Skip to main content
Top
Published in: European Radiology 3/2020

01-03-2020 | Computed Tomography | Interventional

Computed tomography–guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol

Authors: Yu-Fei Fu, Guang-Chao Li, Qing-Song Xu, Yi-Bing Shi, Chen Wang, Tao Wang

Published in: European Radiology | Issue 3/2020

Login to get access

Abstract

Objectives

To assess the relative diagnostic utility of low- and standard-dose computed tomography (CT)–guided lung biopsy.

Methods

In this single-center, single-blind, prospective, randomized controlled trial, patients were enrolled between November 2016 and June 2017. Enrolled study participants were randomly selected to undergo either low- or standard-dose CT-guided lung biopsy. Diagnostic accuracy was the primary study endpoint, whereas technical success, radiation dose, and associated complications were secondary study endpoints.

Results

In total, 280 patients underwent study enrollment and randomization, with 271 (low-dose group, 135; standard-dose group, 136) receiving the assigned interventions. Both groups had a 100% technical success rate for CT-guided lung biopsy, and complication rates were similar between groups (p > 0.05). The mean dose-length product (36.0 ± 14.1 mGy cm vs. 361.8 ± 108.0 mGy cm, p < 0.001) and effective dose (0.5 ± 0.2 mSv vs. 5.1 ± 1.5 mSv, p < 0.001) were significantly reduced in the low-dose group participants. Sensitivity, specificity, and overall diagnostic accuracy rates in the low-dose group were 91.8%, 100%, and 94.6%, respectively, whereas in the standard-dose group, the corresponding values were 89.6%, 100%, and 92.4%, respectively. These results indicated that diagnostic performance did not differ significantly between the 2 groups. Using univariate and multivariate analyses, we found larger lesion size (p = 0.038) and procedure-related pneumothorax (p = 0.033) to both be independent predictors of diagnostic failure.

Conclusions

Our results demonstrate that low-dose CT-guided lung biopsy can yield comparable diagnostic accuracy to standard-dose CT guidance, while significantly reducing the radiation dose delivered to patients.
Trial registration: ClinicalTrials.gov NCT02971176

