Skip to main content
Top
Published in: Archives of Orthopaedic and Trauma Surgery 2/2020

01-02-2020 | Computed Tomography | Trauma Surgery

Three-dimensional computed tomography reconstruction improves the reliability of tibial pilon fracture classification and preoperative surgical planning

Authors: Alexander Keiler, Felix Riechelmann, Maria Thöni, Alexander Brunner, Benjamin Ulmar

Published in: Archives of Orthopaedic and Trauma Surgery | Issue 2/2020

Login to get access

Abstract

Purpose

In the present study, we aimed to evaluate the impact of two-dimensional multi-planar computed tomography (2D-MP-CT) scans and three-dimensional surface rendering computed tomography reconstruction (3D-SR-CT) on the inter- and intra-observer reliability of four commonly used classification systems for tibial pilon fractures, and on the reliability and validity of surgical treatment planning for fracture fixation.

Methods

Four observers evaluated computed tomography images of 35 cases with pilon fractures according to the classifications of Rüedi and Allgöwer, AO/OTA, Topliss, and Tang, and recommended a surgical treatment plan, including the surgical approach, implant position, and need for bone graft augmentation. Fractures were first evaluated using 2D-MP-CT, followed by 3D-SR-CT. We calculated the Kappa values for the correlation between the fracture classifications, types of surgical approaches, implant positions, and bone graft recommendations by the observers. Furthermore, we assessed the correlation between the treatment plans recommended by the observers and the actual surgical procedure performed.

Results

All classifications showed poor inter-observer reliability and moderate intra-observer reliability with 2D-MP-CT scans. The inter-observer reliability of the Rüedi and Allgöwer, AO/OTA, and Tang classifications improved to moderate, whereas the intra-observer reliability of the AO/OTA classification improved to good with additional 3D-SR-CT. The correlation between the suggested and the actually performed surgical approaches was poor with 2D-MP-CT, but improved to moderate with 3D-SR-CT. The suggested plate positions showed a moderate correlation with the actually performed plating; although the correlation improved significantly, it remained moderate with 3D-SR-CT.

