Abstract

Objective

To investigate the application value of dual-source computed tomography (DSCT) in preoperative assessment the rupture site of an thoracic aortic dissection (TAD).

Methods

A retrospective analysis of preoperative DSCT, multislice computed tomography (MSCT), and transthoracic echocardiography (TTE) results of 150 patients with suspected TAD in our hospital was conducted, and the intraoperative findings or interventional treatment results were used as the diagnostic gold standard.

Results

Of all 150 suspected TAD patients, 123 patients were confirmed to have TAD. The rupture site of TAD was in the ascending aorta in 46 patients, in the aortic arch in 13 patients, and in the descending aorta in 64 patients. The sensitivity of DSCT, MSCT, and TTE for locating the rupture site of the TAD was 100%, 93.5%, and 89.5%, respectively, and the specificity was 100%, 88.9%, and 81.5%. The differences were statistically significant. The distance between the actual rupture site and the one diagnosed by DSCT, MSCT, and TTE was 1.9 ± 1.2 mm, 5.1 ± 2.7 mm, and 7.8 ± 3.5 mm, respectively; the latter two were significantly worse than DSCT. The size of the rupture site diagnosed by DSCT, MSCT, and TTE was 1.5 ± 0.8 cm, 1.7 ± 0.9 cm, and 1.9 ± 1.0 cm, respectively. The size of the rupture site diagnosed by DSCT was not significantly different from the actual size of 1.4 ± 0.7 cm, while those by MSCT and TTE were.