Key Points

Low-dose CT-guided lung biopsy is a safe and simple method for diagnosis of lung lesions.
Low-dose CT-guided lung biopsy can yield comparable diagnostic accuracy to standard-dose CT guidance.
Low-dose CT-guided lung biopsy can achieve a 90% reduction in radiation exposure when compared with standard-dose CT guidance.
Literature
1.
go back to reference Johnson JN, Hornik CP, Li JS et al (2014) Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation 130:161–167CrossRef Johnson JN, Hornik CP, Li JS et al (2014) Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation 130:161–167CrossRef
2.
go back to reference Fazel R, Krumholz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857CrossRef Fazel R, Krumholz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857CrossRef
3.
go back to reference Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRef Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRef
4.
go back to reference Kaneko M, Eguchi K, Ohmatsu H et al (1996) Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. Radiology 201:798–802CrossRef Kaneko M, Eguchi K, Ohmatsu H et al (1996) Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. Radiology 201:798–802CrossRef
5.
go back to reference Henschke CI, McCauley DI, Yankelevitz DF et al (1999) Early lung Cancer action project: overall design and findings from baseline screening. Lancet 354:99–105CrossRef Henschke CI, McCauley DI, Yankelevitz DF et al (1999) Early lung Cancer action project: overall design and findings from baseline screening. Lancet 354:99–105CrossRef
6.
go back to reference National Lung Screening Trial Research Team, Aberle DR, Adams AM et al (2011) Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 365:395–409CrossRef National Lung Screening Trial Research Team, Aberle DR, Adams AM et al (2011) Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 365:395–409CrossRef
7.
go back to reference Infante M, Cavuto S, Lutman FR et al (2015) Long-term follow-up results of the DANTE trial, a randomized study of lung cancer screening with spiral computed tomography. Am J Respir Crit Care Med 191:1166–1175CrossRef Infante M, Cavuto S, Lutman FR et al (2015) Long-term follow-up results of the DANTE trial, a randomized study of lung cancer screening with spiral computed tomography. Am J Respir Crit Care Med 191:1166–1175CrossRef
8.
go back to reference Zheng M, Wu Y, Wei M, Liu Y, Zhao H, Li J (2015) Lowconcentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition. Acad Radiol 22:195–202CrossRef Zheng M, Wu Y, Wei M, Liu Y, Zhao H, Li J (2015) Lowconcentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition. Acad Radiol 22:195–202CrossRef
9.
go back to reference Zheng M, Liu Y, Wei M et al (2014) Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tubevoltage technique: feasibility study. Eur J Radiol 83:e92–e99CrossRef Zheng M, Liu Y, Wei M et al (2014) Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tubevoltage technique: feasibility study. Eur J Radiol 83:e92–e99CrossRef
10.
go back to reference Wang T, GongY SY, Hua R, Zhang Q (2017) Feasibility of duallow scheme combined with iterative reconstruction technique in acute cerebral infarction volume CTwhole brain perfusion imaging. Exp Ther Med 14:163–168CrossRef Wang T, GongY SY, Hua R, Zhang Q (2017) Feasibility of duallow scheme combined with iterative reconstruction technique in acute cerebral infarction volume CTwhole brain perfusion imaging. Exp Ther Med 14:163–168CrossRef
11.
go back to reference Chen GZ, Zhang LJ, Schoepf UJ et al (2015) Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography. Eur Radiol 25:1453–1463CrossRef Chen GZ, Zhang LJ, Schoepf UJ et al (2015) Radiation dose and image quality of 70 kVp cerebral CT angiography with optimized sinogram-affirmed iterative reconstruction: comparison with 120 kVp cerebral CT angiography. Eur Radiol 25:1453–1463CrossRef
12.
go back to reference Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239CrossRef Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–239CrossRef
13.
go back to reference Sangha BS, Hague CJ, Jessup J et al (2016) Transthoracic computed tomography–guided lung nodule biopsy: comparison of core needle and fine needle aspiration techniques. Can Assoc Radiol J 67:284–289CrossRef Sangha BS, Hague CJ, Jessup J et al (2016) Transthoracic computed tomography–guided lung nodule biopsy: comparison of core needle and fine needle aspiration techniques. Can Assoc Radiol J 67:284–289CrossRef
14.
go back to reference Ocak S, Duplaquet F, Jamart J et al (2016) Diagnostic accuracy and safety of CT-guided percutaneous transthoracic needle biopsies: 14-gauge versus 22-gauge needles. J Vasc Interv Radiol 27:674–681CrossRef Ocak S, Duplaquet F, Jamart J et al (2016) Diagnostic accuracy and safety of CT-guided percutaneous transthoracic needle biopsies: 14-gauge versus 22-gauge needles. J Vasc Interv Radiol 27:674–681CrossRef