Conclusion

The use of 3D-SR-CT reconstruction can improve the reliability of the Rüedi and Allgöwer, AO/OTA, and Tang classifications. Furthermore, three-dimensional imaging enables a more valid planning of the surgical approach and implant position.
Literature
3.
go back to reference Elsoe R, Larsen P, Petruskevicius J, Kold S (2018) Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator. Strateg Trauma Limb Reconstr 13(1):25–33. https://doi.org/10.1007/s11751-017-0301-y CrossRef Elsoe R, Larsen P, Petruskevicius J, Kold S (2018) Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator. Strateg Trauma Limb Reconstr 13(1):25–33. https://​doi.​org/​10.​1007/​s11751-017-0301-y CrossRef
8.
go back to reference Ruedi TP, Allgöwer M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop Relat Res 138:105–110 Ruedi TP, Allgöwer M (1979) The operative treatment of intra-articular fractures of the lower end of the tibia. Clin Orthop Relat Res 138:105–110
10.
go back to reference Tornetta P 3rd, Gorup J (1996) Axial computed tomography of pilon fractures. Clin Orthop Relat Res 323:273–276CrossRef Tornetta P 3rd, Gorup J (1996) Axial computed tomography of pilon fractures. Clin Orthop Relat Res 323:273–276CrossRef
11.
go back to reference Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, Prokuski L, Sirkin MS, Ziran B, Henley B, Audige L (2007) Fracture and dislocation classification compendium—2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21(10 Suppl):S1–133CrossRef Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, Prokuski L, Sirkin MS, Ziran B, Henley B, Audige L (2007) Fracture and dislocation classification compendium—2007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21(10 Suppl):S1–133CrossRef
12.
go back to reference Müller M, Nazarian S, Koch P, Schatzker J (1990) The comprehensive classification of fractures of long bones. Springer, BerlinCrossRef Müller M, Nazarian S, Koch P, Schatzker J (1990) The comprehensive classification of fractures of long bones. Springer, BerlinCrossRef
13.
go back to reference Tang X, Tang PF, Wang MY, Lu DC, Liu MZ, Liu CJ, Liu Y, Sun LZ, Huang LJ, Yu L, Zhao YG (2012) Pilon fractures: a new classification and therapeutic strategies. Chin Med J (Engl) 125(14):2487–2492 Tang X, Tang PF, Wang MY, Lu DC, Liu MZ, Liu CJ, Liu Y, Sun LZ, Huang LJ, Yu L, Zhao YG (2012) Pilon fractures: a new classification and therapeutic strategies. Chin Med J (Engl) 125(14):2487–2492
14.
go back to reference Martin JS, Marsh JL, Bonar SK, DeCoster TA, Found EM, Brandser EA (1997) Assessment of the AO/ASIF fracture classification for the distal tibia. J Orthop Trauma 11(7):477–483CrossRef Martin JS, Marsh JL, Bonar SK, DeCoster TA, Found EM, Brandser EA (1997) Assessment of the AO/ASIF fracture classification for the distal tibia. J Orthop Trauma 11(7):477–483CrossRef
16.
go back to reference Swiontkowski MF, Sands AK, Agel J, Diab M, Schwappach JR, Kreder HJ (1997) Interobserver variation in the AO/OTA fracture classification system for pilon fractures: is there a problem? J Orthop Trauma 11(7):467–470CrossRef Swiontkowski MF, Sands AK, Agel J, Diab M, Schwappach JR, Kreder HJ (1997) Interobserver variation in the AO/OTA fracture classification system for pilon fractures: is there a problem? J Orthop Trauma 11(7):467–470CrossRef
17.
go back to reference Brunner A, Honigmann P, Treumann T, Babst R (2009) The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus. J Bone Jt Surg Br 91(6):766–771. https://doi.org/10.1302/0301-620X.91B6.22109 CrossRef Brunner A, Honigmann P, Treumann T, Babst R (2009) The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus. J Bone Jt Surg Br 91(6):766–771. https://​doi.​org/​10.​1302/​0301-620X.​91B6.​22109 CrossRef
18.
go back to reference Doornberg J, Lindenhovius A, Kloen P, Dijk CN, Zurakowski D, Ring D (2006) Two and three-dimensional computed tomography for the classification and management of distal humeral fractures. Evaluation of reliability and diagnostic accuracy. J Bone Jt Surg Am 88(8):1795–1801CrossRef Doornberg J, Lindenhovius A, Kloen P, Dijk CN, Zurakowski D, Ring D (2006) Two and three-dimensional computed tomography for the classification and management of distal humeral fractures. Evaluation of reliability and diagnostic accuracy. J Bone Jt Surg Am 88(8):1795–1801CrossRef
19.
go back to reference Cohen J (1960) A coefficient of agreement for nominal scales. Educ Psycho Meas 20:37–46CrossRef Cohen J (1960) A coefficient of agreement for nominal scales. Educ Psycho Meas 20:37–46CrossRef
20.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRef
23.
go back to reference Ovadia DN, Beals RK (1986) Fractures of the tibial plafond. J Bone Jt Surg Am 68(4):543–551CrossRef Ovadia DN, Beals RK (1986) Fractures of the tibial plafond. J Bone Jt Surg Am 68(4):543–551CrossRef
24.
go back to reference Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160CrossRef Blauth M, Bastian L, Krettek C, Knop C, Evans S (2001) Surgical options for the treatment of severe tibial pilon fractures: a study of three techniques. J Orthop Trauma 15(3):153–160CrossRef
Metadata
Title
Three-dimensional computed tomography reconstruction improves the reliability of tibial pilon fracture classification and preoperative surgical planning
Authors
Alexander Keiler
Felix Riechelmann
Maria Thöni
Alexander Brunner
Benjamin Ulmar
Publication date
01-02-2020
Publisher
Springer Berlin Heidelberg
Published in
Archives of Orthopaedic and Trauma Surgery / Issue 2/2020
Print ISSN: 0936-8051
Electronic ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-019-03259-8

Other articles of this Issue 2/2020

Archives of Orthopaedic and Trauma Surgery 2/2020 Go to the issue