Conclusion

DSCT has high sensitivity and specificity in diagnosing the rupture site of TAD and can clearly locate the rupture site. It can be a preferred imaging method for TAD.
Literature
1.
go back to reference Kosuge M, Kimura K, Uchida K, Masuda M, Tamura K. Clinical implications of electrocardiograms for patients with type A Acute Aortic Dissection. Circ J. 2017;81(9):1254–60.CrossRef Kosuge M, Kimura K, Uchida K, Masuda M, Tamura K. Clinical implications of electrocardiograms for patients with type A Acute Aortic Dissection. Circ J. 2017;81(9):1254–60.CrossRef
2.
go back to reference Elsayed RS, Cohen RG, Fleischman F, Bowdish ME. Acute type A aortic dissection. Cardiol Clin. 2017;35(3):331–45.CrossRef Elsayed RS, Cohen RG, Fleischman F, Bowdish ME. Acute type A aortic dissection. Cardiol Clin. 2017;35(3):331–45.CrossRef
3.
go back to reference Nienaber CA, Clough RE. Management of acute aortic dissection. Lancet. 2015;385(9970):800–11.CrossRef Nienaber CA, Clough RE. Management of acute aortic dissection. Lancet. 2015;385(9970):800–11.CrossRef
4.
go back to reference Ohle R, Kareemi HK, Wells G, Perry JJ. Clinical examination for acute aortic dissection: a systematic review and meta-analysis. Acad Emerg Med. 2018;25(4):397–412.CrossRef Ohle R, Kareemi HK, Wells G, Perry JJ. Clinical examination for acute aortic dissection: a systematic review and meta-analysis. Acad Emerg Med. 2018;25(4):397–412.CrossRef
5.
go back to reference Gawinecka J, Schönrath F, von Eckardstein A. Acute aortic dissection: pathogenesis, risk factors and diagnosis. Swiss Med Wkly. 2017;147:w14489.PubMed Gawinecka J, Schönrath F, von Eckardstein A. Acute aortic dissection: pathogenesis, risk factors and diagnosis. Swiss Med Wkly. 2017;147:w14489.PubMed
6.
go back to reference Liu F, Huang L. Usefulness of ultrasound in the management of aortic dissection. Rev Cardiovasc Med. 2018;19(3):103–9.PubMed Liu F, Huang L. Usefulness of ultrasound in the management of aortic dissection. Rev Cardiovasc Med. 2018;19(3):103–9.PubMed
7.
go back to reference Karthikesalingam A, Holt PJ, Hinchliffe RJ, Thompson MM, Loftus IM. The diagnosis and management of aortic dissection. Vasc Endovasc Surg. 2010;44(3):165–9.CrossRef Karthikesalingam A, Holt PJ, Hinchliffe RJ, Thompson MM, Loftus IM. The diagnosis and management of aortic dissection. Vasc Endovasc Surg. 2010;44(3):165–9.CrossRef
8.
go back to reference Baliga RR, Nienaber CA, Bossone E, Oh JK, Isselbacher EM, Sechtem U, Fattori R, Raman SV, Eagle KA. The role of imaging in aortic dissection and related syndromes. JACC Cardiovasc Imaging. 2014;7(4):406–24.CrossRef Baliga RR, Nienaber CA, Bossone E, Oh JK, Isselbacher EM, Sechtem U, Fattori R, Raman SV, Eagle KA. The role of imaging in aortic dissection and related syndromes. JACC Cardiovasc Imaging. 2014;7(4):406–24.CrossRef
9.
go back to reference Sobczyk D, Nycz K. Feasibility and accuracy of bedside transthoracic echocardiography in diagnosis of acuteproximal aortic dissection. Cardiovasc Ultrasound. 2015;13:15.CrossRef Sobczyk D, Nycz K. Feasibility and accuracy of bedside transthoracic echocardiography in diagnosis of acuteproximal aortic dissection. Cardiovasc Ultrasound. 2015;13:15.CrossRef
10.
go back to reference Brunson JM, Fine RL, Schussler JM. Acute ascending aortic dissection diagnosed with transthoracic echocardiography. J Am Soc Echocardiogr. 2009;22(9):1086.e5-1086.e7.CrossRef Brunson JM, Fine RL, Schussler JM. Acute ascending aortic dissection diagnosed with transthoracic echocardiography. J Am Soc Echocardiogr. 2009;22(9):1086.e5-1086.e7.CrossRef
11.
go back to reference Patel PA, Bavaria JE, Ghadimi K, Gutsche JT, Vallabhajosyula P, Ko HA, Desai ND, Mackay E, Weiss SJ, Augoustides JGT. Aortic regurgitation in acute type-A aortic dissection: a clinical classification for the perioperative echocardiographer in the era of the functional aortic annulus. J Cardiothorac Vasc Anesth. 2018;32(1):586–97.CrossRef Patel PA, Bavaria JE, Ghadimi K, Gutsche JT, Vallabhajosyula P, Ko HA, Desai ND, Mackay E, Weiss SJ, Augoustides JGT. Aortic regurgitation in acute type-A aortic dissection: a clinical classification for the perioperative echocardiographer in the era of the functional aortic annulus. J Cardiothorac Vasc Anesth. 2018;32(1):586–97.CrossRef
12.
go back to reference Wynn GJ, Somauroo JD. Acute aortic dissection flap prolapsing into the left ventricle on transthoracic echocardiography. J Echocardiogr. 2012;10(4):154–5.CrossRef Wynn GJ, Somauroo JD. Acute aortic dissection flap prolapsing into the left ventricle on transthoracic echocardiography. J Echocardiogr. 2012;10(4):154–5.CrossRef
13.