15.
go back to reference Tai R, Dunne RM, Trotman-Dickenson B et al (2016) Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 cases. Radiology 279:287–296CrossRef Tai R, Dunne RM, Trotman-Dickenson B et al (2016) Frequency and severity of pulmonary hemorrhage in patients undergoing percutaneous CT-guided transthoracic lung biopsy: single-institution experience of 1175 cases. Radiology 279:287–296CrossRef
16.
go back to reference Helck A, Schumann C, Aumann J et al (2016) Automatic path proposal computation for CT-guided percutaneous liver biopsy. Int J Comput Assist Radiol Surg 11:2199–2205CrossRef Helck A, Schumann C, Aumann J et al (2016) Automatic path proposal computation for CT-guided percutaneous liver biopsy. Int J Comput Assist Radiol Surg 11:2199–2205CrossRef
17.
go back to reference Shpilberg KA, Delman BN, Tanenbaum LN et al (2014) Radiation dose reduction in CT-guided spine biopsies does not reduce diagnostic yield. AJNR Am J Neuroradiol 35:2243–2247CrossRef Shpilberg KA, Delman BN, Tanenbaum LN et al (2014) Radiation dose reduction in CT-guided spine biopsies does not reduce diagnostic yield. AJNR Am J Neuroradiol 35:2243–2247CrossRef
18.
go back to reference Meng XX, Kuai XP, Dong WH et al (2013) Comparison of lung lesion biopsies between low-dose CT-guided and conventional CTguided techniques. Acta Radiol 54:909–915CrossRef Meng XX, Kuai XP, Dong WH et al (2013) Comparison of lung lesion biopsies between low-dose CT-guided and conventional CTguided techniques. Acta Radiol 54:909–915CrossRef
19.
go back to reference Lee HN, Lee SM, Choe J et al (2018) Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp). Acta Radiol 59:425–433CrossRef Lee HN, Lee SM, Choe J et al (2018) Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp). Acta Radiol 59:425–433CrossRef
20.
go back to reference Kallianos KG, Elicker BM, Henry TS et al (2016) Instituting a lowdose CT-guided lung biopsy protocol. Acad Radiol 23:1130–1136CrossRef Kallianos KG, Elicker BM, Henry TS et al (2016) Instituting a lowdose CT-guided lung biopsy protocol. Acad Radiol 23:1130–1136CrossRef
21.
go back to reference Adiga S, Athreya S (2014) Safety, efficacy, and feasibility of an ultra-low dose radiation protocol for CT-guided percutaneous needle biopsy of pulmonary lesions: initial experience. Clin Radiol 69:709–714CrossRef Adiga S, Athreya S (2014) Safety, efficacy, and feasibility of an ultra-low dose radiation protocol for CT-guided percutaneous needle biopsy of pulmonary lesions: initial experience. Clin Radiol 69:709–714CrossRef
22.
go back to reference Ettinger DS, Wood DE, Akerley W et al (2015) Non-small cell lung cancer, Version 6.2015. J Natl Compr Cancer Netw 13:515–524CrossRef Ettinger DS, Wood DE, Akerley W et al (2015) Non-small cell lung cancer, Version 6.2015. J Natl Compr Cancer Netw 13:515–524CrossRef
23.
go back to reference Kim JI, Park CM, Kim H et al (2017) Non-specific benign pathological results on transthoracic core-needle biopsy: how to differentiate false-negatives? Eur Radiol 27:3888–3895CrossRef Kim JI, Park CM, Kim H et al (2017) Non-specific benign pathological results on transthoracic core-needle biopsy: how to differentiate false-negatives? Eur Radiol 27:3888–3895CrossRef
24.
go back to reference Tian P, Wang Y, Li L et al (2017) CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing. J Thorac Dis 9:333–343CrossRef Tian P, Wang Y, Li L et al (2017) CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing. J Thorac Dis 9:333–343CrossRef
25.
go back to reference Yeow KM, Tsay PK, Cheung YC et al (2003) Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol 14:581–588CrossRef Yeow KM, Tsay PK, Cheung YC et al (2003) Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol 14:581–588CrossRef
26.
go back to reference Liu S, Li C, Yu X et al (2015) Diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy of solitary pulmonary nodules. Cardiovasc Intervent Radiol 38:416–421CrossRef Liu S, Li C, Yu X et al (2015) Diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy of solitary pulmonary nodules. Cardiovasc Intervent Radiol 38:416–421CrossRef
27.
go back to reference Lü Y, Fritz J, Li C et al (2013) Magnetic resonance imaging-guided percutaneous biopsy ofmediastinalmasses: diagnostic performance and safety. Investig Radiol 48:452–457CrossRef Lü Y, Fritz J, Li C et al (2013) Magnetic resonance imaging-guided percutaneous biopsy ofmediastinalmasses: diagnostic performance and safety. Investig Radiol 48:452–457CrossRef
Metadata
Title
Computed tomography–guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol
Authors
Yu-Fei Fu
Guang-Chao Li
Qing-Song Xu
Yi-Bing Shi
Chen Wang
Tao Wang
Publication date
01-03-2020
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 3/2020
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-019-06464-6

Other articles of this Issue 3/2020

European Radiology 3/2020 Go to the issue