1):S92–S96, 2003PubMedCrossRef Kothari M, Guermazi A, White D, Suhy J, Reinhold C: Imaging in antiangiogenesis trial: a clinical trials radiology perspective. Br J Radiol 76(Spec No 1):S92–S96, 2003PubMedCrossRef
30.
go back to reference Kagadis G, Spyridonos P, Mihailidis D, Daskalakis A, Katsanos K, Diamantopoulos A, Karnabatidis D, Siablis D, Cavouras D, Nikiforidis G: A computerized automated segmentation methodology for the recognition of vessels from in vivo acquired DSA images. In: 48th Annual Meeting of the AAPM. Orlando, FL, USA, 2006, p 2018 Kagadis G, Spyridonos P, Mihailidis D, Daskalakis A, Katsanos K, Diamantopoulos A, Karnabatidis D, Siablis D, Cavouras D, Nikiforidis G: A computerized automated segmentation methodology for the recognition of vessels from in vivo acquired DSA images. In: 48th Annual Meeting of the AAPM. Orlando, FL, USA, 2006, p 2018
Metadata
Title
Computerized Analysis of Digital Subtraction Angiography: A Tool for Quantitative In-vivo Vascular Imaging
Authors
George C. Kagadis
Panagiota Spyridonos
Dimitris Karnabatidis
Athanassios Diamantopoulos
Emmanouil Athanasiadis
Antonis Daskalakis
Konstantinos Katsanos
Dionisios Cavouras
Dimitris Mihailidis
Dimitris Siablis
George C. Nikiforidis
Publication date
01-12-2008
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2008
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-007-9047-2

Other articles of this Issue 4/2008

Journal of Digital Imaging 4/2008 Go to the issue