go back to reference Erbel R, Alfonso F, Boileau C, Dirsch O, Eber B, Haverich A, Rakowski H, Struyven J, Radegran K, Sechtem U, Taylor J, Zollikofer C, Klein WW, Mulder B, Providencia LA, Task Force on Aortic Dissection, European Society of Cardiology. Diagnosis and management of aortic dissection. Eur Heart J. 2001;22(18):1642–81.CrossRef Erbel R, Alfonso F, Boileau C, Dirsch O, Eber B, Haverich A, Rakowski H, Struyven J, Radegran K, Sechtem U, Taylor J, Zollikofer C, Klein WW, Mulder B, Providencia LA, Task Force on Aortic Dissection, European Society of Cardiology. Diagnosis and management of aortic dissection. Eur Heart J. 2001;22(18):1642–81.CrossRef
14.
go back to reference Zhao DL, Liu XD, Zhao CL, Zhou HT, Wang GK, Liang HW, Zhang JL. Multislice spiral CT angiography for evaluation of acute aortic syndrome. Echocardiography. 2017;34(10):1495–9.CrossRef Zhao DL, Liu XD, Zhao CL, Zhou HT, Wang GK, Liang HW, Zhang JL. Multislice spiral CT angiography for evaluation of acute aortic syndrome. Echocardiography. 2017;34(10):1495–9.CrossRef
15.
go back to reference Chiu KW, Lakshminarayan R, Ettles DF. Acute aortic syndrome: CT findings. Clin Radiol. 2013;68(7):741–8.CrossRef Chiu KW, Lakshminarayan R, Ettles DF. Acute aortic syndrome: CT findings. Clin Radiol. 2013;68(7):741–8.CrossRef
16.
go back to reference Johnson TRC, Nikolaou K, Wintersperger BJ. ECG gated 64 slice CT angiography for the differential diagnosis of acute chest pain. Am J Roentgenol. 2007;188:76–82.CrossRef Johnson TRC, Nikolaou K, Wintersperger BJ. ECG gated 64 slice CT angiography for the differential diagnosis of acute chest pain. Am J Roentgenol. 2007;188:76–82.CrossRef
17.
go back to reference White CS, Kuo D, Kelemen M, Jain V, Musk A, Zaidi E, Read K, Sliker C, Prasad R. Chest pain evaluation in the emergency department: can MDCT provide a comprehensive evaluation? Am J Roentgenol. 2005;185(2):533–40.CrossRef White CS, Kuo D, Kelemen M, Jain V, Musk A, Zaidi E, Read K, Sliker C, Prasad R. Chest pain evaluation in the emergency department: can MDCT provide a comprehensive evaluation? Am J Roentgenol. 2005;185(2):533–40.CrossRef
18.
go back to reference Ko SF, Hsieh MJ, Chen MC, Ng SH, Fang FM, Huang CC, Wan YL, Lee TY. Effects of heart rate on motion artifacts of the aorta on non-ECG-assisted 0.5 sec thoracic MDC. Am J Roentgenol. 2005;184(4):1225–30.CrossRef Ko SF, Hsieh MJ, Chen MC, Ng SH, Fang FM, Huang CC, Wan YL, Lee TY. Effects of heart rate on motion artifacts of the aorta on non-ECG-assisted 0.5 sec thoracic MDC. Am J Roentgenol. 2005;184(4):1225–30.CrossRef
19.
go back to reference Abbas A, Brown IW, Peebles CR, Harden SP, Shambrook JS. The role of multidetector-row CT in the diagnosis, classification and management of acute aorticsyndrome. Br J Radiol. 2014;87(1042):20140354.CrossRef Abbas A, Brown IW, Peebles CR, Harden SP, Shambrook JS. The role of multidetector-row CT in the diagnosis, classification and management of acute aorticsyndrome. Br J Radiol. 2014;87(1042):20140354.CrossRef
20.
go back to reference Johnson TR, Nikolaou K, Becker A, Leber AW, Rist C, Wintersperger BJ, Reiser MF, Becker CR. Dual-source CT for chest pain assessment. Eur Radiol. 2008;18(4):773–80.CrossRef Johnson TR, Nikolaou K, Becker A, Leber AW, Rist C, Wintersperger BJ, Reiser MF, Becker CR. Dual-source CT for chest pain assessment. Eur Radiol. 2008;18(4):773–80.CrossRef
21.
go back to reference Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, Schepis T, Frauenfelder T, Schertler T, Husmann L, Grunenfelder J, Genoni M, Kaufmann PA, Marincek B, Leschka S. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol. 2006;16(12):2739–47.CrossRef Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, Schepis T, Frauenfelder T, Schertler T, Husmann L, Grunenfelder J, Genoni M, Kaufmann PA, Marincek B, Leschka S. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol. 2006;16(12):2739–47.CrossRef
22.
go back to reference Raptopoulos VD, Boiselle PB, Michailidis N. MDCT angiography of acute chest pain: evaluation of ECG-gated and nongated techniques. Am J Roentgenol. 2006;186(6 Suppl 2):S346-356.CrossRef Raptopoulos VD, Boiselle PB, Michailidis N. MDCT angiography of acute chest pain: evaluation of ECG-gated and nongated techniques. Am J Roentgenol. 2006;186(6 Suppl 2):S346-356.CrossRef
Metadata
Title
Application value of preoperative dual-source computed tomography in assessing the rupture site of thoracic aortic dissection
Authors
Fang Huang
Hong Wu
Qing-Quan Lai
Xiao-Ting Ke
Publication date
01-12-2021
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2021
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-021-01729-y

Other articles of this Issue 1/2021

Journal of Cardiothoracic Surgery 1/2021 Go to the issue